Objective To develop a highly sensitive and rapid nucleic acid detection method for the severe acute respiratory syndrome coronavirus 2(SARS-CoV-2).Methods We designed,developed,and manufactured an integrated disposab...Objective To develop a highly sensitive and rapid nucleic acid detection method for the severe acute respiratory syndrome coronavirus 2(SARS-CoV-2).Methods We designed,developed,and manufactured an integrated disposable device for SARS-CoV-2 nucleic acid extraction and detection.The precision of the liquid transfer and temperature control was tested.A comparison between our device and a commercial kit for SARS-Cov-2 nucleic acid extraction was performed using real-time fluorescence reverse transcription polymerase chain reaction(RT-PCR).The entire process,from SARS-CoV-2 nucleic acid extraction to amplification,was evaluated.Results The precision of the syringe transfer volume was 19.2±1.9μL(set value was 20),32.2±1.6(set value was 30),and 57.2±3.5(set value was 60).Temperature control in the amplification tube was measured at 60.0±0.0℃(set value was 60)and 95.1±0.2℃(set value was 95)respectively.SARS-Cov-2 nucleic acid extraction yield through the device was 7.10×10^(6) copies/mL,while a commercial kit yielded 2.98×10^(6) copies/mL.The mean time to complete the entire assay,from SARS-CoV-2 nucleic acid extraction to amplification detection,was 36 min and 45 s.The detection limit for SARS-CoV-2 nucleic acid was 250 copies/mL.Conclusion The integrated disposable devices may be used for SARS-CoV-2 Point-of-Care test(POCT).展开更多
A novel strategy was developed to fabricate FeNx-doped carbon quantum dots(Fe-N-CQDs)to detect Cu^(2+) ions selectively as a fluorescence probe.The Fe-N-CQDs were synthesized by an efficient electrolysis of a carbon c...A novel strategy was developed to fabricate FeNx-doped carbon quantum dots(Fe-N-CQDs)to detect Cu^(2+) ions selectively as a fluorescence probe.The Fe-N-CQDs were synthesized by an efficient electrolysis of a carbon cloth electrode,which was coated with monoatomic ironanchored nitrogen-doped carbon(Fe-N-C).The obtained Fe-N-CQDs emitted blue fluorescence and possessed a quantum yield(QY)of 7.5%.An extremely wide linear relationship between the Cu^(2+) concentration and the fluorescence intensity was obtained in the range from 100 nmol L^(-1) to 1000 nmol L^(-1)(R^(2)=0.997),and the detection limit was calculated as 59 nmol L^(-1).Moreover,the Fe-N-CQDs demonstrated wide range pH compatibility between 2 and 13 due to the coordination between pyridine nitrogen and Fe^(3+),which dramatically reduced the affection of the protonation and deprotonation process between H^(+) and Fe-N-CQDs.It is notable that the Fe-N-CQDs exhibited a rapid response in Cu^(2+) detection,where stable quenching can be completed in 7 s.The mechanism of excellent selective detection of Cu^(2+) was revealed by energy level simulation that the LUMO level of Fe-N-CQDs(-4.37 eV)was close to the redox potential of Cu^(2+),thus facilitating the electron transport from Fe-N-CQDs to Cu^(2+).展开更多
Copper-based nanomaterials have been widely used in catalysis,electrodes,and other applications due to their unique electron-transfer properties.In this work,an efficient electrochemical sensor based on an electrode m...Copper-based nanomaterials have been widely used in catalysis,electrodes,and other applications due to their unique electron-transfer properties.In this work,an efficient electrochemical sensor based on an electrode modified with one-dimensional Cu(OH)_(2)/carboxymethyl cellulose(CMC)composite nanofibers was fabricated and investigated for the detection of aspirin.Scanning electron microscopy was employed to examine the morphological characteristics of these composite nanofibers.Cyclic voltammetry and electrochemical impedance spectroscopy were used to assess the electrochemical performance of a Cu(OH)_(2)/CMC composite nanofiber-modified electrode.The findings indicate that the modified electrode has a very high sensitivity to aspirin.The observed enhanced performance could be a result of the high surface-to-volume ratio of the composite nanofibers and their superior electron-transport characteristics,which may hasten electron transfer between aspirin and the surfaces of the modified electrode.This detection technique also demonstrated strong selectivity for aspirin.These findings imply that the technique can be applied as a highly effective and selective approach to aspirin measurement in biological science.展开更多
基金supported by National Key R&D Program of China[2021YFC2301103 and 2022YFE0202600]Shenzhen Science and Technology Program[JSGG20220606142605011].
