期刊文献+
共找到15篇文章
< 1 >
每页显示 20 50 100
Real-time Three-Dimensional Color Doppler Flow Imaging: An Improved Technique for Quantitative Analysis of Aortic Regurgitation 被引量:3
1
作者 吕清 刘夏天 +3 位作者 谢明星 王新房 王静 庄磊 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第1期148-152,共5页
The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT... The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r= 0.93, Y=0.89X+ 3.9, SEE= 8.6 mL, P〈0.001 ); the mean (SD) difference between the two methods was - 1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r=0.88, Y=0.71X+ 14.8, SEE= 6.4 %, P〈0. 001); the mean (SD) difference between the two methods was -1.2 (7.9) %. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF. 展开更多
关键词 real-time three-dimensional echocardiography color doppler flow imaging aortic regurgitation
下载PDF
Hemodynamic Changes on Color Doppler Flow Imaging and Intravenous Contrast-enhanced Ultrasound for Assessing Transplanted Liver and Early Diagnosis of Complications 被引量:1
2
作者 黄道中 陈云超 +1 位作者 李开艳 张青萍 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第3期284-286,共3页
The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discu... The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discussed. Seventy-five patients with orthotopic liver transplantation (OLT) underwent CDFI. The following parameters were measured: peak systolic velocity (PS), resistance index (RI) and Doppler perfusion index (DPI) of the hepatic artery (HA), time average velocity (TAV) of portal vein (PV) and velocity of hepatic vein (HV) in different stages postoperation, And 11 patients of them received CEUS. Thirty healthy subjects were enrolled as controls, The results showed that: (1) In 23 patients without obvious complications, TAV of PV within 15 days post-operation was significantly higher than in controls (P〈0.05), PS and DPI of HA within 7 days postoperation were lower, but RI was higher than in controls (P〈0.05); (2) When the hepatic artery thrombosis (HAT) occurred, PS and DPI of HA were obviously decreased, but TAV of PV significantly increased like a high saw-tooth wave; (3) While rejection occurred, both TAV of PV and PS of HA were decreased with the increase in RI of HA, and the triphasic wave of HV disappeared and displayed as saw-tooth wave; (4) The incidence of biliary complications in liver transplantation was increased when DPI was reduced; (5) Seven cases of hepatic carcinoma relapse after OLT demonstrated hyperecho in the arterial phase and hypoecho in the portal and later phase on CEUS; (6) In 2 cases of HA thrombus, there was no visualized enhancement in arterial phase of CEUS, but enhancement during the portal vein and parenchymal phase. It was concluded that the hemodynamic changes of PV, HA and HV in the transplanted liver are valuable for assessing the transplanted liver and early diagnosing complications on CDFI and CEUS. 展开更多
关键词 color doppler flow imaging liver transplantation HEMODYNAMICS postoperative complications intravenous contrast-enhanced ultrasound
下载PDF
PRELIMINARY APPLICATION OF COLOR DOPPLER FLOW IMAGING IN THE LOCALIZATION OF PARATHYROID ADENOMAS
3
作者 张缙熙 李建初 《Chinese Medical Sciences Journal》 CAS CSCD 1994年第3期187-189,共3页
From December 1991 to April 1993, we performed color Doppler flow imaging (CDFI) in 11 patients with parathyroid adenoma, and all cases were confirmed by operation and pathology. In all the parathyroid adenomas,vesse... From December 1991 to April 1993, we performed color Doppler flow imaging (CDFI) in 11 patients with parathyroid adenoma, and all cases were confirmed by operation and pathology. In all the parathyroid adenomas,vessels were clearly revealed at the periphery of the upper pole and/or anterior periphery, where arterial signals were elicited. These arteries had branches into the adenomas and originated from inferior thyroid arteries on the same side in most cases. The internal flow signals were increased markedly as compared to normal thyroid, and high-velocity arterial signals were detected. Because of the thyroid' s rich blood supply and landmark peripheral vessels, CDFI can distinguish parathyroid foci from thyroid nodules, lymph nodes, and normal tissues and provide a sound basis for the diagnosis of small parathyroid foci. 展开更多
