Research on DC Fault of Multi-Terminal Direct Current System
1
作者 S. Y. Fan J. Liu +2 位作者 E. M. Bian H. T. Xu C. L. Kang 《Energy and Power Engineering》 2017年第4期756-764,共9页
This paper introduces the characteristics of VSC and MMC-MTDC and discusses the effects of different kinds of faults in HVDC systems. Special attention is given to the comparison between a pole-to-pole fault and a pol... This paper introduces the characteristics of VSC and MMC-MTDC and discusses the effects of different kinds of faults in HVDC systems. Special attention is given to the comparison between a pole-to-pole fault and a pole-to-ground fault occurring in the middle of the line or at the terminal of a VSC. Simulations using MATLAB are provided in this article which show the difference effects clearly when faults occur in a VSC-MTDC system or in a MMC-MTDC system. Understanding of such fault characteristics and the influence of the control system on them are important prerequisites on the way to MTDC systems. 展开更多
关键词 VSC-MTdc MMC-MTdc dc fault
下载PDF
Research on Parameter Collaborative Configuration of DC Circuit Breaker and DC Fault Current Limiter
2
作者 Lu Qu Zhanqing Yu Zhichang Yuan 《Journal of Power and Energy Engineering》 2019年第9期80-93,共14页
Fault current suppression is the key technology to ensure the safe operation of the DC power distribution system. In order to realize the parameter collabora-tive configuration of the DC circuit breaker and the DC cur... Fault current suppression is the key technology to ensure the safe operation of the DC power distribution system. In order to realize the parameter collabora-tive configuration of the DC circuit breaker and the DC current limiter and improve the fault current suppression capability, the fault current suppression mechanism of the DC power distribution system is revealed based on the circuit model. Then, based on the mathematical model of the DC breaker, the characteristic parameters of DC breaking are extracted, and then the influence of different characteristic parameters on the breaking characteristics of fault current is studied. Finally, the mathematical model of the collaborative process between DC circuit breaker and DC current limiter is established. The charac-teristic parameters of fault current collaborative suppression are extracted. The coupling effects of different characteristic parameters on the fault current col-laborative suppression are studied. The principle of collaborative configuration of DC circuit breaker and DC current limiter is proposed, and the collaborative suppression ability of DC circuit breaker and DC current limiter to fault current is fully exploited to ensure the safe and reliable operation of the DC power distribution system. 展开更多
关键词 dc Power Distribution System fault CURRENT dc Circuit BREAKER dc CURRENT LIMITER
下载PDF
基于电磁时间反演的VSC-HVDC系统架空线-电缆混合线路故障定位方法
3
作者 张艳霞 李婷 《电力自动化设备》 EI CSCD 北大核心 2024年第3期180-186,224,共8页
针对传统故障定位方法无法应用于架空线-电缆混合直流线路的问题,提出了一种架空线-电缆混合直流线路的故障定位方法,该方法采用先确定故障点所在区段、后在区段中定位的原理。利用故障附加网络的直流分量定义了故障区段判别函数,通过... 针对传统故障定位方法无法应用于架空线-电缆混合直流线路的问题,提出了一种架空线-电缆混合直流线路的故障定位方法,该方法采用先确定故障点所在区段、后在区段中定位的原理。利用故障附加网络的直流分量定义了故障区段判别函数,通过该判别函数在不同区段发生故障时数值不同实现故障区段的判定。然后,分析了电磁时间反演理论在故障定位中的可行性,分析确定了故障特征谐波。利用线路两端特征谐波的电流行进波作为时间反演电路的电流源,设置与原线路拓扑结构镜像的线路,利用时间反演电流源与镜像线路构建时间反演电路。在此基础上,根据时间反演的能量聚焦特性列写故障区段内的故障定位方程并实现区段内故障定位。利用PSCAD/EMTDC搭建的电压源型换流器高压直流输电(VSC-HVDC)系统仿真证明了所提方法能实现线缆混合直流输电线路的故障定位。 展开更多
