期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake 被引量:11
1
作者 Yue-ying PAN Shu-chang ZHOU +4 位作者 Yu-jin WANG Qian LI Ting-ting ZHU Chun-xia LIU Han-xiong GUAN 《Current Medical Science》 SCIE CAS 2020年第1期178-183,共6页
The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography,radiation dose and iodine intake was evaluated.A total of 121 patients with body mass index(BMI)<26 kg/m2 a... The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography,radiation dose and iodine intake was evaluated.A total of 121 patients with body mass index(BMI)<26 kg/m2 and heart rate(HR)<70 beats/min were randomly divided into four groups:group A(n=31,80 kVp,270 mgl/mL);group B(n=33,100 kVp,270 mgl/mL);group C(h=30,100 kVp,320 mgl/mL);group D(w=27,100 kVp,400 mgl/mL).The automatic current modulation system and the iterative algorithm for reconstruction were adopted in each group.The CT values and SD values of the aortic root(AR),subcutaneous fat,left coronary artery opening(LCA),and right coronary artery opening(RCA)were measured in all groups,the signalto-noise ratio(SNR)and contrast noise ratio(CNR)were calculated,and effective radiation dose and iodine intake were recorded.The subjective assessment for image quality was performed by two physicians using a 4-point scale.The results were compared using the one-way ANOVA and rank sum tests.The image quality of the four groups met the clinical diagnostic requirements.The CT values of AR in groups A,B,C,and D were 537.6±71.4,447.2±81.9,445.2±64.9 and 518.5±94.9 Hu,respectively,with no significant difference between group A and group D,or between group B and group C,while CT values in groups B and C were significantly lower than those in groups A and D(P<0.05).In groups A,B,C,and D,the LCA SNR values were 22.7±9.1,23.3±9.1,23.3±7.7 and 26.6±8.9,and the RCA CNR values were 26.9±9.&28.5±11.4,27.7土&8 and 32」±10.6,respectively.The AR visual scores in groups A,B,C and D were 3.8±0.2,3.9±0.3,3.9±0.3 and 4.0±0.3,respectively.There were no significant differences in SNR,CNR and visual score among the four groups(P>0.05).The radiation doses in groups A,B,C and D were 2.6±1.4,3.6±1.&4.9±3.5 and 4.9±2.8 mSv,respectively.The radiation dose in group A was significantly less than that in the rest three groups(P<0.05).The iodine intakes in groups A,B,C and D were 14.9±1.5,15.0±1.5,17.7±2.0 and 18.1±2.5 g,respectively.There was no significant difference in the intake of iodine between groups C and D,or between groups A and B,while iodine intake in groups A and B were significantly reduced as compared with that in groups C and D(P<0.05).It was concluded that for patients with low BMI and controlled HR,compared to 100 kVp tube voltage combined with multiple concentration contrast agents,80 kVp combined with 270 mgl/mL contrast agent is enough to ensure the quality of the images,and can reduce the radiation dose significantly,while reducing the amount of iodine intake notably,thus reducing the incidence of adverse reaction. 展开更多
关键词 tube voltage contrast agent coronary ct angiography radiation dose iodine intake
下载PDF
High Prevalence of Anatomical Variations and Anomalies of the Coronary Arteries Detected by CT Angiography in Symptomatic Patients
2
作者 Ghazi A.Alshumrani 《Congenital Heart Disease》 SCIE 2024年第2期197-206,共10页
Objective:Coronary artery anatomical variations and anomalies are an important topic due to their potential clinical manifestations.This study aims to investigate the prevalence of coronary artery anatomical variation... Objective:Coronary artery anatomical variations and anomalies are an important topic due to their potential clinical manifestations.This study aims to investigate the prevalence of coronary artery anatomical variations and anomalies in symptomatic patients with coronary computed tomography angiography(CCTA).Methods:This is a retrospective study that included all symptomatic patients who had CCTA in a tertiary care hospital in Saudi Arabia during a period of seven years.Results:The total number of included patients was 507(60%males)with a mean age of 57.4 years.Approximately 41%had luminal stenoses,averaging 49.7%.The total num-ber of patients with coronary anatomical variations(CAV)and coronary artery anomalies(CAA)was 217(43%).CAV prevalence was 26%,which included 14%non-right coronary dominance,5%short left main coronary artery(LMCA),and 7%division variations(trifurcation and quadrifurcarion)of the LMCA.The prevalence of CAA was 29%,which included 5%origin anomalies,22%myocardial bridge,and 2%course anomalies.Conclusions:A high prevalence of coronary artery anatomic variations and anomalies in symptomatic patients is reported in this study.Systematic reviews,meta-analyses,reporting guidelines,and unified definitions and classifications of cor-onary variations and anomalies are lacking in the literature,presenting potential opportunities for future research and publications. 展开更多
关键词 coronary artery anomalies coronary anatomical variation coronary ct angiography
下载PDF
Predictors of inaccurate coronary arterial stenosis assessment by CT angiography 被引量:1
3
《South China Journal of Cardiology》 CAS 2013年第3期216-217,共2页
ABSTRACT Objectives This study sought to investigate the clinical and imaging characteristics associated with diagnostic inaccuracy of computed tomography angiography (CTA) for detecting obstructive coronary artery... ABSTRACT Objectives This study sought to investigate the clinical and imaging characteristics associated with diagnostic inaccuracy of computed tomography angiography (CTA) for detecting obstructive coronary artery disease (CAD) defined by quantitative coronary angiography (QCA). 展开更多
关键词 ctA CAD Predictors of inaccurate coronary arterial stenosis assessment by ct angiography
原文传递
Comparison of low-dose sequences of dual-source CT and echocardiography for preoperative evaluation of aortic valve disease 被引量:2
4
作者 FENG Juan WANG Xi-ming +4 位作者 JI Xiao-peng LI Hai-ou LI Qiao GUO Wen-bin WANG Zheng-jun 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第23期4423-4429,共7页
Background Accurate evaluation of coronary artery,aortic valve annulus diameter (AVAD),and cardiac function in patients with aortic valve disease is of great significance for surgical strategy.In this study,we explo... Background Accurate evaluation of coronary artery,aortic valve annulus diameter (AVAD),and cardiac function in patients with aortic valve disease is of great significance for surgical strategy.In this study,we explored the preoperative evaluation of low-dose sequence (MinDose sequence) scan of dual-source CT (DSCT) for those patients.Methods Forty patients suspected for aortic valve disease (the experimental group) underwent MinDose sequence of DSCT to observe coronary artery,AVAD,and left ventricular ejection fraction (LVEF).Another 33 subjects suspected for coronary artery disease (the control group) underwent conventional retrospective electrocardiographically-gated sequence of DSCT.Two-dimensional transthoracic echocardiography (2D-TTE) and four-dimensional transthoracic echocardiography (4D-TTE) were applied in the experimental group to measure AVAD and LVEF and compared with MinDose-DSCT.Results There was a strong correlation between LVEFs measured by 2D-TTE and MinDose-DSCT (r=0.87,P <0.01),as well as between 4D-TTE and MinDose-DSCT (r=0.90,P <0.01).AVAD measured by MinDose-DSCT was in good agreement with corresponding measurements by 2D-TTE (r=0.90,P <0.01).The effective dose in the experimental group was 63.54% lower than that in the control group.Conclusions MinDose sequence of DSCT with a low radiation dose serving as a one-stop preoperative evaluation makes effective assessment of the coronary artery,AVAD,and LVEF for patients with aortic valve disease. 展开更多
关键词 radiation dose coronary ct angiography dual-source ct cardiac function aortic valve annulus diameters
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部