In this study, we fabricated a Cerenkov fiber-optic dosimeter (CFOD) without any scintillator to measure Cerenkov radiation signals owing to gamma-rays. The relative depth dose (RDD) distributions of Ir-192 HDR brachy...In this study, we fabricated a Cerenkov fiber-optic dosimeter (CFOD) without any scintillator to measure Cerenkov radiation signals owing to gamma-rays. The relative depth dose (RDD) distributions of Ir-192 HDR brachytherapy source were obtained by using the CFOD based on a subtraction method and the RDD curve was compared with the simulation result of Monte Carlo N-particle extended transport code (MCNPX). Finally, we demonstrated that the CFOD can be used to measure real-time dose information for HDR brachytherapy.展开更多
Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date. This study is an investigating of percentage depth dose enhancement wi...Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date. This study is an investigating of percentage depth dose enhancement within the gel medium with the use of conformal distribution gold nanoparticle as contrast agents by high atomic number material. In this work, the normoxic polymer gel dosimeter MAGICA tissue-equivalence was first theoretically verified using MCNPX Monte Carlo code and experimentally by percentage depth dose curves within the gel medium. Then gold nanoparticles (GNPs) of 50 nm diameter with different concentrations of 0.1 mM, 0.2 mM, and 0.4 mM were embedded in MAGICA gel and irradiated by 18 MV photon beam. Experimental results have shown dose increase of 10%, 2% and 4% in 0.1 mM, 0.2 mM and 0.4 mM concentrations, respectively. Simulation results had good agreement in the optimum concentration of 0.1 mM. The largest error between experimental and simulation results was equal to 9.28% stood for 0.4 mM concentration. The results showed that the optimum concentration of gold nanoparticles to achieve maximum absorbed dose in both experimental and simulation was 0.1 mM and so it can be used for clinical studies.展开更多
A formula describing the percentage depth dose curve for <sup>60</sup>Co γ beams is theoretically developed. The formula only needs a few data determined by measuring directly in water phantom and can be ...A formula describing the percentage depth dose curve for <sup>60</sup>Co γ beams is theoretically developed. The formula only needs a few data determined by measuring directly in water phantom and can be used to calculate the whole set of percentage depth dose (PDD) and tissuse air ratios (TAR) for the wide range of SSD (from 20cm to 100cm), field size (from 4cm×4cm to 20cm×20cm) and depth (from d<sub>m</sub> to 30cm). The data calculated by the formula fits very well to the data currently used in clinics with the maximum error less than 1% and probable error of about 0.1%-0.3%. Using this formula can overcome the time-exhausting work in measurement of PDD and TAR.展开更多
BACKGROUND Helicobacter pylori(H.pylori)eradication rates have fallen globally,likely in large part due to increasing antibiotic resistance to traditional therapy.In areas of high clarithromycin and metronidazole resi...BACKGROUND Helicobacter pylori(H.pylori)eradication rates have fallen globally,likely in large part due to increasing antibiotic resistance to traditional therapy.In areas of high clarithromycin and metronidazole resistance such as ours,Maastricht VI guidelines suggest high dose amoxicillin dual therapy(HDADT)can be considered,subject to evidence for local efficacy.In this study we assess efficacy of HDADT therapy for H.pylori eradication in an Irish cohort.AIM To assess the efficacy of HDADT therapy for H.pylori eradication in an Irish cohort as both first line,and subsequent therapy for patients diagnosed with H.pylori.METHODS All patients testing positive for H.pylori in a tertiary centre were treated prospectively with HDADT(amoxicillin 1 g tid and esomeprazole 40 mg bid×14 d)over a period of 8 months.Eradication was confirmed with Urea Breath Test at least 4 wk after cessation of therapy.A delta-over-baseline>4%was considered positive.Patient demographics and treatment outcomes were recorded,analysed and controlled for basic demographics and prior H.pylori treatment.RESULTS One hundred and ninety-eight patients were identified with H.pylori infection,10 patients were excluded due to penicillin allergy and 38 patients refused follow up testing.In all 139 were included in the analysis,55%(n=76)were female,mean age was 46.6 years.Overall,93(67%)of patients were treatment-naïve and 46(33%)had received at least one previous course of treatment.The groups were statistically similar.Self-reported compliance with HDADT was 97%,mild side-effects occurred in 7%.There were no serious adverse drug reactions.Overall the eradication rate for our cohort was 56%(78/139).Eradication rates were worse for those with previous treatment[43%(20/46)vs 62%(58/93),P=0.0458,odds ratio=2.15].Age and Gender had no effect on eradication status.CONCLUSION Overall eradication rates with HDADT were disappointing.Despite being a simple and possibly better tolerated regime,these results do not support its routine use in a high dual resistance country.Further investigation of other regimens to achieve the>90%eradication target is needed.展开更多
The increasing popularity of the metaverse has led to a growing interest and market size in spatial computing from both academia and industry.Developing portable and accurate imaging and depth sensing systems is cruci...The increasing popularity of the metaverse has led to a growing interest and market size in spatial computing from both academia and industry.Developing portable and accurate imaging and depth sensing systems is crucial for advancing next-generation virtual reality devices.This work demonstrates an intelligent,lightweight,and compact edge-enhanced depth perception system that utilizes a binocular meta-lens for spatial computing.The miniaturized system comprises a binocular meta-lens,a 532 nm filter,and a CMOS sensor.For disparity computation,we propose a stereo-matching neural network with a novel H-Module.The H-Module incorporates an attention mechanism into the Siamese network.The symmetric architecture,with cross-pixel interaction and cross-view interaction,enables a more comprehensive analysis of contextual information in stereo images.Based on spatial intensity discontinuity,the edge enhancement eliminates illposed regions in the image where ambiguous depth predictions may occur due to a lack of texture.With the assistance of deep learning,our edge-enhanced system provides prompt responses in less than 0.15 seconds.This edge-enhanced depth perception meta-lens imaging system will significantly contribute to accurate 3D scene modeling,machine vision,autonomous driving,and robotics development.展开更多
