期刊文献+
共找到18篇文章
< 1 >
每页显示 20 50 100
Analysis of influencing factors of excitation parameters for magnetoacoustic tomography with current injection 被引量:2
1
作者 李粟 刘国强 +3 位作者 郭亮 张文伟 卢朝森 夏慧 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第5期496-503,共8页
Magneto-acoustic tomography with current injection(MAT-CI) is a type of hybrid imaging;under the excitation of the static magnetic field, the thermoacoustic effect and the Lorentz force effect will exist at the same t... Magneto-acoustic tomography with current injection(MAT-CI) is a type of hybrid imaging;under the excitation of the static magnetic field, the thermoacoustic effect and the Lorentz force effect will exist at the same time. Therefore,the detected signal is a mixed signal generated by the simultaneous action of the two effects, but the influence of excitation parameters on the two effects is different. In this paper, for objects with different conductivity, the proportion of thermoacoustic signal(TA) and magneto-acoustic signal(MA) in the mixed signal is quantitatively analyzed in terms of three aspects: the magnetic induction intensity, pulse excitation and injection current polarity. Experimental and simulation analyses show that the intensity ratio of MA to TA is not affected when the conductivity varies from 0.1 S/m to 1.5 S/m and other conditions remain unchanged. When the amplitude of the pulse excitation and the strength of the magnetic induction are different, the growth rates of MA and TA are different, which has a significant impact on the proportion of the two signals in the mixed signal. At the same time, due to the Lorentz force effect, MA is affected by the polarity of the injected current and the direction of the static magnetic field. The combination of the static magnetic field and the injected current can not only distinguish the two signals in the mixed signal, but also effectively enhance the intensity of the mixed signal and improve the quality of the reconstructed image. 展开更多
关键词 magneto-acoustic tomography with current injection(MAT-CI) thermoacoustic effect Lorentz force effect acoustic source
下载PDF
Research on Open-circuit Fault Tolerant Control of Six-phase Permanent Magnet Synchronous Machine Based on Fifth Harmonic Current Injection 被引量:3
2
作者 Zhifeng Zhang Yue Wu +1 位作者 Hequn Su Quanzeng Sun 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第3期306-314,共9页
This paper proposes a novel control approach for fault-tolerant control of dual three-phase permanent magnet synchronous motor(PMSM) under one-phase open-circuit fault.A modified six-phase static coordinate transforma... This paper proposes a novel control approach for fault-tolerant control of dual three-phase permanent magnet synchronous motor(PMSM) under one-phase open-circuit fault.A modified six-phase static coordinate transformation matrix and an extended rotating coordinate transformation matrix are investigated considering the influence of the fifth harmonic space on fault-tolerant control. These mathematical models are further analyzed in the fundamental space and the fifth harmonic space after the fault and to eliminate the coupling between the d-q axis voltage equation in the fundamental wave space and the d-q axis voltage equation in the fifth harmonic space, a secondary rotation coordinate transformation matrix is proposed. To achieve the purpose of reducing torque ripple, the fault-tolerant control method proposed in this paper not only takes the minimum copper loss as the constraint condition, but also injects the fifth harmonic current. The experimental result of current and torque is used to verify the accuracy of fault-tolerant control. 展开更多
关键词 Extended rotating coordinate transformation matrix Fault-tolerant control Fifth harmonic current injection Modified six-phase static coordinate transformation matrix Dual three-phase permanent magnet synchronous motor Torque ripple
下载PDF
Accurate capacitance-voltage characterization of organic thin films with current injection
3
作者 Ming Chu Shao-Bo Liu +8 位作者 An-Ran Yu Hao-Miao Yu Jia-Jun Qin Rui-Chen Yi Yuan Pei Chun-Qin Zhu Guang-Rui Zhu Qi Zeng Xiao-Yuan Hou 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第8期462-468,共7页
To deal with the invalidation of commonly employed series model and parallel model in capacitance-voltage(C-V)characterization of organic thin films when current injection is significant,a three-element equivalent cir... To deal with the invalidation of commonly employed series model and parallel model in capacitance-voltage(C-V)characterization of organic thin films when current injection is significant,a three-element equivalent circuit model is proposed.On this basis,the expression of real capacitance in consideration of current injection is theoretically derived by small-signal analysis method.The validity of the proposed equivalent circuit and theoretical expression are verified by a simulating circuit consisting of a capacitor,a diode,and a resistor.Moreover,the accurate C-V characteristic of an organic thin film device is obtained via theoretical correction of the experimental measuring result,and the real capacitance is 35.7%higher than the directly measured capacitance at 5-V bias in the parallel mode.This work strongly demonstrates the necessity to consider current injection in C-V measurement and provides a strategy for accurate C-V characterization experimentally. 展开更多
