期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
DESIGN OF NEW TYPE EXTERNAL COUNTER-PULSATION DEVICE
1
《Chinese Journal of Biomedical Engineering(English Edition)》 1999年第4期91-91,共1页
关键词 DESIGN OF NEW TYPE EXTERNAL COUNTER-PULSATION device
下载PDF
Suppression of extension of the photo-sensitive area for a planar-type front-illuminated InGaAs detector by the LBIC technique 被引量:1
2
作者 李永富 唐恒敬 +5 位作者 李淘 朱耀明 姜佩璐 乔辉 李雪 龚海梅 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2010年第1期17-21,共5页
To suppress the extension of the photo-sensitive area of a planar-type InGaAs detector, the structure of the detector was modified, and the small-diffusion-area diffusion method, circle-type covering contact and guard... To suppress the extension of the photo-sensitive area of a planar-type InGaAs detector, the structure of the detector was modified, and the small-diffusion-area diffusion method, circle-type covering contact and guard-ring were introduced. The laser-beam-induced-current (LBIC) technique was used to study the photo responsive characteristics of the photo-sensitive area of different detector structures. It was indicated that, by modifying the size of the diffusion area, the width of the circle-type covering contact, the distance between the guard-ring and the photo-sensitive area and the working status of the guard-ring, extension of the photo-sensitive area could be effectively suppressed, and the detector photo-sensitive area could be exactly defined. 展开更多
关键词 InGaAs photodiode LBIC planar type device photo-sensitive area
原文传递
Congestion mitigation on high voltage power lines using multiple TCSC & UPFC
3
作者 Anwar S.Siddiqui Tanmoy Deb 《International Journal of Modeling, Simulation, and Scientific Computing》 EI 2015年第2期198-212,共15页
With severe overload on transmission lines,further exchange of power flow is affected due to congestion on power transmission lines.This paper investigates the effect of Flexible AC Transmission System(FACTS)devices l... With severe overload on transmission lines,further exchange of power flow is affected due to congestion on power transmission lines.This paper investigates the effect of Flexible AC Transmission System(FACTS)devices like TCSC and UPFC in congestion mitigation.The proposal uses multiple FACTS devices of similar type and investigates their effect on congestion mitigation in high voltage transmission lines.This proposal is tested on IEEE-14 bus system. 展开更多
关键词 CONGESTION multiple FACTS devices of similar type TCSC UPFC
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部