The DC distribution network system equipped with a large number of power electronic equipment exhibits weak damping characteristics and is prone to low-frequency and high-frequency unstable oscillations.The current in...The DC distribution network system equipped with a large number of power electronic equipment exhibits weak damping characteristics and is prone to low-frequency and high-frequency unstable oscillations.The current interpretation of the oscillation mechanism has not been unified.Firstly,this paper established the complete statespace model of the distribution system consisting of a large number of electric vehicles,characteristic equation of the distribution network system is derived by establishing a state-space model,and simplified reduced-order equations describing the low-frequency oscillation and the high-frequency oscillation are obtained.Secondly,based on eigenvalue analysis,the oscillation modes and the influence of the key system parameters on the oscillation mode are studied.Besides,impacts of key factors,such as distribution network connection topology and number of dynamic loads,have been discussed to suppress oscillatory instability caused by inappropriate design or dynamic interactions.Finally,using the DC distribution example system,through model calculation and time-domain simulation analysis,the correctness of the aforementioned analysis is verified.展开更多
Development of the medium and low voltage DC distribution system is of great significance to a regional transmission of electric energy,increasing a penetration rate of new energy,and enhancing a safety of the operati...Development of the medium and low voltage DC distribution system is of great significance to a regional transmission of electric energy,increasing a penetration rate of new energy,and enhancing a safety of the operation of the AC/DC interconnected grid.This paper first summarizes the medium and low voltage DC distribution system schemes and plans put forward by many countries,and then elaborate status of under-construction medium and low voltage DC distribution system project cases in China.Based on these project cases,this paper analyzes key issues involved in the medium and low voltage DC distribution system topologies,equipment,operation control technologies and DC fault protections,in order to provide theoretical and technical reference for future medium and low voltage DC distribution system-related projects.Finally,this paper combines a current China research status to summarize and give a prediction about the future research direction of medium and low voltage DC distribution system,which can provide reference for the research of medium and low voltage DC distribution system.展开更多
Multi-converter approach based on the series and parallel connection topology of modular power converters has been proposed to realize higher power density DC-DC converter. The availability of the proposed approach ha...Multi-converter approach based on the series and parallel connection topology of modular power converters has been proposed to realize higher power density DC-DC converter. The availability of the proposed approach has been verified through the design consideration and the experiment. The design consideration for two DC-DC converters has been carried out by utilizing the power converter exact loss simulator, and the design parameters to maximize their power densities have been extracted taking the trade-off between the conversion efficiency and the power density into account. The prototypes of a 2,400 W, 256-384 V boost chopper using SiC-MOSFETs and a 300 W, 32-48 V GaN-FETs boost chopper have been also developed based on the design. The SiC chopper achieved the efficiency of 97.8% and the power density of 12,8 W/cm3, and the GaN chopper accomplished 98.9% and 18.6 W/cm3 in the experiment. These results show the validity of the design and the availability of the proposed approach. The multi-converter approach enables the cost reduction of the modular power converters, and contributes to realizing the widespread use of power electronics converters in the future 380 V DC distribution system.展开更多
The bipolar low-voltage DC(LVDC) distribution system has become a prospective solution to better integration of renewables and improvement of system efficiency and reliability. However, it also faces the challenge of ...The bipolar low-voltage DC(LVDC) distribution system has become a prospective solution to better integration of renewables and improvement of system efficiency and reliability. However, it also faces the challenge of power and voltage imbalance between two poles. To solve this problem, an interface converter with bipolar asymmetrical operating capabilities is applied in this paper. The steady-state models of the bipolar LVDC distribution system equipped with this interface converter in the gridconnected mode and off-grid mode are analyzed. A control scheme based on DC offset injection at the secondary side of the interface converter is proposed, enabling the bipolar LVDC distribution system to realize the unbalanced power transfer between two poles in the grid-connected mode and maintain the inherentpole voltage balance in the off-grid mode. Furthermore, this paper also proposes a primary-side DC offset injection control scheme according to the analysis of the magnetic circuit model, which can eliminate the DC bias flux caused by the secondaryside DC offset. Thereby, the potential core magnetic saturation and overcurrent issues can be prevented, ensuring the safety of the interface converter and distribution system. Detailed simulations based on the proposed control scheme are conducted to validate the function of power and voltage balance under the operation conditions of different DC loads.展开更多
The escalating deployment of distributed power sources and random loads in DC distribution networks hasamplified the potential consequences of faults if left uncontrolled. To expedite the process of achieving an optim...The escalating deployment of distributed power sources and random loads in DC distribution networks hasamplified the potential consequences of faults if left uncontrolled. To expedite the process of achieving an optimalconfiguration of measurement points, this paper presents an optimal configuration scheme for fault locationmeasurement points in DC distribution networks based on an improved particle swarm optimization algorithm.Initially, a measurement point distribution optimization model is formulated, leveraging compressive sensing.The model aims to achieve the minimum number of measurement points while attaining the best compressivesensing reconstruction effect. It incorporates constraints from the compressive sensing algorithm and networkwide viewability. Subsequently, the traditional particle swarm algorithm is enhanced by utilizing the Haltonsequence for population initialization, generating uniformly distributed individuals. This enhancement reducesindividual search blindness and overlap probability, thereby promoting population diversity. Furthermore, anadaptive t-distribution perturbation strategy is introduced during the particle update process to enhance the globalsearch capability and search speed. The established model for the optimal configuration of measurement points issolved, and the results demonstrate the efficacy and practicality of the proposed method. The optimal configurationreduces the number of measurement points, enhances localization accuracy, and improves the convergence speedof the algorithm. These findings validate the effectiveness and utility of the proposed approach.展开更多