关键词 current injection organic thin film CAPACITANCE-VOLTAGE parasitic resistance
下载PDF
Adaptive restarting method for LCC-HVDC based on principle of fault location by current injection 被引量:2
4
作者 Ruidong Xu Guobing Song +1 位作者 Junjie Hou Zhongxue Chang 《Global Energy Interconnection》 EI CAS CSCD 2021年第6期554-563,共10页
The existing LCC-HVDC transmission project adopts the fixed-time delay restarting method.This method has disadvantages such as non-selectivity,long restart process,and high probability of restart failure.These issues ... The existing LCC-HVDC transmission project adopts the fixed-time delay restarting method.This method has disadvantages such as non-selectivity,long restart process,and high probability of restart failure.These issues cause a secondary impact on equipment and system power fluctuation.To solve this problem,an adaptive restarting method based on the principle of fault location by current injection is proposed.First,an additional control strategy is proposed to inject a current detection signal.Second,the propagation law of the current signal in the line is analyzed based on the distributed parameter model of transmission line.Finally,a method for identifying fault properties based on the principle of fault location is proposed.The method fully considers the influence of the long-distance transmission line with earth capacitance and overcomes the influence of the increasing effect of the opposite terminal.Simulation results show that the proposed method can accurately identify the fault properties under various complex fault conditions and subsequently realize the adaptive restarting process. 展开更多
关键词 LCC-HVDC Adaptive restarting current signal injection Fault location Fault property identification
下载PDF
Harmonic Circulating Current Injection Based Power Loss Optimization Control of Bottom Switch/Diodes for Modular Multilevel Converters 被引量:2
5
作者 Jifeng Zhao Fujin Deng +3 位作者 Chengkai Liu Qiang Yu Qingsong Wang Jianzhong Zhang 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第6期1213-1226,共14页
Power loss management is one of the most significant challenges for reliability improvement of modular multilevel converters(MMCs).In the MMC,the bottom switch/diode in each submodule(SM)normally takes the maximum pow... Power loss management is one of the most significant challenges for reliability improvement of modular multilevel converters(MMCs).In the MMC,the bottom switch/diode in each submodule(SM)normally takes the maximum power loss.In this paper,a power loss optimization control(PLOC)for MMCs is proposed,where the maximum power losses in the bottom switch/diode of each SM can be effectively reduced through injecting optimum second-order harmonic current into the circulating current of MMCs,and accordingly the reliability of MMCs can be improved by the proposed PLOC.Simulation results with PSCAD software and experimental results with a 1 kW MMC platform are provided to confirm the validity of the proposed PLOC for MMCs. 展开更多
关键词 Circulating current injection modular multilevel converters optimization power losses RELIABILITY
原文传递
Current Injection Provokes Rapid Expansion of the Guard Cell Cytosolic Volume and Triggers Ca^2+ Signals
6
作者 Lena J. Voss Rainer Hedrich M. Rob G. Roelfsema 《Molecular Plant》 SCIE CAS CSCD 2016年第3期471-480,共10页
High-resolution microscopy opens the door for detailed single-cell studies with fluorescent reporter dyes and proteins. We used a confocal spinning disc microscope to monitor fluorescent dyes and the fluorescent prote... High-resolution microscopy opens the door for detailed single-cell studies with fluorescent reporter dyes and proteins. We used a confocal spinning disc microscope to monitor fluorescent dyes and the fluorescent protein Venus in tobacco and Arabidopsis guard cells. Multi-barreled microelectrodes were used to inject dyes and apply voltage pulses, which provoke transient rises in the cytosolic Ca^2+ level. Voltage pulses also caused changes in the distribution of Lucifer Yellow and Venus, which pointed to a reversible increase of guard cell cytosolic volume. The dynamic cytosolic volume changes turned out to be provoked by current injection of ions. A reduction of the clamp current, by blocking K^+ uptake channels with Cs^+, strongly suppressed the cytosolic volume changes. Cs^+ not only inhibited the expansion of the cytosol, but also inhibited hyperpolarization-induced elevations of the cytosolic Ca^2+ concentration. A complete loss of voltage-induced Ca^2+ signals occurred when Ca^2+-permeable plasma membrane channels were simultaneously blocked with La^3+. This shows that two mechanisms cause hyperpolarization-induced elevation of the cytosolic Ca^2+-concentration: (i) activation of voltage-dependent Ca^2+-permeable channels, (ii) osmotically induced expansion of the cytosol, which leads to a release of Ca^2+ from intracellular stores. 展开更多
