Objective To compare the cupric ion releasing in vitro o.f the three IUDs. Methods The stability o.f cupric ion releasing o.f IUDs including TCu 380.4 IUD (TCu 380A), Multiload Cu375 IUD (MCu 375) and Yuangong 365...Objective To compare the cupric ion releasing in vitro o.f the three IUDs. Methods The stability o.f cupric ion releasing o.f IUDs including TCu 380.4 IUD (TCu 380A), Multiload Cu375 IUD (MCu 375) and Yuangong 365 copper-bearing indomethacin-releasing IUD (Yuangong 365) by the determination of cupric ion releasing in simulated uterine fluid. The simulated uterine fluid was used for releasing media. Copper ion was determined by flame atomic absorption spectrometer. Results The cupric ion releasing of three IUDs were instable at the beginning and tend to be stable gradually. In the stable phase, the average level of cupric ion releasing of TCu380A, MCu375 and Yuangong 365 were 4.25±2.71-7.62±6.42 μg, 4.92±1.23 -8.62±3.08 μg and 2.19±0.40-4.68±1.66 μg, respectively. TCu380A had higher instable releasing level than those of Yuangong 365 (P〈0. 05). Conclusion TCu 380.4 and MCu 375 showed a "burst release" during the first few days and the.former was of great significance(P〈0.05). The initial cupric ion releasing of Yuangong 365 appeared to be the lowest, followed by MCu375 and TCu380A in a releasing order展开更多
Radiative imaging of combustion flame in furnace of power plant plays an increasingly important role in combustion diagnosis. This paper presents a new method for calculating the radiative imaging of three-dimensional...Radiative imaging of combustion flame in furnace of power plant plays an increasingly important role in combustion diagnosis. This paper presents a new method for calculating the radiative imaging of three-dimensional (3D) combustion flame based on Monte Carlo method and optical lens imaging. Numerical simulation case was used in this study. Radiative images were calculated and images obtained can not only present the energy distribution on the charge-coupled device (CCD) camera target plane but also reflect the energy distribution condition in the simulation furnace. Finally the relationships between volume ele- ments and energy shares were also discussed.展开更多
基金This study was supported by National Key Scientific and Technological Project(2004BA720A32)
文摘Objective To compare the cupric ion releasing in vitro o.f the three IUDs. Methods The stability o.f cupric ion releasing o.f IUDs including TCu 380.4 IUD (TCu 380A), Multiload Cu375 IUD (MCu 375) and Yuangong 365 copper-bearing indomethacin-releasing IUD (Yuangong 365) by the determination of cupric ion releasing in simulated uterine fluid. The simulated uterine fluid was used for releasing media. Copper ion was determined by flame atomic absorption spectrometer. Results The cupric ion releasing of three IUDs were instable at the beginning and tend to be stable gradually. In the stable phase, the average level of cupric ion releasing of TCu380A, MCu375 and Yuangong 365 were 4.25±2.71-7.62±6.42 μg, 4.92±1.23 -8.62±3.08 μg and 2.19±0.40-4.68±1.66 μg, respectively. TCu380A had higher instable releasing level than those of Yuangong 365 (P〈0. 05). Conclusion TCu 380.4 and MCu 375 showed a "burst release" during the first few days and the.former was of great significance(P〈0.05). The initial cupric ion releasing of Yuangong 365 appeared to be the lowest, followed by MCu375 and TCu380A in a releasing order
基金Project supported by National Natural Science Foundation of China(No. 60534030)Program for Changjiang Scholars and InnovativeResearch Team in University (No. IRT0434)
文摘Radiative imaging of combustion flame in furnace of power plant plays an increasingly important role in combustion diagnosis. This paper presents a new method for calculating the radiative imaging of three-dimensional (3D) combustion flame based on Monte Carlo method and optical lens imaging. Numerical simulation case was used in this study. Radiative images were calculated and images obtained can not only present the energy distribution on the charge-coupled device (CCD) camera target plane but also reflect the energy distribution condition in the simulation furnace. Finally the relationships between volume ele- ments and energy shares were also discussed.