The concept of a flexible power electronics substation(FPES)was first applied in the Zhangbei DC distribution network demonstration project.As a multi-port power electronics transformer(PET)with different AC and DC vo...The concept of a flexible power electronics substation(FPES)was first applied in the Zhangbei DC distribution network demonstration project.As a multi-port power electronics transformer(PET)with different AC and DC voltage levels,the FPES has adopted a novel topology integrating modular multilevel converter(MMC)and four-winding medium frequency transformer(FWMFT)based multiport DC-DC converter,which can significantly reduce capacitance in each sub-module(SM)of a MMC and also save space and cost.In this paper,in order to accelerate speed of electromagnetic transient(EMT)simulations of FPES based hybrid AC/DC distribution systems,an averaged-value model(AVM)is proposed for efficient and accurate representation of FPES.Assume that all SM capacitor voltages are perfectly balanced in the MMC,then the MMC behavior can be modeled using controlled voltage sources based on modulation voltages from control systems.In terms of the averaged current transfer characteristics among the windings of the FWMFT,we consider that all multiport DC-DC converters are controlled with the same dynamics,a lumped averaged model using controlled current and voltage sources has been developed for these four-port DC-DC converters connected to the upper or lower arms of the MMC.The presented FPES AVM model has been tested and validated by comparison with a detailed IGBT-based EMT model.Results show that the AVM is significantly more efficient while maintaining its accuracy in an EMT simulation.展开更多
A novel operation control method for relay protection in flexible DC distribution networks with distributed power supply is proposed to address the issue of inaccurate fault location during relay protection,leading to...A novel operation control method for relay protection in flexible DC distribution networks with distributed power supply is proposed to address the issue of inaccurate fault location during relay protection,leading to poor performance.The method combines a fault-tolerant fault location method based on long-term and short-term memory networks to accurately locate the fault section.Then,an operation control method for relay protection based on adaptive weight and whale optimization algorithm(WOA)is used to construct an objective function considering the shortest relay protection action time and the smallest impulse current.The adaptive weight and WOA are employed to obtain the optimal strategy for relay protection operation control,reducing the action time and impulse current.Experimental results demonstrate the effectiveness of the proposed method in accurately locating faults and improving relay protection performance.The longest operation time is reduced by 4.7023 s,and the maximum impulse current is limited to 0.3 A,effectively controlling the impact of large impulse currents and enhancing control efficiency.展开更多
ADC distribution network is an effective solution for increasing renewable energy utilization with distinct benefits,such as high efficiency and easy control.However,a sudden increase in the current after the occurren...ADC distribution network is an effective solution for increasing renewable energy utilization with distinct benefits,such as high efficiency and easy control.However,a sudden increase in the current after the occurrence of faults in the network may adversely affect network stability.This study proposes an artificial neural network(ANN)-based fault detection and protection method for DC distribution networks.The ANN is applied to a classifier for different faults ontheDC line.The backpropagationneuralnetwork is used to predict the line current,and the fault detection threshold is obtained on the basis of the difference between the predicted current and the actual current.The proposed method only uses local signals,with no requirement of a strict communication link.Simulation experiments are conducted for the proposed algorithm on a two-terminal DC distribution network modeled in the PSCAD/EMTDC and developed on the MATLAB platform.The results confirm that the proposed method can accurately detect and classify line faults within a few milliseconds and is not affected by fault locations,fault resistance,noise,and communication delay.展开更多
Distributed photovoltaic(PV)is one of the important power sources for building a new power system with new energy as the main body.The rapid development of distributed PV has brought new challenges to the operation of...Distributed photovoltaic(PV)is one of the important power sources for building a new power system with new energy as the main body.The rapid development of distributed PV has brought new challenges to the operation of distribution networks.In order to improve the absorption ability of large-scale distributed PV access to the distribution network,the AC/DC hybrid distribution network is constructed based on flexible interconnection technology,and a coordinated scheduling strategy model of hydrogen energy storage(HS)and distributed PV is established.Firstly,the mathematical model of distributed PV and HS system is established,and a comprehensive energy storage system combining seasonal hydrogen energy storage(SHS)and battery(BT)is proposed.Then,a flexible interconnected distribution network scheduling optimization model is established to minimize the total active power loss,voltage deviation and system operating cost.Finally,simulation analysis is carried out on the improved IEEE33 node,the NSGA-II algorithm is used to solve specific examples,and the optimal scheduling results of the comprehensive economy and power quality of the distribution network are obtained.Compared with the method that does not consider HS and flexible interconnection technology,the network loss and voltage deviation of this method are lower,and the total system cost can be reduced by 3.55%,which verifies the effectiveness of the proposed method.展开更多
This paper analyzes the load unbalance problem and voltage fluctuation problem in a 3-wire DC distribution system.It also analyzes a solution to these problems;a positive Buck-Boost voltage balancer is proposed and ex...This paper analyzes the load unbalance problem and voltage fluctuation problem in a 3-wire DC distribution system.It also analyzes a solution to these problems;a positive Buck-Boost voltage balancer is proposed and explored in order to fulfill the requirements of high quality power supply for the loads on its load side.Compared with the conventional balancer,a positive Buck-Boost converter is added to solve the voltage fluctuation problem,and the theories and methods of the voltage balancer are extended to analyze the working principle,derive the design equations,explore the stability,and calculate the efficiency.Both simulations and small power experiments are carried out to verify the validity of the working principle,the topology,and the control strategy.展开更多