Ultrahigh-dose-rate radiotherapy(FLASH-RT)is a revolutionary radiotherapy technology that can spare normal tissues without compromising tumor control.Although qualitative experimental results have been reported,quanti...Ultrahigh-dose-rate radiotherapy(FLASH-RT)is a revolutionary radiotherapy technology that can spare normal tissues without compromising tumor control.Although qualitative experimental results have been reported,quantitative and systematic analysis of data is necessary.Particularly,the FLASH effect response model to the dose or dose rate is still unclear.This study investigated the relationships between the FLASH effect and experimental parameters,such as dose,dose rate,and other factors by analyzing published in vivo experimental data from animal models.The data were modeled based on logistic regression analysis using the sigmoid function.The model was evaluated using prediction accuracy,receiver operating characteristic(ROC)curve,and area under the ROC curve.Results showed that the FLASH effect was closely related to the dose,mean dose rate,tissue type,and corresponding biological endpoints.The dose rate corresponding to a 50% probability of triggering cognitive protection in the brain was 45 Gy s^(-1).The dose rate corresponding to a 50% probability of triggering intestinal crypt survival and regeneration was 140 Gy s^(-1).For the skin toxicity effect,the dose corresponding to a 50% probability of triggering the FLASH effect was 24 Gy.This study helps to characterize the conditions underlying the FLASH effect and provides important information for optimizing experiments.展开更多
One of the major innovations awaiting in electron microscopy is full three-dimensional imaging at atomic resolution.Despite the success of aberration correction to deep sub-angstrom lateral resolution,spatial resoluti...One of the major innovations awaiting in electron microscopy is full three-dimensional imaging at atomic resolution.Despite the success of aberration correction to deep sub-angstrom lateral resolution,spatial resolution in depth is still far from atomic resolution.In scanning transmission electron microscopy(STEM),this poor depth resolution is due to the limitation of the illumination angle.To overcome this physical limitation,it is essential to implement a next-generation aberration corrector in STEM that can significantly improve the depth resolution.This review discusses the capability of depth sectioning for three-dimensional imaging combined with large-angle illumination STEM.Furthermore,the statistical analysis approach remarkably improves the depth resolution,making it possible to achieve three-dimensional atomic resolution imaging at oxide surfaces.We will also discuss the future prospects of three-dimensional imaging at atomic resolution by STEM depth sectioning.展开更多
The dependence of groundwater quality on borehole depth is usually debatable in groundwater studies, especially in complex geological formations where aquifer characteristics vary spatially with depth. This study ther...The dependence of groundwater quality on borehole depth is usually debatable in groundwater studies, especially in complex geological formations where aquifer characteristics vary spatially with depth. This study therefore seeks to investigate the relationship between borehole depth and groundwater quality across the granitoid aquifers within the Birimian Supergroup in the Ashanti Region. Physicochemical analysis records of groundwater quality data were collected from 23 boreholes of public and private institutions in the Ashanti Region of Ghana, and the parametric values of iron, fluoride, total hardness, pH, nitrate, and nitrite were used to study the groundwater quality-depth relationship. The results showed that the depth-to-groundwater quality indicated a marginal increase in water quality in the range of 30 to 50 m, which is mathematically represented by the low-value correlation coefficient (r<sup>2</sup> = 0.026). A relatively significant increase occurs in the depth range of 50 to 80 m, which is given by a correlation coefficient of r<sup>2</sup> = 0.298. The mean percent parameter compatibility was 74%, 82%, 89%, and 97% at 50, 60, 70, and 80 m depths, respectively. The variations in groundwater quality per depth ratio ranged from 1.48, 1.37, 1.27, and 1.21 for 50, 60, 70, and 80 m depth, respectively. The recommended minimum borehole depth for excellent groundwater quality is suggested with a compatibility per meter depth ratio of 1.37. This results in a range between 50 and 70 m as the most desirable drilling depth for excellent groundwater quality within the granitoids of the Birimian Supergroup of the Ashanti Region in Ghana.展开更多
Depth estimation is an important task in computer vision.Collecting data at scale for monocular depth estimation is challenging,as this task requires simultaneously capturing RGB images and depth information.Therefore...Depth estimation is an important task in computer vision.Collecting data at scale for monocular depth estimation is challenging,as this task requires simultaneously capturing RGB images and depth information.Therefore,data augmentation is crucial for this task.Existing data augmentationmethods often employ pixel-wise transformations,whichmay inadvertently disrupt edge features.In this paper,we propose a data augmentationmethod formonocular depth estimation,which we refer to as the Perpendicular-Cutdepth method.This method involves cutting realworld depth maps along perpendicular directions and pasting them onto input images,thereby diversifying the data without compromising edge features.To validate the effectiveness of the algorithm,we compared it with existing convolutional neural network(CNN)against the current mainstream data augmentation algorithms.Additionally,to verify the algorithm’s applicability to Transformer networks,we designed an encoder-decoder network structure based on Transformer to assess the generalization of our proposed algorithm.Experimental results demonstrate that,in the field of monocular depth estimation,our proposed method,Perpendicular-Cutdepth,outperforms traditional data augmentationmethods.On the indoor dataset NYU,our method increases accuracy from0.900 to 0.907 and reduces the error rate from0.357 to 0.351.On the outdoor dataset KITTI,our method improves accuracy from 0.9638 to 0.9642 and decreases the error rate from 0.060 to 0.0598.展开更多
