Double-pulse LIBS is a promising technique for deep-sea applications.LIBS measurements in shallow water with up to 400 mJ each pulse were done to select laser parameters which promote optimized spectral line emission ...Double-pulse LIBS is a promising technique for deep-sea applications.LIBS measurements in shallow water with up to 400 mJ each pulse were done to select laser parameters which promote optimized spectral line emission from plasma even at elevated pressures,where line broadening until loss of most of the spectral information can occur.Optical emission spectroscopy,using a Czerny-Turner spectrometer,has been applied to investigate the dependence of the emitted radiation on laser parameters and hydrostatic pressure.It has been found,that higher laser pulse energies,especially with short pulse delay as required in high water pressure,can also have an adverse effect on the measured spectrum.展开更多
Welding voltage and current in arc signals are directly related to arc stability and welding quality.Process experiments with different parameters were organized according to the orthogonal experimental design method ...Welding voltage and current in arc signals are directly related to arc stability and welding quality.Process experiments with different parameters were organized according to the orthogonal experimental design method by constructing an aluminum alloy double-pulse metal inert gas(MIG)welding arc electric signal test platform.The data acquisition system of the aluminum alloy MIG welding process was established to obtain real-time arc signal information reflecting the welding process.The aluminum alloy’s collected double-pulse arc current signals are decomposed adaptively by broadband mode decomposition(BMD).The direct current(DC)signal,pulse signal,distortion signal,ripple signal,and noise signal are separated and extracted,and the composite multiscale fuzzy entropy(CMFE)is calculated for the component set of the electrical signal.The experimental results show that the current waveform obtained by the double-pulse MIG welding current signal is consistent with the corresponding weld forming diagram.Simultaneously,the composite multiscale fuzzy entropy is calculated for the arc characteristic parameters.The rationality of matching process parameters and arc stability of aluminum alloy’s double-pulse MIG welding were evaluated.展开更多
The effect of current on the morphology of Al alloy T-joint in double-pulsed metal inert gas(DP-MIG) welding process was investigated by simulation and experiment.A three-dimensional finite element model and the DP-...The effect of current on the morphology of Al alloy T-joint in double-pulsed metal inert gas(DP-MIG) welding process was investigated by simulation and experiment.A three-dimensional finite element model and the DP-MIG heat source of double-ellipsoidal volumetric model were developed to simulate the temperature and stress fields under different welding conditions.The macro-morphology and microstructure of welding joints at the corresponding currents were observed in the experiment.The results show that the best condition is at an average current of 90 A and current difference of 40 A,when the maximum temperature is 200 °C higher than the fusion points,with the temperature difference of about 100 °C and stress change of 10 MPa between thermal pulse and thermal base.Under these conditions,Al alloy T-joint with proper fusion condition has smooth fish-scale welding appearance and finer microstructure.Furthermore,the thermal curves and stress distribution in the experiment are consistent with those in the simulation,verifying the precision of the welding simulation.展开更多
In this study, a stand-off and collinear double pulse laser-induced breakdown spectroscopy (DP LIBS) system was designed, and the magnesium alloy samples at a distance of 2.5 m away from the LIBS system were measure...In this study, a stand-off and collinear double pulse laser-induced breakdown spectroscopy (DP LIBS) system was designed, and the magnesium alloy samples at a distance of 2.5 m away from the LIBS system were measured. The effect of inter-pulse delay on spectra was studied, and the signal enhancement was observed compared to the single pulse LIBS (SP LIBS). The morphology of the ablated crater on the sample indicated a higher efficiency of surface pretreatment in DP LIBS. The calibration curves of Ytterbium (Y) and Zirconium (Zr) were investigated. The square of the correlation coefficient of the calibration curve of element Y reached up to 0.9998.展开更多
In this paper, we present a study on the effect of inter-pulse delay using femtosecond double-pulse laser-induced breakdown spectroscopy in a collinear geometry. The temporal evolution of spectral intensity is perform...In this paper, we present a study on the effect of inter-pulse delay using femtosecond double-pulse laser-induced breakdown spectroscopy in a collinear geometry. The temporal evolution of spectral intensity is performed for the lines of Fe I 423.60 nm, Fe I 425.08 nm and Fe I 427.18 nm. It is found that, by selecting appropriate inter-pulse delay, the signal enhancement can be significantly increased compared with the single-pulse case. A three-fold enhancement in the current experiment is obtained. The plasma temperature and electron density are also investigated based on the theory of Boltzmann plot and Stark broadening. We attribute the main mechanism for emission enhancement to the plasma re-heating effect.展开更多