GaN (gallium nitride) buck-rectifier has been proposed to realize high power density ISOP (input series and output parallel)-IPOS (input parallel and output series) converter-based dc distribution system. The ul...GaN (gallium nitride) buck-rectifier has been proposed to realize high power density ISOP (input series and output parallel)-IPOS (input parallel and output series) converter-based dc distribution system. The ultra-low loss bi-directional switch can be developed by the GaN power device because of the low on-resistance, the high-speed switching behavior and its own device structure. The buck-rectifier using the GaN bi-directional switches has the potential to achieve higher power density than the commonly utilized boost-rectifier. Availability of the GaN-HEMT (high electron mobility transistor) for the buck rectifier has been verified taking the theoretical limit of the on-resistance and the switching loss energy into account. Design consideration for a high power density buck-rectifier has been also conducted and the application effect of the GaN bidirectional switches has been evaluated quantitatively. The ISOP-IPOS converter-based dc (direct current) distribution system takes full advantage of the buck-rectifier and the rectifier using GaN devices contributes to realizing higher power density dc distribution system.展开更多
The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/D...The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/DC hybrid distribution network is put forward according to the demands of power grid, with advantages of accepting DG and DC loads, while clearing DC fault by blocking the clamping double sub-module(CDSM) of input stage. Then, this paper shows the typical structure of AC/DC distribution network that is hand in hand. Based on the new topology, this paper designs the control and modulation strategies of each stage, where the outer loop controller of input stage is emphasized for its twocontrol mode. At last, the rationality of new topology and the validity of control strategies are verified by the steady and dynamic state simulation. At the same time, the simulation results highlight the role of PET in energy regulation.展开更多
The increasing flexibility of active distribution systems(ADSs)coupled with the high penetration of renewable distributed generators(RDGs)leads to the increase of the complexity.It is of practical significance to achi...The increasing flexibility of active distribution systems(ADSs)coupled with the high penetration of renewable distributed generators(RDGs)leads to the increase of the complexity.It is of practical significance to achieve the largest amount of RDG penetration in ADSs and maintain the optimal operation.This study establishes an alternating current(AC)/direct current(DC)hybrid ADS model that considers the dynamic thermal rating,soft open point,and distribution network reconfiguration(DNR).Moreover,it transforms the optimal dispatching into a second-order cone programming problem.Considering the different control time scales of dispatchable resources,the following two-stage dispatching framework is proposed.d dispatch uses hourly input data with the goal(1)The day-ahea of minimizing the grid loss and RDG dropout.It obtains the optimal 24-hour schedule to determine the dispatching plans for DNR and the energy storage system.(2)The intraday dispatch uses 15-min input data for 1-hour rolling-plan dispatch but only executes the first 15 min of dispatching.To eliminate error between the actual operation and dispatching plan,the first 15 min is divided into three 5-min step-by-step executions.The goal of each step is to trace the tie-line power of the intraday rolling-plan dispatch to the greatest extent at the minimum cost.The measured data are used as feedback input for the rolling-plan dispatch after each step is executed.A case study shows that the comprehensive cooperative ADS model can release the line capacity,reduce losses,and improve the penetration rate of RDGs.Further,the two-stage dispatching framework can handle source-load fluctuations and enhance system stability.展开更多
Studies have indicated that the distributed compressed sensing based(DCSbased) channel estimation can decrease the length of the reference signals effectively. In block transmission, a unique word(UW) can be used as a...Studies have indicated that the distributed compressed sensing based(DCSbased) channel estimation can decrease the length of the reference signals effectively. In block transmission, a unique word(UW) can be used as a cyclic prefix and reference signal. However, the DCS-based channel estimation requires diversity sequences instead of UW. In this paper, we proposed a novel method that employs a training sequence(TS) whose duration time is slightly longer than the maximum delay spread time. Based on proposed TS, the DCS approach perform perfectly in multipath channel estimation. Meanwhile, a cyclic prefix construct could be formed, which reduces the complexity of the frequency domain equalization(FDE) directly. Simulation results demonstrate that, by using the method of simultaneous orthogonal matching pursuit(SOMP), the required channel overhead has been reduced thanks to the proposed TS.展开更多
A novel distributed model predictive control scheme based on dynamic integrated system optimization and parameter estimation (DISOPE) was proposed for nonlinear cascade systems under network environment. Under the d...A novel distributed model predictive control scheme based on dynamic integrated system optimization and parameter estimation (DISOPE) was proposed for nonlinear cascade systems under network environment. Under the distributed control structure, online optimization of the cascade system was composed of several cascaded agents that can cooperate and exchange information via network communication. By iterating on modified distributed linear optimal control problems on the basis of estimating parameters at every iteration the correct optimal control action of the nonlinear model predictive control problem of the cascade system could be obtained, assuming that the algorithm was convergent. This approach avoids solving the complex nonlinear optimization problem and significantly reduces the computational burden. The simulation results of the fossil fuel power unit are illustrated to verify the effectiveness and practicability of the proposed algorithm.展开更多
