Removable partial dentures (RPDs) (conventional and implant-supported) treatment is considered a viable option to replace missing teeth as inexpensively as possible, but it has limitations. Objectives: This study repo...Removable partial dentures (RPDs) (conventional and implant-supported) treatment is considered a viable option to replace missing teeth as inexpensively as possible, but it has limitations. Objectives: This study reports the effect of gender and location (maxilla vs. mandible) on the clinical performance of removable partial dentures (RPDs). Materials and Methods: A total of 100 Patients who had RPDs delivered between 1990-1995 were evaluated. A 4-point scoring system was used to assess seventeen criteria. These criteria include acceptance, stability, support, retention, adaptation, occlusion, integrity, and design of the pros-theses, rest and rest seat preparation, occlusal wear, esthetics, phonetics, tissue condition, mobility of abutments, gingival and plaque indices. The data were analyzed using Kruskal-Wallis and Mann-Whitney U non-parametric statistical tests. Results: The results showed that acceptance of RPDs was rated the lowest. Other reasons for failure were poor retention, lack of integrity of the prostheses and inadequate adaptation. Retention and design of major connectors attributed to Mandibular RPD failure. Success rate of 75% was observed in male compared with 67.2% for female. Maxillary RPDs showed a higher success rate (78%) compared with the mandibular (70.1%). No significant statistical difference in Alpha scores between female and male patients and between maxillary and mandibular RPDs (p < 0.05). Conclusions: The clinical performance of RPDs showed a higher success rate in male patients compared to female patients and the maxillary RPDs showed a higher success rate compared to mandibular.展开更多
The aim of this study was to evaluate whether partial removable denture use indeed leads to improved oral health related quality of life and masticatory function. Materials and Methods: Partially edentulous patients p...The aim of this study was to evaluate whether partial removable denture use indeed leads to improved oral health related quality of life and masticatory function. Materials and Methods: Partially edentulous patients presenting for removable denture treatment at the Prosthodontics Service in the Hospital Affiliated to Kinshasa University (Democratic Republic of Congo) were assessed for enrolment in this study. After applying exclusion criteria, 378 patients were included in the study, and randomly assigned into 2 groups. Oral health related quality of life (OHIP-23) and mastication time (MaT), number of chewing cycles (MaC), mastication frequency (MaF), and the sizes of the peanut fragments (FraS) were compared in both groups. Statistical significance was set at p < 0.05. Results: The average MaC, MaT, MaF, and FraS were 119 (± SD 53.70), 86.75 (±SD 35.35), 1.38 (±SD 0.25), and 3.3 (±SD 3.25) for the denture group and 77.9 (±SD 23.9), 60.2 (±SD 17.91), 1.29 (±SD 0.15), and 1.5 (±SD 0.7) for the non-denture group, respectively. Conclusion: The overall oral health related quality of life was best in the non-denture than denture.展开更多
Objective: The goal of the removable partial denture is to restore impaired esthetics and masticatory function by replacing missing teeth. The aim of this study was to establish a possible correla-tion between removab...Objective: The goal of the removable partial denture is to restore impaired esthetics and masticatory function by replacing missing teeth. The aim of this study was to establish a possible correla-tion between removable partial denture in acrylic resin use after 5 years and dental diseases. Materials and Methods: Partially edentulous patients presenting for removable denture treatment at the Prosthodontics service of the Affiliated Hospital of Kinshasa University, Democratic Republic of Congo were assessed in this study. Patients were randomly assigned into 2 groups: Denture and non-denture group. Caries and periodontal diseases were compared between both groups. Statistical significance was set at p < 0.05. Results: The average age in the denture and non-denture-group was 53.15 (±SD 22.05) and 31.59 (±SD 11.98) years. Out of 160 teeth were decayed, both 110 teeth (68.75%) in the denture-group and 50 teeth (31.25%) in the non-denture group. The DMFT index calculated at start time of the study was 0.2 for both groups, after five years was 7.1 for the denture-group and 2.6 for the non-denture-group. The plaque index in the denture-group had an index of 1 and that of non-denture-group was 0.5. Conclusion: The relationship has been found between patients’ wearers a RPD and dental diseases.展开更多
