BACKGROUND Numerous studies have found that patients experiencing sudden sensorineural hearing loss(SSHL),with or without accompanying vertigo,often show impaired vestibular function.However,there is a dearth of studi...BACKGROUND Numerous studies have found that patients experiencing sudden sensorineural hearing loss(SSHL),with or without accompanying vertigo,often show impaired vestibular function.However,there is a dearth of studies analyzing vestibularevoked myogenic potentials(VEMPs)in SSHL patients across various age groups.AIM To investigate vestibular condition in SSHL patients across various age demographics.METHODS Clinical data of 84 SSHL patients were investigated retrospectively.Audiometry,cervical vestibular evoked myogenic potentials(c-VEMPs),and ocular vestibular evoked myogenic potentials(o-VEMPs)were conducted on these patients.Parameters assessed included the latencies of P1 and N1 waves,as well as the amplitudes of P1–N1 waves.Moreover,the study evaluated the influence of factors such as sex,affected side,configuration of hearing loss,and presence of accompanying vertigo.RESULTS Among the 84 SSHL patients,no significant differences were observed among the three groups in terms of gender,affected side,and the presence or absence of vertigo.Group II(aged 41–60 years)had the highest number of SSHL cases.The rates of absent o-VEMPs in the affected ears were 20.83%,31.58%,and 22.72%for the three age groups,respectively,with no statistically significant difference among them.The rates of absent c-VEMPs in the affected ears were 8.3%,34.21%,and 18.18%for the three age groups,respectively,with significant differences.In the unaffected ears,there were differences observed in the extraction rates of o-VEMPs in the unaffected ears among the age groups.In the three age groups,no significant differences were noted in the three age groups in the latencies of P1 and N1 waves or in the amplitude of N1–P1 waves for c-VEMPs and o-VEMPs,either on the affected side or on the unaffected side,across the three age groups.CONCLUSION The extraction rate of VEMPs is more valuable than parameters.Regardless of the presence of vertigo,vestibular organs are involved in SSHL.Notably,SSHL patients aged 41–60 appear more susceptible to damage to the inferior vestibular nerve and saccule.展开更多
Purpose: This review article provides the readers with an in-depth insight in understanding and interpreting various research literatures on the masseter vestibular evoked myogenic potentials(mVEMP). The article also ...Purpose: This review article provides the readers with an in-depth insight in understanding and interpreting various research literatures on the masseter vestibular evoked myogenic potentials(mVEMP). The article also reviews the contemporary researches involving the clinical applications of the mVEMP. Conclusions: Masseter VEMP is an evolving yet clinically promising neuro-otology test tool that has recently gained more research interest and is considered an additional tool to diagnose various vestibular disorders. Masseter VEMP assesses the functional integrity of the acoustic-masseteric and vestibulo-masseteric reflex pathways. The mVEMP could be used as a complementary test to evaluate the same peripheral generator as the cervical VEMP but a different central pathway i.e., vestibulo-trigeminal pathway. Various research studies that have experimented on parameters such as the effect of different electrode montages(zygomatic vs mandibular configurations), stimulation rates, filter settings and stimuli used to evoke mVEMP have been discussed in this article that could assist in the optimization of a comprehensive clinical protocol. The latency and the amplitude of mVEMP waveforms serve as significant parameters in differentiating normals from those of the clinical populations. Along with the cVEMPs and oVEMPs, mVEMP might help diagnose brainstem lesions in REM Sleep behaviour disorders, Multiple Sclerosis and Parkinson's disease. However, further studies are required to probe in this area of research.展开更多
Abnormal SEP reflects dysfunction of the medial lemniscus and posterior cervical cord. These structures are likely to be affected in Chiari malformation. Therefore, SEP abnormalities may provide valuable information i...Abnormal SEP reflects dysfunction of the medial lemniscus and posterior cervical cord. These structures are likely to be affected in Chiari malformation. Therefore, SEP abnormalities may provide valuable information in patients with CM. However, the consistency of SEP abnormality or normality with the damage is a matter of research. Knowing whether median nerve somatosensory evoked potential (SEP) is useful in revealing subclinical damage in patients with Chiari malformation is important in the treatment and follow-up plan of the disease. The aim of this study was to investigate the relationship between median nerve SEP values and the severity of cerebellar ectopia in patients with Chiari type 1 malformation. Median nerve SEP values were obtained from 30 healthy individuals and 146 individuals with Chiari malformation. The cerebellar ectopia degree and McRae line length were measured. SEP values were not significantly different between groups. The McRae line was found to be significantly shorter in the control group than in the Chiari malformation group (p = 0.031). There was no correlation between the degree of cerebellar ectopia and the length of the McRae line (r = 0.002, p = 0.979). Neither cerebellar ectopy degree nor McRae line length had a relationship with SEP values (r = -0.153, p = 0.066;r = -0.056, p = 0.500, respectively). There was no difference in cerebellar ectopy degree or SEP values between the groups with cerebellar ectopy with and without a syrinx (p = 0.899;p = 0.080, respectively). Likewise, McRae line length was not found to be related to the presence of a syrinx (p = 0.139). Median nerve SEP examination was not beneficial for diagnosing asymptomatic-oligosymptomatic Chiari malformation as a subclinical injury, whether accompanied by syringomyelia or not.展开更多
The spinal cord is at risk of injury during spinal surgery.If intraoperative spinal co rd injury is identified early,irreve rsible impairment or loss of neurological function can be prevented.Different types of spinal...The spinal cord is at risk of injury during spinal surgery.If intraoperative spinal co rd injury is identified early,irreve rsible impairment or loss of neurological function can be prevented.Different types of spinal cord injury result in damage to diffe rent spinal cord regions,which may cause diffe rent somatosensory and motor evoked potential signal res ponses.In this study,we examined electrophysiological and histopathological changes between contusion,distra ction,and dislocation spinal cord injuries in a rat model.We found that contusion led to the most severe dorsal white matter injury and caused considerable attenuation of both somatosensory and motor evoked potentials.Dislocation resulted in loss of myelinated axons in the lateral region of the injured spinal cord along the rostrocaudal axis.The amplitude of attenuation in motor evoked potential responses caused by dislocation was greater than that caused by contusion.After distraction injury,extracellular spaces were slightly but not significantly enlarged;somatosensory evoked potential res ponses slightly decreased and motor evoked potential responses were lost.Correlation analysis showed that histological and electrophysiological findings we re significantly correlated and related to injury type.Intraope rative monitoring of both somatosensory and motor evoked potentials has the potential to identify iatrogenic spinal cord injury type during surgery.展开更多
Objective:To analyze the correlation between the amplitude changes of motor evoked potential(MEP),the 3D volume changes of spinal canal measuring by postoperative CT and the improvement rate of clinical symptoms after...Objective:To analyze the correlation between the amplitude changes of motor evoked potential(MEP),the 3D volume changes of spinal canal measuring by postoperative CT and the improvement rate of clinical symptoms after the spinal canal decompression in minimally invasive transforaminal lumbar interbody fusion(MIS-TLIF),and to explore the predictive value of the changes of both MEP amplitude and spinal canal volume in the assessment of long-term clinical prognosis in MIS-TLIF.Methods:A retrospective study of 68 patients with L4/5 spinal stenosis treated with MIS-TLIF was performed.The changes of both intraoperative MEP amplitude and 3D spinal canal volume during the spinal canal decompression,as well as the visual analogue scale(VAS)and Oswestry dysfunction index(ODI)scores in the long-term follow-up were all recorded.Results:The values of intraoperative MEP amplitude was 159.04%higher in 68 patients with MIS-TLIF after spinal canal decompression(P<0.01).The 3 postoperative 3D spinal canal volume(4.89±1.27)cm increased by 31.22%in comparison 3 with preoperative date(3.78±1.08)cm(P<0.01).The VAS and ODI scores were improved to 78.55%and 80.60%,respectively at the last follow-up(P<0.01).The improvement rate of MEP amplitude on the decompression side was positively correlated with the improvement rate of postoperative spinal canal volume(r=0.272,P=0.025).The improvement rate of postoperative spinal canal volume was positively correlated with the improvement rate of VAS and ODI at the last follow-up(r=0.656,r=0.490,P<0.01).Moreover,the improvement rate of MEP amplitude on the decompression side was also positively correlated with the improvement rate of VAS and ODI at the last follow-up(r=0.322 and 0.235,respectively,P<0.05).Conclusion:The increase of MEP amplitude after spinal canal decompression in patients with lumbar spinal stenosis treated by MIS-TLIF was closely correlated with both of the increase of spinal canal volume and the improvement of clinical symptoms.Therefore,MEP amplitude monitoring was not only the one of the important monitoring methods for predicting the prognosis of MIS-TLIF but also the reliably predictive value in the long-term clinical prognosis in MIS-TLIF.展开更多