关键词 架空线-电缆混合直流线路 故障定位 故障区段判别函数 时间反演 能量聚焦
下载PDF
Modeling of High-frequency Electromagnetic Oscillation for DC Fault in MMC-HVDC Systems
4
作者 Hong Shen Zhonghao Dongye +4 位作者 Lei Qi Muxue Wang Xiangyu Zhang Peng Qiu Xiaoguang Wei 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第3期1151-1160,共10页
DC short-circuit faults pose a hazard to the operation of a modular multilevel converter(MMC)-based high voltage direct current(HVDC)system,necessitating reliable fault clearing solutions with rapid reaction.However,b... DC short-circuit faults pose a hazard to the operation of a modular multilevel converter(MMC)-based high voltage direct current(HVDC)system,necessitating reliable fault clearing solutions with rapid reaction.However,because the parasitic capacitances of the main equipment oscillate with the lumped inductances of the HVDC system,strong electromagnetic oscillations with multiple frequencies occur during clearance transients.These oscillations will disturb the HVDC system’s protection and control systems.Therefore,this paper focuses on the modeling of these oscillations.First,an equivalent circuit for the MMC-based HVDC system is proposed,taking into account the parasitic capacitances of the system’s major components,such as DC reactors,connecting cables,and DC circuit breakers(DCCBs).Second,four distinct oscillation stages are postulated based on action coordination of MMCs and DCCBs,and the associated analytical equations for the oscillation frequencies are derived.Third,a 200 kV MMC-based DC converter station is subjected to an 6ms/6kA pole-to-pole(PTP)short-circuit test.Electromagnetic oscillations have a frequency range of several kHz to several hundreds of kHz.The measured waveforms correspond well with simulated results,including the parasitic characteristics.Additionally,the relative errors between the simulated and measured frequencies are less than 5%. 展开更多
关键词 dc short-circuit fault electromagnetic oscillation MMC-HVdc parasitic parameter wide-band model
原文传递
DC fault analysis for modular multilevel converter-based system 被引量:30
5
作者 Bin LI Jiawei HE +2 位作者 Jie TIAN Yadong FENG Yunlong DONG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第2期275-282,共8页
DC fault protection is the key technique for the development of the DC distribution and transmission system. This paper analyzes the transient characteristics of DC faults in a modular multilevel converter(MMC) based ... DC fault protection is the key technique for the development of the DC distribution and transmission system. This paper analyzes the transient characteristics of DC faults in a modular multilevel converter(MMC) based DC system combining with the numerical method. Meanwhile,lots of simulation tests based on MATLAB/Simulink are carried out to verify the correctness of the theoretical analysis. Finally, the technological difficulties of and requirements for the protection and isolation are discussed to provide the theoretical foundation for the design of dc fault protection strategy. 展开更多
关键词 dc system dc fault analysis dc fault protection Modular multilevel converter
原文传递
适用于MMC-MTDC的母线侧故障分析及保护策略
6