New tungsten ion source is produced by using single and double-pulse laser ablation system. Combined collinear Nd:YAG laser beams(266+1064 nm) are optimized to focus on the sample in air. Optimization of the exper...New tungsten ion source is produced by using single and double-pulse laser ablation system. Combined collinear Nd:YAG laser beams(266+1064 nm) are optimized to focus on the sample in air. Optimization of the experimental parameters is achieved to enhance the signal-to-noise ratio of the emission spectra. The velocity distribution of the emitted plasma cloud is carefully measured. The influences of the potential difference between the bias electrodes, laser wavelength and intensity on the current signal are also studied. The results show that the increase in the tungsten ion velocity under the double-pulse lasers causes the output current signal to increase by about three folds. The electron density and temperature are calculated by using the Stark-broadened line profile of tungsten line and Boltzmann plot method of the upper energy levels, respectively. The signal intensity dependence of the tungsten ion angular distribution is also analyzed. The results indicate that the double-pulse laser ablation configuration is more potent technique for producing more metal ion source deposition, thin film formation, and activated plasma-facing component material.展开更多
We designed a femtosecond(fs)+picosecond(ps)double-pulse sequence by using a Mach-Zehnder-like apparatus to split a single 120 fs pulse into two sub-pulses,and one of them was stretched to a width of 2 ps by a four-pa...We designed a femtosecond(fs)+picosecond(ps)double-pulse sequence by using a Mach-Zehnder-like apparatus to split a single 120 fs pulse into two sub-pulses,and one of them was stretched to a width of 2 ps by a four-pass grating system.Through observing the ripples induced on the ZnO surface,we found the ionization rate appeared to be higher for the sequence in which the fs pulse arrived first.The electron rate equation was used to calculate changes of electron density distribution for the sequences with different delay times.We suggest that using a temporally shaped fs+ps pulse sequence can achieve nonlinear ionization control and influence the induced ripples.展开更多
To monitor the components of molten magnesium alloy during the smelting process in real time and online, we designed a standoff double-pulse laser-induced breakdown spectroscopy (LIBS) analysis system that can perfo...To monitor the components of molten magnesium alloy during the smelting process in real time and online, we designed a standoff double-pulse laser-induced breakdown spectroscopy (LIBS) analysis system that can perform focusing, collecting and imaging of long-range samples. First, we tested the system on solid standard magnesium alloy samples in the laboratory to establish a basis for the online monitoring of the components of molten magnesium alloy in the future. The experimental results show that the diameters of the focus spots are approximately 1 mm at a range of 3 m, the ablation depth of the double-pulse mode is much deeper than that of the single-pulse mode, the optimum interpulse delay of the double pulse is inconsistent at different ranges, and the spectral intensity decays rapidly as the range increases. In addition, the enhancement effect of the double pulse at 1.89 m is greater than that at 2.97 m, the maximum enhancement is 7.1-fold for the Y(I)550.35-nm line at 1.89 m, and the calibration results at 1.89 m are better than those at 2.97 m. At 1.89 m, the determination coefficients (R2) of the calibration curves are approximately 99% for Y, Pr, and Zr; the relative standard deviations (RSDs) are less than 10% for Y, Pr, and Zr; the root mean square errors (RMSEs) are less than 0.037% for Pr and Zr; the limits of detection (LODs) are less than 1000 ppm for Y, Pr, and Zr; and the LODs of Y, Pr, and Zr at 2.97 m are higher than those at 1.89 m. Additionally, we tested the system on molten magnesium alloy in a magnesium alloy plant. The calibration results of the liquid magnesium alloy are not as favorable as those of the sampling solid magnesium alloys. In particular, the RSDs of the liquid magnesium alloy are approximately 20% for Pr and La. However, with future improvements in the experimental conditions, the developed system is promising for the in situ analysis of molten magnesium alloy.展开更多
In the photodetachment of atoms or negative ions by a double-pulse laser, the first pulse of the double-pulse laser generates waves and the delayed second pulse may detect them. The phenomenon of the excitation and de...In the photodetachment of atoms or negative ions by a double-pulse laser, the first pulse of the double-pulse laser generates waves and the delayed second pulse may detect them. The phenomenon of the excitation and detection of waves by a double-pulse laser can be used to identify the closed orbits in the system. We demonstrate this phenomenon with a negative hydrogen ion(H^-) by analyzing the total population excited by a double-pulse laser in a timedependent field for different physical parameters. By analyzing the total excited population using a double-pulse laser, we can uncover all the closed orbits existing in the system. We demonstrate that this can be realized by scanning the first pulse position and the time delay between the two pulses.展开更多