The upscaling requirements of energy transition highlight the urgent need for ramping up renewables and boosting system efficiencies.However,the stochastic nature of excessive renewable energy resources has challenged...The upscaling requirements of energy transition highlight the urgent need for ramping up renewables and boosting system efficiencies.However,the stochastic nature of excessive renewable energy resources has challenged stable and efficient operation of the power system.Battery energy storage systems(BESSs)have been identified as critical to mitigate random fluctuations,unnecessary green energy curtailment and load shedding with rapid response and flexible connection.On the other hand,an AC/DC hybrid distribution system can offer merged benefits in both AC and DC subsystems without additional losses during AC/DC power conversion.Therefore,configuring BESSs on an AC/DC distribution system is wellpositioned to meet challenges brought by carbon reductions in an efficient way.A bi-level optimization model of BESS capacity allocation for AC/DC hybrid distribution systems,considering the flexibility of voltage source converters(VSCs)and power conversion systems(PCSs),has been established in this paper to address the techno-economic issues that hindered wide implementation.The large-scale nonlinear programming problem has been solved utilizing a genetic algorithm combined with second-order cone programming.Rationality and effectiveness of the model have been verified by setting different scenarios through case studies.Simulation results have demonstrated the coordinated operation of BESS and AC/DC hybrid systems can effectively suppress voltage fluctuations and improve the cost-benefit of BESSs from a life cycle angle.展开更多
Hybrid AC/DC distribution networks are promising candidates for future applications due to their rapid advancement in power electronics technology.They use interface converters(IFCs)to link DC and AC distribution netw...Hybrid AC/DC distribution networks are promising candidates for future applications due to their rapid advancement in power electronics technology.They use interface converters(IFCs)to link DC and AC distribution networks.However,the networks possess drawbacks with AC voltage and frequency offsets when transferring from grid-tied to islanding modes.To address these problems,this paper proposes a simple but effective strategy based on the reverse droop method.Initially,the power balance equation of the distribution system is derived,which reveals that the cause of voltage and frequency offsets is the mismatch between the IFC output power and the rated load power.Then,the reverse droop control is introduced into the IFC controller.By using a voltage-active power/frequency-reactive power(U-P/f-Q)reverse droop loop,the IFC output power enables adaptive tracking of the rated load power.Therefore,the AC voltage offset and frequency offset are suppressed during the transfer process of operational modes.In addition,the universal parameter design method is discussed based on the stability limitations of the control system and the voltage quality requirements of AC critical loads.Finally,simulation and experimental results clearly validate the proposed control strategy and parameter design method.展开更多
DC technologies will be essential building blocks for future DC distribution networks.As in any DC system,these networks will face crucial threats imposed by short-circuit DC faults.Protection is thus of great interes...DC technologies will be essential building blocks for future DC distribution networks.As in any DC system,these networks will face crucial threats imposed by short-circuit DC faults.Protection is thus of great interest,and it will likely rely on DC circuit breakers(DCCBs).Among available configurations,Z-source solid-state circuit breakers(Z-SSCBs)are promising candidates for protecting low and medium-voltage distribution networks,as well as DC equipment due to their structural and control simplicity and low cost.In this paper,start-ofthe-art of Z-SSCBs topologies is reviewed.To set the context,the use of DC technologies for grid integration of renewables,DC power transmission,and the main types of DCCBs to protect DC transmission and distribution corridors are discussed.The Z-SSCB topologies are then classified into unidirectional and bidirectional.Advantages and disadvantages of different configurations are compared and analyzed based on existing research.Finally,a perspective on the future development of Z-SSCBs is discussed and potential challenges are elucidated.展开更多
Bipolar direct current(DC)distribution networks can effectively improve the connection flexibility for renewable generations and loads.In practice,concerns regarding the potential voltage unbalance issue of the distri...Bipolar direct current(DC)distribution networks can effectively improve the connection flexibility for renewable generations and loads.In practice,concerns regarding the potential voltage unbalance issue of the distribution networks and the frequency of switching still remain.This paper proposes a day-ahead polarity switching strategy to reduce voltage unbalance by optimally switching the polarity of renewable generations and loads while minimizing the switching times simultaneously in the range of a full day.First,a multi-objective optimization model is constructed to minimize the weighted sum of voltage unbalance factors and the sum of number of switching actions in the day based on the power flow model.Second,a two-step solution strategy is proposed to solve the optimization model.Finally,the proposed strategy is validated using 11-node and 34-node distribution networks as case studies,and a switching and stabilizing device is designed to enable unified switching of renewable generations and loads.Numerical results demonstrate that the proposed strategy can effectively reduce the switching times without affecting the improvement of voltage balance.展开更多
Direct current(DC)bus voltage stability is essential for the stable and reliable operation of a DC system.If an oscillation source can be quickly and accurately localized,the oscillation can be adequately eliminated.W...Direct current(DC)bus voltage stability is essential for the stable and reliable operation of a DC system.If an oscillation source can be quickly and accurately localized,the oscillation can be adequately eliminated.We propose a method based on the power spectral density for identifying the voltage oscillation source.Specifically,a DC distribution network model combined with the component connection method is developed,and the network is separated into multiple power modules.Compared with a conventional method,the proposed method does not require determining the model parameters of the entire power grid,which is typically challenging.Furthermore,combined with a novel judgment index,the oscillation source can be identified more intuitively and clearly to enhance the applicability to real power grids.The performance of the proposed method has been evaluated using the MATLAB/Simulink software and PLECS RT Box experimental platform.The simulation and experimental results verify that the proposed method can accurately identify oscillation sources in a DC distribution network.展开更多
基金supported by the State Grid Shandong Electric Power Company Economic and Technical Research Institute Project(Grant No.SGSDJY00GPJS2100135).
