AIM:To evaluate the technical feasibility of a modified tapered metal tip and low profile introducer for onestep endoscopic ultrasound(EUS)-guided biliary drainage(EUS-BD)in a new experimental biliary dilatation porci...AIM:To evaluate the technical feasibility of a modified tapered metal tip and low profile introducer for onestep endoscopic ultrasound(EUS)-guided biliary drainage(EUS-BD)in a new experimental biliary dilatation porcine model.METHODS:A novel dedicated device for one-step EUS-guided biliary drainage system(DEUS)introducer has size 3F tapered catheter with size 4F metal tip for simple puncture of the intestinal wall and liver parenchyma without graded dilation.A self-expandable metal stent,consisting of both uncovered and nitinol-covered portions,was preloaded into DEUS introducer.After establishment of a biliary dilatation model using endoscopic hemoclips or band ligation with argon plasma coagulation in 9 mini-pigs,EUS-BD using a DEUS was performed following 19-G needle puncture without the use of fistula dilation devices.RESULTS:One-step EUS-BD was technically successful in seven pigs[7/9(77.8%)as intention to treat]without the aid of devices for fistula dilation from the high body of stomach or far distal esophagus to the intrahepatic(n=2)or common hepatic(n=5)duct.Primary technical failure occurred in two cases that did not show adequate biliary dilatation.In seven pigs with a successful bile duct dilatation,the technical success rate was 100%(7/7 as per protocol).Median procedure time from confirmation of the dilated bile duct to successful placement of a metallic stent was 10 min(IQR;8.9-18.1).There were no immediate procedure-related complications.CONCLUSION:Modified tapered metal tip and low profile introducer may be technically feasible for onestep EUS-BD in experimental porcine model.展开更多
In this paper, study objects are raw and dilative tussah silk. By means of measuring and analyzing the fiber's diameter, linear density, diameter coefficient, thickness and fullness, this paper focuses on the infl...In this paper, study objects are raw and dilative tussah silk. By means of measuring and analyzing the fiber's diameter, linear density, diameter coefficient, thickness and fullness, this paper focuses on the influence of dilative technology on tussah silk's fiber and fabric. The results include the following three aspects: the diameter coefficient of dilative tussah silk fiber is increased by 10.35%, dilative tussah heather silk is thicker and fabric fullness is improved by 9%.展开更多
基金Supported by the Soonchunhyang University Research Fund,a research grant(2013-7202)from the Asan Institute for Life Sciences,Asan Medical Centerthe National Center of Efficacy Evaluation for the Development of Health Products Targeting Digestive Disorders
文摘AIM:To evaluate the technical feasibility of a modified tapered metal tip and low profile introducer for onestep endoscopic ultrasound(EUS)-guided biliary drainage(EUS-BD)in a new experimental biliary dilatation porcine model.METHODS:A novel dedicated device for one-step EUS-guided biliary drainage system(DEUS)introducer has size 3F tapered catheter with size 4F metal tip for simple puncture of the intestinal wall and liver parenchyma without graded dilation.A self-expandable metal stent,consisting of both uncovered and nitinol-covered portions,was preloaded into DEUS introducer.After establishment of a biliary dilatation model using endoscopic hemoclips or band ligation with argon plasma coagulation in 9 mini-pigs,EUS-BD using a DEUS was performed following 19-G needle puncture without the use of fistula dilation devices.RESULTS:One-step EUS-BD was technically successful in seven pigs[7/9(77.8%)as intention to treat]without the aid of devices for fistula dilation from the high body of stomach or far distal esophagus to the intrahepatic(n=2)or common hepatic(n=5)duct.Primary technical failure occurred in two cases that did not show adequate biliary dilatation.In seven pigs with a successful bile duct dilatation,the technical success rate was 100%(7/7 as per protocol).Median procedure time from confirmation of the dilated bile duct to successful placement of a metallic stent was 10 min(IQR;8.9-18.1).There were no immediate procedure-related complications.CONCLUSION:Modified tapered metal tip and low profile introducer may be technically feasible for onestep EUS-BD in experimental porcine model.
文摘In this paper, study objects are raw and dilative tussah silk. By means of measuring and analyzing the fiber's diameter, linear density, diameter coefficient, thickness and fullness, this paper focuses on the influence of dilative technology on tussah silk's fiber and fabric. The results include the following three aspects: the diameter coefficient of dilative tussah silk fiber is increased by 10.35%, dilative tussah heather silk is thicker and fabric fullness is improved by 9%.