关键词 color doppler flow imaging parathyroid adenoma localization diagnosis
下载PDF
Left Coronary Artery Fistula Identified by Color Doppler Flow Imaging
4
作者 杨娅 李治安 +1 位作者 王新房 邓又兵 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1995年第3期176-177,共2页
Coronary artery fistula (CAF) is an abnormal communication between a coronary artery and a cardiac chamber, great vessel,or other vascular structures. The presence of the fistula is usually identified by angiography. ... Coronary artery fistula (CAF) is an abnormal communication between a coronary artery and a cardiac chamber, great vessel,or other vascular structures. The presence of the fistula is usually identified by angiography. In this paper, the diagnosis of left coronary artery-right ventricle fistula was made by color Doppler before angiography? and it was confirmed by surgery.Color Doppler flow imaging is a noninvasive method which can reveal the proximal dilatation, the course and the draining site of CAF. 展开更多
关键词 coronary artery fistula color doppler flow imaging
下载PDF
Thrombelastography and color Doppler flow imaging in the perioperative period after closed lower limb fracture
5
作者 徐志强 《外科研究与新技术》 2011年第2期114-115,共2页
Objective To observe the changes of thrombelastography (TEG) and color Doppler flow imaging (CDFI) in the perioperative period after closed lower limb fracture.Methods Fasting venous blood samples in the morning from ... Objective To observe the changes of thrombelastography (TEG) and color Doppler flow imaging (CDFI) in the perioperative period after closed lower limb fracture.Methods Fasting venous blood samples in the morning from 11 healthy adults were used 展开更多
关键词 CDFI Thrombelastography and color doppler flow imaging in the perioperative period after closed lower limb fracture flow
下载PDF
Design of axial flaps with color Doppler flow imaging technique for repairing deep wounds of heels
6
作者 黎洪棉 《外科研究与新技术》 2005年第3期215-215,共1页
To report the methods and effect of axial pattern flap on lower limb in repairing deep wounds of heels by using color Doppler flow imaging (CDFI) technique so as to solve the ever before problems that the vessel can n... To report the methods and effect of axial pattern flap on lower limb in repairing deep wounds of heels by using color Doppler flow imaging (CDFI) technique so as to solve the ever before problems that the vessel can not be displayed in designing axial flap.Methods Suitable axial flaps on lower limbs were selected according to the character of the wounds.There were 25 flaps including 10 cases of the distal-based sural neurovascular flap,nine medial sole flap and six medial leg flap.All the axial pattern flaps were designed on the basis of traditional design ways before operation;then,CDFI appliance with high resolution was used to examine the starting spot,exterior diameter,trail and length of the flap’s major artery.The flaps were redesigned according to the results of CDFI and transferred to cover the wounds.In the meantime,both the results of operation and examination were compared.Results The major artery’s starting spot,exterior diameter,trail and anatomic layers were displayed clearly,in consistency with the results of operation.The flaps survived completely and recovered well,with perfect appearance,color and arthral function.Conclusion CDFI is a simple,macroscopic and atraumatic method for designing the axial pattern flap on lower limb,can provide more scientific and accurate evidence for preoperative determination of flap transplantation and is worthy of clinical application.10 refs,4 figs,2 tabs. 展开更多
关键词 Design of axial flaps with color doppler flow imaging technique for repairing deep wounds of heels
下载PDF
Value of Acceleration Flow in the Left Anterior Descending Coronary Artery for the Detection of Coronary Artery Stenosis by Transthoracic Coronary Color Doppler Echocardiography
7
作者 陈斌 邓又斌 +4 位作者 杨好意 阮燕菲 常青 毕小军 王红英 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2005年第5期597-600,共4页
