期刊文献+
共找到44篇文章
< 1 2 3 >
每页显示 20 50 100
Electroanalysis and simultaneous determination of dopamine and epinephrine at poly(isonicotinic acid)-modified carbon paste electrode in the presence of ascorbic acid 被引量:4
1
作者 Yuan Zhen Zhou Li Juan Zhang +2 位作者 Shuang Li Chen She Ying Dong Xiao Hui Zheng 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第2期217-220,共4页
A carbon paste electrode modified with electropolymerized fills of isonicotinic acid was developed. The modified electrode shows excellent electrocatalytic activity toward the oxidation of both dopamine (DA) and epi... A carbon paste electrode modified with electropolymerized fills of isonicotinic acid was developed. The modified electrode shows excellent electrocatalytic activity toward the oxidation of both dopamine (DA) and epinephrine (EP). Separation of the reduction peak potentials for dopamine and epinephrine was about 357 mV in pH 5.3 phosphate buffer solution (PBS) and the character was used for the detection DA and EP simultaneously. The peak currents increase linearly with DA and EP concentration over the range of 8.0×10^-5 to 7.0×10^-4 mol/L and 5.0×10^-6 to 1.0×10^-4 mol/L with detection limits of 2×10^-5 and 1×10^-6 mol/L, respectively. The interference studies showed that the modified electrode exhibits excellent selectivity in the presence of large excess of ascorbic acid (AA). 展开更多
关键词 DOPAMINE EPINEPHRINE Isonicotinic acid Ascorbic acid Simultaneous determination
下载PDF
Simultaneous Determination of Bisphenols and Alkylphenols in Water by Solid Phase Extraction and Ultra Performance Liquid Chromatography-tandem Mass Spectrometry 被引量:4
2
作者 SHAN Xiao Mei SHEN Deng Hui +2 位作者 WANG Bing Shuang LU Bei Bei HUANG Fa Yuan 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第6期471-474,共4页
To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry ... To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%. 展开更多
关键词 UPLC BPA Simultaneous Determination of Bisphenols and Alkylphenols in Water by Solid Phase Extraction and Ultra Performance Liquid Chromatography-tandem Mass Spectrometry MASS
下载PDF
2,3-Dimercaptosuccinic acid self-assembled gold electrode for the simultaneous determination of epinephrine and dopamine 被引量:1
3
作者 Wei Jun Kang Ling Mei Niu Li Ma 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第2期221-224,共4页
Simultaneous determination of epinephrine (EP) and dopamine (DA) at 2,3-dimercaptosuccinic acid (DMSA) modified electrode was studied. The oxidation peaks of the mixture of EP and DA appeared at the same potenti... Simultaneous determination of epinephrine (EP) and dopamine (DA) at 2,3-dimercaptosuccinic acid (DMSA) modified electrode was studied. The oxidation peaks of the mixture of EP and DA appeared at the same potential, but the cathodic peak currents were only linear to the concentration of DA, whereas the anodic peak currents were equal to the sum of individual anodic peak currents of EP and DA. Therefore, a novel electrochemical method for the simultaneous determination of EP and DA at a DMSA modified electrode (DMSA/Au electrode) by cyclic voltammetry was established. The DMSA self-assembled electrode showed good sensitivity, selectivity and stability and could be used to determine DA and EP, simultaneously, in the real application with satisfactory results. 展开更多
关键词 2 3-Dimercaptosuccinic acid Simultaneous determination DOPAMINE EPINEPHRINE
下载PDF
Simultaneous Spectrophotometric Determination of Three Components Including Deoxyschizandrin by Partial Least Squares Regression 被引量:1
4
作者 张立庆 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2005年第3期119-121,共3页