Background: World Health Organization recommends the implementation of contact tracing and Leprosy Post Exposure prophylaxis (LPEP) to interrupt the chain of transmission. To accelerate the uptake of this recommendati...Background: World Health Organization recommends the implementation of contact tracing and Leprosy Post Exposure prophylaxis (LPEP) to interrupt the chain of transmission. To accelerate the uptake of this recommendation, a cross-sectional study among contacts of leprosy patients was conducted to investigate the feasibility of integrating leprosy systematic contact tracing and post-exposure prophylaxis (PEP) into the routine leprosy control program. Methods: This was a mixed methods cross-sectional study. The study was implemented in Kumi, Ngora, Serere, Soroti, Budaka and Kibuku Districts. Results: The 45 enrolled index patients (97.8% of the registered) identified a total of 135 contacts, of which 134 (99·2%) consented and were screened. Among them, one new leprosy patient was identified and started on treatment with multidrug therapy (MDT). All the eligible contacts, received the prophylactic treatment with Single Dose Rifampicin (SDR). Overall, SDR was administered to 133(98.5% of the listed contacts) with no adverse event reported. Factors associated with successful contact investigation and management included: Involvement of index patients, health care workers during the contact screening and SDR A administration, counselling of the index patients and contacts by the health care works, LPEP being administered as Directly observed Therapy (DOT) among others. Results Interpretation: The integration of leprosy post-exposure prophylaxis with administration of SDR and contact tracing is feasible, generally accepted by the patient, their contacts and health workers and can be integrated into the National Leprosy control programmes with minimal additional efforts once contact tracing has been established. Therefore, we recommend integration of administration of SDR in to the routine leprosy control program.展开更多
Helicobacter pylori(H.pylori)infections may cause chronic gastritis,peptic ulcer disease,gastric cancers,and other conditions outside of the gastrointestinal tract.Hence,it is important to diagnose and treat it early....Helicobacter pylori(H.pylori)infections may cause chronic gastritis,peptic ulcer disease,gastric cancers,and other conditions outside of the gastrointestinal tract.Hence,it is important to diagnose and treat it early.H.pylori is resistant to certain drugs in traditional eradication therapy,so alternative therapy protocols are needed,such as high-dose amoxicillin dual therapy(HDADT).This article aims to comment on a recent paper by Costigan et al in the World Journal of Clinical Cases.In this study,the authors recruited 139 patients diagnosed with H.pylori,all treated with HDADT.Of these,93 were treatment-naïve and 46 had received at least one alternative treatment in the past.Four weeks after the end of the treatment,the urea breath test was administered to estimate the eradication rate.The total eradication rate was 56%(78/139),62%for the treatment-naïve arm and 43%for the previous treatment arm,thus indicating a lower success rate for the arm that had previously received a different treatment regimen.In conclusion,a therapeutic approach with first-line HDADT may potentially be a better treat-ment,but the results are not sufficient to recommend the use of this regimen in a country with high levels of dual resistance.展开更多
Oxidative stress has been associated with a number of physiological problems in swine,including reduced production efficiency.Recently,although there has been increased research into regulatory mechanisms and antioxid...Oxidative stress has been associated with a number of physiological problems in swine,including reduced production efficiency.Recently,although there has been increased research into regulatory mechanisms and antioxidant strategies in relation to oxidative stress-induced pig production,it remains so far largely unsuccessful to develop accurate models and nutritional strategies for specific oxidative stress factors.Here,we discuss the dose and dose intensity of the causes of oxidative stress involving physiological,environmental and dietary factors,recent research models and the antioxidant strategies to provide theoretical guidance for future oxidative stress research in swine.展开更多
The Medium-Resolution Spectral Imager-Ⅱ(MERSI-Ⅱ)instrument aboard China’s Fengyun-3D satellite shares similarities with NASA’s Moderate Resolution Imaging Spectroradiometer(MODIS)sensor,enabling the retrieval of g...The Medium-Resolution Spectral Imager-Ⅱ(MERSI-Ⅱ)instrument aboard China’s Fengyun-3D satellite shares similarities with NASA’s Moderate Resolution Imaging Spectroradiometer(MODIS)sensor,enabling the retrieval of global aerosol optical depth(AOD).However,no officially released operational MERSI-Ⅱ aerosol products currently exist over the ocean.This study focuses on adapting the MODIS dark target(DT)ocean algorithm to the MERSI-Ⅱ sensor.A retrieval test is conducted on the 2019 MERSI-Ⅱ data over the global ocean,and the retrieved AODs are validated against ground-based measurements from the automatic Aerosol Robotic Network(AERONET)and the shipborne Maritime Aerosol Network(MAN).The operational MODIS DT aerosol products are also used for comparison purposes.The results show that MERSI-Ⅱ AOD granule retrievals are in good agreement with MODIS products,boasting high correlation coefficients(R)of up to 0.96 and consistent spatial distribution trends.Furthermore,the MERSI-Ⅱ retrievals perform well in comparison to AERONET and MAN measurements,with high R-values(>0.86).However,the low-value retrievals from MERSI-Ⅱ tend to be slightly overestimated compared to MODIS,despite both AODs displaying a positive bias.Notably,the monthly gridded AODs over the high latitudes of the northern and southern hemispheres suggest that MERSI-Ⅱ exhibits greater stability in space and time,effectively reducing unrealistically high-value noise in the MODIS products.These results illustrate that the MERSI-Ⅱ retrievals meet specific accuracy requirements by maintaining the algorithmic framework and most of the algorithmic assumptions,providing a crucial data supplement for aerosol studies and climate change.展开更多
Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irra...Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irradiators are Cs-137 OB6 irradiator and X-ray irradiators at the Protection level SSDL;and Co-60 irradiator at the Therapy Level SSDL. PTW UNIDOS electrometer and LS01 Ionization chamber were used at the Protection Level to obtain doses for both Cs-137 OB6 and X-ray irradiators while an IBA farmer type ionization chamber and an IBA DOSE 1 electrometer were used at the Protection Level SSDL. Single/multiple exposure method and graphical method were used in the determination of the timer error for the three irradiators. The timer error obtained for Cs-137 OB6 irradiator was 0.48 ± 0.01 s, the timer error for the X-ray irradiator was 0.09 ± 0.01 s while the timer error obtained for GammaBeam X200 was 1.21 ± 0.04 s. It was observed that the timer error is not affected by source to detector distance. It was also observed that the timer error of Co-60 Gamma X200 irradiator is increasing with the age of the machine. Source to detector distance and field size do not contribute towards the timer error of the irradiators. The timer error of the Co-60 Gamma X200 irradiator (the only irradiator among the irradiators with a pneumatic system) increases with the age of the irradiator.展开更多