Summary: Whether the localized flow acceleration occurs in the resting stenotie left anterior descending coronary artery was explored and its value for detection of coronary stenosis estimated. Blood flow in the left... Summary: Whether the localized flow acceleration occurs in the resting stenotie left anterior descending coronary artery was explored and its value for detection of coronary stenosis estimated. Blood flow in the left anterior descending coronary arteries in 45 patients was detected by transthoratio color Doppler echocardiograph and multipoint pulse Doppler spectrums were recorded in the same segment. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was calculated. The ratio ≥1.5 was the cutoff value for the presence of localized acceleration flow. There were 23 patients with localized acceleration flow examined by eehoeardiography. Twenty of them were found to have luminal diameter stenosis (60%-98%) in the left anterior descending coronary arteries by coronary angiography and 3 patients were normal. There were 22 patients without localized acceleration flow examined by eehoeardiography. Eighteen of them had no or %60 stenosis. Four patients had serious stenosis (≥95%) or occluded segments in the left anterior descending coronary arteries on coronary angiography. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was significantly higher in patients with left anterior descending coronary artery stenosis than that in those without stenosis (1.9±0.3 vs 1.3±0.2, P〈0.01) and it correlated significantly with left anterior descending coronary artery stenosis (r=0.77, P〈0.01). The specificity by using the ratio≥1. 5 for stenosis detection was 85.7% (18/ 21), and the sensitivity was 83.3% (20/24). This study demonstrated that local blood flow velocity was increased in the resting stenotie left anterior descending coronary artery. Transthoraeie color Doppler eehoeardiography is a reliable noninvasive method to detect localized acceleration flow in the left anterior descending coronary artery stenosis and it is useful in the noninvasive diagnosis of stenosis in the left anterior descending coronary artery. 展开更多
关键词 ECHOCARDIOGRAPHY coronary artery STENOSIS color doppler flow imaging
下载PDF
The Study of Ovarian Artery Hemodynamics in Patients with Infertility by Color Doppler Energy 被引量:2
8
作者 肖先桃 乐桂蓉 +1 位作者 张友耿 黎春蕾 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2001年第1期42-43,共2页
Seventy four cases of infertility were examined to study the hemodynamics of the bilateral ovarian arteries at 21st day during the corpus luteum phase by color Doppler energy(CDE) and color Doppler flow imaging (CDFI... Seventy four cases of infertility were examined to study the hemodynamics of the bilateral ovarian arteries at 21st day during the corpus luteum phase by color Doppler energy(CDE) and color Doppler flow imaging (CDFI). All the patients were verified by laparoscopy, fallopian tube patency examination and ovarian function test. Twenty two healthy women served as controls. The results showed that the difference of resistance index(RI)and pulsatility index (PI) of bilateral ovarian arteries between the infertility and the normal controls had statistical significance ( P <0.01), and the PI showed negative correlation with the thickness of endometrium (left side: r =0.724, P <0.01; right side: r =0.756, P <0.01). The results also showed that CDE was more sensitive than CDFI in displaying the ovarian arteries. It could be concluded that the elevated resistance of ovarian artery during the corpus luteum phase was one of the important factors that resulted in infertility. 展开更多
关键词 ovarian artery color doppler flow imaging color doppler energy resistance index pulsatility index INFERTILITY
下载PDF
CHARACTERISTICS OF TWO-DIMENSIONAL AND COLOR DOPPLER ULTRASONOGRAPHY IN GRAVES'DISEASE 被引量:1
9
作者 李建初 张缙熙 +3 位作者 白耀 程玉芳 蔡胜 孙宏宇 《Chinese Medical Sciences Journal》 CAS CSCD 1994年第2期104-107,共4页