The computer auxiliary partial least squares is introduced to simultaneously determine the contents of Deoxyschizandin, Schisandrin, r-Schisandrin in the extracted solution of wuweizi. Regression analysis of the exper... The computer auxiliary partial least squares is introduced to simultaneously determine the contents of Deoxyschizandin, Schisandrin, r-Schisandrin in the extracted solution of wuweizi. Regression analysis of the experimental results shows that the average recovery of each component is all in the range from 98.9% to 110.3% , which means the partial least squares regression spectrophotometry can circumvent the overlappirtg of absorption spectrums of mlulti-components, so that sctisfactory results can be obtained without any scrapple pre-separation. 展开更多
关键词 DEOXYSCHIZANDRIN partial least squares regression spectrophotometry simultaneous determination
下载PDF
Simultaneous Determination of Gold and Platinum by Double Artificial Neural Network Analysis with Flow-injection Chemiluminescence 被引量:1
5
作者 Ming Yang LIU Hai Tao ZHANG Jun Feng LI Shu Gui CHEN Hong Yan WANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第10期1343-1346,共4页
A highly sensitive double artificial neural network (DANN) analysis with flow-injection chemiluminescence (FI-CL) has been developed to simultaneously determine the trace amounts of the gold and platinum in simula... A highly sensitive double artificial neural network (DANN) analysis with flow-injection chemiluminescence (FI-CL) has been developed to simultaneously determine the trace amounts of the gold and platinum in simulated mixed samples, without the boring process. 展开更多
关键词 Double artificial neural networks FLOW-INJECTION CHEMILUMINESCENCE simultaneous determination gold and platinum.
下载PDF
Nitrogen-doped carbon@TiO_(2) double-shelled hollow spheres as an electrochemical sensor for simultaneous determination of dopamine and paracetamol in human serum and saliva 被引量:1
6
作者 Hui Yang Gongxun Cao +5 位作者 Yongjun Huang Ye Lin Fengying Zheng Luxiu Lin Fengjiao Liu Shunxing Li 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2022年第3期436-445,共10页
As the most commonly used antipyretic and analgesic drug,paracetamol(PA)coexists with neurotransmitter dopamine(DA)in real biological samples.Their simultaneous determination is extremely important for human health,bu... As the most commonly used antipyretic and analgesic drug,paracetamol(PA)coexists with neurotransmitter dopamine(DA)in real biological samples.Their simultaneous determination is extremely important for human health,but they also interfere with each other.In order to improve the conductivity,adsorption affinity,sensitivity,and selectivity of TiO_(2)-based electrochemical sensor,N-doped carbon@-TiO_(2) double-shelled hollow sphere(HeC/N@TiO_(2))is designed and synthesized by simple alcoholic and hydrothermal method,using polystyrene sphere(PS)as a template.Meanwhile,TiO_(2) hollow spheres(H eTiO_(2))or N-doped carbon hollow spheres(HeC/N)are also prepared by the same method.HeC/N@TiO_(2) has good conductivity,charge separation,and the highly enhanced and stable current responses for the detection of PA and DA.The detection limit and linear range are 50.0 nmol/L and 0.3-50 mmol/L for PA,40.0 nmol/L and 0.3e50 mmol/L for DA,respectively,which are better than those of carbon-based sensors.Moreover,this electrochemical sensor,with high selectivity,strong anti-interference,high reliability,and long time durability,can be used for the simultaneous detection of PA and DA in human blood serum and saliva.The high electrochemical performance of HeC/N@TiO_(2) is attributed to the multifunctional combination of different layers,because of good conductivity,absorption and electrons transfer ability from in-situ N-doped carbon and electrocatalytic activity from TiO_(2). 展开更多
关键词 Electrochemical sensor Simultaneous determination PARACETAMOL DOPAMINE
下载PDF