文摘The DC distribution network system equipped with a large number of power electronic equipment exhibits weak damping characteristics and is prone to low-frequency and high-frequency unstable oscillations.The current interpretation of the oscillation mechanism has not been unified.Firstly,this paper established the complete statespace model of the distribution system consisting of a large number of electric vehicles,characteristic equation of the distribution network system is derived by establishing a state-space model,and simplified reduced-order equations describing the low-frequency oscillation and the high-frequency oscillation are obtained.Secondly,based on eigenvalue analysis,the oscillation modes and the influence of the key system parameters on the oscillation mode are studied.Besides,impacts of key factors,such as distribution network connection topology and number of dynamic loads,have been discussed to suppress oscillatory instability caused by inappropriate design or dynamic interactions.Finally,using the DC distribution example system,through model calculation and time-domain simulation analysis,the correctness of the aforementioned analysis is verified.
基金supported by the National Key Rese arch and Development Program of China(2018YFB0904100)Science and Technology Project of State Grid(SGHB0000KXJS1800685)
文摘Development of the medium and low voltage DC distribution system is of great significance to a regional transmission of electric energy,increasing a penetration rate of new energy,and enhancing a safety of the operation of the AC/DC interconnected grid.This paper first summarizes the medium and low voltage DC distribution system schemes and plans put forward by many countries,and then elaborate status of under-construction medium and low voltage DC distribution system project cases in China.Based on these project cases,this paper analyzes key issues involved in the medium and low voltage DC distribution system topologies,equipment,operation control technologies and DC fault protections,in order to provide theoretical and technical reference for future medium and low voltage DC distribution system-related projects.Finally,this paper combines a current China research status to summarize and give a prediction about the future research direction of medium and low voltage DC distribution system,which can provide reference for the research of medium and low voltage DC distribution system.
文摘Multi-converter approach based on the series and parallel connection topology of modular power converters has been proposed to realize higher power density DC-DC converter. The availability of the proposed approach has been verified through the design consideration and the experiment. The design consideration for two DC-DC converters has been carried out by utilizing the power converter exact loss simulator, and the design parameters to maximize their power densities have been extracted taking the trade-off between the conversion efficiency and the power density into account. The prototypes of a 2,400 W, 256-384 V boost chopper using SiC-MOSFETs and a 300 W, 32-48 V GaN-FETs boost chopper have been also developed based on the design. The SiC chopper achieved the efficiency of 97.8% and the power density of 12,8 W/cm3, and the GaN chopper accomplished 98.9% and 18.6 W/cm3 in the experiment. These results show the validity of the design and the availability of the proposed approach. The multi-converter approach enables the cost reduction of the modular power converters, and contributes to realizing the widespread use of power electronics converters in the future 380 V DC distribution system.
基金supported by the National Natural Science Foundation of China (No. 51877136)the Shanghai Committee of Science and Technology (No. 19DZ1205403)the Inner Mongolia Autonomous Region Committee of Science and Technology (No. 2020GG0299)。
文摘The bipolar low-voltage DC(LVDC) distribution system has become a prospective solution to better integration of renewables and improvement of system efficiency and reliability. However, it also faces the challenge of power and voltage imbalance between two poles. To solve this problem, an interface converter with bipolar asymmetrical operating capabilities is applied in this paper. The steady-state models of the bipolar LVDC distribution system equipped with this interface converter in the gridconnected mode and off-grid mode are analyzed. A control scheme based on DC offset injection at the secondary side of the interface converter is proposed, enabling the bipolar LVDC distribution system to realize the unbalanced power transfer between two poles in the grid-connected mode and maintain the inherentpole voltage balance in the off-grid mode. Furthermore, this paper also proposes a primary-side DC offset injection control scheme according to the analysis of the magnetic circuit model, which can eliminate the DC bias flux caused by the secondaryside DC offset. Thereby, the potential core magnetic saturation and overcurrent issues can be prevented, ensuring the safety of the interface converter and distribution system. Detailed simulations based on the proposed control scheme are conducted to validate the function of power and voltage balance under the operation conditions of different DC loads.
基金the National Natural Science Foundation of China(52177074).
文摘The escalating deployment of distributed power sources and random loads in DC distribution networks hasamplified the potential consequences of faults if left uncontrolled. To expedite the process of achieving an optimalconfiguration of measurement points, this paper presents an optimal configuration scheme for fault locationmeasurement points in DC distribution networks based on an improved particle swarm optimization algorithm.Initially, a measurement point distribution optimization model is formulated, leveraging compressive sensing.The model aims to achieve the minimum number of measurement points while attaining the best compressivesensing reconstruction effect. It incorporates constraints from the compressive sensing algorithm and networkwide viewability. Subsequently, the traditional particle swarm algorithm is enhanced by utilizing the Haltonsequence for population initialization, generating uniformly distributed individuals. This enhancement reducesindividual search blindness and overlap probability, thereby promoting population diversity. Furthermore, anadaptive t-distribution perturbation strategy is introduced during the particle update process to enhance the globalsearch capability and search speed. The established model for the optimal configuration of measurement points issolved, and the results demonstrate the efficacy and practicality of the proposed method. The optimal configurationreduces the number of measurement points, enhances localization accuracy, and improves the convergence speedof the algorithm. These findings validate the effectiveness and utility of the proposed approach.