A computer-aided design model for a fixed partial denture was constructed and used in a finite element analysis to study the overall load sharing mechanism between the fixed partial denture and oral structures while t...A computer-aided design model for a fixed partial denture was constructed and used in a finite element analysis to study the overall load sharing mechanism between the fixed partial denture and oral structures while the denture base rested on the al- veolar ridge. To investigate the consequences of non-contact conditions, three additional models were generated incorporating a uniform clearance of 0.125 mm, 0.25 mm, and 0.5 mm, respectively. A 100 N static load located at the free end of the prosthesis was applied while the distal portion of the jaw was set fixed. The results show that whilst releasing the ridge almost entirely, the presence of the clearance drastically increased the load on the splinting teeth. A pull-out force on the canine tooth of about 44 N was computed, accompanied by a mesio-distal moment of about 500 N.cm. The combination of which was similar to the tooth extraction maneuver performed by the dentist. In contrast, the second premolar was found to bear a push-in force of almost 115 N. The first molar, though barely solicited in the contact condition, became substantially loaded in non-contact conditions, which validates the choice of sacrificing three teeth to support the denture.展开更多
Interface debonding between prostheses and abutments was the most frequent failure mode of resin-bonded fixed partials dentures(RBFPDs) in clinic. The purpose of this study was to investigate the effect of accessory r...Interface debonding between prostheses and abutments was the most frequent failure mode of resin-bonded fixed partials dentures(RBFPDs) in clinic. The purpose of this study was to investigate the effect of accessory retention forms on the bond strength of RBFPDs. Three types of 3D finite element models were constructed.The model of posterior metal plate RBFPD with spoon-shaped occlusal rest seats served as the control. The remaining two types of models based on the control added the retention form design of the pin hole and axial groove respectively. The axial or buccolingual load of 150 N was applied on the prosthesis, first premolar and first molar respectively. The maximum principal stresses of the adhesive layer in different models were calculated. Under the load of the same magnitude, the stress due to the buccolingual load was significantly higher than that due to the axial load in the adhesive layer. The proximal shoulder, occlusal rest seats wall and the proximal margin adjacent to the shoulder were the high risk region where the adhesive layer damaged easily. Compared with the control model, the pin and groove models could slightly decrease the stress in the adhesive layer after the axial loading, while the stress in the adhesive layer drastically decreased after horizontal loading and reduced by 22% and 31% respectively. These results indicate that the horizontal occlusal force has a more serious harm to the debonding of RBFPDs. In addition, the accessory retention forms(e.g. pin and axial groove retention forms) can decrease the stress level in the adhesive layer, which are conducive to increase the load-bearing capacity of RBFPDs.展开更多
Survey lines are important features on the dental meshes for removable partial denture frameworks design, but few researche has been done by surveying digital models. This article describes a method for identifying su...Survey lines are important features on the dental meshes for removable partial denture frameworks design, but few researche has been done by surveying digital models. This article describes a method for identifying survey line on dental meshes and displays survey line in real time. At the beginning, we segment tooth based on morphologic operators to get the tooth parts. The second step is to calculate the viewing direction perpendicular to the occlusal plane. Finally, we extract boundary points on 2D plane, thereby obtaining a survey line in the surveying direction. We have developed a module to demonstrate survey line in real time.展开更多
Objective:This study investigated the effect of proximal contact strength on the three-dimensional displacements of cantilever fixed partial denture(CFPD) under vertically concentrated loading with digital laser speck...Objective:This study investigated the effect of proximal contact strength on the three-dimensional displacements of cantilever fixed partial denture(CFPD) under vertically concentrated loading with digital laser speckle(DLS) technique.Methods:Fresh mandible of beagle dog was used to establish the implant-supported CFPD for specimen.DLS technique was employed for measuring the three-dimensional displacement of the prosthesis under vertically concentrated loading ranging from 200 to 3 000 g.The effect of the contact tightness on the displacement of CFPD was investigated by means of changing the contact tightness.Results:When an axial concentrated loading was exerted on the pontic of the