Color Doppler flow imaging(CDFI) was performed in 24 patients with Graves' disease and the results were compared with those from 8 patients with Hashimoto's disease, 6 patients with simple diffuse goiter, and ... Color Doppler flow imaging(CDFI) was performed in 24 patients with Graves' disease and the results were compared with those from 8 patients with Hashimoto's disease, 6 patients with simple diffuse goiter, and 15 normal volunteers. All cases were confirmed by clinical, laboratory tests or pathology. CDFI of Graves' disease showed diffuse or localized hypoechoes within the thyroid glands, rich flow signals in the hypoechoes, accelerated flow velocity, and decreased resistance in the superior thyroid arteries(STA) and arteries within the glands. These appearances were characteristic as compared with the controls. The rate of flow in STA of Graves' disease patients was 8 to 10 times higher than that in the normal volunteers. This study demonstrates that CDFI is convenient and efficient as compared with isotope scan and some other laboratory tests, and can be widely used in the diagnosis of Graves' disase. 展开更多
关键词 color doppler flow imaging Graves'disease
下载PDF
The application of color Doppler flow imaging in the diagnosis and therapeutic effect evaluation of erectile dysfunction 被引量:4
10
作者 Xu-Jun Xuan Gang Bai +6 位作者 Cai-Xia Zhang Chao Xu Fu-Ding Lu Yang Peng Gang Ma Cong-Hui Han Jun Chen 《Asian Journal of Andrology》 SCIE CAS CSCD 2016年第1期118-122,共5页
We aim to investigate the correlations between hemodynamic parameters, penile rigidity grading, and the therapeutic effects of phosphodiesterase type 5 inhibitors using color Doppler flow imaging after intracavernosal... We aim to investigate the correlations between hemodynamic parameters, penile rigidity grading, and the therapeutic effects of phosphodiesterase type 5 inhibitors using color Doppler flow imaging after intracavernosal injection in patients with erectile dysfunction. This study involved 164 patients. After intracavernosal injection with a mixture of papaverine (60 mg), prostaglandin E1 (10 μg), and lidocaine (2%, 0.5-1 ml), the penile vessels were assessed using color Doppler flow imaging. Penile rigidity was classified based on the Erection Hardness Score system as Grades 4, 3, 2 or 1 (corresponding to Schramek Grades Ⅴ to Ⅱ). Then, the patients were given oral sildenafil (50-100 mg) and scored according to the International Index of Erectile Function (IIEF-5) questionnaire. The number of patients with penile rigidities of Schramek Grades Ⅱ to Ⅴ was 14, 18, 21, and 111, respectively. The IIEF-5 score was positively correlated with the refilling index of the penile cavernosal artery (r = 0.79, P 〈 0.05), the peak systolic velocity (r= 0.45, P〈 0.05), and penile rigidity (r= 0.75, P〈 0.05), and was negatively correlated with the end diastolic velocity (r = -0.74, P 〈 0.05). For patients with erectile dysfunction, both the IIEF-5 score after sildenafil administration, which is correlated with penile rigidity, and the hemodynamic parameters detected using color Doppler flow imaging may predict the effects of phosphodiesterase type 5 inhibitor treatment and could provide a reasonable model for the targeted-treatment of erectile dysfunction. 展开更多
关键词 color doppler flow imaging erectile dysfunction hemodynamic parameters penis rigidity SILDENAFIL
原文传递
Application and prospects of AI-based radiomics in ultrasound diagnosis
11
作者 Haoyan Zhang Zheling Meng +2 位作者 Jinyu Ru Yaqing Meng Kun Wang 《Visual Computing for Industry,Biomedicine,and Art》 EI 2023年第1期288-303,共16页
Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high tempora... Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high temporal resolution, low cost, and no radiation exposure. This renders it a preferred imaging modality for several clinical scenarios. This review includes a detailed introduction to imaging modalities, including Brightness-mode ultrasound, color Doppler flow imaging, ultrasound elastography, contrast-enhanced ultrasound, and multi-modal fusion analysis. It provides an overview of the current status and prospects of AI-based radiomics in ultrasound diagnosis, highlighting the application of AI-based radiomics to static ultrasound images, dynamic ultrasound videos, and multi-modal ultrasound fusion analysis. 展开更多