Application and verification of simultaneous determination of cellulose δ^(13)C and δ^(18)O in Picea shrenkiana tree rings from northwestern China using the high-temperature pyrolysis method 被引量:1
7
作者 XU Guobao LIU Xiaohong +6 位作者 SUN Weizhen CHEN Tuo ZHANG Xuanwen ZENG Xiaomin WU Guoju WANG Wenzhi QIN Dahe 《Journal of Arid Land》 SCIE CSCD 2018年第6期864-876,共13页
Stable isotopes in tree-ring cellulose provide important data in ecological,archaeological,and paleoenvironmental researches,thereby,the demand for stable isotope analyses is increasing rapidly.Simultaneous measuremen... Stable isotopes in tree-ring cellulose provide important data in ecological,archaeological,and paleoenvironmental researches,thereby,the demand for stable isotope analyses is increasing rapidly.Simultaneous measurement of cellulose δC and δO values from tree rings would reduce the cost of isotopic commodities and improve the analytical efficiency compared with conventional separate measurement.In this study,we compared the δC and δO values of tree-ringα-cellulose from Tianshan spruce(Picea schrenkiana)in an arid site in the drainage basin of the Urumqi River in Xinjiang of northwestern China based on separate and simultaneous measurements,using the combustion method(at1050°C)and the high-temperature pyrolysis method(at 1350°C and 1400°C).We verified the results of simultaneous measurement using the outputs from separate measurement and found that both methods(separate and simultaneous)produced similar δC values.The two-point calibrated method improved the results(range and variation)of δC and δO values.The mean values,standard deviations,and trends of the tree-ring δC obtained by the combustion method were similar to those by the pyrolysis method followed by two-point calibration.The simultaneously measured δO from the pyrolysis method at 1400°C had a nearly constant offset with that the pyrolysis method at 1350°C due to isotopic-dependence on the reaction temperature.However,they showed similar variations in the time series.The climate responses inferred from simultaneously and separately measured δC and δO did not differ between the two methods.The tree-ring δC and δO values were negatively correlated with standardized precipitation evapotranspiration index from May to August.In addition,the δO was significantly correlated with temperature(positive),precipitation(negative),and relative humidity(negative)from May to August.The tree-ring δC and δO values determined simultaneously through the high-temperature pyrolysis method could produce acceptable and reliable stable isotope series.The simultaneous isotopic measurement can greatly reduce the cost and time requirement compared with the separate isotopic measurement.These results are consistent with the previous studies at humid sites,suggesting that the simultaneous determination of δC and δO in tree-ringα-cellulose can be used in wide regions. 展开更多
关键词 tree rings stable carbon and oxygen isotopes COMBUSTION PYROLYSIS simultaneous determination CALIBRATION Picea schrenkiana
下载PDF
A Novel Sample Introduction Technique for the Simultaneous Determination of As,Se,Ge and Hg in Chinese Medicinal Material 被引量:1
8
《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2001年第4期400-406,共7页
A novel technique of Moveable Reduction Bed Hydride Generator(MRBHG)was applied tohe hydride generation or cold vapor generation of As,Se,Ge,and Hg existing In TraditionalChinese Medicinal Material(TCM).The si... A novel technique of Moveable Reduction Bed Hydride Generator(MRBHG)was applied tohe hydride generation or cold vapor generation of As,Se,Ge,and Hg existing In TraditionalChinese Medicinal Material(TCM).The simultaneous determination of the multi-elements wasperformed with ICP-MS.A solid reduction system involving the use of potassiumtetraborohydride and tartaric acid was applied to generating metal hydride or cold vaporefficiently.The factors affecting the metal cold vapor generation were studied.The mainadvantage of the technique is that only a 4μL volume of sample was required for the cold vapor 展开更多