关键词 guard cell cytosolic Ca^2+ cytosolic volume voltage clamp current injection ion channel
原文传递
Phasor-domain Dynamic Model of Asymmetric Current Injection Controller for Converter-interfaced Generator
7
作者 Victor A.F.Almeida Glauco N.Taranto José M.T.Marinho 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第6期1269-1278,共10页
This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square(RMS)phasor-domain,fundamentalfrequency,three-phase,and dynamic simulation tools.... This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square(RMS)phasor-domain,fundamentalfrequency,three-phase,and dynamic simulation tools.The effectiveness of the proposed controller is assessed with simulations in test systems with high percentage of converter-interfaced generation.The simulations focus on the operation of protection relays that use negative-sequence quantities in their directional elements.This paper also presents and compares two strategies to limit reactive negative-sequence currents,and active and reactive positive-sequence currents.A tutorial test system and a regional system part of the actual Brazilian Interconnected Power System are used to assess the correctness of the proposed controller in three-phase fundamental-frequency RMS dynamic simulations. 展开更多
关键词 Converter-interfaced generator three-phase model power system protection negative-sequence current injection negative-sequence current protection unbalanced fault three-phase root-mean-square(RMS)dynamic simulation
原文传递
Spin polarized current injection and transportation in a double T-shaped organic spintronic device
8
作者 REN JunFeng SONG RuiRong +1 位作者 YUAN XiaoBo HU GuiChao 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS CSCD 2015年第3期71-75,共5页
A double T-shaped device model is constructed to investigate the spin polarized current injection and transportation properties in organic semiconductors.Based on the spin diffusion theory and Ohm’s law and consideri... A double T-shaped device model is constructed to investigate the spin polarized current injection and transportation properties in organic semiconductors.Based on the spin diffusion theory and Ohm’s law and considering the different charge-spin relationship of the special carriers in organic semiconductors,the current spin polarization has been obtained.Effects of the branch current ratio and the polaron proportion on the spin polarized current injection efficiency are studied.From the calculation,it is found that the improvement of the spin polarized current injection efficiency can be obtained by adjusting the branch current ratio;moreover,high polaron proportion in organic semiconductors is beneficial for obtaining high current spin polarization. 展开更多
关键词 organic spintronics spin polarized current injection current spin polarization
原文传递
Rashba spin-orbit coupling induced rectified currents in monolayer graphene with exchange field and sublattice potential
9
作者 陈亮 李峰 丁晓明 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第8期382-385,共4页
We investigate the effect of Rashba spin-orbit coupling(RSOC)on photoconductivities of rectified currents in monolayer graphene with exchange field and sublattice potential.The system shows that the photoconductivitie... We investigate the effect of Rashba spin-orbit coupling(RSOC)on photoconductivities of rectified currents in monolayer graphene with exchange field and sublattice potential.The system shows that the photoconductivities of resonant shift and injection current contributions are nonzero,while the photoconductivities of non-resonant shift current contribution are zero.We find that the RSOC induces a warping term,which leads to the nonzero rectified currents.Moreover,the photoconductivities of resonant injection(shift)current contribution are(not)related to the relaxation rate.The similar behavior can be found in other Dirac materials,and our findings provide a way to tune the nonlinear transport properties of Dirac materials. 展开更多
关键词 GRAPHENE spin orbit coupling shift current inject current
下载PDF
Development of data acquisition and over-current protection systems for a suppressor-grid current with a neutral-beam ion source
10
作者 刘伟 胡纯栋 +5 位作者 刘胜 宋士花 汪金新 王艳 赵远哲 梁立振 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第12期154-158,共5页