Four different welding sequences of double-pulse MIG welding were conducted for 6061-T6 aluminum alloy automobile bumpers by using nonlinear elastoplasticity finite element method based on ABAQUS software.The post-wel...Four different welding sequences of double-pulse MIG welding were conducted for 6061-T6 aluminum alloy automobile bumpers by using nonlinear elastoplasticity finite element method based on ABAQUS software.The post-welding residual stress and deformation were definitely different among the four welding sequences.The results showed that the highest temperature in Solution A was approximately 200℃higher than the melting point of base metal.High residual stress was resulted from this large temperature gradient and mainly concentrated on the welding vicinity between beam and crash box.The welding deformation primarily occurred in both of the contraction of two-ends of the beam and the self-contraction of crash box.Compared with other welding sequences,the residual stress in Solution A was the smallest,whereas the welding deformation was the largest.However,the optimal sequence was Solution B because of the effective reduction of residual stress and good assembly requirements.展开更多
6061 aluminum alloy T-joints were welded by double-pulsed MIG welding process. Then, the post-weld heat treatment was performed on the welded T-joints. The weld microstructure under different aging temperature and tim...6061 aluminum alloy T-joints were welded by double-pulsed MIG welding process. Then, the post-weld heat treatment was performed on the welded T-joints. The weld microstructure under different aging temperature and time was investigated by transmission electron microscopy and scanning electron microscopy. The mechanical properties were examined by hardness test and tensile test. The results showed that the micro-hardness was sensitive to heat treatment temperature and time. Increasing temperature was beneficial to the shortening of peak aging time. There were a large number of dislocations and few precipitates in the welded joints. With the increase of post-weld heat treatment temperature and time, the density of dislocation decreased. Meanwhile, the strengthening phase precipitated and grew up gradually. When the post-weld heat treatment temperature increased up to 200℃, large Q' phases were observed. And they were responsible for the peak value of the micro-hardness in the welded joints.展开更多
A novel spatial double-pulse laser ablation scheme is investigated to enhance the processing quality and efficiency fornanosecond laser ablation of silicon substrate. During the double-pulse laser ablation, two splitt...A novel spatial double-pulse laser ablation scheme is investigated to enhance the processing quality and efficiency fornanosecond laser ablation of silicon substrate. During the double-pulse laser ablation, two splitted laser beams simulta-neously irradiate on silicon surface at a tunable gap. The ablation quality and efficiency are evaluated by both scanning electron microscope and laser scanning confocal microscope. As tuning the gap distance, the ablation can be signifi-cantly enhanced if the spatial interaction between the two splitted laser pulses is optimized. The underlying physical mechanism for the interacting spatial double-pulse enhancement effect is attributed to the redistribution of the integratedenergy field, corresponding to the temperature field. This new method has great potential applications in laser microm-achining of functional devices at higher processing quality and faster speed.展开更多
To make full use of expanded maneuverability and increased range,adaptive constrained on-board guidance technology is the key capability for a glide vehicle with a double-pulse rocket engine,especially under the requi...To make full use of expanded maneuverability and increased range,adaptive constrained on-board guidance technology is the key capability for a glide vehicle with a double-pulse rocket engine,especially under the requirements of desired target changing and on-line reconfigurable control and guidance.Based on the rapid footprint analysis,whether the new target is within the current footprint area is firstly judged.If not,the rocket engine ignites by the logic obtained from the analysis of optimal flight range by the method of hp-adaptive Gauss pseudospectral method(hp-GPM).Then,an on-board trajectory generation method based on powered quasi-equilibrium glide condition(QEGC)and linear quadratic regulator(LQR)method is used to guide the vehicle to the new target.The effectiveness of the guidance method consisted of powered on-board trajectory generation,LQR trajectory tracking,footprint calculation,and ignition time determination is indicated by some simulation examples.展开更多