关键词 for the Simultaneous Determination of As Se Ge A Novel Sample Introduction Technique CHINESE MATERIAL MEDICINAL and HG Ge
下载PDF
Simultaneous determination of borneol and its metabolite in rat plasma by GC-MS and its application to pharmacokinetic study 被引量:1
9
作者 Xiu-Man Sun Qiong-Feng Liao +2 位作者 Yu-Ting Zhou Xue-Jiao Deng Zhi-Yong Xie 《Journal of Pharmaceutical Analysis》 SCIE CAS 2014年第5期345-350,共6页
A gas chromatography mass spectrometry (GC-MS) method has been developed and fully validated for the simultaneous determination of natural borneol (NB) and its metabolite, camphor, in rat plasma. Following a singl... A gas chromatography mass spectrometry (GC-MS) method has been developed and fully validated for the simultaneous determination of natural borneol (NB) and its metabolite, camphor, in rat plasma. Following a single liquid-liquid extraction, the analytes were separated using an HP-5MS capillary column (0.25 mm ? 30 m ? 0.25μm) and analyzed by MS in the selected ion monitoring mode. Selected ion monitor (m/z) of borneol, camphor and internal standard was 95, 95 and 128, respectively. Linearity, accuracy, precision and extraction recovery of the analytes were all satisfactory. The method was successfully applied to pharmacokinetic studies of NB after oral administration to Wistar rats. 展开更多
关键词 Borneol Camphor Simultaneous determination Phannacokinetics GC-MS
下载PDF
Simultaneous colorimetric determination of morphine and ibuprofen based on the aggregation of gold nanoparticles using partial least square 被引量:1
10
作者 Morteza Bahram Tayyebeh Madrakian Sakineh Alizadeh 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2017年第6期411-416,共6页
In this work a new method is presented for simultaneous colorimetric determination of morphine (MOR) and ibuprofen (IBU) based on the aggregation of citrate-capped gold nanoparticles (AuNPs). Citrate-capped AuNP... In this work a new method is presented for simultaneous colorimetric determination of morphine (MOR) and ibuprofen (IBU) based on the aggregation of citrate-capped gold nanoparticles (AuNPs). Citrate-capped AuNPs were aggregated in the presence of MOR and IBU. The difference in kinetics of AuNPs aggregation in the presence of MOR/IBU was used for simultaneous analysis of MOR and IBU. The formation and size of synthesized AuNPs and the aggregated forms were monitored by infra-red (IR) spectroscopy and transmission electron microscopy (TEM), respectively. By adding MOR or IBU the absorbance was decreased at 520 nm and increased at 620 nm. The difference in kinetic profiles of aggregation was applied for simultaneous analysis of MOR and IBU using partial least square (PLS) regression as an efficient multivariate calibration method. The number of PLS latent variables was optimized by leave-one-out cross-validation method using predicted residual error sum of square. The proposed model exhibited a high capability in simultaneous prediction of MOR and IBU concentrations in real samples. The results showed linear ranges of 1.33-33.29 μg/mL (R2=0.9904) and 0.28-6.9 μg/mL (R2=0.9902) for MOR and IBU respectively with low detection limits of 0.15 and 0.03 μg/mL(S/N=5). 展开更多
关键词 Morphine Ibuprofen Simultaneous determination AuNPs Partial least squares
下载PDF
Electrochemically Reduced Graphene Oxide as Modified Electrode Material for Determination of Dihydroxybenzenes 被引量:1
11
作者 王梦梦 李曦 +4 位作者 LIU Jing XU Wenjing DONG Yulin LIU Peng 张超灿 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2017年第5期1220-1224,共5页