Neutral beam injection is one of the effective auxiliary heating methods in magnetic-confinementfusion experiments. In order to acquire the suppressor-grid current signal and avoid the grid being damaged by overheatin... Neutral beam injection is one of the effective auxiliary heating methods in magnetic-confinementfusion experiments. In order to acquire the suppressor-grid current signal and avoid the grid being damaged by overheating, a data acquisition and over-current protection system based on the PXI(PCI e Xtensions for Instrumentation) platform has been developed. The system consists of a current sensor, data acquisition module and over-current protection module. In the data acquisition module,the acquired data of one shot will be transferred in isolation and saved in a data-storage server in a txt file. It can also be recalled using NBWave for future analysis. The over-current protection module contains two modes: remote and local. This gives it the function of setting a threshold voltage remotely and locally, and the forbidden time of over-current protection also can be set by a host PC in remote mode. Experimental results demonstrate that the data acquisition and overcurrent protection system has the advantages of setting forbidden time and isolation transmission. 展开更多
关键词 neutral beam injection high-current ion source suppression grid current data acquisition and protection system
下载PDF
Location of Asymmetric Ground Fault Using Virtual Injected Current Ratio and Two-stage Recovery Strategy in Distribution Networks
11
作者 Haiting Shan Luliang Zhang +1 位作者 Q.H.Wu Mengshi Li 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第1期151-161,共11页
Sparse measurements challenge fault location in distribution networks.This paper proposes a method for asymmetric ground fault location in distribution networks with limited measurements.A virtual injected current vec... Sparse measurements challenge fault location in distribution networks.This paper proposes a method for asymmetric ground fault location in distribution networks with limited measurements.A virtual injected current vector is formulated to estimate the fault line,which can be reconstructed from voltage sags measured at a few buses using compressive sensing(CS).The relationship between the virtual injected current ratio(VICR)and fault position is deduced from circuit analysis to pinpoint the fault.Furthermore,a two-stage recovery strategy is proposed for improving reconstruction accuracy of the current vector,where two different sensing matrixes are utilized to improve the incoherence.The proposed method is validated in IEEE 34 node test feeder.Simulation results show asymmetric ground fault type,resistance,fault position and access of distributed generators(DGs)do not significantly influence performance of our method.In addition,it works effectively under various scenarios of noisy measurement and line parameter error.Validations on 134 node test feeders prove the proposed method is also suitable for systems with more complex structure. 展开更多
关键词 Distribution networks fault location reconstruction accuracy two-stage recovery virtual injected current ratio
原文传递
Rectifier Configurations Based on Harmonic Injecting and Counteracting Principle
12
作者 何丹 戴先中 +1 位作者 肖仁良 徐以荣 《Journal of Southeast University(English Edition)》 EI CAS 1999年第1期81-88,共8页
On the basis of detailed analysis of a novel harmonic counteracting method which can be used to effectively compensate the supply line harmonic currents of a passive single phase diode bridge rectifier, this paper pr... On the basis of detailed analysis of a novel harmonic counteracting method which can be used to effectively compensate the supply line harmonic currents of a passive single phase diode bridge rectifier, this paper presents two simpler single phase diode bridge rectifier configurations and their alternatives which can achieve low supply line current THD(total harmonic distortion) too. Moreover, this paper also proposes a few passive hamonic counteracting networks for multi single phase rectifiers which are connected in parallel. 展开更多
关键词 single phase rectifier harmonic compensation current injection THD
下载PDF
Research on Torque Ripple Under Healthy and Open-Circuit Fault-Tolerant Conditions in a PM Multiphase Machine 被引量:4
13
作者 Ali Akay Paul Lefley 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期349-359,共11页
In this paper,research into torque ripple production has been undertaken for both the healthy and open-circuit faulttolerant conditions of a five-phase permanent magnet(PM)machine by using the instantaneous power(I-Po... In this paper,research into torque ripple production has been undertaken for both the healthy and open-circuit faulttolerant conditions of a five-phase permanent magnet(PM)machine by using the instantaneous power(I-Power)approach.When only the fundamental component of the phase currents is applied to the phase windings,it has been shown that the 9th and 11th harmonics of the back-electromotive force(back-EMF)causes torque ripples in a five-phase PM machine and its frequency is ten times the frequency of the fundamental phase currents.When the combined fundamental and third harmonic components of the phase currents are applied to the phase windings,it has been shown that the 7th and 13th harmonic of the back-electromotive force(back-EMF)causes additional torque ripples in a five-phase PM machine.These torque ripples under fault-tolerant conditions have been analyzed analytically,as well.It has been proven that there are interactions between the fundamental component of current and the third harmonic component of the back-EMF and vice versa.These interactions cause torque ripples.A finite element analysis(FEA)model of the five-phase PM machine has been done to validate the analytical results. 展开更多