Wide bandgap(WBG)semiconductors,such as silicon carbide(SiC)and gallium nitride(GaN),exhibit superior physical properties and demonstrate great potential for replacing conventional silicon(Si)semiconductors with WBG t...Wide bandgap(WBG)semiconductors,such as silicon carbide(SiC)and gallium nitride(GaN),exhibit superior physical properties and demonstrate great potential for replacing conventional silicon(Si)semiconductors with WBG technology,pushing the boundaries of power devices to handle higher blocking voltages,switching frequencies,output power levels,and operating temperatures.However,tradeoffs in switching performance and converter efficiency when substituting GaN devices for Si and SiC counterparts are not well-defined,especially in a cascode configuration.Additional research with further detailed investigation and analysis is necessitated for medium-voltage GaN devices in power converter applications.Therefore,the aim of this research is to experimentally investigate the impact of emerging 650/900 V cascode GaN devices on bidirectional dc-dc converters that are suitable for energy storage and distributed renewable energy systems.Dynamic characteristics of Si,SiC,and cascode GaN power devices are examined through the double-pulse test(DPT)circuit at different gate resistance values,device currents,and DC bus voltages.Furthermore,the switching behavior and energy loss as well as the rate of voltage and current changes over the time are studied and analyzed at various operating conditions.A 500 W experimental converter prototype is implemented to validate the benefits of cascode GaN devices on the converter operation and performance.Comprehensive analysis of the power losses and efficiency improvements for Si-based,SiC-based,and GaN-based converters are performed and evaluated as the switching frequency,working temperature,and output power level are in-creased.The experimental results reveal significant improvements in switching performance and energy efficiency from the emerging cascode GaN devices in the bidirectional converters.展开更多
We propose a method to suppress deceptive jamming by frequency diverse array (FDA) in radar electronic coun- termeasure environments. FDA offers a new range-angle-dependent beam pattern through a small frequency inc...We propose a method to suppress deceptive jamming by frequency diverse array (FDA) in radar electronic coun- termeasure environments. FDA offers a new range-angle-dependent beam pattern through a small frequency increment across elements. Due to the coupling between the angle and range, a mismatch between the test angle and physical angle occurs when the slant range on which the beam focuses is not equal to the slant range of the real target. In addition, the range of the target can be extracted by sum-difference beam except for time-delay testing, because the beam provides a range resolution in the FDA that cannot be deceived by traditional deceptive jamming. A strategy of using FDA to transmit two pulses with zero and nonzero frequency increments, respectively, is proposed to ensure that the angle of a target can be obtained by FDA. Moreover, the lo- calization performance is examined by analyzing the Cramer-Rao lower bound and detection probability. Effectiveness of the proposed method is confirmed by simulation results.展开更多
The dispersive Fourier transform technique provides feasibility of exploring non-repetitive events and the buildup process in ultrafast lasers.In this paper,we report a new buildup process of dissipative solitons in a...The dispersive Fourier transform technique provides feasibility of exploring non-repetitive events and the buildup process in ultrafast lasers.In this paper,we report a new buildup process of dissipative solitons in a simplified mode-locked Yb-doped fiber laser,which includes more complex physics stages such as the Q-switching stage,raised and damped relaxation oscillation stages,noise-like stage,successive soliton explosions stage,and soliton breathing stage.Complete evolution dynamics of noise-like pulse and double pulse are also investigated with dispersive Fourier transform.For the noise-like pulse dynamics process,it will only experience the Q-switching and relaxation oscillation stages.In the case of dissipative soliton and noise-like pulse,the double pulse buildup behavior is manifested as the replication of individual pulses.A weak energy migration occurs between two pulses before reaching steady state.Meanwhile,real-time mutual conversion of the dissipative soliton and noise-like pulse has been experimentally observed,which appears to be instantaneous without extra physical processes.To the best of our knowledge,this is the first report on these physical phenomena observed together in a mode-locked fiber laser.The results further enrich the dynamics of mode-locked fiber lasers and provide potential conditions for obtaining intelligent mode-locked lasers with controllable output.展开更多
基金funded by the Deutsche Forschungsgemeinschaft(DFG,German Research Foundation)–Project No.454848899。
文摘Double-pulse LIBS is a promising technique for deep-sea applications.LIBS measurements in shallow water with up to 400 mJ each pulse were done to select laser parameters which promote optimized spectral line emission from plasma even at elevated pressures,where line broadening until loss of most of the spectral information can occur.Optical emission spectroscopy,using a Czerny-Turner spectrometer,has been applied to investigate the dependence of the emitted radiation on laser parameters and hydrostatic pressure.It has been found,that higher laser pulse energies,especially with short pulse delay as required in high water pressure,can also have an adverse effect on the measured spectrum.