A simple and green method was introduced to fabricate the electrochemical sensor based on the electrochemically reduced graphene oxide(ERGO) modified electrode. It was found that the ERGO modified electrode exhibite... A simple and green method was introduced to fabricate the electrochemical sensor based on the electrochemically reduced graphene oxide(ERGO) modified electrode. It was found that the ERGO modified electrode exhibited an excellent catalytic activity toward the oxidation of dihydroxybenzenes isomers. Under the optimum conditions, in the simultaneous determination of the dihydroxybenzene isomers, the currents were linear with the concentrations of the isomers from 5 to 550 μmol/L for hydroquinone(HQ), from 6 to 400 μmol/L for catechol(CT) and from 5 to 350 μmol/L for resorcinol(RS), respectively. In addition, the proposed sensor has good stability and reproducibility. The developed method has been applied to the simultaneous determination of dihydroxybenzene isomers in real samples with a satisfactory recovery from 98% to 103%. 展开更多
关键词 graphene electrochemical reduction dihydroxybenzene simultaneous determination
下载PDF
Square wave voltammetric quantification of folic acid,uric acid and ascorbic acid in biological matrix 被引量:1
12
作者 Majid Arvand Akram Pourhabib Masoud Giahi 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2017年第2期110-117,共8页
Nowadays, modified electrodes with metal nanoparticles have appeared as an alternative for the electroanalysis of various compounds. In this study, gold nanoparticles(GNPs) were chosen as interesting metal nanoparti... Nowadays, modified electrodes with metal nanoparticles have appeared as an alternative for the electroanalysis of various compounds. In this study, gold nanoparticles(GNPs) were chosen as interesting metal nanoparticles for modifying carbon paste electrode(CPE). GNPs and the gold nanoparticles-modified carbon paste electrode(GNPs/CPE) were characterized by UV–Vis spectroscopy, transmission electron microscopy(TEM) and scanning electron microscopy(SEM). GNPs/CPE as a simple and sensitive electrode was used to study three important biological molecules: folic acid(FA), uric acid(UA) and ascorbic acid(AA). Square wave voltammetry(SWV) was used as an accurate technique for quantitative measurements. A good linear relation was observed between anodic peak current(ipa) and FA(5.2 × 10(-6)– 2.5 × 10(-5)M), UA(1.2 × 10(-6)– 2.1 × 10(-5)M) and AA(1.2 × 10(-6)– 2.5 × 10(-5)M) concentrations in simultaneous determination of these molecules. 展开更多
关键词 Ascorbic acid Folic acid gold nanoparticles-modified carbon paste electrode Simultaneous determination Uric acid
下载PDF
New Time-resolved-Tween 80 Chemiluminescent System for Simultaneous Determination of Trace Gold and Osmium
13
作者 韩鹤友 罗庆尧 余席茂 《Rare Metals》 SCIE EI CAS CSCD 1997年第3期35-40,共6页
A time resolved chemiluminescent analysis for simultaneous determination of trace Au(Ⅲ) and Os(Ⅳ) was proposed. The method is based on the kinetic distinction of Au(Ⅲ) and Os(Ⅳ) in Tween 80 KOH chemilumescent sy... A time resolved chemiluminescent analysis for simultaneous determination of trace Au(Ⅲ) and Os(Ⅳ) was proposed. The method is based on the kinetic distinction of Au(Ⅲ) and Os(Ⅳ) in Tween 80 KOH chemilumescent system. The detection limits were 1.1×10 -9 g/ml for Au(Ⅲ) and 1.0×10 -8 g/ml for Os(Ⅳ), with the linear ranges of 1.0×10 -8 ~1.0×10 -5 g/ml for Au(Ⅲ) and 1.0×10 -7 ~1.0×10 -6 g/ml for Os(Ⅳ). The method was applied to the determination of Au(Ⅲ) and Os(Ⅳ) in the sample of metallurgical materials of noble metals with satisfactory results. 展开更多
关键词 Time resolved CHEMILUMINESCENCE Tween80 Simultaneous determination GOLD OSMIUM
下载PDF
Simultaneous Determination of Uranium and Thorium with Standard Dual-addition Method