Objective Early researches found that different heartbeat perceivers have different heartbeat evoked potential (HEP)waves.Two tasks were considered in our experiments to get more details about the differences betwee...Objective Early researches found that different heartbeat perceivers have different heartbeat evoked potential (HEP)waves.Two tasks were considered in our experiments to get more details about the differences between good and poor heartbeat perceivers at attention and resting state.Methods Thirty channels of electroencephalogram(EEG)were recorded in 22 subjects,who had been subdivided into good and poor heartbeat perceivers by mental tracking task. Principal component analysis(PCA)was applied to remove cardiac field artifact(CFA)from the HEP.Results(1)The good heart-beat perceivers showed difference between attention and resting state in the windows from 250 ms to 450 ms after R wave at C3 location and from 100 ms to 300 ms after R wave at C4 location;(2)The difference waveforms between good and poor heartbeat perceivers was a positive waveform at FZ from 220 ms to 340 ms after R wave,which was more significant in attention state.Conclusion Attention state had more effect on the HEPs of good heartbeat perceivers than that of poor heartbeat perceivers;and perception ability influenced HEPs more strongly in the attention state than in the resting state.展开更多
We observed the steady-state visually evoked potential(SSVEP) from a healthy subject using a compact quad-channel potassium spin exchange relaxation-free(SERF) optically pumped magnetometer(OPM). To this end, 30 s of ...We observed the steady-state visually evoked potential(SSVEP) from a healthy subject using a compact quad-channel potassium spin exchange relaxation-free(SERF) optically pumped magnetometer(OPM). To this end, 30 s of data were collected, and SSVEP-related magnetic responses with signal intensity ranging from 150 fT to 300 f T were observed for all four channels. The corresponding signal to noise ratio(SNR) was in the range of 3.5–5.5. We then used different channels to operate the sensor as a gradiometer. In the specific case of detecting SSVEP, we noticed that the short channel separation distance led to a strongly diminished gradiometer signal. Although not optimal for the case of SSVEP detection, this set-up can prove to be highly useful for other magnetoencephalography(MEG) paradigms that require good noise cancellation.Considering its compactness, low cost, and good performance, the K-SERF sensor has great potential for biomagnetic field measurements and brain-computer interfaces(BCI).展开更多
Aim: Extensive neurophysiological investigations were carried out in 100 healthy subjects and 84 patients with penileerectile dysfunction. Methods: Following examinations were performed, spinal and scalp somatosensory...Aim: Extensive neurophysiological investigations were carried out in 100 healthy subjects and 84 patients with penileerectile dysfunction. Methods: Following examinations were performed, spinal and scalp somatosensory evoked poten-tials (SEPs) to stimulation of the dorsal nerve of penis, motor evoked potentials (MEPs) from bulbocavernosus (BC) inresponse to scalp and spinal root stimulation, and measurement of sacral reflex latency (SRL) from anal sphincter (AS).Results: In the healthy subjects, the mean sensory total conduction time (sensory TCT), as measured at the peak of thescalp P1 (P40) wave was 39.73 ms. The mean sensory central conduction time (sensory CCT = spinal-to-scalp conductiontime) was 28.98 ms. The mean peripheral conduction time (PCP) was 9.40 ins. Transcranial brain stimulation was per-formed by using a magnetic stimulator during voluntary contraction of the examined muscle. Spinal root stimulation wasperformed at rest. Motor total conduction time (motor TCT) to BC muscles was 20.48 ms. Motor central conductiontime (motor CCT) to sacral cord segments controlling BC muscles was 14.42 ms at rest. The mean SRL was 35.13 ms.Conclusion: Combined or isolated abnormalities of SEPs, MEPs, and SRL were found in patients with erectile dysfunc-tion. (Asian J Androl 1999 Sep; 1 : 145 - 150)展开更多
A total of 43 prolonged coma patients with diffuse axonal injury received the somatosensory evoked potential examination one month after injury in the First Affiliated Hospital, School of Medicine, Zhejiang University...A total of 43 prolonged coma patients with diffuse axonal injury received the somatosensory evoked potential examination one month after injury in the First Affiliated Hospital, School of Medicine, Zhejiang University in China. Somatosensory evoked potentials were graded as normal, abnormal or absent (grades I-III) according to N20 amplitude and central conduction time. The outcome in patients with grade III somatosensory evoked potential was in each case unfavorable. The prognostic accuracy of grade III somatosensory evoked potential for unfavorable and non-awakening outcome was 100% and 80%, respectively. The prognostic accuracy of grade I somatosensory evoked potential for favorable and wakening outcome was 86% and 100%, respectively. These results suggest that somatosensory evoked potential grade is closely correlated with coma severity and degree of recovery. Somatosensory evoked potential is a valuable diagnostic tool to assess prognosis in prolonged coma patients with diffuse axonal injury.展开更多
It remains unclear whether spinal cord ischemia-reperfusion injury caused by ischemia and other non-mechanical factors can be monitored by somatosensory evoked potentials. Therefore, we monitored spinal cord ischemia-...It remains unclear whether spinal cord ischemia-reperfusion injury caused by ischemia and other non-mechanical factors can be monitored by somatosensory evoked potentials. Therefore, we monitored spinal cord ischemia-reperfusion injury in rabbits using somatosensory evoked potential detection technology. The results showed that the somatosensory evoked potential latency was significantly prolonged and the amplitude significantly reduced until it disappeared during the period of spinal cord ischemia. After reperfusion for 30-180 minutes, the amplitude and latency began to gradually recover; at 360 minutes of reperfusion, the latency showed no significant difference compared with the pre-ischemic value, while the somatosensory evoked potential amplitude in- creased, and severe hindlimb motor dysfunctions were detected. Experimental findings suggest that changes in somatosensory evoked potentia~ ~atency can reflect the degree of spinat cord ischemic injury, while the amplitude variations are indicators of the late spinal cord reperfusion injury, which provide evidence for the assessment of limb motor function and avoid iatrogenic spinal cord injury.展开更多
In this study, we aimed to study the pattern visual evoked potentials (P-VEPs) in two eyes with varying visual acuity in one eye and to provide an objective estimation of visual acuity by comparing P-VEPs in one and...In this study, we aimed to study the pattern visual evoked potentials (P-VEPs) in two eyes with varying visual acuity in one eye and to provide an objective estimation of visual acuity by comparing P-VEPs in one and two eyes. Thirty subjects were chosen, who had one eye with an acuity of 5.0, 4.85, 4.6, 4.0, or scieropia and obstructed vision and the other eye with an acuity of 5.0, respectively. P-VEPs were detected under the large grating stimuli at 3x4 spatial frequency, moderate grating stimuli (12× 16 spatial frequency) and small grating stimuli (48×64 spatial frequency). Under large grating stimuli, there was no significant difference in P100 peak latency between the groups, nor was there a significant difference between the amplitude of two eyes and the amplitude of one normal-vision eye. Under moderate and small grating stimuli, there was a significant difference in P100 peak latency between the group with both eyes having an acuity of 5.0 and the group with visual acuity below 4.0 in one eye. There was a significant difference in P100 amplitude between the group with visual acuity of 5.0 in both eyes and the group with one normal-vision eye. There was no significant difference in the amplitude of two eyes and the amplitude of one normal-vision eye between any other two groups. In forensic identification, characteristics and variability of P-VEPs in one and two eyes can be used to identify malingering or decline in visual acuity.展开更多