Data-derived normal mode extraction is an effective method for extracting normal mode depth functions in the absence of marine environmental data.However,when the corresponding singular vectors become nonunique when t...Data-derived normal mode extraction is an effective method for extracting normal mode depth functions in the absence of marine environmental data.However,when the corresponding singular vectors become nonunique when two or more singular values obtained from the cross-spectral density matrix diagonalization are nearly equal,this results in unsatisfactory extraction outcomes for the normal mode depth functions.To address this issue,we introduced in this paper a range-difference singular value decomposition method for the extraction of normal mode depth functions.We performed the mode extraction by conducting singular value decomposition on the individual frequency components of the signal's cross-spectral density matrix.This was achieved by using pressure and its range-difference matrices constructed from vertical line array data.The proposed method was validated using simulated data.In addition,modes were successfully extracted from ambient noise.展开更多
Background: This study evaluated the bioequivalence of empagliflozin 12.5 mg/metformin 1000 mg tablets compared to Synjardy® (Empagliflozin 12.5 mg/metformin 1000 mg) tablets in healthy male subjects under fastin...Background: This study evaluated the bioequivalence of empagliflozin 12.5 mg/metformin 1000 mg tablets compared to Synjardy® (Empagliflozin 12.5 mg/metformin 1000 mg) tablets in healthy male subjects under fasting conditions. Methods: This was a phase I, randomized, single-dose, two-period, two-sequence, crossover study to evaluate the bioequivalence (BE) profiles of two fixed-dose combinations (FDCs) of empagliflozin/metformin. Cmax, AUC0-t and AUC0-∞ from test and reference formulations were evaluated to access BE. The plasma concentrations were measured using a validated liquid chromatography-mass spectrometry (LC-MS/MS) method. Of the 24 subjects enrolled, 23 completed both periods of the study. The two formulations test and reference were considered bioequivalent if 90% confidence interval (CI) fell within 80.00% - 125.00% for Cmax, AUC0-t and AUC0-∞. Tolerability and safety were assessed throughout the study. Results: The pharmacokinetic (PK) parameters were similar between the test product (T) and reference product (R) Synjardy®. The 90% CI of the test/reference ratios of log-transformed PK parameters point estimates was Cmax: 89.87% (85.68% - 94.27%), AUC0-t: 87.91% (83.65% - 92.39%) and AUC0-∞: 87.16% (82.80% - 91.75%) to empagliflozin and Cmax: 92.19% (87.95% - 96.65%), AUC0-t: 91.38% (84.42% - 98.91%) and AUC0-∞: 93.78% (83.82% - 104.93%) to metformin respectively (90% CI for all PK parameters fell within 80.00% - 125.00%). Conclusion: Our results demonstrated BE between the test and reference formulations of oral tablets of empagliflozin 12.5 mg/metformin 1000 mg (FDC) in healthy male subjects under fasting conditions.展开更多
The risk of radiation-induced second cancer and the late tissue loss due to Off-field doses in radiotherapy remain a serious concern. Monte Carlo (MC) simulation is currently one of the most accurate methods for calcu...The risk of radiation-induced second cancer and the late tissue loss due to Off-field doses in radiotherapy remain a serious concern. Monte Carlo (MC) simulation is currently one of the most accurate methods for calculating these doses. MC simulation model based on the Particle Simulation Tool (TOPAS) has been developed to simulate the off-field dose of an Elekta Synergy linear accelerator (Linac) emitting 6 MV photons. Measurements were taken in a water phantom using an ionization chamber to validate this model. The Percentage Depth Dose (PDD) at the depth of 0.0, 5.0, 10.0 and 15.0 cm from the beam axis for a 10 × 10 cm2 field size was measured and simulated. Off-field dose profiles at the depth of 1.5 (dmax), 5.0 and 10.0 cm for field sizes of 5 × 5, 10 × 10, 15 × 15, and 20 × 20 cm2 respectively were measured and simulated. Comparison of measured and simulated off-field dose values showed a good agreement. The average gamma passing rate of the PDDs and profiles curves for off-field doses were 87.5% and 98.11% respectively. The local dose difference based on the PDD curve between the measured and simulated was less than 6.0 % for all locations. For all field size considered in this study, the average difference between profile curves for off-field dose measured and simulated was 9.1%. PDDs and Profiles curves for off-field dose simulation uncertainties were less than 2.0% and 1.0% respectively. TOPAS-MC simulation model developed is a good representation of our 6 MV Linac Elekta Synergy for assessing off-field dose, which would be the primary cause of some secondary cancers.展开更多
Catalysis of molecular radicals is often performed in interesting experimental configurations.One possible configuration is tubular geometry.The radicals are introduced into the tubes on one side,and stable molecules ...Catalysis of molecular radicals is often performed in interesting experimental configurations.One possible configuration is tubular geometry.The radicals are introduced into the tubes on one side,and stable molecules are exhausted on the other side.The penetration depth of radicals depends on numerous parameters,so it is not always feasible to calculate it.This article presents systematic measurements of the penetration depth of oxygen atoms along tubes made from nickel,cobalt,and copper.The source of O atoms was a surfatron-type microwave plasma.The initial density of O atoms depended on the gas flow and was 0.7×10^(21)m^(-3),2.4×10^(21)m^(-3),and 4.2×10^(21)m^(-3)at the flow rates of 50,300,and 600 sccm,and pressures of 10,35,and 60 Pa,respectively.The gas temperature remained at room temperature throughout the experiments.The dissociation fraction decreased exponentially along the length of the tubes in all cases.The penetration depths for well-oxidized nickel were 1.2,1.7,and 2.4 cm,respectively.For cobalt,they were slightly lower at 1.0,1.3,and 1.6 cm,respectively,while for copper,they were 1.1,1.3,and 1.7 cm,respectively.The results were explained by gas dynamics and heterogeneous surface association.These data are useful in any attempt to estimate the loss of molecular fragments along tubes,which serve as catalysts for the association of various radicals to stable molecules.展开更多
文摘In this study, we fabricated a Cerenkov fiber-optic dosimeter (CFOD) without any scintillator to measure Cerenkov radiation signals owing to gamma-rays. The relative depth dose (RDD) distributions of Ir-192 HDR brachytherapy source were obtained by using the CFOD based on a subtraction method and the RDD curve was compared with the simulation result of Monte Carlo N-particle extended transport code (MCNPX). Finally, we demonstrated that the CFOD can be used to measure real-time dose information for HDR brachytherapy.