作者 鄢仁武 俞智鹏 方略斌 《高电压技术》 EI CAS CSCD 北大核心 2024年第5期2067-2077,I0019-I0022,共15页
柔性直流输电系统中,直流故障的分析与判别是柔直系统中亟待解决的重要问题。为了更好地分析故障特征,推导出一种多端柔性直流输电网(modular multilevel converter-high voltage direct current,MMC-MTDC)的母线侧简化电路故障计算方法... 柔性直流输电系统中,直流故障的分析与判别是柔直系统中亟待解决的重要问题。为了更好地分析故障特征,推导出一种多端柔性直流输电网(modular multilevel converter-high voltage direct current,MMC-MTDC)的母线侧简化电路故障计算方法,并分析了母线侧单极接地故障和极间短路故障的故障特征,在此基础上设计了一种适用于多端柔性直流输电网的故障判别方案和保护措施。该判别方案通过故障启动判据、故障区域判别和故障类型判别3个模块进行故障判定,采用了故障电压瞬时跌落值与系统电压之差及故障线路电流值作故障特征量,整套判别方案不受其他元件参数、故障位置等因素的影响,将Spearman相关性分析与传统电气故障区域判别相结合,准确判定系统区内外故障的同时,解决了故障区域判别中受线路各参数干扰导致误判的问题,仿真测试验证了本保护方案的可行性。 展开更多
关键词 MMC-HVdc 直流故障 母线侧故障 故障特征 Spearman相关性分析 保护设计
下载PDF
含主动限流控制的MMC-HVDC电网直流短路故障电流解析计算
7
作者 吴丽丽 茆美琴 施永 《电工技术学报》 EI CSCD 北大核心 2024年第3期785-797,共13页
传统的MMC-HVDC电网直流短路故障电流计算一般采用等效RLC电路方法。但是该方法没有考虑主动限流控制(ACLC)对等效电路RLC参数的影响,因此无法直接用于含ACLC的MMC-HVDC电网的直流短路故障电流的解析计算问题。该文通过将ACLC的控制效... 传统的MMC-HVDC电网直流短路故障电流计算一般采用等效RLC电路方法。但是该方法没有考虑主动限流控制(ACLC)对等效电路RLC参数的影响,因此无法直接用于含ACLC的MMC-HVDC电网的直流短路故障电流的解析计算问题。该文通过将ACLC的控制效果等效为虚拟阻抗产生的压降,建立了体现ACLC的控制影响的等效RLC电路,以包含电流变化率限流环节的典型ACLC算法为例,推导了直流双极短路故障条件下ACLC的控制参数与虚拟阻抗的映射关系以及相应的直流故障电流解析表达式。最后,以基于含ACLC的半桥型四端MMC-HVDC电网为例,建立PSCAD/EMTDC仿真模型,对采用ACLC的直流双极短路故障电流解析计算结果进行了验证。结果表明:故障后10ms内直流短路故障电流的PSCAD仿真结果与所提出的含ACLC的等效RLC电路解析计算结果的平均误差在8.29%以内,最大误差在10.99%。因此,使用所提出的方法具有工程实用性。 展开更多
关键词 模块化多电平换流器 主动限流控制 虚拟阻抗 RLC电路 直流短路故障电流计算
下载PDF
基于MMC主动限流的VSC-HVDC双极短路故障控保协同策略
8
作者 刘思奇 胡鹏飞 +1 位作者 王栋 江道灼 《电力系统自动化》 EI CSCD 北大核心 2024年第10期192-202,共11页
直流故障保护是柔性直流输电系统发展面临的主要挑战之一,利用模块化多电平换流器(MMC)的灵活控制实现限流已成为当前研究的热点。MMC的主动限流降低了故障电流变化率和故障电流幅值,易引起故障判断以及保护选择困难。文中以对称单极接... 直流故障保护是柔性直流输电系统发展面临的主要挑战之一,利用模块化多电平换流器(MMC)的灵活控制实现限流已成为当前研究的热点。MMC的主动限流降低了故障电流变化率和故障电流幅值,易引起故障判断以及保护选择困难。文中以对称单极接线的柔性直流系统为研究对象,采用控保协同思想,将主动限流控制与故障识别相结合,提出了基于主动限流因子的故障区域识别与区分方法实现双极短路故障的区域识别与切除。首先,通过在MMC电流内环控制器中附加故障电流目标预设控制器,在故障发生后可快速跟踪故障电流的变化,自适应地调整MMC输出的直流电压将故障电流控制在预设目标参考值附近;其次,根据不同故障位置时故障电流目标预设控制器输出的限流因子快速确定故障区域。最后,在PSCAD/EMTDC中对四端柔性直流输电系统的不同故障场景进行了仿真分析,验证了所提控保协同策略的可行性和有效性。 展开更多
关键词 柔性直流输电 模块化多电平换流器 故障电流限制 控保协同 短路故障
下载PDF
基于IAO-ELM的DC-DC电路软故障诊断
9
作者 黄郑 《电子质量》 2024年第2期32-39,共8页
针对DC-DC电路软故障诊断精确度差的问题,提出了一种基于改进的天鹰算法(IAO)-优化极限学习机(ELM)的故障诊断方法。采用变分模态分解的方法对原始的故障信号进行分解重构,提取时频域特征作为特征向量。使用SPM混沌映射、透镜反向学习... 针对DC-DC电路软故障诊断精确度差的问题,提出了一种基于改进的天鹰算法(IAO)-优化极限学习机(ELM)的故障诊断方法。采用变分模态分解的方法对原始的故障信号进行分解重构,提取时频域特征作为特征向量。使用SPM混沌映射、透镜反向学习、自适应权重和柯西变异策略改进天鹰算法,提升其寻优性能。采用IAO对ELM的输入权值和隐含层偏置进行优化,得到IAO-ELM诊断模型,提高分类精度。结果显示,IAO-ELM诊断模型的准确率为99.375%,能有效地实现DC-DC电路软故障诊断。 展开更多
关键词 dc-dc电路 故障诊断 天鹰算法 极限学习机 变分模态分解
下载PDF
基于CRS-LMD和SVD的MMC-HVDC线路故障测距方法
10
作者 贺宇阳 马千里 +1 位作者 于飞 刘喜梅 《电力系统保护与控制》 EI CSCD 北大核心 2024年第1期121-132,共12页
直流输电线路故障行波波速不确定、波头提取困难以及噪声干扰等因素制约了直流电网中故障测距技术的应用。为了降低上述因素对定位准确性的影响,提出一种基于局部特征有理样条插值均值分解(LMD based on characteristic rational spline... 直流输电线路故障行波波速不确定、波头提取困难以及噪声干扰等因素制约了直流电网中故障测距技术的应用。为了降低上述因素对定位准确性的影响,提出一种基于局部特征有理样条插值均值分解(LMD based on characteristic rational spline,CRS-LMD)和奇异值分解(singular value decomposition,SVD)的故障测距方法。首先,利用特征尺度选取最优极点系数,结合有理样条插值调节拟合曲线的松紧程度,实现对故障电压行波的局部均值分解。其次,采用奇异值分解对故障行波波头进行准确提取。最后,在PSCAD/EMTDC中搭建了张北±500 kV柔性直流电网的仿真模型,模拟各种故障情况并输出故障数据,利用Matlab对故障数据进行处理并验证定位算法。最后,仿真结果表明,所提故障测距算法在不同故障距离和故障类型下均能实现故障测距,且在叠加噪声和过渡电阻的情况下也能保障较高的精确性。 展开更多
关键词 串柔性直流电网 有理样条插值 局部均值分解 奇异值分解 行波提取 故障测距
下载PDF
Hybrid MMC with Low Voltage Operations and DC Fault Ride-through Capabilities Based on Auxiliary Full-bridge Converter 被引量:3