AIM:To compare the diagnostic performance of isolatedcheck visual evoked potential(ic VEP) and standard automated perimetry(SAP),for evaluating the application values of ic VEP in the detection of early glaucoma....AIM:To compare the diagnostic performance of isolatedcheck visual evoked potential(ic VEP) and standard automated perimetry(SAP),for evaluating the application values of ic VEP in the detection of early glaucoma.METHODS:Totally 144 subjects(288 eyes) were enrolled in this study.ic VEP testing was performed with the Neucodia visual electrophysiological diagnostic system.A 15% positive-contrast(bright) condition pattern was used in this device to differentiate between glaucoma patients and healthy control subjects.Signal-to-noise ratios(SNR) were derived based on a multivariate statistic.The eyes were judged as abnormal if the test yielded an SNR≤1.SAP testing was performed with the Humphrey Field Analyzer II.The visual fields were deemed as abnormality if the glaucoma hemifield test results outside normal limits;or the pattern standard deviation with P〈0.05;or the cluster of three or more non-edge points on the pattern deviation plot in a single hemifield with P〈0.05,one of which must have a P〈0.01.Disc photographs were graded as either glaucomatous optic neuropathy or normal by two experts who were masked to all other patient information.Moorfields regression analysis(MRA) used as a separate diagnostic classification was performed by Heidelberg retina tomograph(HRT).RESULTS:When the disc photograph grader was used as diagnostic standard,the sensitivity for SAP and ic VEP was 32.3% and 38.5% respectively and specificity was 82.3% and 77.8% respectively.When the MRA Classifier was used as the diagnostic standard,the sensitivity for SAP and ic VEP was 48.6% and 51.4% respectively and specificity was 84.1% and 78.0% respectively.When the combined structural assessment was used as the diagnostic standard,the sensitivity for SAP and ic VEP was 59.2%and 53.1% respectively and specificity was 84.2% and 84.6% respectivlely.There was no statistical significance between the sensitivity or specificity of SAP and ic VEP,regardless of which diagnostic standard was based on.CONCLUSION:The diagnostic performance of ic VEP is not better than that of SAP in the detection of early glaucoma.展开更多
The peripheral driver stimulating theory states that as a driver passes along a certain meridian during acupuncture; the driver provokes nerve sense devices along the meridian, resulting in the nerve impulse entering ...The peripheral driver stimulating theory states that as a driver passes along a certain meridian during acupuncture; the driver provokes nerve sense devices along the meridian, resulting in the nerve impulse entering the central nervous system. Accordingly, volunteers have reported propagated sensations along the meridians (PSM). The present study was designed to utilize a cortical somatosensory-evoked potential (CSEP) topographic map for determining whether stimulation expansion occurs in somatosensory area I when sensation was provoked in individuals with obvious PSM. The sensation was blocked by mechanical compression, and the sensation was imitated in individuals without PSM. Results revealed a red, high-potential signal in the representative area of the lower limbs in individuals with obvious PSM symptoms when the Gall Bladder Meridian (GBM) sensation passed to the head and face. This representative area was near the middle line of the CSEP topographic map, and a red, high-potential signal, which jumps over the representative area of the upper limbs, also appeared in the representative face area, which was at the external region of the CSEP topographic map. However, in individuals exhibiting no PSM, only a red high-potential signal appeared in the representative lower limb area. When Hegu (LI 4) was stimulated in individuals without PSM, an obvious evoked response appeared only in the representative upper limb area. However, when Hegu was stimulated in individuals exhibiting PSM, the response area was larger in the representative upper limb area and extended to the representative face area. When Guangrning (GB 37) was stimulated in PSM individuals, the face representation response disappeared and was confined to a foot representation of the somatosensory area I when PSM was blocked by mechanical pressure. Results suggested that mechanical compression blocked PSM, and corresponding changes were exhibited in the CSEP topographic map. These results provide compelling evidence for the hypothesis that peripheral driver stimulation is the key element in producing PSM.展开更多
AIM: To evaluate the effect of sodium tungstate on visual evoked potentials(VEPs) in diabetic rats.· METHODS: Wistar rats were randomly divided into three groups as normal control, diabetic control and diabet...AIM: To evaluate the effect of sodium tungstate on visual evoked potentials(VEPs) in diabetic rats.· METHODS: Wistar rats were randomly divided into three groups as normal control, diabetic control and diabetic rats treated with sodium tungstate. Diabetes was induced by single intraperitoneal injection of streptozotocin(50 mg/kg). Sodium tungstate [40 mg/(kg·d)]was administered for 12 wk and then VEPs were recorded.Additionally, thiobarbituric acid reactive substance(TBARS) levels were measured in brain tissues.·RESULTS: The latencies of P1, N1, P2, N2 and P3 waves were significantly prolonged in diabetic rats compared with control group. Diabetes mellitus caused an increase in the lipid peroxidation process that was accompanied by changes in VEPs. However, prolonged latencies of VEPs for all components returned to control levels in sodium tungstate-treated group. The treatment of sodium tungstate significantly decreased brain TBARS levels and depleted the prolonged latencies of VEP components compared with diabetic control group.· CONCLUSION: Sodium tungstate shows protective effects on visual pathway in diabetic rats, and it can be worthy of further study for potential use.展开更多
Visual evoked potentials (VEPs) are a series of signals about visual occipital cortex in response to visual stimuli and can be used as one of ob-jective non-invasive neuro-physiological pa-rameters to reflect the visu...Visual evoked potentials (VEPs) are a series of signals about visual occipital cortex in response to visual stimuli and can be used as one of ob-jective non-invasive neuro-physiological pa-rameters to reflect the visual organs and central visual pathway’s functional integrity. Previous studies have shown that acute and chronic ex-ercise could affect VEPs independent from body temperature and other physiological parameters. VEPs may well be used as neuro-physiological criteria in defining the performances of the ath-letes. Different sports training have different effects on VEPs, but the results are not consis-tent. P100 latency is the representative compo-nent of VEPs and it is of high, steady amplitude and of slight intra- and inter-individual variabil-ity so that the index is most commonly used. The purpose of this study was to investigate the specificity and sensitivity of P100 latency to dif-ferent physical activities. The neural electricity device of NDI-200 was used to measure the pattern reversal VEPs of all subjects, including the values of the resting state before and after different events exercise. Different events exer-cise contained an aerobic cycloergometric ex-ercise (7 subjects were conducted to a Bruce Graded Exercise Test on the Monark Ergomedic 839E cycloergometer, THR (target heart rate) = 85% HRmax, 3 times/week, about 10 minutes once time, 6 weeks), tennis training (16 volun-teers, 2 hours/day, 3 days/week, 8 weeks), aerobic Latin exercise (7 subjects, 1 hour/day, 3 days/week, 6 weeks) and the Baduanjin of Health Qigong training (6 subjects, 1 hour/day, 3 days/week, 6 weeks). The VEPs recordings of the control groups obtained synchronized with the experimental groups. SPSS 11.5 for win-dows was used for statistical analysis. A level of P﹤0.05 was accepted as statistically significant. The VEPs P100 latency of post-exercise of all experimental groups except Baduanjin group became shorter significantly compared with those of pre-exercise (P﹤0.05). No significant difference was found between pre-and post- exercise for the control groups. This study showed that exercise could shorten the P100 la-tency significantly. Moreover, it also indicated that VEPs were sensitive to exercise to a certain extent. We concluded that VEPs might well be used as neuro-physiological criteria in defining the performances of the athletes. It was found that the VEPs P100 latency became shorter after most training programs;furthermore, it demon-strated that P100 latency of VEPs had little specificity to different events.展开更多