关键词 Five-phase harmonic current injection multiphase machine permanent magnet machine torque ripple
下载PDF
Characterization of Al_2O_3 /GaN/AlGaN/GaN metalinsulator-semiconductor high electron mobility transistors with different gate recess depths
14
作者 马晓华 潘才渊 +6 位作者 杨丽媛 于惠游 杨凌 全思 王昊 张进成 郝跃 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第2期458-464,共7页
In this paper, in order to solve the interface-trap issue and enhance the transconductance induced by high-k dielectric in metal-insulator-semiconductor (MIS) high electron mobility transistors (HEMTs), we demonst... In this paper, in order to solve the interface-trap issue and enhance the transconductance induced by high-k dielectric in metal-insulator-semiconductor (MIS) high electron mobility transistors (HEMTs), we demonstrate better performances of recessed-gate A1203 MIS-HEMTs which are fabricated by Fluorine-based Si3N4 etching and chlorine- based A1CaN etching with three etching times (15 s, 17 s and 19 s). The gate leakage current of MIS-HEMT is about three orders of magnitude lower than that of A1GaN/CaN HEMT. Through the recessed-gate etching, the transconductanee increases effectively. When the recessed-gate depth is 1.02 nm, the best interface performance with Tit----(0.20--1.59) p^s and Dit :(0.55-1.08)x 1012 cm-2.eV- 1 can be obtained. After chlorine-based etching, the interface trap density reduces considerably without generating any new type of trap. The accumulated chlorine ions and the N vacancies in the AIGaN surface caused by the plasma etching can degrade the breakdown and the high frequency performances of devices. By comparing the characteristics of recessed-gate MIS-HEMTs with different etching times, it is found that a low power chlorine-based plasma etching for a short time (15 s in this paper) can enhance the performances of MIS-HEMTs effectively. 展开更多
关键词 A1GaN/GaN gate-recessed MIS-HEMT frequency-dependent capacitance and conduc-tance drain current injection technique knee resistance
下载PDF
RESEARCH & DESIGN OF 60 kW SOFT-SWITCHING PLASMA CONVERTER
15
作者 DU Gulping HUANG Shisheng +2 位作者 WANG Zhenmin ZENG Min CHEN Lijun 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2006年第1期28-31,共4页
A novel 60 kW plasma converter with full range soft-switch by utilizing magnetizing inductance, leakage inductance and distributed inductance is introduced. The current injection phase-shifting technique is introduced... A novel 60 kW plasma converter with full range soft-switch by utilizing magnetizing inductance, leakage inductance and distributed inductance is introduced. The current injection phase-shifting technique is introduced into the research of soft-switching plasma converter successfully. The magnetic bias of transformer and the protection of switching parts are solved. The tests state that the power supply has excellent characteristics and higher efficiency and can meet the demand of large power plasma process well. 展开更多
关键词 Soft-switching current injection technique Plasma converter
下载PDF
High-Power-Factor Adjustable Speed Drive Using Diode Clamped Multilevel Inverter
16
作者 Gunwant Ajabrao Dhomane Hiralal M Suryawanshi 《Journal of Energy and Power Engineering》 2013年第4期767-774,共8页
This paper presents a new approach to alleviate the harmonics and to enhance the power factor of the ASD (adjustable speed drive). A conventional ASD with 2-level PWM (pulse width modulation) inverters generate hi... This paper presents a new approach to alleviate the harmonics and to enhance the power factor of the ASD (adjustable speed drive). A conventional ASD with 2-level PWM (pulse width modulation) inverters generate high dv/dt and high frequency common mode voltages which are harmful for the drive applications. It reduces the motor bearings life and conducted EMI (electro magnetic interference) deteriorates the insulation. In this paper, a diode clamped multilevel (3-level) inverter is used to perform dual task. It generates HF (high frequency) current to be injected at the input of the three-phase front-end rectifier thereby improving the harmonic spectra and the power factor. It also drives the induction motor. The salient feature of this paper is that it does not require separate converters for improving power factor and to drive induction motor. Furthermore, inverter switches operate with ZVS (zero voltage switching), thus reducing the switching losses substantially, The voltage stress of the switches also has been reduced to half of the conventional 2-level converter. The inverter is operated with SPWM (sinusoidal pulse width modulation) technique. The simulation results for a prototype of 2.2 kW are presented. 展开更多
关键词 Adjustable speed drive high frequency current injection multilevel inverter zero voltage switching.