14
作者 何荣桓 王建华 王玉宝 《Rare Metals》 SCIE EI CAS CSCD 1998年第2期75-80,共6页
dual-standard addition method was proposed and the principle of simultaneous determination for a interfering binary mixtures was discussed. The proposed procedure was applied to spectroscopic analyses for the simultan... dual-standard addition method was proposed and the principle of simultaneous determination for a interfering binary mixtures was discussed. The proposed procedure was applied to spectroscopic analyses for the simultaneous determination of uranium and thorium without prior separation. Various molar ratios of uranium/thorium, from 0.5∶1 to 10∶1, can be determined with satisfactory precision and accuracy. Uranium and thorium content in a phosphate ore and simulated sample were determined, the recoveries were 98.4%~102.5% for uranium and 96.8%~102.3% for thorium, the relative standard deviations (R.S.D) were 1.5%~2.3% for uranium and 2.1%~3.1% for thorium. 展开更多
关键词 Dual-standard addition method Simultaneous determination URANIUM THORIUM Spectroscopic analysis
下载PDF
Simultaneous Spectrophotometric Determination of Four Components including Acetaminophen by Taget Factor Analysis
15
作者 张立庆 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2007年第3期569-571,共3页
UV Spectrophotometric Target Factor Analysis (TFA) was used for the simultaneous determination of four components (acetaminophen, guuaifenesin, caffeine, Chlorphenamine maleate) in cough syrup. The computer Frogra... UV Spectrophotometric Target Factor Analysis (TFA) was used for the simultaneous determination of four components (acetaminophen, guuaifenesin, caffeine, Chlorphenamine maleate) in cough syrup. The computer Frogram of TFA is based on VC++ language. The difficulty of overlapping of absorption spectra of four compounds was overcome by this procedure. The experimental results show that the average recovery of each component is all in the range from 98.9% to 106.8% and each component obtains satisfactory results without any pre-separation. 展开更多
关键词 ACETAMINOPHEN taget factor analysis SPECTROPHOTOMETRY four-component simultaneous determination
下载PDF
Investigati on sonsimultaneous determination of silver and mercury in catalytic-ligandsub stitution reaction with stopped-flow technique calibrated by synergistic effect
16
作者 Wang Jianhua , He Ronghuan(Chemistry Department of Yantai Normal College, Yantai 264025 , China) 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1995年第4期414-421,共8页
Investigationsonsimultaneousdeterminationofsilverandmercuryincatalytic-ligandsubstitutionreactionwithstopped... Investigationsonsimultaneousdeterminationofsilverandmercuryincatalytic-ligandsubstitutionreactionwithstopped-flowtechniquecal... 展开更多
关键词 kinetic stopped FIA synergistic catalytic coefficient simultaneous determination mercury(II) silver(I).
下载PDF
SIMULTANEOUS DETERMINATION OF EPHEDRINE AND ITS ANALOGUES IN URINE BY CAPILLARY GAS CHROMATOGRAPHY
17
作者 Lin LI Jian Fang CUI Kai Rong CUI Yi ZHOU Mu Zou WANG Tong Hui ZHOU (Institute of Materia Medica,Chinese Academy of Medical Sciences,Beijing 100050) 《Chinese Chemical Letters》 SCIE CAS CSCD 1990年第2期175-178,共4页
A method is developed for the simultaneous determination of ephedrine,pseudoephedrine, norephedrine, norpseudoephedrine and methylephedrine in urine on a capillary column using nitrogen-phosphorus detector.Diphenylami... A method is developed for the simultaneous determination of ephedrine,pseudoephedrine, norephedrine, norpseudoephedrine and methylephedrine in urine on a capillary column using nitrogen-phosphorus detector.Diphenylamine is used as the internal standard.Calibration graphs are linear down to 1.30ug/ml urine. 展开更多
关键词 GAS IV SIMULTANEOUS DETERMINATION OF EPHEDRINE AND ITS ANALOGUES IN URINE BY CAPILLARY GAS CHROMATOGRAPHY ITS