文摘Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date. This study is an investigating of percentage depth dose enhancement within the gel medium with the use of conformal distribution gold nanoparticle as contrast agents by high atomic number material. In this work, the normoxic polymer gel dosimeter MAGICA tissue-equivalence was first theoretically verified using MCNPX Monte Carlo code and experimentally by percentage depth dose curves within the gel medium. Then gold nanoparticles (GNPs) of 50 nm diameter with different concentrations of 0.1 mM, 0.2 mM, and 0.4 mM were embedded in MAGICA gel and irradiated by 18 MV photon beam. Experimental results have shown dose increase of 10%, 2% and 4% in 0.1 mM, 0.2 mM and 0.4 mM concentrations, respectively. Simulation results had good agreement in the optimum concentration of 0.1 mM. The largest error between experimental and simulation results was equal to 9.28% stood for 0.4 mM concentration. The results showed that the optimum concentration of gold nanoparticles to achieve maximum absorbed dose in both experimental and simulation was 0.1 mM and so it can be used for clinical studies.
文摘A formula describing the percentage depth dose curve for <sup>60</sup>Co γ beams is theoretically developed. The formula only needs a few data determined by measuring directly in water phantom and can be used to calculate the whole set of percentage depth dose (PDD) and tissuse air ratios (TAR) for the wide range of SSD (from 20cm to 100cm), field size (from 4cm×4cm to 20cm×20cm) and depth (from d<sub>m</sub> to 30cm). The data calculated by the formula fits very well to the data currently used in clinics with the maximum error less than 1% and probable error of about 0.1%-0.3%. Using this formula can overcome the time-exhausting work in measurement of PDD and TAR.
文摘BACKGROUND Helicobacter pylori(H.pylori)eradication rates have fallen globally,likely in large part due to increasing antibiotic resistance to traditional therapy.In areas of high clarithromycin and metronidazole resistance such as ours,Maastricht VI guidelines suggest high dose amoxicillin dual therapy(HDADT)can be considered,subject to evidence for local efficacy.In this study we assess efficacy of HDADT therapy for H.pylori eradication in an Irish cohort.AIM To assess the efficacy of HDADT therapy for H.pylori eradication in an Irish cohort as both first line,and subsequent therapy for patients diagnosed with H.pylori.METHODS All patients testing positive for H.pylori in a tertiary centre were treated prospectively with HDADT(amoxicillin 1 g tid and esomeprazole 40 mg bid×14 d)over a period of 8 months.Eradication was confirmed with Urea Breath Test at least 4 wk after cessation of therapy.A delta-over-baseline>4%was considered positive.Patient demographics and treatment outcomes were recorded,analysed and controlled for basic demographics and prior H.pylori treatment.RESULTS One hundred and ninety-eight patients were identified with H.pylori infection,10 patients were excluded due to penicillin allergy and 38 patients refused follow up testing.In all 139 were included in the analysis,55%(n=76)were female,mean age was 46.6 years.Overall,93(67%)of patients were treatment-naïve and 46(33%)had received at least one previous course of treatment.The groups were statistically similar.Self-reported compliance with HDADT was 97%,mild side-effects occurred in 7%.There were no serious adverse drug reactions.Overall the eradication rate for our cohort was 56%(78/139).Eradication rates were worse for those with previous treatment[43%(20/46)vs 62%(58/93),P=0.0458,odds ratio=2.15].Age and Gender had no effect on eradication status.CONCLUSION Overall eradication rates with HDADT were disappointing.Despite being a simple and possibly better tolerated regime,these results do not support its routine use in a high dual resistance country.Further investigation of other regimens to achieve the>90%eradication target is needed.
基金supports from the Research Grants Council of the Hong Kong Special Administrative Region,China[Project No.C5031-22GCityU11310522+3 种基金CityU11300123]the Department of Science and Technology of Guangdong Province[Project No.2020B1515120073]City University of Hong Kong[Project No.9610628]JST CREST(Grant No.JPMJCR1904).
文摘The increasing popularity of the metaverse has led to a growing interest and market size in spatial computing from both academia and industry.Developing portable and accurate imaging and depth sensing systems is crucial for advancing next-generation virtual reality devices.This work demonstrates an intelligent,lightweight,and compact edge-enhanced depth perception system that utilizes a binocular meta-lens for spatial computing.The miniaturized system comprises a binocular meta-lens,a 532 nm filter,and a CMOS sensor.For disparity computation,we propose a stereo-matching neural network with a novel H-Module.The H-Module incorporates an attention mechanism into the Siamese network.The symmetric architecture,with cross-pixel interaction and cross-view interaction,enables a more comprehensive analysis of contextual information in stereo images.Based on spatial intensity discontinuity,the edge enhancement eliminates illposed regions in the image where ambiguous depth predictions may occur due to a lack of texture.With the assistance of deep learning,our edge-enhanced system provides prompt responses in less than 0.15 seconds.This edge-enhanced depth perception meta-lens imaging system will significantly contribute to accurate 3D scene modeling,machine vision,autonomous driving,and robotics development.