基金This work was supported in part by the National Nature Science Foundation of China(51977142)。
文摘The concept of a flexible power electronics substation(FPES)was first applied in the Zhangbei DC distribution network demonstration project.As a multi-port power electronics transformer(PET)with different AC and DC voltage levels,the FPES has adopted a novel topology integrating modular multilevel converter(MMC)and four-winding medium frequency transformer(FWMFT)based multiport DC-DC converter,which can significantly reduce capacitance in each sub-module(SM)of a MMC and also save space and cost.In this paper,in order to accelerate speed of electromagnetic transient(EMT)simulations of FPES based hybrid AC/DC distribution systems,an averaged-value model(AVM)is proposed for efficient and accurate representation of FPES.Assume that all SM capacitor voltages are perfectly balanced in the MMC,then the MMC behavior can be modeled using controlled voltage sources based on modulation voltages from control systems.In terms of the averaged current transfer characteristics among the windings of the FWMFT,we consider that all multiport DC-DC converters are controlled with the same dynamics,a lumped averaged model using controlled current and voltage sources has been developed for these four-port DC-DC converters connected to the upper or lower arms of the MMC.The presented FPES AVM model has been tested and validated by comparison with a detailed IGBT-based EMT model.Results show that the AVM is significantly more efficient while maintaining its accuracy in an EMT simulation.
文摘A novel operation control method for relay protection in flexible DC distribution networks with distributed power supply is proposed to address the issue of inaccurate fault location during relay protection,leading to poor performance.The method combines a fault-tolerant fault location method based on long-term and short-term memory networks to accurately locate the fault section.Then,an operation control method for relay protection based on adaptive weight and whale optimization algorithm(WOA)is used to construct an objective function considering the shortest relay protection action time and the smallest impulse current.The adaptive weight and WOA are employed to obtain the optimal strategy for relay protection operation control,reducing the action time and impulse current.Experimental results demonstrate the effectiveness of the proposed method in accurately locating faults and improving relay protection performance.The longest operation time is reduced by 4.7023 s,and the maximum impulse current is limited to 0.3 A,effectively controlling the impact of large impulse currents and enhancing control efficiency.
基金supported by Key Natural Science Research Projects of Colleges and Universities in Anhui Province(No.2022AH051831).
文摘ADC distribution network is an effective solution for increasing renewable energy utilization with distinct benefits,such as high efficiency and easy control.However,a sudden increase in the current after the occurrence of faults in the network may adversely affect network stability.This study proposes an artificial neural network(ANN)-based fault detection and protection method for DC distribution networks.The ANN is applied to a classifier for different faults ontheDC line.The backpropagationneuralnetwork is used to predict the line current,and the fault detection threshold is obtained on the basis of the difference between the predicted current and the actual current.The proposed method only uses local signals,with no requirement of a strict communication link.Simulation experiments are conducted for the proposed algorithm on a two-terminal DC distribution network modeled in the PSCAD/EMTDC and developed on the MATLAB platform.The results confirm that the proposed method can accurately detect and classify line faults within a few milliseconds and is not affected by fault locations,fault resistance,noise,and communication delay.
文摘Distributed photovoltaic(PV)is one of the important power sources for building a new power system with new energy as the main body.The rapid development of distributed PV has brought new challenges to the operation of distribution networks.In order to improve the absorption ability of large-scale distributed PV access to the distribution network,the AC/DC hybrid distribution network is constructed based on flexible interconnection technology,and a coordinated scheduling strategy model of hydrogen energy storage(HS)and distributed PV is established.Firstly,the mathematical model of distributed PV and HS system is established,and a comprehensive energy storage system combining seasonal hydrogen energy storage(SHS)and battery(BT)is proposed.Then,a flexible interconnected distribution network scheduling optimization model is established to minimize the total active power loss,voltage deviation and system operating cost.Finally,simulation analysis is carried out on the improved IEEE33 node,the NSGA-II algorithm is used to solve specific examples,and the optimal scheduling results of the comprehensive economy and power quality of the distribution network are obtained.Compared with the method that does not consider HS and flexible interconnection technology,the network loss and voltage deviation of this method are lower,and the total system cost can be reduced by 3.55%,which verifies the effectiveness of the proposed method.
基金supported in part by the National High Technology Research and Development of China("863 Program")(Grant No.2013AA050104)
文摘This paper analyzes the load unbalance problem and voltage fluctuation problem in a 3-wire DC distribution system.It also analyzes a solution to these problems;a positive Buck-Boost voltage balancer is proposed and explored in order to fulfill the requirements of high quality power supply for the loads on its load side.Compared with the conventional balancer,a positive Buck-Boost converter is added to solve the voltage fluctuation problem,and the theories and methods of the voltage balancer are extended to analyze the working principle,derive the design equations,explore the stability,and calculate the efficiency.Both simulations and small power experiments are carried out to verify the validity of the working principle,the topology,and the control strategy.
