BXERL is a proposal for a test facility (Beijing X-ray Energy Recovery Linac), which requires its injector to provide an electron beam of 5 MeV, 77 pC/ bunch at a repetition rate of 130 MHz (average current of 10 m...BXERL is a proposal for a test facility (Beijing X-ray Energy Recovery Linac), which requires its injector to provide an electron beam of 5 MeV, 77 pC/ bunch at a repetition rate of 130 MHz (average current of 10 mA). In this paper, we present the design of the injector, which consists of a 500 kV photocathode DC gun equipped with a GaAs cathode preparation device, a 1.3 GHz normal conducting RF buncher, two solenoids, and one cryomodule containing two 1.3 GHz 2-cell superconducting RF cavities as the energy booster. The detailed beam dynamics show that the injector can generate electron bunches with a RMS normalized emittance of 1.49 πmm.mrad, a bunch length of 0.67 mm, a beam energy of 5 MeV and an energy spread of 0.72%.展开更多
In this study,an X-band standing-wave biperiodic linear accelerator was developed for medical radiotherapy that can accel-erate electrons to 9 MeV using a 2.4-MW klystron.The structure works atπ/2 mode and adopts mag...In this study,an X-band standing-wave biperiodic linear accelerator was developed for medical radiotherapy that can accel-erate electrons to 9 MeV using a 2.4-MW klystron.The structure works atπ/2 mode and adopts magnetic coupling between cavities,generating the appropriate adjacent mode separation of 10 MHz.The accelerator is less than 600-mm long and constitutes four bunching cells and 29 normal cells.Geometry optimizations,full-scale radiofrequency(RF)simulations,and beam dynamics calculations were performed.The accelerator was fabricated and examined using a low-power RF test.The cold test results showed a good agreement with the simulation and actual measurement results.In the high-power RF test,the output beam current,energy spectrum,capture ratio,and spot size at the accelerator exit were measured.With the input power of 2.4 MW,the pulse current was 100 mA,and the output spot root-mean-square radius was approximately 0.5 mm.The output kinetic energy was 9.04 MeV with the spectral FWHM of 3.5%,demonstrating the good performance of this accelerator.展开更多
In this paper, we the design study of a L-band DC photocathode gun injector for the ERL (Energy Recovery Linac) test facility. The main parameters of the injector are energy of 2.3 MeV, a bunch length of 2 ps, and a...In this paper, we the design study of a L-band DC photocathode gun injector for the ERL (Energy Recovery Linac) test facility. The main parameters of the injector are energy of 2.3 MeV, a bunch length of 2 ps, and a normalized emittance of 2.1 mm.mrad.展开更多
基金Supported by Creative Research Foundation of Institute of High Energy Physics (H85453G0U2)Key Project of Chinese National Programs for Fundamental Research and Development (2008CB817700)
文摘BXERL is a proposal for a test facility (Beijing X-ray Energy Recovery Linac), which requires its injector to provide an electron beam of 5 MeV, 77 pC/ bunch at a repetition rate of 130 MHz (average current of 10 mA). In this paper, we present the design of the injector, which consists of a 500 kV photocathode DC gun equipped with a GaAs cathode preparation device, a 1.3 GHz normal conducting RF buncher, two solenoids, and one cryomodule containing two 1.3 GHz 2-cell superconducting RF cavities as the energy booster. The detailed beam dynamics show that the injector can generate electron bunches with a RMS normalized emittance of 1.49 πmm.mrad, a bunch length of 0.67 mm, a beam energy of 5 MeV and an energy spread of 0.72%.
基金the Key R&D Project of the Ministry of Science and Technology of China(No.2022YFC2402300).
文摘In this study,an X-band standing-wave biperiodic linear accelerator was developed for medical radiotherapy that can accel-erate electrons to 9 MeV using a 2.4-MW klystron.The structure works atπ/2 mode and adopts magnetic coupling between cavities,generating the appropriate adjacent mode separation of 10 MHz.The accelerator is less than 600-mm long and constitutes four bunching cells and 29 normal cells.Geometry optimizations,full-scale radiofrequency(RF)simulations,and beam dynamics calculations were performed.The accelerator was fabricated and examined using a low-power RF test.The cold test results showed a good agreement with the simulation and actual measurement results.In the high-power RF test,the output beam current,energy spectrum,capture ratio,and spot size at the accelerator exit were measured.With the input power of 2.4 MW,the pulse current was 100 mA,and the output spot root-mean-square radius was approximately 0.5 mm.The output kinetic energy was 9.04 MeV with the spectral FWHM of 3.5%,demonstrating the good performance of this accelerator.
文摘In this paper, we the design study of a L-band DC photocathode gun injector for the ERL (Energy Recovery Linac) test facility. The main parameters of the injector are energy of 2.3 MeV, a bunch length of 2 ps, and a normalized emittance of 2.1 mm.mrad.