基金supported by the National Key R&D Program of China(No.2022YFC2402300)National Natural Science Foundation of China(No.12075330)。
文摘Ultrahigh-dose-rate radiotherapy(FLASH-RT)is a revolutionary radiotherapy technology that can spare normal tissues without compromising tumor control.Although qualitative experimental results have been reported,quantitative and systematic analysis of data is necessary.Particularly,the FLASH effect response model to the dose or dose rate is still unclear.This study investigated the relationships between the FLASH effect and experimental parameters,such as dose,dose rate,and other factors by analyzing published in vivo experimental data from animal models.The data were modeled based on logistic regression analysis using the sigmoid function.The model was evaluated using prediction accuracy,receiver operating characteristic(ROC)curve,and area under the ROC curve.Results showed that the FLASH effect was closely related to the dose,mean dose rate,tissue type,and corresponding biological endpoints.The dose rate corresponding to a 50% probability of triggering cognitive protection in the brain was 45 Gy s^(-1).The dose rate corresponding to a 50% probability of triggering intestinal crypt survival and regeneration was 140 Gy s^(-1).For the skin toxicity effect,the dose corresponding to a 50% probability of triggering the FLASH effect was 24 Gy.This study helps to characterize the conditions underlying the FLASH effect and provides important information for optimizing experiments.
基金Project supported by JST-PRESTO (Grant No.JPMJPR1871)JST-FOREST (Grant No.JPMJFR2033)+2 种基金JST-ERATO (Grant No.JPMJER2202)KAKENHI JSPS (Grant Nos.JP19H05788,JP21H01614,and JP24H00373)“Next Generation Electron Microscopy”social cooperation program at the University of Tokyo。
文摘One of the major innovations awaiting in electron microscopy is full three-dimensional imaging at atomic resolution.Despite the success of aberration correction to deep sub-angstrom lateral resolution,spatial resolution in depth is still far from atomic resolution.In scanning transmission electron microscopy(STEM),this poor depth resolution is due to the limitation of the illumination angle.To overcome this physical limitation,it is essential to implement a next-generation aberration corrector in STEM that can significantly improve the depth resolution.This review discusses the capability of depth sectioning for three-dimensional imaging combined with large-angle illumination STEM.Furthermore,the statistical analysis approach remarkably improves the depth resolution,making it possible to achieve three-dimensional atomic resolution imaging at oxide surfaces.We will also discuss the future prospects of three-dimensional imaging at atomic resolution by STEM depth sectioning.
文摘The dependence of groundwater quality on borehole depth is usually debatable in groundwater studies, especially in complex geological formations where aquifer characteristics vary spatially with depth. This study therefore seeks to investigate the relationship between borehole depth and groundwater quality across the granitoid aquifers within the Birimian Supergroup in the Ashanti Region. Physicochemical analysis records of groundwater quality data were collected from 23 boreholes of public and private institutions in the Ashanti Region of Ghana, and the parametric values of iron, fluoride, total hardness, pH, nitrate, and nitrite were used to study the groundwater quality-depth relationship. The results showed that the depth-to-groundwater quality indicated a marginal increase in water quality in the range of 30 to 50 m, which is mathematically represented by the low-value correlation coefficient (r<sup>2</sup> = 0.026). A relatively significant increase occurs in the depth range of 50 to 80 m, which is given by a correlation coefficient of r<sup>2</sup> = 0.298. The mean percent parameter compatibility was 74%, 82%, 89%, and 97% at 50, 60, 70, and 80 m depths, respectively. The variations in groundwater quality per depth ratio ranged from 1.48, 1.37, 1.27, and 1.21 for 50, 60, 70, and 80 m depth, respectively. The recommended minimum borehole depth for excellent groundwater quality is suggested with a compatibility per meter depth ratio of 1.37. This results in a range between 50 and 70 m as the most desirable drilling depth for excellent groundwater quality within the granitoids of the Birimian Supergroup of the Ashanti Region in Ghana.
基金the Grant of Program for Scientific ResearchInnovation Team in Colleges and Universities of Anhui Province(2022AH010095)The Grant ofScientific Research and Talent Development Foundation of the Hefei University(No.21-22RC15)+2 种基金The Key Research Plan of Anhui Province(No.2022k07020011)The Grant of Anhui Provincial940 CMC,2024,vol.79,no.1Natural Science Foundation,No.2308085MF213The Open Fund of Information Materials andIntelligent Sensing Laboratory of Anhui Province IMIS202205,as well as the AI General ComputingPlatform of Hefei University.
文摘Depth estimation is an important task in computer vision.Collecting data at scale for monocular depth estimation is challenging,as this task requires simultaneously capturing RGB images and depth information.Therefore,data augmentation is crucial for this task.Existing data augmentationmethods often employ pixel-wise transformations,whichmay inadvertently disrupt edge features.In this paper,we propose a data augmentationmethod formonocular depth estimation,which we refer to as the Perpendicular-Cutdepth method.This method involves cutting realworld depth maps along perpendicular directions and pasting them onto input images,thereby diversifying the data without compromising edge features.To validate the effectiveness of the algorithm,we compared it with existing convolutional neural network(CNN)against the current mainstream data augmentation algorithms.Additionally,to verify the algorithm’s applicability to Transformer networks,we designed an encoder-decoder network structure based on Transformer to assess the generalization of our proposed algorithm.Experimental results demonstrate that,in the field of monocular depth estimation,our proposed method,Perpendicular-Cutdepth,outperforms traditional data augmentationmethods.On the indoor dataset NYU,our method increases accuracy from0.900 to 0.907 and reduces the error rate from0.357 to 0.351.On the outdoor dataset KITTI,our method improves accuracy from 0.9638 to 0.9642 and decreases the error rate from 0.060 to 0.0598.