文摘GaN (gallium nitride) buck-rectifier has been proposed to realize high power density ISOP (input series and output parallel)-IPOS (input parallel and output series) converter-based dc distribution system. The ultra-low loss bi-directional switch can be developed by the GaN power device because of the low on-resistance, the high-speed switching behavior and its own device structure. The buck-rectifier using the GaN bi-directional switches has the potential to achieve higher power density than the commonly utilized boost-rectifier. Availability of the GaN-HEMT (high electron mobility transistor) for the buck rectifier has been verified taking the theoretical limit of the on-resistance and the switching loss energy into account. Design consideration for a high power density buck-rectifier has been also conducted and the application effect of the GaN bidirectional switches has been evaluated quantitatively. The ISOP-IPOS converter-based dc (direct current) distribution system takes full advantage of the buck-rectifier and the rectifier using GaN devices contributes to realizing higher power density dc distribution system.
基金supported by National Key Research and Development Program of China (2016YFB0900500,2017YFB0903100)the State Grid Science and Technology Project (SGRI-DL-F1-51-011)
文摘The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/DC hybrid distribution network is put forward according to the demands of power grid, with advantages of accepting DG and DC loads, while clearing DC fault by blocking the clamping double sub-module(CDSM) of input stage. Then, this paper shows the typical structure of AC/DC distribution network that is hand in hand. Based on the new topology, this paper designs the control and modulation strategies of each stage, where the outer loop controller of input stage is emphasized for its twocontrol mode. At last, the rationality of new topology and the validity of control strategies are verified by the steady and dynamic state simulation. At the same time, the simulation results highlight the role of PET in energy regulation.
基金supported by Universiti Sains Malaysia through Research University Team(RUTeam)Grant Scheme(No.1001/PELECT/8580011)。
文摘The increasing flexibility of active distribution systems(ADSs)coupled with the high penetration of renewable distributed generators(RDGs)leads to the increase of the complexity.It is of practical significance to achieve the largest amount of RDG penetration in ADSs and maintain the optimal operation.This study establishes an alternating current(AC)/direct current(DC)hybrid ADS model that considers the dynamic thermal rating,soft open point,and distribution network reconfiguration(DNR).Moreover,it transforms the optimal dispatching into a second-order cone programming problem.Considering the different control time scales of dispatchable resources,the following two-stage dispatching framework is proposed.d dispatch uses hourly input data with the goal(1)The day-ahea of minimizing the grid loss and RDG dropout.It obtains the optimal 24-hour schedule to determine the dispatching plans for DNR and the energy storage system.(2)The intraday dispatch uses 15-min input data for 1-hour rolling-plan dispatch but only executes the first 15 min of dispatching.To eliminate error between the actual operation and dispatching plan,the first 15 min is divided into three 5-min step-by-step executions.The goal of each step is to trace the tie-line power of the intraday rolling-plan dispatch to the greatest extent at the minimum cost.The measured data are used as feedback input for the rolling-plan dispatch after each step is executed.A case study shows that the comprehensive cooperative ADS model can release the line capacity,reduce losses,and improve the penetration rate of RDGs.Further,the two-stage dispatching framework can handle source-load fluctuations and enhance system stability.
基金support by National Key Technology Research and Development Program of the Ministry of Science and Technology of China (2015BAK05B01)
文摘Studies have indicated that the distributed compressed sensing based(DCSbased) channel estimation can decrease the length of the reference signals effectively. In block transmission, a unique word(UW) can be used as a cyclic prefix and reference signal. However, the DCS-based channel estimation requires diversity sequences instead of UW. In this paper, we proposed a novel method that employs a training sequence(TS) whose duration time is slightly longer than the maximum delay spread time. Based on proposed TS, the DCS approach perform perfectly in multipath channel estimation. Meanwhile, a cyclic prefix construct could be formed, which reduces the complexity of the frequency domain equalization(FDE) directly. Simulation results demonstrate that, by using the method of simultaneous orthogonal matching pursuit(SOMP), the required channel overhead has been reduced thanks to the proposed TS.
基金This work was supportedbytheNationalNaturalScienceFoundationofChina(No.60474051),theProgramforNewCenturyExcellentTalentsinUniversityofChina(NCET),andtheSpecializedResearchFundfortheDoctoralProgramofHigherEducationofChina(No.20020248028).
文摘A novel distributed model predictive control scheme based on dynamic integrated system optimization and parameter estimation (DISOPE) was proposed for nonlinear cascade systems under network environment. Under the distributed control structure, online optimization of the cascade system was composed of several cascaded agents that can cooperate and exchange information via network communication. By iterating on modified distributed linear optimal control problems on the basis of estimating parameters at every iteration the correct optimal control action of the nonlinear model predictive control problem of the cascade system could be obtained, assuming that the algorithm was convergent. This approach avoids solving the complex nonlinear optimization problem and significantly reduces the computational burden. The simulation results of the fossil fuel power unit are illustrated to verify the effectiveness and practicability of the proposed algorithm.
基金supported in part by the National Natural Science Foundation of China(No.51777134)in part by a joint project of NSFC of China and EPSRC of UK(No.52061635103 and EP/T021969/1).