关键词 Radiomics Ultrasound imaging Artificial intelligence Deep learning B-mode ultrasound color doppler flow imaging Ultrasound elastography Contrast-enhanced ultrasound Multimodal ultrasound
下载PDF
Clinical Value of Ultrosound in the Diagnosis of Testicular Tumor
12
作者 罗冬喜 杨为民 +3 位作者 叶章群 刘继红 孟磊 周四维 《The Chinese-German Journal of Clinical Oncology》 CAS 2003年第4期231-233,253,共4页
Objective: To summarize the clinical experience of diagnosis and treatment of the testicular tumors.Methods: Retrospective analysis of 42 adult patients with testicular cancers was carried out.Results: Ultrasonography... Objective: To summarize the clinical experience of diagnosis and treatment of the testicular tumors.Methods: Retrospective analysis of 42 adult patients with testicular cancers was carried out.Results: Ultrasonography (B-ultrasound and color Doppler flow imaging) was performed on 37 cases. One case was misdiagnosed. Surgical management was carried out in 42 cases and postoperational radiation therapy or chemotherapy was performed. The 1–5 year postoperative survival rate was totally 100%.Conclusion: B-ultrasound, especially color Doppler flow imaging, with the advantages of noninvasiveness and inexpensiveness was most useful and should be firstly employed in diagnosing the testicular tumor. The favorable prognosis can be obtained if an early diagnosis is made and the early treatment is performed. Key words testicular tumor - B-ultrasound - color Doppler flow imaging 展开更多
关键词 testicular tumor B-ULTRASOUND color doppler flow imaging
下载PDF
Feasibility of Transabdominal Real-time CDFI and HDFI Techniques for Fetal Pulmonary Vein Display in the First Trimester
13
作者 Dong-mei LIN Yun-xiao ZHU +4 位作者 Ying TAN Yu-jun HUANG Kun YUAN Wen-fen LIU Zuo-feng XU 《Current Medical Science》 SCIE CAS 2022年第3期635-641,共7页
Objective This study aimed to assess the feasibility and usefulness of transabdominal color Doppler flow imaging(CDFI)technology and the high-definition flow imaging(HDFI)technique in detecting fetal pulmonary veins(P... Objective This study aimed to assess the feasibility and usefulness of transabdominal color Doppler flow imaging(CDFI)technology and the high-definition flow imaging(HDFI)technique in detecting fetal pulmonary veins(PVs)in the first trimester(11–13^(+6)weeks).Methods From December 2018 to October 2019,328 pregnant women with 328 normal singleton fetuses(crown-rump length:45–84 mm)who had undergone CDFI and HDFI scans for fetal heart and vessel examination were enrolled in this study.The cases were divided into three groups according to the gestational age:group A,11^(+0)−11^(+6)weeks;group B,12^(+0)−12^(+6)weeks;and group C,13^(+0)−13^(+6)weeks.Baseline sonograms and CDFI and HDFI images were analyzed by two senior radiologists independently and blindly.The abilities of CDFI and HDFI to display PVs were compared.Results Successful PV display rates via CDFI and HDFI were 2.3%and 68.2%(P<0.01),22.4%and 82.4%(P<0.01),41.5%and 91.2%(P<0.01)for group A,group B,and group C,respectively.The total successful display rates for the two methods were 28.9%(CDFI)and 84.8%(HDFI)(P<0.01).Conclusions The HDFI technique is more valuable than CDFI for detecting PVs in early pregnancy(11–13^(+6)weeks).HDFI can detect at least one PV in all cases and may be used to detect pulmonary venous anomalies early. 展开更多
关键词 pulmonary vein first trimester prenatal sonography high-definition flow imaging color doppler flow imaging
下载PDF
Ocular surface heat effects on ocular hemodynamics detected by real-time measuring device
14
作者 Ting-Ting Li Guang-Bin Shao +4 位作者 Yu-Long Jiang Jing-Xuan Wang Xin-Rong Zhou Min Ren Long-Qiu Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第12期1902-1908,共7页