文摘Objective To develop a highly sensitive and rapid nucleic acid detection method for the severe acute respiratory syndrome coronavirus 2(SARS-CoV-2).Methods We designed,developed,and manufactured an integrated disposable device for SARS-CoV-2 nucleic acid extraction and detection.The precision of the liquid transfer and temperature control was tested.A comparison between our device and a commercial kit for SARS-Cov-2 nucleic acid extraction was performed using real-time fluorescence reverse transcription polymerase chain reaction(RT-PCR).The entire process,from SARS-CoV-2 nucleic acid extraction to amplification,was evaluated.Results The precision of the syringe transfer volume was 19.2±1.9μL(set value was 20),32.2±1.6(set value was 30),and 57.2±3.5(set value was 60).Temperature control in the amplification tube was measured at 60.0±0.0℃(set value was 60)and 95.1±0.2℃(set value was 95)respectively.SARS-Cov-2 nucleic acid extraction yield through the device was 7.10×10^(6) copies/mL,while a commercial kit yielded 2.98×10^(6) copies/mL.The mean time to complete the entire assay,from SARS-CoV-2 nucleic acid extraction to amplification detection,was 36 min and 45 s.The detection limit for SARS-CoV-2 nucleic acid was 250 copies/mL.Conclusion The integrated disposable devices may be used for SARS-CoV-2 Point-of-Care test(POCT).
基金the National Natural Science Foundation of China(Nos.21776302 and 21776308)the Science Foundation of China University of Petroleum,Beijing(No.2462020YXZZ033).
文摘A novel strategy was developed to fabricate FeNx-doped carbon quantum dots(Fe-N-CQDs)to detect Cu^(2+) ions selectively as a fluorescence probe.The Fe-N-CQDs were synthesized by an efficient electrolysis of a carbon cloth electrode,which was coated with monoatomic ironanchored nitrogen-doped carbon(Fe-N-C).The obtained Fe-N-CQDs emitted blue fluorescence and possessed a quantum yield(QY)of 7.5%.An extremely wide linear relationship between the Cu^(2+) concentration and the fluorescence intensity was obtained in the range from 100 nmol L^(-1) to 1000 nmol L^(-1)(R^(2)=0.997),and the detection limit was calculated as 59 nmol L^(-1).Moreover,the Fe-N-CQDs demonstrated wide range pH compatibility between 2 and 13 due to the coordination between pyridine nitrogen and Fe^(3+),which dramatically reduced the affection of the protonation and deprotonation process between H^(+) and Fe-N-CQDs.It is notable that the Fe-N-CQDs exhibited a rapid response in Cu^(2+) detection,where stable quenching can be completed in 7 s.The mechanism of excellent selective detection of Cu^(2+) was revealed by energy level simulation that the LUMO level of Fe-N-CQDs(-4.37 eV)was close to the redox potential of Cu^(2+),thus facilitating the electron transport from Fe-N-CQDs to Cu^(2+).
基金The authors wish to acknowledge financial support from the Science and Technology Projects in Jilin Province Department of Education(Grant No.JJKH20220239KJ).
文摘Copper-based nanomaterials have been widely used in catalysis,electrodes,and other applications due to their unique electron-transfer properties.In this work,an efficient electrochemical sensor based on an electrode modified with one-dimensional Cu(OH)_(2)/carboxymethyl cellulose(CMC)composite nanofibers was fabricated and investigated for the detection of aspirin.Scanning electron microscopy was employed to examine the morphological characteristics of these composite nanofibers.Cyclic voltammetry and electrochemical impedance spectroscopy were used to assess the electrochemical performance of a Cu(OH)_(2)/CMC composite nanofiber-modified electrode.The findings indicate that the modified electrode has a very high sensitivity to aspirin.The observed enhanced performance could be a result of the high surface-to-volume ratio of the composite nanofibers and their superior electron-transport characteristics,which may hasten electron transfer between aspirin and the surfaces of the modified electrode.This detection technique also demonstrated strong selectivity for aspirin.These findings imply that the technique can be applied as a highly effective and selective approach to aspirin measurement in biological science.