implant-supported CFPD,the displacement of the CFPD was the greatest.The displacement of the prosthesis decreased with the increase of contact strength.When the contact strength was 0,0.95,and 3.25 N,the displacement of the buccolingual direction was smaller than that of the mesiodistal direction but greater than that of the occlusogingival direction.When the force on the contact area was 6.50 N,the mesiodistal displacement of the prosthesis was the biggest while the buccolingual displacement was the smallest.Conclusions:The implant supported CFPD is an effective therapy for fully or partially edentulous patients.The restoration of the contact area and the selection of the appropriate contact strength can reduce the displacement of the CFPD,and get a better stress distribution.The most appropriate force value is 3.25 N in this study.展开更多
文摘Removable partial dentures (RPDs) (conventional and implant-supported) treatment is considered a viable option to replace missing teeth as inexpensively as possible, but it has limitations. Objectives: This study reports the effect of gender and location (maxilla vs. mandible) on the clinical performance of removable partial dentures (RPDs). Materials and Methods: A total of 100 Patients who had RPDs delivered between 1990-1995 were evaluated. A 4-point scoring system was used to assess seventeen criteria. These criteria include acceptance, stability, support, retention, adaptation, occlusion, integrity, and design of the pros-theses, rest and rest seat preparation, occlusal wear, esthetics, phonetics, tissue condition, mobility of abutments, gingival and plaque indices. The data were analyzed using Kruskal-Wallis and Mann-Whitney U non-parametric statistical tests. Results: The results showed that acceptance of RPDs was rated the lowest. Other reasons for failure were poor retention, lack of integrity of the prostheses and inadequate adaptation. Retention and design of major connectors attributed to Mandibular RPD failure. Success rate of 75% was observed in male compared with 67.2% for female. Maxillary RPDs showed a higher success rate (78%) compared with the mandibular (70.1%). No significant statistical difference in Alpha scores between female and male patients and between maxillary and mandibular RPDs (p < 0.05). Conclusions: The clinical performance of RPDs showed a higher success rate in male patients compared to female patients and the maxillary RPDs showed a higher success rate compared to mandibular.
文摘The aim of this study was to evaluate whether partial removable denture use indeed leads to improved oral health related quality of life and masticatory function. Materials and Methods: Partially edentulous patients presenting for removable denture treatment at the Prosthodontics Service in the Hospital Affiliated to Kinshasa University (Democratic Republic of Congo) were assessed for enrolment in this study. After applying exclusion criteria, 378 patients were included in the study, and randomly assigned into 2 groups. Oral health related quality of life (OHIP-23) and mastication time (MaT), number of chewing cycles (MaC), mastication frequency (MaF), and the sizes of the peanut fragments (FraS) were compared in both groups. Statistical significance was set at p < 0.05. Results: The average MaC, MaT, MaF, and FraS were 119 (± SD 53.70), 86.75 (±SD 35.35), 1.38 (±SD 0.25), and 3.3 (±SD 3.25) for the denture group and 77.9 (±SD 23.9), 60.2 (±SD 17.91), 1.29 (±SD 0.15), and 1.5 (±SD 0.7) for the non-denture group, respectively. Conclusion: The overall oral health related quality of life was best in the non-denture than denture.
文摘Objective: The goal of the removable partial denture is to restore impaired esthetics and masticatory function by replacing missing teeth. The aim of this study was to establish a possible correla-tion between removable partial denture in acrylic resin use after 5 years and dental diseases. Materials and Methods: Partially edentulous patients presenting for removable denture treatment at the Prosthodontics service of the Affiliated Hospital of Kinshasa University, Democratic Republic of Congo were assessed in this study. Patients were randomly assigned into 2 groups: Denture and non-denture group. Caries and periodontal diseases were compared between both groups. Statistical significance was set at p < 0.05. Results: The average age in the denture and non-denture-group was 53.15 (±SD 22.05) and 31.59 (±SD 11.98) years. Out of 160 teeth were decayed, both 110 teeth (68.75%) in the denture-group and 50 teeth (31.25%) in the non-denture group. The DMFT index calculated at start time of the study was 0.2 for both groups, after five years was 7.1 for the denture-group and 2.6 for the non-denture-group. The plaque index in the denture-group had an index of 1 and that of non-denture-group was 0.5. Conclusion: The relationship has been found between patients’ wearers a RPD and dental diseases.