11
作者 Xibei Zhao Jiangping Ding +1 位作者 Jianzhong Xu Jinsha Yuan 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2022年第3期864-871,共8页
The hybrid modular multilevel converter(MMC)based on half-bridge sub-modules(HBSMs)and full-bridge submodules(FBSMs)can operate at low DC voltages and clear DC side fault currents.However,the costs and power losses ar... The hybrid modular multilevel converter(MMC)based on half-bridge sub-modules(HBSMs)and full-bridge submodules(FBSMs)can operate at low DC voltages and clear DC side fault currents.However,the costs and power losses are much higher in hybrid converters.An auxiliary full-bridge converter(AFC)is designed to reconstruct the converter structure in the arm level,and the HBSMs output capacitor voltage through the AFC can attain similar capabilities to hybrid MMCs.The operational principle of the auxiliary full-bridge converter is discussed,and the low voltage operation and non-blocking fault ride through control are verified in a two-terminal DC network simulation.Through economic analysis,the power loss of the AFC is similar to a HBSM MMC but the total investment is lower than a hybrid MMC,making the AFC a promising solution to improve the existing HBSM converter with more controllability. 展开更多
关键词 dc fault fault ride through hybrid MMC low voltage operation
原文传递
A comprehensive review of DC fault protection methods in HVDC transmission systems 被引量:7
12
作者 Mohan Muniappan 《Protection and Control of Modern Power Systems》 2021年第1期1-20,共20页
High voltage direct current (HVDC) transmission is an economical option for transmitting a large amount of power over long distances. Initially, HVDC was developed using thyristor-based current source converters (CSC)... High voltage direct current (HVDC) transmission is an economical option for transmitting a large amount of power over long distances. Initially, HVDC was developed using thyristor-based current source converters (CSC). With the development of semiconductor devices, a voltage source converter (VSC)-based HVDC system was introduced, and has been widely applied to integrate large-scale renewables and network interconnection. However, the VSC-based HVDC system is vulnerable to DC faults and its protection becomes ever more important with the fast growth in number of installations. In this paper, detailed characteristics of DC faults in the VSC-HVDC system are presented. The DC fault current has a large peak and steady values within a few milliseconds and thus high-speed fault detection and isolation methods are required in an HVDC grid. Therefore, development of the protection scheme for a multi-terminal VSC-based HVDC system is challenging. Various methods have been developed and this paper presents a comprehensive review of the different techniques for DC fault detection, location and isolation in both CSC and VSC-based HVDC transmission systems in two-terminal and multi-terminal network configurations. 展开更多
关键词 HVdc VSC Multi-terminal dc grid dc fault fault detection and location fault isolation
原文传递
Neutral-point-clamped hybrid multilevel converter with DC fault blocking capability for medium-voltage DC transmission 被引量:3
13
作者 Xinyu YU Yingdong WEI +3 位作者 Qirong JIANG Xiaorong XIE Yuquan LIU Ke WANG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第4期524-536,共13页