BACKGROUND: Pattern- visual evoked potential (PVEP) can reflect the functional status of retinal ganglial cells (RGC) and visual cortex, and is an objective examination for visual pathway function. It is a unique...BACKGROUND: Pattern- visual evoked potential (PVEP) can reflect the functional status of retinal ganglial cells (RGC) and visual cortex, and is an objective examination for visual pathway function. It is a unique method for objectively examining the optic nerve function of optic ganglion cells. OBJECTIVE: To observe the effects of nerve growth factor (NGF) on PVEF in the treatment of optic nerve contusion, evaluate the clinical efficacy of NGF, and make an efficacy comparison with vitamin B12. DESIGN: A randomly grouping, controlled observation. SETTING: Department of Ophthalmology, Tangshan Gongren Hospital Affiliated to Hebei Medical University. PARTICIPANTS: Forty patients with optic nerve contusion caused by eye trauma, who received the treatment in the Tangshan Worker Hospital Affiliated to Hebei Medical University between January 2006 and June 2007, were recruited in this study. The involved 40 patients, including 34 males and 6 females, were aged 14-59 years. They were confirmed to have optic nerve contusion by ophthalmologic consultation combined with history of disease and orbital CT examination. Informed consents of treatments and detected items were obtained from all the patients. The patients were randomly divided into 2 groups with 20 in each: NGF group and vitamin B12 group. METHODS: Conservative treatment was used in the two groups. In addition, patients in the NGF group were intramuscularly injected with NGF solution 18 μg /time, once a day. Those in the vitamin B12 group were injected by the same method with common vitamin B12 of 500 μg combined with vitamin B1 of 100 mg, once a day. MAIN OUTCOME MEASURES: PVEP examination was conducted in all the patients before, one and two weeks after treatment, and latency and amplitude at P100 were detected. RESULTS: Forty patients with optic nerve contusion participated in the final analysis. Before treatment, significant differences in the latency and amplitude at P100 were not found in patients between two groups (P 〉 0.05). For each patient in the NGF group, the latency of PVEP at P100 was significantly shortened, and the amplitude was significantly increased one and two weeks after treatment as compared with vitamin B12 group(t =2.06-2.34, P 〈 0.05). CONCLUSION: NGF treatment can obviously improve the visual function of patients with optic nerve contusion. The curative effect of NGF is superior to vitamin B12.展开更多
Aim: The effect of a renewed SS-cream (RSSC) on the treatment of premature ejaculation (PE) was evaluated and compared with the original SS-cream (OSSC). Methods: Sixty male white New Zealand rabbits, weighing 2.5kg-3...Aim: The effect of a renewed SS-cream (RSSC) on the treatment of premature ejaculation (PE) was evaluated and compared with the original SS-cream (OSSC). Methods: Sixty male white New Zealand rabbits, weighing 2.5kg-3.0 kg, were divided at random into 3 groups: the RSSC, OSSC and placebo groups. The spinal somatosensory evoked potential (SSEP) elicited by electric stimulation of the glans penis with disk electrode was investigated with an electrophysiograph (Poseidomn, Shanghai, China) before and 10, 30 and 60 min after drug or placebo application on the glans. The Onset and the N1 latencies and the amplitude of SSEP were recorded and analyzed. Results: There was no significant difference (P>0.05) in the mean Onset and Nl latency of SSEP among the 3 groups before drug application. Compared with the pre-application value, the mean Onset and Nl latencies in the RSSC and OSSC groups were significantly prolonged at 10, 30 and 60 min after treatment (P<0.05), while they were not significantly changed (P>0.05) in the placebo group. The mean Onset latency of RSSC at 10 and 30 min and that of OSSC at 30 min were significantly delayed (P<0.05) compared with the placebo group. The mean Nl latency of RSSC at 30 and 60 min and that of OSSC group at 30 min were also significantly delayed (P<0.05). Conclusion: RSSC delays the latencies of SSEP, suggesting a local desensitizing effect on the sensory receptor of the glans penis dorsal nerve, which provides the potential for PE treatment. The desensitizing effect of RSSC is higher than that of OSSC.展开更多
Under the auditory evoked brain stem potential (ABP) examination, the latent period of V wave and the intermittent periods of III-V peak and I-V peak were significantly shortened in Parkinson's disease patient... Under the auditory evoked brain stem potential (ABP) examination, the latent period of V wave and the intermittent periods of III-V peak and I-V peak were significantly shortened in Parkinson's disease patients of the treatment group (N=29) after acupuncture treatment. The difference of cumulative scores in Webster's scale was also decreased in correlation analysis. The increase of dopamine in the brain and the excitability of the dopamine neurons may contribute to the therapeutic effects, in TCM terms, of subduing the pathogenic wind and tranquilizing the mind.……展开更多
The effects of acupuncture on the sensory evoked cortical potentials were investigated in 31 rabbits anaesthetized with urethane of conscious, so as to see what happened to the functional state of cerebral cortex in t...The effects of acupuncture on the sensory evoked cortical potentials were investigated in 31 rabbits anaesthetized with urethane of conscious, so as to see what happened to the functional state of cerebral cortex in the meantime. The visual, auditory and somatosensory evoked potentials as well as raw EEGs were recorded from the animal’s scalp. In most cases, an electro-acupuncture instrument was used instead of manual acupuncture. The main component amplitudes of evoked potentials,the frequency band powers and the total integral values of raw EEGs were analyzed. Results showed that during acupuncture the main components of evoked potentials were significantly depressed and the raw EEGs appeared desynchronized while the experimental animals were slightly activated. Moreover,both the total integral values of raw EEGs and the powers of lower frequency waves (1 - 3. 99 Hz)were decreased and positively correlated well with the amplitudes of main components of the evoked potentials. Therefore, the possibility that the effects of acupuncture on the evoked potentials are secondary to the changes of raw EEGs remains to be ruled out, and it is suggested that the inhibition of evoked potentials during acupuncture does not necessarily mean that the cerebral cortex is in an inhibitory展开更多
Objective:To report vestibular evoked myogenic potentials from different recording sites(neck extensor or masseter muscles) in miniature pigs and rats.Methods:Potentials were recorded using 1000 Hz tone bursts from th...Objective:To report vestibular evoked myogenic potentials from different recording sites(neck extensor or masseter muscles) in miniature pigs and rats.Methods:Potentials were recorded using 1000 Hz tone bursts from the neck extensor muscle or masseter muscle in normal adult Bama miniature pigs and rats anesthetized with 3%pentobarbital sodium and Sumianxin Ⅱ.Results:At 80 dB SPL,the first positive wave(P wave) of VEMPs was recognizable in 58%of rats with a latency of 6.45±0.23 ms and an amplitude of 1.45±0.49 μV when recorded from the neck extensor muscle,and in 50%of rats with a latency of 6.38±0.34 ms and an amplitude of 1.57±0.35 μV when recorded from the masseter muscle.In miniature pigs,at the same stimulus intensity,P wave was recognizable in 58%of the animals with a latency of 7.65±0.64 ms and an amplitude of 1.66±0.34 μV when recorded from the neck extensor muscle,and in 50%of the animals with a latency of 7.65±0.64 ms and an amplitude of 0.31±0.28 μV when recorded from the masseter muscle.Conclusion:VEMP can be induced from both neck extensor and masseter muscles in the miniature pig and rat.For a given species,the site of recording affects P wave induction rate and amplitude but not latency.Consistency and repeatability analysis suggests that the masseter muscle is a better recording site in miniature pigs while the cervical extensor is a better recording site in rats.For a given recording site,both latency and amplitude of the P wave are slightly greater in miniature pigs than in rats.展开更多
基金the Innovative Program of Hebei Provincial Eye Hospital,No.2023ZZ107.
