期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Application of DC component to select fault branch in arc suppression coil grounding system 被引量:2
1
作者 Zhi-Jie WANG Yan-Wen WANG 《Journal of Coal Science & Engineering(China)》 2013年第3期396-401,共6页
When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is... When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is much slower. This paper analyses the DC component of fault branch, and has found it is much bigger than that of the normal branches in transient state. All the simulation results obtained from three compensation types, different fault time and different wave cycles show that the DC component of fault branch is much higher than that of those normal branches. These results verify the effectiveness of taking the DC component as the method of fault line selection in the arc suppression coil grounding system. 展开更多
关键词 dc component arc suppression coil fault line selection transient state
下载PDF
DC Insulation Parameter Characteristics of XLPE in the Course of Its Aging
2
作者 WANGHong-xin CHENGShu-kang +2 位作者 WENXi-shan YAOHong-yu CHENYun-ping 《Wuhan University Journal of Natural Sciences》 EI CAS 2005年第2期421-425,共5页
This paper deals with the experimental study on the correlation betweeninsulation resistance (R) and direct current (DC) component (i_(de)) and corresponding aging degreeof insulation in the course of the aging within... This paper deals with the experimental study on the correlation betweeninsulation resistance (R) and direct current (DC) component (i_(de)) and corresponding aging degreeof insulation in the course of the aging within cross linked polyethylene (XLPE) insulation. Theaging tests were performed on a section of 10 kV transmission XLPE cable by means of water needlemethod, and _R was measured by DC voltage superimposed method, R and i_(de) were found to besignificantly dependent on the correspondingaging degree of insulation in the course of aging ofXLPE, and different kind of aging stage has different characteristics. Beside, there are generallysimilar regularity but different amplitude in the course of aging of XLPE insulation in differentelectrolyte, and the various electrochemical tree were found on the surface of aging XLPE cableimmersed in CuSO_4, solution. Therefore, according to the changing regularity of the DCcharacteristic parameters i. e. R and i_(de) within XLPE insulation judging the aging degree of XLPEinsulation will be an effective method. 展开更多
关键词 XLPE AGING insulation resistance dc component
下载PDF
Grid-Connected Control Strategy of VSG under Complex Grid Voltage Conditions
3
作者 Bin Zhang Yanjun Jin 《Energy Engineering》 EI 2022年第4期1467-1482,共16页
Under complex grid conditions,the grid voltage usually has an imbalance,low order harmonics,and a small of DC bias.When the grid voltage contains low order harmonics and a small amount of DC bias component,the inverte... Under complex grid conditions,the grid voltage usually has an imbalance,low order harmonics,and a small of DC bias.When the grid voltage contains low order harmonics and a small amount of DC bias component,the inverter’s output current cannot meet the grid connection requirements,and there is a three-phase current imbalance in the control strategy of common VSG under unbalanced voltage.A theoretical analysis of non-ideal power grids is carried out,and a VSG control strategy under complex operating conditions is proposed.Firstly,the third-order generalized integrator(TOGI)is used to eliminate the influence of the DC component of grid voltage.An improved delay signal cancellation(DSC)method is proposed to control the balance current and power fluctuation under unbalanced voltage based on the method of common VSG positive and negative sequence separation,It also eliminates the harmonic of command current.Then,the improved quasi proportional resonant controller(QPR)cascaded PI is used to suppress the harmonic current further so that the harmonic content of grid-connected current can meet the grid-connected requirements and achieve the three-phase current balance.Finally,the proposed strategy is verified by simulation under the control objectives of the current balance,active power,and reactive power constant. 展开更多
关键词 Complicated condition harmonic elimination VSG control dc component quasi-proportional resonance sequence current control
下载PDF
上一页 1 下一页 到第