文摘The upscaling requirements of energy transition highlight the urgent need for ramping up renewables and boosting system efficiencies.However,the stochastic nature of excessive renewable energy resources has challenged stable and efficient operation of the power system.Battery energy storage systems(BESSs)have been identified as critical to mitigate random fluctuations,unnecessary green energy curtailment and load shedding with rapid response and flexible connection.On the other hand,an AC/DC hybrid distribution system can offer merged benefits in both AC and DC subsystems without additional losses during AC/DC power conversion.Therefore,configuring BESSs on an AC/DC distribution system is wellpositioned to meet challenges brought by carbon reductions in an efficient way.A bi-level optimization model of BESS capacity allocation for AC/DC hybrid distribution systems,considering the flexibility of voltage source converters(VSCs)and power conversion systems(PCSs),has been established in this paper to address the techno-economic issues that hindered wide implementation.The large-scale nonlinear programming problem has been solved utilizing a genetic algorithm combined with second-order cone programming.Rationality and effectiveness of the model have been verified by setting different scenarios through case studies.Simulation results have demonstrated the coordinated operation of BESS and AC/DC hybrid systems can effectively suppress voltage fluctuations and improve the cost-benefit of BESSs from a life cycle angle.
基金This work was supported by the National Key R&D Program of China(2018YFB0904700).
文摘Hybrid AC/DC distribution networks are promising candidates for future applications due to their rapid advancement in power electronics technology.They use interface converters(IFCs)to link DC and AC distribution networks.However,the networks possess drawbacks with AC voltage and frequency offsets when transferring from grid-tied to islanding modes.To address these problems,this paper proposes a simple but effective strategy based on the reverse droop method.Initially,the power balance equation of the distribution system is derived,which reveals that the cause of voltage and frequency offsets is the mismatch between the IFC output power and the rated load power.Then,the reverse droop control is introduced into the IFC controller.By using a voltage-active power/frequency-reactive power(U-P/f-Q)reverse droop loop,the IFC output power enables adaptive tracking of the rated load power.Therefore,the AC voltage offset and frequency offset are suppressed during the transfer process of operational modes.In addition,the universal parameter design method is discussed based on the stability limitations of the control system and the voltage quality requirements of AC critical loads.Finally,simulation and experimental results clearly validate the proposed control strategy and parameter design method.
基金This work was supported in part by FLEXIS.FLEXIS is part-funded by the European Regional Development Fund(ERDF),through the Welsh Government(WEFO case number 80836)The work was also supported in part by the UK EPSRC Sustainable urban power supply through intelligent control and enhanced restoration of AC/DC networks,under Grant EP/T021985/1in part by the National Nature Science Foundation of China(Grant No.52272403)。
文摘DC technologies will be essential building blocks for future DC distribution networks.As in any DC system,these networks will face crucial threats imposed by short-circuit DC faults.Protection is thus of great interest,and it will likely rely on DC circuit breakers(DCCBs).Among available configurations,Z-source solid-state circuit breakers(Z-SSCBs)are promising candidates for protecting low and medium-voltage distribution networks,as well as DC equipment due to their structural and control simplicity and low cost.In this paper,start-ofthe-art of Z-SSCBs topologies is reviewed.To set the context,the use of DC technologies for grid integration of renewables,DC power transmission,and the main types of DCCBs to protect DC transmission and distribution corridors are discussed.The Z-SSCB topologies are then classified into unidirectional and bidirectional.Advantages and disadvantages of different configurations are compared and analyzed based on existing research.Finally,a perspective on the future development of Z-SSCBs is discussed and potential challenges are elucidated.
基金supported by Fundamental Research Funds for the Central Universities(No.2022CDJXY-007)。
文摘Bipolar direct current(DC)distribution networks can effectively improve the connection flexibility for renewable generations and loads.In practice,concerns regarding the potential voltage unbalance issue of the distribution networks and the frequency of switching still remain.This paper proposes a day-ahead polarity switching strategy to reduce voltage unbalance by optimally switching the polarity of renewable generations and loads while minimizing the switching times simultaneously in the range of a full day.First,a multi-objective optimization model is constructed to minimize the weighted sum of voltage unbalance factors and the sum of number of switching actions in the day based on the power flow model.Second,a two-step solution strategy is proposed to solve the optimization model.Finally,the proposed strategy is validated using 11-node and 34-node distribution networks as case studies,and a switching and stabilizing device is designed to enable unified switching of renewable generations and loads.Numerical results demonstrate that the proposed strategy can effectively reduce the switching times without affecting the improvement of voltage balance.
基金supported in part by the National Natural Science Foundation of China(No.51807112)。
文摘Direct current(DC)bus voltage stability is essential for the stable and reliable operation of a DC system.If an oscillation source can be quickly and accurately localized,the oscillation can be adequately eliminated.We propose a method based on the power spectral density for identifying the voltage oscillation source.Specifically,a DC distribution network model combined with the component connection method is developed,and the network is separated into multiple power modules.Compared with a conventional method,the proposed method does not require determining the model parameters of the entire power grid,which is typically challenging.Furthermore,combined with a novel judgment index,the oscillation source can be identified more intuitively and clearly to enhance the applicability to real power grids.The performance of the proposed method has been evaluated using the MATLAB/Simulink software and PLECS RT Box experimental platform.The simulation and experimental results verify that the proposed method can accurately identify oscillation sources in a DC distribution network.