文摘BACKGROUND Numerous studies have found that patients experiencing sudden sensorineural hearing loss(SSHL),with or without accompanying vertigo,often show impaired vestibular function.However,there is a dearth of studies analyzing vestibularevoked myogenic potentials(VEMPs)in SSHL patients across various age groups.AIM To investigate vestibular condition in SSHL patients across various age demographics.METHODS Clinical data of 84 SSHL patients were investigated retrospectively.Audiometry,cervical vestibular evoked myogenic potentials(c-VEMPs),and ocular vestibular evoked myogenic potentials(o-VEMPs)were conducted on these patients.Parameters assessed included the latencies of P1 and N1 waves,as well as the amplitudes of P1–N1 waves.Moreover,the study evaluated the influence of factors such as sex,affected side,configuration of hearing loss,and presence of accompanying vertigo.RESULTS Among the 84 SSHL patients,no significant differences were observed among the three groups in terms of gender,affected side,and the presence or absence of vertigo.Group II(aged 41–60 years)had the highest number of SSHL cases.The rates of absent o-VEMPs in the affected ears were 20.83%,31.58%,and 22.72%for the three age groups,respectively,with no statistically significant difference among them.The rates of absent c-VEMPs in the affected ears were 8.3%,34.21%,and 18.18%for the three age groups,respectively,with significant differences.In the unaffected ears,there were differences observed in the extraction rates of o-VEMPs in the unaffected ears among the age groups.In the three age groups,no significant differences were noted in the three age groups in the latencies of P1 and N1 waves or in the amplitude of N1–P1 waves for c-VEMPs and o-VEMPs,either on the affected side or on the unaffected side,across the three age groups.CONCLUSION The extraction rate of VEMPs is more valuable than parameters.Regardless of the presence of vertigo,vestibular organs are involved in SSHL.Notably,SSHL patients aged 41–60 appear more susceptible to damage to the inferior vestibular nerve and saccule.
文摘Purpose: This review article provides the readers with an in-depth insight in understanding and interpreting various research literatures on the masseter vestibular evoked myogenic potentials(mVEMP). The article also reviews the contemporary researches involving the clinical applications of the mVEMP. Conclusions: Masseter VEMP is an evolving yet clinically promising neuro-otology test tool that has recently gained more research interest and is considered an additional tool to diagnose various vestibular disorders. Masseter VEMP assesses the functional integrity of the acoustic-masseteric and vestibulo-masseteric reflex pathways. The mVEMP could be used as a complementary test to evaluate the same peripheral generator as the cervical VEMP but a different central pathway i.e., vestibulo-trigeminal pathway. Various research studies that have experimented on parameters such as the effect of different electrode montages(zygomatic vs mandibular configurations), stimulation rates, filter settings and stimuli used to evoke mVEMP have been discussed in this article that could assist in the optimization of a comprehensive clinical protocol. The latency and the amplitude of mVEMP waveforms serve as significant parameters in differentiating normals from those of the clinical populations. Along with the cVEMPs and oVEMPs, mVEMP might help diagnose brainstem lesions in REM Sleep behaviour disorders, Multiple Sclerosis and Parkinson's disease. However, further studies are required to probe in this area of research.
文摘Abnormal SEP reflects dysfunction of the medial lemniscus and posterior cervical cord. These structures are likely to be affected in Chiari malformation. Therefore, SEP abnormalities may provide valuable information in patients with CM. However, the consistency of SEP abnormality or normality with the damage is a matter of research. Knowing whether median nerve somatosensory evoked potential (SEP) is useful in revealing subclinical damage in patients with Chiari malformation is important in the treatment and follow-up plan of the disease. The aim of this study was to investigate the relationship between median nerve SEP values and the severity of cerebellar ectopia in patients with Chiari type 1 malformation. Median nerve SEP values were obtained from 30 healthy individuals and 146 individuals with Chiari malformation. The cerebellar ectopia degree and McRae line length were measured. SEP values were not significantly different between groups. The McRae line was found to be significantly shorter in the control group than in the Chiari malformation group (p = 0.031). There was no correlation between the degree of cerebellar ectopia and the length of the McRae line (r = 0.002, p = 0.979). Neither cerebellar ectopy degree nor McRae line length had a relationship with SEP values (r = -0.153, p = 0.066;r = -0.056, p = 0.500, respectively). There was no difference in cerebellar ectopy degree or SEP values between the groups with cerebellar ectopy with and without a syrinx (p = 0.899;p = 0.080, respectively). Likewise, McRae line length was not found to be related to the presence of a syrinx (p = 0.139). Median nerve SEP examination was not beneficial for diagnosing asymptomatic-oligosymptomatic Chiari malformation as a subclinical injury, whether accompanied by syringomyelia or not.
基金supported by the National Natural Science Foundation of China,No.81871768(to YH)Natural Science Foundation of Tianjin,China,No.18JCYBJC29600(to HYC)High Level-Hospital Program,Health Commission of Guangdong Province,China,No.HKUSZH201902011(to YH)。
文摘The spinal cord is at risk of injury during spinal surgery.If intraoperative spinal co rd injury is identified early,irreve rsible impairment or loss of neurological function can be prevented.Different types of spinal cord injury result in damage to diffe rent spinal cord regions,which may cause diffe rent somatosensory and motor evoked potential signal res ponses.In this study,we examined electrophysiological and histopathological changes between contusion,distra ction,and dislocation spinal cord injuries in a rat model.We found that contusion led to the most severe dorsal white matter injury and caused considerable attenuation of both somatosensory and motor evoked potentials.Dislocation resulted in loss of myelinated axons in the lateral region of the injured spinal cord along the rostrocaudal axis.The amplitude of attenuation in motor evoked potential responses caused by dislocation was greater than that caused by contusion.After distraction injury,extracellular spaces were slightly but not significantly enlarged;somatosensory evoked potential res ponses slightly decreased and motor evoked potential responses were lost.Correlation analysis showed that histological and electrophysiological findings we re significantly correlated and related to injury type.Intraope rative monitoring of both somatosensory and motor evoked potentials has the potential to identify iatrogenic spinal cord injury type during surgery.