文摘A computer-aided design model for a fixed partial denture was constructed and used in a finite element analysis to study the overall load sharing mechanism between the fixed partial denture and oral structures while the denture base rested on the al- veolar ridge. To investigate the consequences of non-contact conditions, three additional models were generated incorporating a uniform clearance of 0.125 mm, 0.25 mm, and 0.5 mm, respectively. A 100 N static load located at the free end of the prosthesis was applied while the distal portion of the jaw was set fixed. The results show that whilst releasing the ridge almost entirely, the presence of the clearance drastically increased the load on the splinting teeth. A pull-out force on the canine tooth of about 44 N was computed, accompanied by a mesio-distal moment of about 500 N.cm. The combination of which was similar to the tooth extraction maneuver performed by the dentist. In contrast, the second premolar was found to bear a push-in force of almost 115 N. The first molar, though barely solicited in the contact condition, became substantially loaded in non-contact conditions, which validates the choice of sacrificing three teeth to support the denture.
基金National Natural Science Foundation of Chinagrant number:10902010,11120101001,and 10925208
文摘Interface debonding between prostheses and abutments was the most frequent failure mode of resin-bonded fixed partials dentures(RBFPDs) in clinic. The purpose of this study was to investigate the effect of accessory retention forms on the bond strength of RBFPDs. Three types of 3D finite element models were constructed.The model of posterior metal plate RBFPD with spoon-shaped occlusal rest seats served as the control. The remaining two types of models based on the control added the retention form design of the pin hole and axial groove respectively. The axial or buccolingual load of 150 N was applied on the prosthesis, first premolar and first molar respectively. The maximum principal stresses of the adhesive layer in different models were calculated. Under the load of the same magnitude, the stress due to the buccolingual load was significantly higher than that due to the axial load in the adhesive layer. The proximal shoulder, occlusal rest seats wall and the proximal margin adjacent to the shoulder were the high risk region where the adhesive layer damaged easily. Compared with the control model, the pin and groove models could slightly decrease the stress in the adhesive layer after the axial loading, while the stress in the adhesive layer drastically decreased after horizontal loading and reduced by 22% and 31% respectively. These results indicate that the horizontal occlusal force has a more serious harm to the debonding of RBFPDs. In addition, the accessory retention forms(e.g. pin and axial groove retention forms) can decrease the stress level in the adhesive layer, which are conducive to increase the load-bearing capacity of RBFPDs.
文摘Survey lines are important features on the dental meshes for removable partial denture frameworks design, but few researche has been done by surveying digital models. This article describes a method for identifying survey line on dental meshes and displays survey line in real time. At the beginning, we segment tooth based on morphologic operators to get the tooth parts. The second step is to calculate the viewing direction perpendicular to the occlusal plane. Finally, we extract boundary points on 2D plane, thereby obtaining a survey line in the surveying direction. We have developed a module to demonstrate survey line in real time.
文摘Objective:This study investigated the effect of proximal contact strength on the three-dimensional displacements of cantilever fixed partial denture(CFPD) under vertically concentrated loading with digital laser speckle(DLS) technique.Methods:Fresh mandible of beagle dog was used to establish the implant-supported CFPD for specimen.DLS technique was employed for measuring the three-dimensional displacement of the prosthesis under vertically concentrated loading ranging from 200 to 3 000 g.The effect of the contact tightness on the displacement of CFPD was investigated by means of changing the contact tightness.Results:When an axial concentrated loading was exerted on the pontic of the implant-supported CFPD,the displacement of the CFPD was the greatest.The displacement of the prosthesis decreased with the increase of contact strength.When the contact strength was 0,0.95,and 3.25 N,the displacement of the buccolingual direction was smaller than that of the mesiodistal direction but greater than that of the occlusogingival direction.When the force on the contact area was 6.50 N,the mesiodistal displacement of the prosthesis was the biggest while the buccolingual displacement was the smallest.Conclusions:The implant supported CFPD is an effective therapy for fully or partially edentulous patients.The restoration of the contact area and the selection of the appropriate contact strength can reduce the displacement of the CFPD,and get a better stress distribution.The most appropriate force value is 3.25 N in this study.