AIM: To investigate the ocular hemodynamic effects of applying a hot compress to the eye.METHODS: The right eyes of five New Zealand white rabbits, both male and female, were hot-compressed for 18 min. An independentl... AIM: To investigate the ocular hemodynamic effects of applying a hot compress to the eye.METHODS: The right eyes of five New Zealand white rabbits, both male and female, were hot-compressed for 18 min. An independently designed novel ocular contacttype temperature measuring device was used to measure the ocular surface temperature before and after the heating. Relevant retrobulbar hemodynamic parameters such as peak systolic velocity(PSV), end diastolic velocity(EDV), and resistance index(RI) of each of the central retinal artery(CRA), long posterior ciliary artery(LPCA), and ophthalmic artery(OA), as well as the mean velocity(V_m) of the central retinal vein(CRV), were measured using a color Doppler flow imaging(CDFI) technique and expressed as mean values with standard deviation(mean±SD). A statistical analysis was conducted based on a paired t-test and the Wilcoxon signed-rank test. RESULTS: The employed real-time temperature measuring device was able to accurately measure ocular surface temperature during the hot-compress process. The temperature increased after the hot compress was applied. Analysis showed that the PSV and EDV values of the CRA and LPCA significantly increased after the application of the hot compress, as did the V_m of the CRV. There were no significant changes in the EDV of the OA nor the RI of each artery. CONCLUSION: This experiment, which is the first of its kind, confirms that the retrobulbar blood flow velocities can increase upon heating the ocular surface. This simple method may be useful in the future. 展开更多
关键词 ocular hemodynamics ocular surface heating temperature detection device color doppler flow imaging
下载PDF
Contrast-enhanced Ultrasound in Detecting Endoleaks with Failed Computed Tomography Angiography Diagnosis after Endovascular Abdominal Aortic Aneurysm Repair 被引量:8
15
作者 Xiao Yang Yue-Xin Chen +5 位作者 Bo Zhang Yu-Xin Jiang Chang-Wei Liu Rui-Na Zhao Qiong Wu Da-Ming Zhang 《Chinese Medical Journal》 SCIE CAS CSCD 2015年第18期2491-2497,共7页
Background: Endovascular aneurysnl repair (EVAR) is one of the first-line therapies of abdominal aortic aneurysms. Postoperative endoleak is the most common complication of EVAR. Computed tomography angiography (... Background: Endovascular aneurysnl repair (EVAR) is one of the first-line therapies of abdominal aortic aneurysms. Postoperative endoleak is the most common complication of EVAR. Computed tomography angiography (CTA), which is routine for follow-up, has side effects (e.g., radiation) and also has a certain percentage of missed diagnosis. Preliminary studies on contrast-enhanced ultrasound (CEUS) have shown that the sensitivity of CEUS for detecting endoleak is no lower than that of CTA. To investigate the advantages of CEUS, we conducted CEUS examinations of post-EVAR cases in which CTA failed to detect endoleak or could not verify the type of endoleak. Methods: Post-EVAR patients, who were clinically considered to have endoleak and met the inclusion criteria were enrolled between March 2013 and November 2014. All of the patients underwent color Doppler flow imaging (CDFI) and a CEUS examination. Size, location, microbubble dispersion, and hemodynamic characteristics of leaks were recorded. Comparison between the diagnosis of CEUS and CDF1 was conducted using Fisher's exact test and clinical outcomes of all patients were followed up. Results: Sixteen patients were enrolled, and 12 (75%) had endoleaks with verified types by CEUS. Among 12 cases of endoleaks were positive by CEUS, 10 were CDFl-positive, and the four CEUS-negative cases were all negative by CDFI. The diagnostic values of CEUS and CDFI were statistically difl'erent (P = 0,008). Six patients with high-pressure endoleaks received endovascular re-intervention guided by CEUS results. One patient with type Ⅲ endoleak had open surgery when endovascular repair failed. Conclusions: C EUS is a new, safe, and effective means for detection ofendoleaks post-EVAR. This technique can be used as a supplement for routine CTA follow-up to provide more detailed information on endoleak and its category. 展开更多
关键词 Abdominal Aortic Aneurysnl: color doppler flow imaging Contrast-enhanced Ultrasound: Endoleak EndovascularAneurysm Repair
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部