基金National Natural Science Foundation of China(No.82160435)。
文摘Objective:To analyze the correlation between the amplitude changes of motor evoked potential(MEP),the 3D volume changes of spinal canal measuring by postoperative CT and the improvement rate of clinical symptoms after the spinal canal decompression in minimally invasive transforaminal lumbar interbody fusion(MIS-TLIF),and to explore the predictive value of the changes of both MEP amplitude and spinal canal volume in the assessment of long-term clinical prognosis in MIS-TLIF.Methods:A retrospective study of 68 patients with L4/5 spinal stenosis treated with MIS-TLIF was performed.The changes of both intraoperative MEP amplitude and 3D spinal canal volume during the spinal canal decompression,as well as the visual analogue scale(VAS)and Oswestry dysfunction index(ODI)scores in the long-term follow-up were all recorded.Results:The values of intraoperative MEP amplitude was 159.04%higher in 68 patients with MIS-TLIF after spinal canal decompression(P<0.01).The 3 postoperative 3D spinal canal volume(4.89±1.27)cm increased by 31.22%in comparison 3 with preoperative date(3.78±1.08)cm(P<0.01).The VAS and ODI scores were improved to 78.55%and 80.60%,respectively at the last follow-up(P<0.01).The improvement rate of MEP amplitude on the decompression side was positively correlated with the improvement rate of postoperative spinal canal volume(r=0.272,P=0.025).The improvement rate of postoperative spinal canal volume was positively correlated with the improvement rate of VAS and ODI at the last follow-up(r=0.656,r=0.490,P<0.01).Moreover,the improvement rate of MEP amplitude on the decompression side was also positively correlated with the improvement rate of VAS and ODI at the last follow-up(r=0.322 and 0.235,respectively,P<0.05).Conclusion:The increase of MEP amplitude after spinal canal decompression in patients with lumbar spinal stenosis treated by MIS-TLIF was closely correlated with both of the increase of spinal canal volume and the improvement of clinical symptoms.Therefore,MEP amplitude monitoring was not only the one of the important monitoring methods for predicting the prognosis of MIS-TLIF but also the reliably predictive value in the long-term clinical prognosis in MIS-TLIF.
基金the National Natural Science Foundation of China(No.30400105);the National Basic Research Development Program(973)(No. 2003CB716106);the National Science Fund for Distinguished Young Scholars of China(No.30525030).
文摘Objective Early researches found that different heartbeat perceivers have different heartbeat evoked potential (HEP)waves.Two tasks were considered in our experiments to get more details about the differences between good and poor heartbeat perceivers at attention and resting state.Methods Thirty channels of electroencephalogram(EEG)were recorded in 22 subjects,who had been subdivided into good and poor heartbeat perceivers by mental tracking task. Principal component analysis(PCA)was applied to remove cardiac field artifact(CFA)from the HEP.Results(1)The good heart-beat perceivers showed difference between attention and resting state in the windows from 250 ms to 450 ms after R wave at C3 location and from 100 ms to 300 ms after R wave at C4 location;(2)The difference waveforms between good and poor heartbeat perceivers was a positive waveform at FZ from 220 ms to 340 ms after R wave,which was more significant in attention state.Conclusion Attention state had more effect on the HEPs of good heartbeat perceivers than that of poor heartbeat perceivers;and perception ability influenced HEPs more strongly in the attention state than in the resting state.
基金Project supported by the National Key Research and Development Program of China(Grant Nos.2016YFA0300600 and 2016YFA0301500)the Strategic Priority Research Program of Chinese Academy of Sciences(Grant Nos.XDB07030000 and XDBS32000000)+1 种基金the National Natural Science Foundation of China(Grant Nos.11474347 and 31730039)the Fund from the Ministry of Science and Technology of China(Grant No.2015CB351701)
文摘We observed the steady-state visually evoked potential(SSVEP) from a healthy subject using a compact quad-channel potassium spin exchange relaxation-free(SERF) optically pumped magnetometer(OPM). To this end, 30 s of data were collected, and SSVEP-related magnetic responses with signal intensity ranging from 150 fT to 300 f T were observed for all four channels. The corresponding signal to noise ratio(SNR) was in the range of 3.5–5.5. We then used different channels to operate the sensor as a gradiometer. In the specific case of detecting SSVEP, we noticed that the short channel separation distance led to a strongly diminished gradiometer signal. Although not optimal for the case of SSVEP detection, this set-up can prove to be highly useful for other magnetoencephalography(MEG) paradigms that require good noise cancellation.Considering its compactness, low cost, and good performance, the K-SERF sensor has great potential for biomagnetic field measurements and brain-computer interfaces(BCI).
文摘Aim: Extensive neurophysiological investigations were carried out in 100 healthy subjects and 84 patients with penileerectile dysfunction. Methods: Following examinations were performed, spinal and scalp somatosensory evoked poten-tials (SEPs) to stimulation of the dorsal nerve of penis, motor evoked potentials (MEPs) from bulbocavernosus (BC) inresponse to scalp and spinal root stimulation, and measurement of sacral reflex latency (SRL) from anal sphincter (AS).Results: In the healthy subjects, the mean sensory total conduction time (sensory TCT), as measured at the peak of thescalp P1 (P40) wave was 39.73 ms. The mean sensory central conduction time (sensory CCT = spinal-to-scalp conductiontime) was 28.98 ms. The mean peripheral conduction time (PCP) was 9.40 ins. Transcranial brain stimulation was per-formed by using a magnetic stimulator during voluntary contraction of the examined muscle. Spinal root stimulation wasperformed at rest. Motor total conduction time (motor TCT) to BC muscles was 20.48 ms. Motor central conductiontime (motor CCT) to sacral cord segments controlling BC muscles was 14.42 ms at rest. The mean SRL was 35.13 ms.Conclusion: Combined or isolated abnormalities of SEPs, MEPs, and SRL were found in patients with erectile dysfunc-tion. (Asian J Androl 1999 Sep; 1 : 145 - 150)
基金funded by Zhejiang Medicines &Health Sciences Research Fund (Class A) in 2009, No.2009A086
文摘A total of 43 prolonged coma patients with diffuse axonal injury received the somatosensory evoked potential examination one month after injury in the First Affiliated Hospital, School of Medicine, Zhejiang University in China. Somatosensory evoked potentials were graded as normal, abnormal or absent (grades I-III) according to N20 amplitude and central conduction time. The outcome in patients with grade III somatosensory evoked potential was in each case unfavorable. The prognostic accuracy of grade III somatosensory evoked potential for unfavorable and non-awakening outcome was 100% and 80%, respectively. The prognostic accuracy of grade I somatosensory evoked potential for favorable and wakening outcome was 86% and 100%, respectively. These results suggest that somatosensory evoked potential grade is closely correlated with coma severity and degree of recovery. Somatosensory evoked potential is a valuable diagnostic tool to assess prognosis in prolonged coma patients with diffuse axonal injury.
基金supported by the National Natural Science Foundation of China,No.81101370,81101399,81272018the Natural Science Foundation of Jiangsu Province in China,No.BK2011303+2 种基金Jiangsu Province Science and Technology Support Program(Social Development)in China,No.BE2011672University Natural Science Research Foundation of Jiangsu Province for Higher Education,No.12KJB320008College Graduate Research and Innovation Plan of Jiangsu Province in China,No.CXZZ11_0126
文摘It remains unclear whether spinal cord ischemia-reperfusion injury caused by ischemia and other non-mechanical factors can be monitored by somatosensory evoked potentials. Therefore, we monitored spinal cord ischemia-reperfusion injury in rabbits using somatosensory evoked potential detection technology. The results showed that the somatosensory evoked potential latency was significantly prolonged and the amplitude significantly reduced until it disappeared during the period of spinal cord ischemia. After reperfusion for 30-180 minutes, the amplitude and latency began to gradually recover; at 360 minutes of reperfusion, the latency showed no significant difference compared with the pre-ischemic value, while the somatosensory evoked potential amplitude in- creased, and severe hindlimb motor dysfunctions were detected. Experimental findings suggest that changes in somatosensory evoked potentia~ ~atency can reflect the degree of spinat cord ischemic injury, while the amplitude variations are indicators of the late spinal cord reperfusion injury, which provide evidence for the assessment of limb motor function and avoid iatrogenic spinal cord injury.
