期刊文献+
共找到14篇文章
< 1 >
每页显示 20 50 100
Cascade Kalman filter for gravity anomaly distortion correction based on second order potential model 被引量:1
1
作者 赵立业 李宏生 +1 位作者 周百令 李坤宇 《Journal of Southeast University(English Edition)》 EI CAS 2008年第4期482-486,共5页
Using a gravity anomaly covariance function based on the second-order Ganssian Markov gravity anomaly potential model, the state equation of a gravity anomaly signal is obtained in marine gravimetry. Combined with the... Using a gravity anomaly covariance function based on the second-order Ganssian Markov gravity anomaly potential model, the state equation of a gravity anomaly signal is obtained in marine gravimetry. Combined with the system state equation and the measurement equation, a new method of the cascade Kalman filter is proposed and applied to the correction of gravity anomaly distortion. In the signal processing procedure, an inverse Kalman filter is used to restore the gravity anomaly signal and high frequency noises first. Then an adaptive Kalman filter, which uses the gravity anomaly state equation as the system equation, is set to estimate the actual gravity anomaly data. Emulations and experiments indicate that both the cascade Kalman filter method and the single inverse Kalman filter method are effective in alleviating the distortion of the gravity anomaly signal, but the performance of the cascade Kalman filter method is better than that of the single inverse Kalman filter method. 展开更多
关键词 GRAVIMETER gravity anomaly cascade Kalman filter inverse Kalman filter distortion correction
下载PDF
X-ray image distortion correction based on SVR
2
作者 袁泽慧 李世中 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2015年第3期302-306,共5页
X-ray image has been widely used in many fields such as medical diagnosis,industrial inspection,and so on.Unfortunately,due to the physical characteristics of X-ray and imaging system,distortion of the projected image... X-ray image has been widely used in many fields such as medical diagnosis,industrial inspection,and so on.Unfortunately,due to the physical characteristics of X-ray and imaging system,distortion of the projected image will happen,which restrict the application of X-ray image,especially in high accuracy fields.Distortion correction can be performed using algorithms that can be classified as global or local according to the method used,both having specific advantages and disadvantages.In this paper,a new global method based on support vector regression(SVR)machine for distortion correction is proposed.In order to test the presented method,a calibration phantom is specially designed for this purpose.A comparison of the proposed method with the traditional global distortion correction techniques is performed.The experimental results show that the proposed correction method performs better than the traditional global one. 展开更多
关键词 X-ray image distortion correction support vector regression machine
下载PDF
Straight line feature based image distortion correction 被引量:1
3
作者 Zhang Haofeng Zhao Chunxia Lu Jianfeng Tang Zhenmin Yang Jingyu 《Engineering Sciences》 EI 2008年第2期83-86,96,共5页
An image distortion correction method is proposed, which uses the straight line features. Many parallel lines of different direction from different images were extracted, and then were used to optimize the distortion ... An image distortion correction method is proposed, which uses the straight line features. Many parallel lines of different direction from different images were extracted, and then were used to optimize the distortion parameters by nonlinear least square. The thought of step by step was added when the optimization method working. 3D world coordination is not need to know, and the method is easy to implement. The experiment result shows its high accuracy. 展开更多
关键词 distortion correction straight line feature nonlinear least square multi-step optimization
下载PDF
Stick-slip nonuniform rotation distortion correction in distal scanning optical coherence tomography catheters
4
作者 Jessica Mavadia-Shukla Jianlin Zhang +1 位作者 Kaiyan Li Xingde Li 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2020年第6期94-101,共8页
We present a robust and fiducial-marker-free algorithm that can identify and correct stick-slip distortion caused by nonuniform rotation(or beam scanning)in distally scanned catheters for endoscopic optical coherence ... We present a robust and fiducial-marker-free algorithm that can identify and correct stick-slip distortion caused by nonuniform rotation(or beam scanning)in distally scanned catheters for endoscopic optical coherence tomography(OCT)images.This algorithm employs spatial fre-quency analysis to select and remove distortions.We demonstrate the feasibility of this algorithm on images acquired from ex vivo rat colon with a distally scanned DC motor-based endoscope.The proposed algorithm can be applied to general endoscopic OCT images for correcting non-uniform rotation distortion. 展开更多