下载PDF
Kinetic Investigation of Ce,Y-CPAmA Systems and Simultaneous Determination of Sc,Y,Ce via Complementary Tristimulus Spectrophotometry
18
作者 成荣明 赵泓 卓宗亮 《Journal of Rare Earths》 SCIE EI CAS CSCD 1992年第3期227-230,共4页
In the past ten years the eomplementary tristimulus speetrophotometryll],eTs,has seen its diverse appli-eations{2一61 though most researehes remain in relatively simpe systems,and less work has been involvinkinetie re... In the past ten years the eomplementary tristimulus speetrophotometryll],eTs,has seen its diverse appli-eations{2一61 though most researehes remain in relatively simpe systems,and less work has been involvinkinetie reaetions. An attemPt has been made on the investigation of some comPlieated systems eontainingrare earths and meta一acetylchloroPhosPhonaz 展开更多
关键词 Complementary tristimulus spectrophotometry Kinetic characteristics Simultaneous determination Rare earth
下载PDF
The Simultaneous Determination of Cu Ph Cd and Sb by Derivative Adsorption Chronopotentiometry
19
作者 Xiao Li ZHANG Shu Ying PAN Department of Chemistry Shandong University, Jinan 250100 《Chinese Chemical Letters》 SCIE CAS CSCD 2000年第9期807-808,共2页
The behaviour of the complexes of copper,lead,cadmium and antimony with salicylfluorone (SAF) adsorbed on HMDE has been investigated by derivative chronopotentiometry in NH_3/NH_4C1. The dependence of the peak height... The behaviour of the complexes of copper,lead,cadmium and antimony with salicylfluorone (SAF) adsorbed on HMDE has been investigated by derivative chronopotentiometry in NH_3/NH_4C1. The dependence of the peak height on the dt/dE vs E curve on preconcentration time, the pH of solution and the constant reducing current are discussed. This method achieved the simultaneous determination of copper, lead, cadmium and antimony in human hair. 展开更多
关键词 Simultaneous determination Cu Pb Cd Sb complex chronopotentiometry.
下载PDF
SIMULTANEOUS DETERMINATION OF VITAMIN B COMPLEX (THIAMINE, RIBOFLAVIN, NIACIN, PYRIDOXINE AND FOLIC ACID) IN FOODS BY HPLC
20
作者 Ya Shan HAN Xiao Qing SONG +1 位作者 Jin Cheng ZHAO Yun Qing DAI 《Chinese Chemical Letters》 SCIE CAS CSCD 1991年第8期645-648,共4页
A high performance liquid chromatographic assay has been developed for the simultaneous determination of five water soluble vitamins:thimine, riboflavin, niacin, pyridoxine and folic acid in cereal products and fresh ... A high performance liquid chromatographic assay has been developed for the simultaneous determination of five water soluble vitamins:thimine, riboflavin, niacin, pyridoxine and folic acid in cereal products and fresh vegetables. Food samples were hydrolyzed in 0.4 mol/L HCl, autoclaved at 120℃ 15 psi for 20 minutes, using a μ-Bondapak column (3.9×300mm, Waters Co.), a mobile phase of methanol-water (30:70) (0.005 mol/L heptanesulfonic acid) and a flow rate of 1.0 ml/min gave the most satisfactory separation of the five water soluble vitamins. A double channel deteetion was used: four vitamins (B_5, folic acid, B_2, B_1) were detected hy UV spectrophotometry (254 nm) first, pyridoxine (B_6) was detected by fluoromelry (EX 290nm, EM 395 nm) afterwards. Detection limits were 2, 5, 5, 2and 5ng, linear ranges were 5-10ng, 5-50ng, 5-40ng, 5-50ng and 10-50ng for B_1, B_2, B_5, B_6 and folic acid respectively. Recoveries were 92-100%(B_5), 51-52% (folio acid), 103—105% (B_2), 99—100% (B_6) and 91.3—102% (B_1) respectively. In comparison with a reference method and checking with food composition tables, very satisfactory results were obtained by this method. 展开更多
关键词 PYRIDOXINE AND FOLIC ACID NIACIN RIBOFLAVIN SIMULTANEOUS DETERMINATION OF VITAMIN B COMPLEX THIAMINE IN FOODS BY HPLC
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部