文摘In this study, we aimed to study the pattern visual evoked potentials (P-VEPs) in two eyes with varying visual acuity in one eye and to provide an objective estimation of visual acuity by comparing P-VEPs in one and two eyes. Thirty subjects were chosen, who had one eye with an acuity of 5.0, 4.85, 4.6, 4.0, or scieropia and obstructed vision and the other eye with an acuity of 5.0, respectively. P-VEPs were detected under the large grating stimuli at 3x4 spatial frequency, moderate grating stimuli (12× 16 spatial frequency) and small grating stimuli (48×64 spatial frequency). Under large grating stimuli, there was no significant difference in P100 peak latency between the groups, nor was there a significant difference between the amplitude of two eyes and the amplitude of one normal-vision eye. Under moderate and small grating stimuli, there was a significant difference in P100 peak latency between the group with both eyes having an acuity of 5.0 and the group with visual acuity below 4.0 in one eye. There was a significant difference in P100 amplitude between the group with visual acuity of 5.0 in both eyes and the group with one normal-vision eye. There was no significant difference in the amplitude of two eyes and the amplitude of one normal-vision eye between any other two groups. In forensic identification, characteristics and variability of P-VEPs in one and two eyes can be used to identify malingering or decline in visual acuity.
基金Supported by the Plan of Wenzhou Science and Technology(No.Y20160439)
文摘AIM:To compare the diagnostic performance of isolatedcheck visual evoked potential(ic VEP) and standard automated perimetry(SAP),for evaluating the application values of ic VEP in the detection of early glaucoma.METHODS:Totally 144 subjects(288 eyes) were enrolled in this study.ic VEP testing was performed with the Neucodia visual electrophysiological diagnostic system.A 15% positive-contrast(bright) condition pattern was used in this device to differentiate between glaucoma patients and healthy control subjects.Signal-to-noise ratios(SNR) were derived based on a multivariate statistic.The eyes were judged as abnormal if the test yielded an SNR≤1.SAP testing was performed with the Humphrey Field Analyzer II.The visual fields were deemed as abnormality if the glaucoma hemifield test results outside normal limits;or the pattern standard deviation with P〈0.05;or the cluster of three or more non-edge points on the pattern deviation plot in a single hemifield with P〈0.05,one of which must have a P〈0.01.Disc photographs were graded as either glaucomatous optic neuropathy or normal by two experts who were masked to all other patient information.Moorfields regression analysis(MRA) used as a separate diagnostic classification was performed by Heidelberg retina tomograph(HRT).RESULTS:When the disc photograph grader was used as diagnostic standard,the sensitivity for SAP and ic VEP was 32.3% and 38.5% respectively and specificity was 82.3% and 77.8% respectively.When the MRA Classifier was used as the diagnostic standard,the sensitivity for SAP and ic VEP was 48.6% and 51.4% respectively and specificity was 84.1% and 78.0% respectively.When the combined structural assessment was used as the diagnostic standard,the sensitivity for SAP and ic VEP was 59.2%and 53.1% respectively and specificity was 84.2% and 84.6% respectivlely.There was no statistical significance between the sensitivity or specificity of SAP and ic VEP,regardless of which diagnostic standard was based on.CONCLUSION:The diagnostic performance of ic VEP is not better than that of SAP in the detection of early glaucoma.
基金the National Natural Science Foundation of China, No.30973720the Science Research Foundation of Ministry of Health & United Fujian Provincial Health and Education Project for Tackling the Key Research of China, No.WKJ2005-2-004
文摘The peripheral driver stimulating theory states that as a driver passes along a certain meridian during acupuncture; the driver provokes nerve sense devices along the meridian, resulting in the nerve impulse entering the central nervous system. Accordingly, volunteers have reported propagated sensations along the meridians (PSM). The present study was designed to utilize a cortical somatosensory-evoked potential (CSEP) topographic map for determining whether stimulation expansion occurs in somatosensory area I when sensation was provoked in individuals with obvious PSM. The sensation was blocked by mechanical compression, and the sensation was imitated in individuals without PSM. Results revealed a red, high-potential signal in the representative area of the lower limbs in individuals with obvious PSM symptoms when the Gall Bladder Meridian (GBM) sensation passed to the head and face. This representative area was near the middle line of the CSEP topographic map, and a red, high-potential signal, which jumps over the representative area of the upper limbs, also appeared in the representative face area, which was at the external region of the CSEP topographic map. However, in individuals exhibiting no PSM, only a red high-potential signal appeared in the representative lower limb area. When Hegu (LI 4) was stimulated in individuals without PSM, an obvious evoked response appeared only in the representative upper limb area. However, when Hegu was stimulated in individuals exhibiting PSM, the response area was larger in the representative upper limb area and extended to the representative face area. When Guangrning (GB 37) was stimulated in PSM individuals, the face representation response disappeared and was confined to a foot representation of the somatosensory area I when PSM was blocked by mechanical pressure. Results suggested that mechanical compression blocked PSM, and corresponding changes were exhibited in the CSEP topographic map. These results provide compelling evidence for the hypothesis that peripheral driver stimulation is the key element in producing PSM.
基金Supported by the Research Foundation of Akdeniz University, Turkey
文摘AIM: To evaluate the effect of sodium tungstate on visual evoked potentials(VEPs) in diabetic rats.· METHODS: Wistar rats were randomly divided into three groups as normal control, diabetic control and diabetic rats treated with sodium tungstate. Diabetes was induced by single intraperitoneal injection of streptozotocin(50 mg/kg). Sodium tungstate [40 mg/(kg·d)]was administered for 12 wk and then VEPs were recorded.Additionally, thiobarbituric acid reactive substance(TBARS) levels were measured in brain tissues.·RESULTS: The latencies of P1, N1, P2, N2 and P3 waves were significantly prolonged in diabetic rats compared with control group. Diabetes mellitus caused an increase in the lipid peroxidation process that was accompanied by changes in VEPs. However, prolonged latencies of VEPs for all components returned to control levels in sodium tungstate-treated group. The treatment of sodium tungstate significantly decreased brain TBARS levels and depleted the prolonged latencies of VEP components compared with diabetic control group.· CONCLUSION: Sodium tungstate shows protective effects on visual pathway in diabetic rats, and it can be worthy of further study for potential use.
文摘Visual evoked potentials (VEPs) are a series of signals about visual occipital cortex in response to visual stimuli and can be used as one of ob-jective non-invasive neuro-physiological pa-rameters to reflect the visual organs and central visual pathway’s functional integrity. Previous studies have shown that acute and chronic ex-ercise could affect VEPs independent from body temperature and other physiological parameters. VEPs may well be used as neuro-physiological criteria in defining the performances of the ath-letes. Different sports training have different effects on VEPs, but the results are not consis-tent. P100 latency is the representative compo-nent of VEPs and it is of high, steady amplitude and of slight intra- and inter-individual variabil-ity so that the index is most commonly used. The purpose of this study was to investigate the specificity and sensitivity of P100 latency to dif-ferent physical activities. The neural electricity device of NDI-200 was used to measure the pattern reversal VEPs of all subjects, including the values of the resting state before and after different events exercise. Different events exer-cise contained an aerobic cycloergometric ex-ercise (7 subjects were conducted to a Bruce Graded Exercise Test on the Monark Ergomedic 839E cycloergometer, THR (target heart rate) = 85% HRmax, 3 times/week, about 10 minutes once time, 6 weeks), tennis training (16 volun-teers, 2 hours/day, 3 days/week, 8 weeks), aerobic Latin exercise (7 subjects, 1 hour/day, 3 days/week, 6 weeks) and the Baduanjin of Health Qigong training (6 subjects, 1 hour/day, 3 days/week, 6 weeks). The VEPs recordings of the control groups obtained synchronized with the experimental groups. SPSS 11.5 for win-dows was used for statistical analysis. A level of P﹤0.05 was accepted as statistically significant. The VEPs P100 latency of post-exercise of all experimental groups except Baduanjin group became shorter significantly compared with those of pre-exercise (P﹤0.05). No significant difference was found between pre-and post- exercise for the control groups. This study showed that exercise could shorten the P100 la-tency significantly. Moreover, it also indicated that VEPs were sensitive to exercise to a certain extent. We concluded that VEPs might well be used as neuro-physiological criteria in defining the performances of the athletes. It was found that the VEPs P100 latency became shorter after most training programs;furthermore, it demon-strated that P100 latency of VEPs had little specificity to different events.