This paper proposes a novel hybrid multilevel converter with DC fault-blocking capability, i.e., the neutral-point clamped hybrid multilevel converter(NHMC).By employing two types of unipolar full-bridge submodules al... This paper proposes a novel hybrid multilevel converter with DC fault-blocking capability, i.e., the neutral-point clamped hybrid multilevel converter(NHMC).By employing two types of unipolar full-bridge submodules along with director switches, which are composed of seriesconnected insulated-gate bipolar transistors, the NHMC combines the features and advantages of the neutral-point clamped converter and the modular multilevel converter.The basic topology, operating principles, modulation scheme, and energy-balancing scheme of the NHMC are presented. The DC fault-blocking capability of the NHMC is investigated. The number of power electronic devices used by the NHMC is calculated and compared with other multilevel converters, showing that the proposed NHMC can be an economical and feasible option for medium-voltage DC transmission with overhead lines. Simulation results demonstrate the features and operating scheme of the proposed NHMC. 展开更多
关键词 Neutral-point-clamped hybrid multilevel converter(NHMC) Unipolar full-bridge submodule(UFBSM) dc fault blocking capability Modulation scheme
原文传递
Coordination Method for DC Fault Current Suppression and Clearance in DC Grids 被引量:2
14
作者 Xibei Zhao Lixu Chen +2 位作者 Gen Li Jianzhong Xu Jinsha Yuan 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2022年第5期1438-1447,共10页
The modular multilevel converter(MMC)based DC grid is considered as a future solution for bulk renewable energy integration and transmission.However,the high probability of DC faults and their rapid propagation speed ... The modular multilevel converter(MMC)based DC grid is considered as a future solution for bulk renewable energy integration and transmission.However,the high probability of DC faults and their rapid propagation speed are the main challenges in the development of DC grids.Existing research primarily focuses on the DC fault clearance methods,while the fault current suppression methods are still barely researched.Additionally,the coordination method of fault current suppression and clearance needs to be optimized.In this paper,the technical characteristics of the current suppression methods are studied,and the coordinated methods of fault current suppression and clearance are proposed.At last,a cost comparison of these methods is presented.The research results show that the proposed strategies can reduce the cost of the protection equipment. 展开更多
关键词 dc circuit breaker dc fault dc grid fault current limiter(FCL)
原文传递
Novel Modular Multilevel Converter Against DC Faults for HVDC Applications 被引量:2
15
作者 Xiaofeng Yang Yao Xue +3 位作者 Bowei Chen Zhiqin Lin Trillion Q.Zheng Yan Li 《CSEE Journal of Power and Energy Systems》 SCIE 2017年第2期140-149,共10页