关键词 Optical coherence tomography nonuniform rotation distortion correction ENDOSCOPE distal-scanning
下载PDF
Lens distortion correction based on one chessboard pattern image 被引量:3
5
作者 Yubin WU Shixiong JIANG Zhenkun XU Song ZHU Danhua CAO 《Frontiers of Optoelectronics》 CSCD 2015年第3期319-328,共10页
This paper proposes a detection method of chessboard comer to correct camera distortions -including radial distortion, decentering distortion and prism distor- tion. This proposed method could achieve high comer detec... This paper proposes a detection method of chessboard comer to correct camera distortions -including radial distortion, decentering distortion and prism distor- tion. This proposed method could achieve high comer detection rate. Then we used iterative procedure to optimize distortion parameter to minimize distortion residual. In this method, first, non-distortion points are evaluated by four points near image center; secondly, Levenberg-Marquardt nonlinear optimization algorithm was adopted to calculate distortion parameters, and then to correct image by these parameters; thirdly, we calculated comer points on the corrected image, and repeated previous two steps until distortion parameters converge. Results showed the proposed method by iterative procedure can make the impact of slight distortion around image center negligible and the average of distortion residual of one line is almost 0.3 pixels. 展开更多
关键词 computer vision camera distortion distortion correction comer detection
原文传递
Correction Optimization of Lens Radial Distortion with Bending Measurement Function
6
作者 张敏 吴凡路 +3 位作者 金龙旭 李国宁 韩双丽 张宇 《Transactions of Tianjin University》 EI CAS 2016年第4期374-379,共6页
In this paper, a distortion correction method with reduced complexity is proposed. With the singleparameter division model, the initial approximation of distortion parameters and the distortion center can be calibrate... In this paper, a distortion correction method with reduced complexity is proposed. With the singleparameter division model, the initial approximation of distortion parameters and the distortion center can be calibrated. Based on the distance from the image center to the fitting lines of the extracted curves, a bending measurement function with a weighted factor is proposed to optimize the initial value. Simulation and experiments verify the proposed method. 展开更多
关键词 arc fitting camera calibration distortion correction division model field angle
下载PDF
Distortion correction for the elemental images of integral imaging by introducing the directional diffuser
7
作者 Xunbo Yu Xinzhu Sang +5 位作者 Xin Gao Shenwu Yang Boyang Liu Duo Chen Binbin Yan Chongxiu Yu 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第4期56-60,共5页
A distortion correction method for the elemental images of integral imaging(Ⅱ) by utilizing the directional diffuser is demonstrated. In the traditional Ⅱ, the distortion originating from lens aberration wraps ele... A distortion correction method for the elemental images of integral imaging(Ⅱ) by utilizing the directional diffuser is demonstrated. In the traditional Ⅱ, the distortion originating from lens aberration wraps elemental images and degrades the image quality severely. According to the theoretical analysis and experiments, it can be proved that the farther the three-dimensional image is displayed from the lens array, the more serious the distortion is. To analyze the process of eliminating lens distortion, one lens and its corresponding elemental image are separated from the traditional Ⅱ. By introducing the directional diffuser, the aperture stop of the separated optical system changes from the eye's pupil to the lens. In terms of contrast experiments, the distortion of the improved display system is corrected effectively. In the experiment, when the distance between the reconstructed image and lens array is equal to 120 mm, the largest lens distortion is decreased from 46.6% to 3.3%. 展开更多
关键词 distortion correction for the elemental images of integral imaging by introducing the directional diffuser
原文传递
Application of the Delaunay triangulation interpolation in distortion XRII image 被引量:2
8
作者 李元金 舒华忠 +3 位作者 罗立民 陈阳 王涛 岳座刚 《Journal of Southeast University(English Edition)》 EI CAS 2014年第3期306-310,共5页