文摘BACKGROUND: Pattern- visual evoked potential (PVEP) can reflect the functional status of retinal ganglial cells (RGC) and visual cortex, and is an objective examination for visual pathway function. It is a unique method for objectively examining the optic nerve function of optic ganglion cells. OBJECTIVE: To observe the effects of nerve growth factor (NGF) on PVEF in the treatment of optic nerve contusion, evaluate the clinical efficacy of NGF, and make an efficacy comparison with vitamin B12. DESIGN: A randomly grouping, controlled observation. SETTING: Department of Ophthalmology, Tangshan Gongren Hospital Affiliated to Hebei Medical University. PARTICIPANTS: Forty patients with optic nerve contusion caused by eye trauma, who received the treatment in the Tangshan Worker Hospital Affiliated to Hebei Medical University between January 2006 and June 2007, were recruited in this study. The involved 40 patients, including 34 males and 6 females, were aged 14-59 years. They were confirmed to have optic nerve contusion by ophthalmologic consultation combined with history of disease and orbital CT examination. Informed consents of treatments and detected items were obtained from all the patients. The patients were randomly divided into 2 groups with 20 in each: NGF group and vitamin B12 group. METHODS: Conservative treatment was used in the two groups. In addition, patients in the NGF group were intramuscularly injected with NGF solution 18 μg /time, once a day. Those in the vitamin B12 group were injected by the same method with common vitamin B12 of 500 μg combined with vitamin B1 of 100 mg, once a day. MAIN OUTCOME MEASURES: PVEP examination was conducted in all the patients before, one and two weeks after treatment, and latency and amplitude at P100 were detected. RESULTS: Forty patients with optic nerve contusion participated in the final analysis. Before treatment, significant differences in the latency and amplitude at P100 were not found in patients between two groups (P 〉 0.05). For each patient in the NGF group, the latency of PVEP at P100 was significantly shortened, and the amplitude was significantly increased one and two weeks after treatment as compared with vitamin B12 group(t =2.06-2.34, P 〈 0.05). CONCLUSION: NGF treatment can obviously improve the visual function of patients with optic nerve contusion. The curative effect of NGF is superior to vitamin B12.
文摘Aim: The effect of a renewed SS-cream (RSSC) on the treatment of premature ejaculation (PE) was evaluated and compared with the original SS-cream (OSSC). Methods: Sixty male white New Zealand rabbits, weighing 2.5kg-3.0 kg, were divided at random into 3 groups: the RSSC, OSSC and placebo groups. The spinal somatosensory evoked potential (SSEP) elicited by electric stimulation of the glans penis with disk electrode was investigated with an electrophysiograph (Poseidomn, Shanghai, China) before and 10, 30 and 60 min after drug or placebo application on the glans. The Onset and the N1 latencies and the amplitude of SSEP were recorded and analyzed. Results: There was no significant difference (P>0.05) in the mean Onset and Nl latency of SSEP among the 3 groups before drug application. Compared with the pre-application value, the mean Onset and Nl latencies in the RSSC and OSSC groups were significantly prolonged at 10, 30 and 60 min after treatment (P<0.05), while they were not significantly changed (P>0.05) in the placebo group. The mean Onset latency of RSSC at 10 and 30 min and that of OSSC at 30 min were significantly delayed (P<0.05) compared with the placebo group. The mean Nl latency of RSSC at 30 and 60 min and that of OSSC group at 30 min were also significantly delayed (P<0.05). Conclusion: RSSC delays the latencies of SSEP, suggesting a local desensitizing effect on the sensory receptor of the glans penis dorsal nerve, which provides the potential for PE treatment. The desensitizing effect of RSSC is higher than that of OSSC.
文摘 Under the auditory evoked brain stem potential (ABP) examination, the latent period of V wave and the intermittent periods of III-V peak and I-V peak were significantly shortened in Parkinson's disease patients of the treatment group (N=29) after acupuncture treatment. The difference of cumulative scores in Webster's scale was also decreased in correlation analysis. The increase of dopamine in the brain and the excitability of the dopamine neurons may contribute to the therapeutic effects, in TCM terms, of subduing the pathogenic wind and tranquilizing the mind.……
文摘The effects of acupuncture on the sensory evoked cortical potentials were investigated in 31 rabbits anaesthetized with urethane of conscious, so as to see what happened to the functional state of cerebral cortex in the meantime. The visual, auditory and somatosensory evoked potentials as well as raw EEGs were recorded from the animal’s scalp. In most cases, an electro-acupuncture instrument was used instead of manual acupuncture. The main component amplitudes of evoked potentials,the frequency band powers and the total integral values of raw EEGs were analyzed. Results showed that during acupuncture the main components of evoked potentials were significantly depressed and the raw EEGs appeared desynchronized while the experimental animals were slightly activated. Moreover,both the total integral values of raw EEGs and the powers of lower frequency waves (1 - 3. 99 Hz)were decreased and positively correlated well with the amplitudes of main components of the evoked potentials. Therefore, the possibility that the effects of acupuncture on the evoked potentials are secondary to the changes of raw EEGs remains to be ruled out, and it is suggested that the inhibition of evoked potentials during acupuncture does not necessarily mean that the cerebral cortex is in an inhibitory
基金supported by grants from the National Basic Research Program of China (973 Program)(#2012CB967900)National Natural Science Foundation of China (31300624,81470684)+3 种基金Postdoctoral Science Foundation of China (2015M571818)Six Major Categories of Talent (2014-WSN043,2011-WS-074)Innovation and Entrepreneurship Training Program for College Students in Jiangsu Province(201510313003Z,201510313003,KYLX14-1455)Clinic Medical Special Foundation of Jiangsu Province (b12014032)
文摘Objective:To report vestibular evoked myogenic potentials from different recording sites(neck extensor or masseter muscles) in miniature pigs and rats.Methods:Potentials were recorded using 1000 Hz tone bursts from the neck extensor muscle or masseter muscle in normal adult Bama miniature pigs and rats anesthetized with 3%pentobarbital sodium and Sumianxin Ⅱ.Results:At 80 dB SPL,the first positive wave(P wave) of VEMPs was recognizable in 58%of rats with a latency of 6.45±0.23 ms and an amplitude of 1.45±0.49 μV when recorded from the neck extensor muscle,and in 50%of rats with a latency of 6.38±0.34 ms and an amplitude of 1.57±0.35 μV when recorded from the masseter muscle.In miniature pigs,at the same stimulus intensity,P wave was recognizable in 58%of the animals with a latency of 7.65±0.64 ms and an amplitude of 1.66±0.34 μV when recorded from the neck extensor muscle,and in 50%of the animals with a latency of 7.65±0.64 ms and an amplitude of 0.31±0.28 μV when recorded from the masseter muscle.Conclusion:VEMP can be induced from both neck extensor and masseter muscles in the miniature pig and rat.For a given species,the site of recording affects P wave induction rate and amplitude but not latency.Consistency and repeatability analysis suggests that the masseter muscle is a better recording site in miniature pigs while the cervical extensor is a better recording site in rats.For a given recording site,both latency and amplitude of the P wave are slightly greater in miniature pigs than in rats.