In view of the DC fault current isolation deficiency for the conventional half-bridge sub-module(HBSM)based modular multilevel converter(MMC),this paper presents an improved MMC topology.Both quasi reverse blocking su... In view of the DC fault current isolation deficiency for the conventional half-bridge sub-module(HBSM)based modular multilevel converter(MMC),this paper presents an improved MMC topology.Both quasi reverse blocking submodules(QRBSMs)and current limit modules(CLMs)are employed to improve the DC fault handling capability for HVDC applications.This paper analyzes such a new converter configuration and operation principles.Then the DC pole-to-pole short circuit fault is taken into consideration for further study,as well as the fault current blocking mechanism and quantitative relationship between system electrical stress and key parameters.To validate the feasibility of the proposed topology and fault protection theory,extensive simulation results are demonstrated.It is concluded that the QRB-MMC can effectively block the fault current under DC fault condition.In addition,CLMs play an important role in further accelerating fault current attenuation.Moreover,QRB-MMC employs the original control and modulation strategies under normal operation conditions;thus,it further reduces the complexity of industry design. 展开更多
关键词 Current limit module dc faults HVdc transmission modular multilevel converter quasi reverse blocking sub-module
原文传递
A Three-phase Integrated Power Electronic Transformer with the Capability of DC Fault Clearance 被引量:1
16
作者 Yunfei Xu Guangfu Tang +2 位作者 Weiguo Li Guoliang Zhao Zhanfeng Deng 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第4期785-796,共12页
This paper presents a three-phase integrated power electronic transformer(PET)topology with the capability of DC fault clearance based on the investigation of PET topology.The proposed PET has three ports of high-volt... This paper presents a three-phase integrated power electronic transformer(PET)topology with the capability of DC fault clearance based on the investigation of PET topology.The proposed PET has three ports of high-voltage AC,high-voltage DC and low-voltage DC,which can achieve the flexible access of distributed energy resources・The power unit of the PET adopts a three-phase integrated topology,and the single-phase fluctuating power in the DC-link capacitor is reduced by a 4-port DC/DC converter,thereby reducing the capacitance of the DC-link capacitor;Meanwhile,the power unit uses the clamp double sub-module(CDSM)to allow for self-clearing of the short-circuit fault on the high-voltage DC side.Finally,this paper verifies the proposed PET through an EMT simulation and experimental prototype. 展开更多
关键词 dc fault clearing experimental verification power electronic transformer three phase integration
原文传递
Simulation Research of Fault Model of Detecting Rotor Dynamic Eccentricity in Brushless DC Motor Based on Motor Current Signature Analysis 被引量:12
17
作者 赵向阳 葛文韬 《中国电机工程学报》 EI CSCD 北大核心 2011年第36期I0011-I0011,共1页
基于Ansoft/Maxwell设置动态偏心故障,建立求解电机电感和磁链的有限元模型,通过仿真,证明了将感应电机动态偏心故障的特征频率经过简化后,同样适用于无刷直流电动机。基于Ansoft/Simplorer建立无刷直流电动机系统的仿真模型。在... 基于Ansoft/Maxwell设置动态偏心故障,建立求解电机电感和磁链的有限元模型,通过仿真,证明了将感应电机动态偏心故障的特征频率经过简化后,同样适用于无刷直流电动机。基于Ansoft/Simplorer建立无刷直流电动机系统的仿真模型。在电机稳态运行下,对定子电流进行傅里叶分析,研究并建立基于定子电流监测动态偏心故障的仿真模型:动态偏心故障与特征频率的关系、动态偏心故障程度与特征频率幅值的关系。进而研究了无刷直流电动机稳态运行时转速波动对偏心故障监测的影响。仿真结果表明,转子偏心程度加大,特征频率的幅值增加。 展开更多
关键词 电机转子 故障检测 电流特征 偏心 直流 仿真 模型 机械故障
下载PDF
DC faults ride-through capability analysis of Full-Bridge MMC-MTDC System 被引量:38
18