文摘Background: World Health Organization recommends the implementation of contact tracing and Leprosy Post Exposure prophylaxis (LPEP) to interrupt the chain of transmission. To accelerate the uptake of this recommendation, a cross-sectional study among contacts of leprosy patients was conducted to investigate the feasibility of integrating leprosy systematic contact tracing and post-exposure prophylaxis (PEP) into the routine leprosy control program. Methods: This was a mixed methods cross-sectional study. The study was implemented in Kumi, Ngora, Serere, Soroti, Budaka and Kibuku Districts. Results: The 45 enrolled index patients (97.8% of the registered) identified a total of 135 contacts, of which 134 (99·2%) consented and were screened. Among them, one new leprosy patient was identified and started on treatment with multidrug therapy (MDT). All the eligible contacts, received the prophylactic treatment with Single Dose Rifampicin (SDR). Overall, SDR was administered to 133(98.5% of the listed contacts) with no adverse event reported. Factors associated with successful contact investigation and management included: Involvement of index patients, health care workers during the contact screening and SDR A administration, counselling of the index patients and contacts by the health care works, LPEP being administered as Directly observed Therapy (DOT) among others. Results Interpretation: The integration of leprosy post-exposure prophylaxis with administration of SDR and contact tracing is feasible, generally accepted by the patient, their contacts and health workers and can be integrated into the National Leprosy control programmes with minimal additional efforts once contact tracing has been established. Therefore, we recommend integration of administration of SDR in to the routine leprosy control program.
文摘Helicobacter pylori(H.pylori)infections may cause chronic gastritis,peptic ulcer disease,gastric cancers,and other conditions outside of the gastrointestinal tract.Hence,it is important to diagnose and treat it early.H.pylori is resistant to certain drugs in traditional eradication therapy,so alternative therapy protocols are needed,such as high-dose amoxicillin dual therapy(HDADT).This article aims to comment on a recent paper by Costigan et al in the World Journal of Clinical Cases.In this study,the authors recruited 139 patients diagnosed with H.pylori,all treated with HDADT.Of these,93 were treatment-naïve and 46 had received at least one alternative treatment in the past.Four weeks after the end of the treatment,the urea breath test was administered to estimate the eradication rate.The total eradication rate was 56%(78/139),62%for the treatment-naïve arm and 43%for the previous treatment arm,thus indicating a lower success rate for the arm that had previously received a different treatment regimen.In conclusion,a therapeutic approach with first-line HDADT may potentially be a better treat-ment,but the results are not sufficient to recommend the use of this regimen in a country with high levels of dual resistance.
基金supported by Guangzhou Science and Technology Planning Project(2023A04J0131)Special fund for scientific innovation strategyconstruction of high level Academy of Agriculture Science(R2020PY-JG009,R2022PY-QY007,202106TD)+2 种基金China Agriculture Research System-CARS-35the Project of Swine Innovation Team in Guangdong Modern Agricultural Research System(2022KJ126)Special Fund for Rural Revitalization Strategy of Guangdong(2023TS-3),China。
文摘Oxidative stress has been associated with a number of physiological problems in swine,including reduced production efficiency.Recently,although there has been increased research into regulatory mechanisms and antioxidant strategies in relation to oxidative stress-induced pig production,it remains so far largely unsuccessful to develop accurate models and nutritional strategies for specific oxidative stress factors.Here,we discuss the dose and dose intensity of the causes of oxidative stress involving physiological,environmental and dietary factors,recent research models and the antioxidant strategies to provide theoretical guidance for future oxidative stress research in swine.
基金supported in part by the National Natural Science Foundation of China(Grant Nos.42471424,41975036,and 42075132)the Fengyun Application Pioneering Project(Grant No.FY-APP024)+1 种基金the State Key Project of National Natural Science Foundation of China-Key projects of joint fund for regional innovation and development(Grant No.U22A20566)the Scientific and Technological Innovation Team of Universities in Henan Province(Grant No.22IRTSTHN008).
文摘The Medium-Resolution Spectral Imager-Ⅱ(MERSI-Ⅱ)instrument aboard China’s Fengyun-3D satellite shares similarities with NASA’s Moderate Resolution Imaging Spectroradiometer(MODIS)sensor,enabling the retrieval of global aerosol optical depth(AOD).However,no officially released operational MERSI-Ⅱ aerosol products currently exist over the ocean.This study focuses on adapting the MODIS dark target(DT)ocean algorithm to the MERSI-Ⅱ sensor.A retrieval test is conducted on the 2019 MERSI-Ⅱ data over the global ocean,and the retrieved AODs are validated against ground-based measurements from the automatic Aerosol Robotic Network(AERONET)and the shipborne Maritime Aerosol Network(MAN).The operational MODIS DT aerosol products are also used for comparison purposes.The results show that MERSI-Ⅱ AOD granule retrievals are in good agreement with MODIS products,boasting high correlation coefficients(R)of up to 0.96 and consistent spatial distribution trends.Furthermore,the MERSI-Ⅱ retrievals perform well in comparison to AERONET and MAN measurements,with high R-values(>0.86).However,the low-value retrievals from MERSI-Ⅱ tend to be slightly overestimated compared to MODIS,despite both AODs displaying a positive bias.Notably,the monthly gridded AODs over the high latitudes of the northern and southern hemispheres suggest that MERSI-Ⅱ exhibits greater stability in space and time,effectively reducing unrealistically high-value noise in the MODIS products.These results illustrate that the MERSI-Ⅱ retrievals meet specific accuracy requirements by maintaining the algorithmic framework and most of the algorithmic assumptions,providing a crucial data supplement for aerosol studies and climate change.
文摘Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irradiators are Cs-137 OB6 irradiator and X-ray irradiators at the Protection level SSDL;and Co-60 irradiator at the Therapy Level SSDL. PTW UNIDOS electrometer and LS01 Ionization chamber were used at the Protection Level to obtain doses for both Cs-137 OB6 and X-ray irradiators while an IBA farmer type ionization chamber and an IBA DOSE 1 electrometer were used at the Protection Level SSDL. Single/multiple exposure method and graphical method were used in the determination of the timer error for the three irradiators. The timer error obtained for Cs-137 OB6 irradiator was 0.48 ± 0.01 s, the timer error for the X-ray irradiator was 0.09 ± 0.01 s while the timer error obtained for GammaBeam X200 was 1.21 ± 0.04 s. It was observed that the timer error is not affected by source to detector distance. It was also observed that the timer error of Co-60 Gamma X200 irradiator is increasing with the age of the machine. Source to detector distance and field size do not contribute towards the timer error of the irradiators. The timer error of the Co-60 Gamma X200 irradiator (the only irradiator among the irradiators with a pneumatic system) increases with the age of the irradiator.