下载PDF
Optimal Scheduling of Distribution Network Incorporating Topology Reconfiguration,Battery Energy System and Load Response 被引量:1
17
作者 Xuebo Qiao Yuyao Luo +6 位作者 Juanxia Xiao Yong Li Li Jiang Xia Shao Jiazhu Xu Yi Tan Yijia Cao 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2022年第3期743-756,共14页
Distributed generation(DG)is becoming increasingly important due to the serious environmental pollution caused by conventional fossil-energy-based generation and the depletion of non-renewable energy.As the flexible r... Distributed generation(DG)is becoming increasingly important due to the serious environmental pollution caused by conventional fossil-energy-based generation and the depletion of non-renewable energy.As the flexible resources in the active distribution network(ADN),battery energy system(BES)and responsive load(RL)are all able to assist renewable DG integration in day-ahead dispatch.In addition,the security and economic level can be significantly improved by adjusting network topology.Therefore,in this paper,a coordinated day-ahead scheduling method incorporating topology reconfiguration,BES optimization and load response is presented to minimize the total day-ahead operational costs in the ADN.Linearized current injection models are presented for renewable DG,RL and BES based on the linear power flow model,and an extensible linear switching operations calculation(ELSOC)method is proposed to address the network reconfiguration.Thus,a mixed integer linear programming(MILP)model is proposed for optimal coordinated operation of an ADN.The correctness and effectiveness of the proposed method are demonstrated by simulations on a modified test system.In addition,the combined scenario and Monte-Carlo method is used to handle the uncertainties of loads and DGs,and the results of different uncertainties can further verify the feasibility of the proposed model. 展开更多
关键词 Active distribution network battery energy system linearized current injection models mixed integer linear programming network topology reconfiguration responsive load
原文传递
Large-scale OPF Based on Voltage Grading and Network Partition
18
作者 Yude Yang Zhongbiao Wu +1 位作者 Yiyi Zhang Hua Wei 《CSEE Journal of Power and Energy Systems》 SCIE 2016年第2期56-61,共6页
In this paper,a model of a large-scale optimal power flow(OPF)under voltage grading and network partition and its algorithm is presented.Based on the principles of open loop operations,the node injecting current metho... In this paper,a model of a large-scale optimal power flow(OPF)under voltage grading and network partition and its algorithm is presented.Based on the principles of open loop operations,the node injecting current method is used to divide the large-scale power grid into voltage grading and district dividing structures.The power network is further divided into a high-voltage main network and several subnets according to voltage levels of 220 kV.The subnets are connected by means of boundary nodes,and the partition model is solved using the improved approximate Newton direction method,which achieves complete dynamic decoupling simply by exchanging boundary variables between the main network and the subnets.A largescale power grid thus is decomposed into many subnets,making the solution of the problem simpler and faster while helping to protect the information of individual subnets.The system is tested for correctness and effectiveness of the proposed model,and the results obtained are matched in real-time.Finally,the algorithm is seen to have good convergence while improving calculation speed. 展开更多
关键词 Improved approximate Newton direction method large-scale power network node injecting current method optimal power flow voltage grading and network partition
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部