作者 ZHAO ChengYong XU JianZhong LI Tan 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第1期253-261,共9页
Full-Bridge Modular Multilevel Converter(FBMMC) has strong ability to ride through serious DC faults,thus it is very suitable for multi-terminal flexible HVDC applications.However,no references have reported the locat... Full-Bridge Modular Multilevel Converter(FBMMC) has strong ability to ride through serious DC faults,thus it is very suitable for multi-terminal flexible HVDC applications.However,no references have reported the locating and isolating of DC faults and corresponding DC faults ride-through capability evaluation index.This paper introduces the topology mechanism of FBMMC and its loss reduction operation mode,theoretically certifies that the universal decoupled control strategy of Voltage Source Converter(VSC) and the similar modulation strategies of Half-Bridge MMC(HBMMC) can be applied to FBMMC for constructing complete closed-loop control system.On the basis of the existing DC faults locating and isolating schemes of 2-level VSC based Multi-Terminal HVDC(VSC-MTDC) system and the particularity of FBMMC,this paper proposes the DC faults wire selection "handshaking" method of the FBMMC-MTDC system,and proposes the DC Fault Ride-Through Capability Index(DFRTI) for evaluating the DC faults suppressing capability of the VSC-MTDC systems,including FBMMC-MTDC.Simulations of FBMMC-MTDC in PSCAD/EMTDC validate the correctness and effectiveness of the proposed control strategy and evaluation index. 展开更多
关键词 直流故障 C系统 全桥 力分析 EMTdc 解耦控制策略 直流输电系统 多电平变流器
原文传递
Fault Analysis of DC Voltage Dividers in Xiangjiaba--Shanghai ±800 kV UHVDC Project 被引量:8
19
作者 LI Fengqi SHE Zhengqiu +2 位作者 LOU Dianqiang Rajendra Iyer Urban Astrom 《高电压技术》 EI CAS CSCD 北大核心 2012年第12期3244-3248,共5页
关键词 直流分压器 故障分析 特高压直流输电 向家坝 上海 直流输电工程 直流电压 测量误差
下载PDF
Study on the Detection Methods of DC Series Arc Fault 被引量:3
20
作者 JI Shengchang LIU Yuan ZHU Yeye ZHU Lingyu 《高电压技术》 EI CAS CSCD 北大核心 2013年第9期2131-2137,共7页
It is difficult to detect and extinguish direct current(DC)arc in power electronics systems,and the arc could easily lead to a fire and cause great damage to surrounding equipment.A DC arc generation simulation unit i... It is difficult to detect and extinguish direct current(DC)arc in power electronics systems,and the arc could easily lead to a fire and cause great damage to surrounding equipment.A DC arc generation simulation unit is established,in which DC series arcs are generated by dragging the moving electrode away from the fixed one with the help of the stepper motor.In addition,a ferrite rod antenna is used to receive the electromagnetic radiation signals induced by the arcs.Based on experiments using the unit,the general characteristics of DC arc,including the pulse characteristics of arc current and source output in corresponding time window,and the frequency-domain characteristics of arc current,are studied.With discussion on three detection methods,it is concluded that the variation of current and voltage of arc,the spectrum of the arc current during the discontinuous intervals and the radiating electromagnetic signal are all features that can be adopted for detecting DC series arc.Therefore,a synthetic judgment method is suggested for further study. 展开更多