基金supported in part by the Young Scientists Fund of National Natural Science Foundation of China (No.42206226)the National Key Research and Development Program of China (No.2021YFC3101603)。
文摘Data-derived normal mode extraction is an effective method for extracting normal mode depth functions in the absence of marine environmental data.However,when the corresponding singular vectors become nonunique when two or more singular values obtained from the cross-spectral density matrix diagonalization are nearly equal,this results in unsatisfactory extraction outcomes for the normal mode depth functions.To address this issue,we introduced in this paper a range-difference singular value decomposition method for the extraction of normal mode depth functions.We performed the mode extraction by conducting singular value decomposition on the individual frequency components of the signal's cross-spectral density matrix.This was achieved by using pressure and its range-difference matrices constructed from vertical line array data.The proposed method was validated using simulated data.In addition,modes were successfully extracted from ambient noise.
文摘Background: This study evaluated the bioequivalence of empagliflozin 12.5 mg/metformin 1000 mg tablets compared to Synjardy® (Empagliflozin 12.5 mg/metformin 1000 mg) tablets in healthy male subjects under fasting conditions. Methods: This was a phase I, randomized, single-dose, two-period, two-sequence, crossover study to evaluate the bioequivalence (BE) profiles of two fixed-dose combinations (FDCs) of empagliflozin/metformin. Cmax, AUC0-t and AUC0-∞ from test and reference formulations were evaluated to access BE. The plasma concentrations were measured using a validated liquid chromatography-mass spectrometry (LC-MS/MS) method. Of the 24 subjects enrolled, 23 completed both periods of the study. The two formulations test and reference were considered bioequivalent if 90% confidence interval (CI) fell within 80.00% - 125.00% for Cmax, AUC0-t and AUC0-∞. Tolerability and safety were assessed throughout the study. Results: The pharmacokinetic (PK) parameters were similar between the test product (T) and reference product (R) Synjardy®. The 90% CI of the test/reference ratios of log-transformed PK parameters point estimates was Cmax: 89.87% (85.68% - 94.27%), AUC0-t: 87.91% (83.65% - 92.39%) and AUC0-∞: 87.16% (82.80% - 91.75%) to empagliflozin and Cmax: 92.19% (87.95% - 96.65%), AUC0-t: 91.38% (84.42% - 98.91%) and AUC0-∞: 93.78% (83.82% - 104.93%) to metformin respectively (90% CI for all PK parameters fell within 80.00% - 125.00%). Conclusion: Our results demonstrated BE between the test and reference formulations of oral tablets of empagliflozin 12.5 mg/metformin 1000 mg (FDC) in healthy male subjects under fasting conditions.
文摘The risk of radiation-induced second cancer and the late tissue loss due to Off-field doses in radiotherapy remain a serious concern. Monte Carlo (MC) simulation is currently one of the most accurate methods for calculating these doses. MC simulation model based on the Particle Simulation Tool (TOPAS) has been developed to simulate the off-field dose of an Elekta Synergy linear accelerator (Linac) emitting 6 MV photons. Measurements were taken in a water phantom using an ionization chamber to validate this model. The Percentage Depth Dose (PDD) at the depth of 0.0, 5.0, 10.0 and 15.0 cm from the beam axis for a 10 × 10 cm2 field size was measured and simulated. Off-field dose profiles at the depth of 1.5 (dmax), 5.0 and 10.0 cm for field sizes of 5 × 5, 10 × 10, 15 × 15, and 20 × 20 cm2 respectively were measured and simulated. Comparison of measured and simulated off-field dose values showed a good agreement. The average gamma passing rate of the PDDs and profiles curves for off-field doses were 87.5% and 98.11% respectively. The local dose difference based on the PDD curve between the measured and simulated was less than 6.0 % for all locations. For all field size considered in this study, the average difference between profile curves for off-field dose measured and simulated was 9.1%. PDDs and Profiles curves for off-field dose simulation uncertainties were less than 2.0% and 1.0% respectively. TOPAS-MC simulation model developed is a good representation of our 6 MV Linac Elekta Synergy for assessing off-field dose, which would be the primary cause of some secondary cancers.
基金funded by the Slovenian Research Agency,Core Funding(No.P2-0082)and Project(No.L24487)。
文摘Catalysis of molecular radicals is often performed in interesting experimental configurations.One possible configuration is tubular geometry.The radicals are introduced into the tubes on one side,and stable molecules are exhausted on the other side.The penetration depth of radicals depends on numerous parameters,so it is not always feasible to calculate it.This article presents systematic measurements of the penetration depth of oxygen atoms along tubes made from nickel,cobalt,and copper.The source of O atoms was a surfatron-type microwave plasma.The initial density of O atoms depended on the gas flow and was 0.7×10^(21)m^(-3),2.4×10^(21)m^(-3),and 4.2×10^(21)m^(-3)at the flow rates of 50,300,and 600 sccm,and pressures of 10,35,and 60 Pa,respectively.The gas temperature remained at room temperature throughout the experiments.The dissociation fraction decreased exponentially along the length of the tubes in all cases.The penetration depths for well-oxidized nickel were 1.2,1.7,and 2.4 cm,respectively.For cobalt,they were slightly lower at 1.0,1.3,and 1.6 cm,respectively,while for copper,they were 1.1,1.3,and 1.7 cm,respectively.The results were explained by gas dynamics and heterogeneous surface association.These data are useful in any attempt to estimate the loss of molecular fragments along tubes,which serve as catalysts for the association of various radicals to stable molecules.