To alleviate the distortion of XRII X-ray image intensifier images in the C-arm CT computer tomography imaging system an algorithm based on the Delaunay triangulation interpolation is proposed.First the causes of the ... To alleviate the distortion of XRII X-ray image intensifier images in the C-arm CT computer tomography imaging system an algorithm based on the Delaunay triangulation interpolation is proposed.First the causes of the phenomenon the classical correction algorithms and the Delaunay triangulation interpolation are analyzed.Then the algorithm procedure is explained using flow charts and illustrations. Finally experiments are described to demonstrate its effectiveness and feasibility. Experimental results demonstrate that the Delaunay triangulation interpolation can have the following effects.In the case of the same center the root mean square distances RMSD and standard deviation STD between the corrected image with Delaunay triangulation interpolation and the ideal image are 5.760 4 ×10 -14 and 5.354 2 ×10 -14 respectively.They increase to 1.790 3 2.388 8 2.338 8 and 1.262 0 1.268 1 1.202 6 after applying the quartic polynomial model L1 and model L2 to the distorted images respectively.The RMSDs and STDs between the corrected image with the Delaunay triangulation interpolation and the ideal image are 2.489 × 10 -13 and 2.449 8 ×10 -13 when their centers do not coincide. When the quartic polynomial model L1 and model L2 are applied to the distorted images they are 1.770 3 2.388 8 2.338 8 and 1.269 9 1.268 1 1.202 6 respectively. 展开更多
关键词 XRII image Delaunay triangulation interpolation distortion correction
下载PDF
Evaluation and extraction of weak gravity and magnetic anomalies 被引量:2
9
作者 刘云祥 《Applied Geophysics》 SCIE CSCD 2007年第4期288-293,共6页
In this paper, I introduce what are called weak gravity and magnetic anomalies and propose standards for estimating their reliability. I also introduce new techniques for processing this kind of weak anomaly. These te... In this paper, I introduce what are called weak gravity and magnetic anomalies and propose standards for estimating their reliability. I also introduce new techniques for processing this kind of weak anomaly. These techniques consist of interference elimination and weak signal extraction. Practical applications have proved their effectiveness, Weak gravity and magnetic anomalies will get more attention with the development of targeted exploration. 展开更多
关键词 gravity and magnetic exploration weak anomaly anomaly extraction less balance filtering distortion correction
下载PDF
Spatial weight matrix in dimensionality reduction reconstruction for microelectromechanical system-based photoacoustic microscopy 被引量:1
10
作者 Yuanzheng Ma Chang Lu +2 位作者 Kedi Xiong Wuyu Zhang Sihua Yang 《Visual Computing for Industry,Biomedicine,and Art》 2020年第1期247-256,共10页
A micro-electromechanical system(MEMS)scanning mirror accelerates the raster scanning of optical-resolution photoacoustic microscopy(OR-PAM).However,the nonlinear tilt angular-voltage characteristic of a MEMS mirror i... A micro-electromechanical system(MEMS)scanning mirror accelerates the raster scanning of optical-resolution photoacoustic microscopy(OR-PAM).However,the nonlinear tilt angular-voltage characteristic of a MEMS mirror introduces distortion into the maximum back-projection image.Moreover,the size of the airy disk,ultrasonic sensor properties,and thermal effects decrease the resolution.Thus,in this study,we proposed a spatial weight matrix(SWM)with a dimensionality reduction for image reconstruction.The three-layer SWM contains the invariable information of the system,which includes a spatial dependent distortion correction and 3D deconvolution.We employed an ordinal-valued Markov random field and the Harris Stephen algorithm,as well as a modified delay-and-sum method during a time reversal.The results from the experiments and a quantitative analysis demonstrate that images can be effectively reconstructed using an SWM;this is also true for severely distorted images.The index of the mutual information between the reference images and registered images was 70.33 times higher than the initial index,on average.Moreover,the peak signal-to-noise ratio was increased by 17.08%after 3D deconvolution.This accomplishment offers a practical approach to image reconstruction and a promising method to achieve a real-time distortion correction for MEMS-based OR-PAM. 展开更多
关键词 Photoacoustic microscopy Spatial weight matrix Dimensionality reduction distortion correction Mutual information
下载PDF
A corrected method of distorted printed circuit board image
11
作者 乔闹生 叶玉堂 黄永林 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第1期366-370,共5页
