期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
A consistency improving method in the analytic hierarchy process based on directed circuit analysis 被引量:2
1
作者 WU Shihui LIU Xiaodong +1 位作者 LI Zhengxin ZHOU Yu 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2019年第6期1160-1181,共22页
Test of consistency is critical for the analytic hierarchy process(AHP) methodology. When a pairwise comparison matrix(PCM) fails the consistency test, the decision maker(DM) needs to make revisions. The state of the ... Test of consistency is critical for the analytic hierarchy process(AHP) methodology. When a pairwise comparison matrix(PCM) fails the consistency test, the decision maker(DM) needs to make revisions. The state of the art focuses on changing a single entry or creating a new matrix based on the original inconsistent matrix so that the modified matrix can satisfy the consistency requirement. However, we have noticed that the reason that causes inconsistency is not only numerical inconsistency, but also logical inconsistency, which may play a more important role in the whole inconsistency. Therefore, to realize satisfactory consistency, first of all, we should change some entries that form a directed circuit to make the matrix logically consistent, and then adjust other entries within acceptable deviations to make the matrix numerically consistent while preserving most of the original comparison information. In this paper, we firstly present some definitions and theories, based on which two effective methods are provided to identify directed circuits. Four optimization models are proposed to adjust the original inconsistent matrix. Finally, illustrative examples and comparison studies show the effectiveness and feasibility of our method. 展开更多
关键词 analytic hierarchy process(AHP) pairwise compari son matrix(PCM) logical inconsistency numerical inconsistency directed circuit.
下载PDF
Direct Current Circuit Breaker in EAST
2
作者 宋执权 傅鹏 《Plasma Science and Technology》 SCIE EI CAS CSCD 2006年第4期481-484,共4页
This paper introduces the configuration and the operation principles of a high power direct current circuit breaker (DCCB). The commutating current principle of the breaker is described in details with its theory an... This paper introduces the configuration and the operation principles of a high power direct current circuit breaker (DCCB). The commutating current principle of the breaker is described in details with its theory and simulation analysis. The test results presented show that the DCCB meets the requirements for quenching protection. It will be used as the main breaker for quench protection in EAST. 展开更多
关键词 direct current circuit breaker insulator recovery time commutating current contact
下载PDF
Joint Limiting Control Strategy Based on Virtual Impedance Shaping for Suppressing DC Fault Current and Arm Current in MMC-HVDC Systems 被引量:1
3
作者 Qin Jiang Yan Tao +4 位作者 Baohong Li Tianqi Liu Zhe Chen Frede Blaabjerg Peng Wang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第6期2003-2014,共12页
This paper proposes a joint limiting control strategy for suppressing DC fault current and arm current in modular multilevel converter-based high-voltage direct current(MMC-HVDC) systems, which includes two target-ori... This paper proposes a joint limiting control strategy for suppressing DC fault current and arm current in modular multilevel converter-based high-voltage direct current(MMC-HVDC) systems, which includes two target-oriented current limiting controls. To limit the DC fault current in the early fault stage, an equivalent modular multilevel converter(MMC) impedance is obtained, and its high-frequency part is reshaped by introducing virtual impedance, which is realized by adjusting the inserted submodules adaptively. Following the analysis of MMC control characteristics, the arm current limiting strategy is investigated, with results showing that the inner-loop control has significant effects on arm current and that a simple low-pass filter can reduce the arm current in the fault period. Finally, by combining the virtual impedance shaping and innerloop control, the fault currents of DC lines and MMC arms can be suppressed simultaneously, which can not only alleviate the interrupting pressure of the DC circuit breaker, but also prevent the MMC from being blocked by the arm overcurrent. Theoretical analysis conclusions and the proposed strategy are verified offline by a digital time-domain simulation on Power Systems Computer Aided Design/Electromagnetic Transients including DC platform, and experiment on a real-time digital simulator platform. 展开更多
关键词 Modular multilevel converter(MMC) highvoltage direct current(HVDC)transmission direct current fault fault current limitation arm current suppression virtual impedance direct current circuit breaker
原文传递
Modular Reciprocating HVDC Circuit Breaker with Current-limiting and Bi-directional Series-parallel Branch Switching Capability 被引量:5
4
作者 Jianzhong Xu Moke Feng Chengyong Zhao 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2020年第4期778-786,共9页
The high-voltage direct current(HVDC)circuit breaker is becoming popular with the rapid development of the flexible HVDC grid for efficient DC fault ride-through purposes.This paper proposes a novel module for recipro... The high-voltage direct current(HVDC)circuit breaker is becoming popular with the rapid development of the flexible HVDC grid for efficient DC fault ride-through purposes.This paper proposes a novel module for reciprocating HVDC circuit breaker topology,whose branch connections are able to switch between series and parallel modes to limit the rising rate and interrupt the DC fault currents.Diode-bridge submodules(DBSMs)are used to compose the main branch for current interruption.Besides fault clearance,the proposed topology has the advantageous function of DC fault current limiting by employing DBSMs with bi-directional conduction capability.The topology can easily switch among branch connection modes through the assembled trans-valves,and their resistance and reactance are very small in the normal state when branches are in parallel and the values become promptly large in the transient state when the branches are series connected.With the modular design,it is easy to change the number of branches or sub-modules and the types of sub-modules to adapt to more specific needs.A 6-terminal modular multi-level converter(MMC)based HVDC grid is established in PSCAD/EMTDC,and various simulation scenarios are carried out to validate the proposed topology. 展开更多
关键词 Reciprocating current limiting direct current circuit breaker(DCCB) diode-bridge sub-module(DBSM) series and parallel branches DC fault clearance
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部