This paper proposes a corrected method of distorted image based on adaptive control. First, the adaptive control relationship of pixel point positions between distorted image and its corrected image is given by using ... This paper proposes a corrected method of distorted image based on adaptive control. First, the adaptive control relationship of pixel point positions between distorted image and its corrected image is given by using polynomial fitting, thus control point pairs between the distorted image and its corrected image are found. Secondly, the value of both image distortion centre and polynomial coefficient is obtained with least square method, thus the relationship of each control point pairs is deduced. In the course of distortion image processing, the gray value of the corrected image is changed into integer with bilinear interpolation. Finally, the experiments are performed to correct two distorted printed circuit board images. The results are perfect and the mean square errors of residual error are tiny. 展开更多
关键词 distortion correction adaptive control printed circuit board image mean square errorof residual error
下载PDF
BUNDLE ADJUSTMENTS CCD CAMERA CALIBRATION BASED ON COLLI NEARITY EQUATION 被引量:3
12
作者 LiuChangying YuZhijing CheRensheng YeDong HuangQingcheng YangDingning 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2004年第4期494-497,共4页
The solid template CCD camera calibration method of bundle adjustments basedon collinearity equation is presented considering the characteristics of space large-dimensionon-line measurement. In the method, a more comp... The solid template CCD camera calibration method of bundle adjustments basedon collinearity equation is presented considering the characteristics of space large-dimensionon-line measurement. In the method, a more comprehensive camera model is adopted which is based onthe pinhole model extended with distortions corrections. In the process of calibration, calibrationprecision is improved by imaging at different locations in the whole measurement space,multi-imaging at the same location and bundle adjustments optimization. The calibration experimentproves that the calibration method is able to fulfill calibration requirement of CCD camera appliedto vision measurement. 展开更多
关键词 Bundle adjustments distortions corrections Collinearity equation Cameracalibration
下载PDF
Correction of dispersion distortion of femtosecond pulses by using the non-planar surface of diffractive optical elements
13
作者 I.V.Minin O.V.Minin 《Chinese Optics Letters》 SCIE EI CAS CSCD 2004年第8期435-437,共3页
Peculiarities of propagation of femtosecond pulses through a focusing diffractive optical element (DOE) are considered. It is shown that the time delay between the pulse and phase wavefronts can be decreased by fabric... Peculiarities of propagation of femtosecond pulses through a focusing diffractive optical element (DOE) are considered. It is shown that the time delay between the pulse and phase wavefronts can be decreased by fabricating the DOE on the optimal curvilinear surface. 展开更多
关键词 correction of dispersion distortion of femtosecond pulses by using the non-planar surface of diffractive optical elements DOE
原文传递
Ray tracing particle image velocimetry-Challenges in the application to a packed bed 被引量:1
14
作者 Christin Velten Mirko Ebert +1 位作者 Christian Lessig Katharina Zahringer 《Particuology》 SCIE EI CAS CSCD 2024年第1期194-208,共15页
Ray tracing Particle Image Velocimetry(RT-PIV)is an optical technique for high resolution velocity measurements in challenging optical systems,such as transparent packed beds,that uses ray tracing to correct for disto... Ray tracing Particle Image Velocimetry(RT-PIV)is an optical technique for high resolution velocity measurements in challenging optical systems,such as transparent packed beds,that uses ray tracing to correct for distortions introduced by transparent geometries in the light paths.The ray tracing based correction is a post processing step applied to the raw PIV particle images before classical PIV evaluation.In this study,RT-PIV is performed in the top layer of a body centred cubic(bcc)sphere packing with gaseous flow,where optical access is obtained by the use of transparent N-BK7 glass balls with a diameter of d=40 mm.RT-PIV introduces new experimental and numerical challenges,for example a limited field of view,illumination difficulties,a very large required depth of field and high sensitivity to geometric parameters used in the ray tracing correction.These challenges and their implications are the main scope and discussed in the present work.Further,the validation of the ray tracing reconstruction step is presented and examples for the obtained corrected vector fields in a packed bed are given.The results show the strength of the method in reconstructing velocity fields behind transparent spheres that would not have been accessible by optical measurement techniques without the ray tracing correction. 展开更多
关键词 Ray tracing particle image velocimetry(RT-PIV) Transparent spherical particles Packed bed distortion correction Gas flow
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部