基金The 2024 University-level Higher Education Teaching Reform Project of Guangzhou Xinhua University,“Teaching Reform and Practice Based on OBE Concept”:A Case Study of“University Physics Experiment”(Project No.2024J044)。
文摘Welding voltage and current in arc signals are directly related to arc stability and welding quality.Process experiments with different parameters were organized according to the orthogonal experimental design method by constructing an aluminum alloy double-pulse metal inert gas(MIG)welding arc electric signal test platform.The data acquisition system of the aluminum alloy MIG welding process was established to obtain real-time arc signal information reflecting the welding process.The aluminum alloy’s collected double-pulse arc current signals are decomposed adaptively by broadband mode decomposition(BMD).The direct current(DC)signal,pulse signal,distortion signal,ripple signal,and noise signal are separated and extracted,and the composite multiscale fuzzy entropy(CMFE)is calculated for the component set of the electrical signal.The experimental results show that the current waveform obtained by the double-pulse MIG welding current signal is consistent with the corresponding weld forming diagram.Simultaneously,the composite multiscale fuzzy entropy is calculated for the arc characteristic parameters.The rationality of matching process parameters and arc stability of aluminum alloy’s double-pulse MIG welding were evaluated.
基金Project(51475156)supported by the National Natural Science Foundation of China
文摘The effect of current on the morphology of Al alloy T-joint in double-pulsed metal inert gas(DP-MIG) welding process was investigated by simulation and experiment.A three-dimensional finite element model and the DP-MIG heat source of double-ellipsoidal volumetric model were developed to simulate the temperature and stress fields under different welding conditions.The macro-morphology and microstructure of welding joints at the corresponding currents were observed in the experiment.The results show that the best condition is at an average current of 90 A and current difference of 40 A,when the maximum temperature is 200 °C higher than the fusion points,with the temperature difference of about 100 °C and stress change of 10 MPa between thermal pulse and thermal base.Under these conditions,Al alloy T-joint with proper fusion condition has smooth fish-scale welding appearance and finer microstructure.Furthermore,the thermal curves and stress distribution in the experiment are consistent with those in the simulation,verifying the precision of the welding simulation.
基金supported by National Natural Science Foundation of China(No.61473279)the National High-Tech Research and Development Program of China(863 Program)(No.2012AA040608)Equipment Development Programs of the Chinese Academy of Sciences(No.YZ201247)
文摘In this study, a stand-off and collinear double pulse laser-induced breakdown spectroscopy (DP LIBS) system was designed, and the magnesium alloy samples at a distance of 2.5 m away from the LIBS system were measured. The effect of inter-pulse delay on spectra was studied, and the signal enhancement was observed compared to the single pulse LIBS (SP LIBS). The morphology of the ablated crater on the sample indicated a higher efficiency of surface pretreatment in DP LIBS. The calibration curves of Ytterbium (Y) and Zirconium (Zr) were investigated. The square of the correlation coefficient of the calibration curve of element Y reached up to 0.9998.
基金supported by the National Basic Research Program of China(No.2013CB922200)the China Postdoctoral Science Foundation(No.2014M551169)National Natural Science Foundation of China(Nos.11674128,11474129 and 11504129)
文摘In this paper, we present a study on the effect of inter-pulse delay using femtosecond double-pulse laser-induced breakdown spectroscopy in a collinear geometry. The temporal evolution of spectral intensity is performed for the lines of Fe I 423.60 nm, Fe I 425.08 nm and Fe I 427.18 nm. It is found that, by selecting appropriate inter-pulse delay, the signal enhancement can be significantly increased compared with the single-pulse case. A three-fold enhancement in the current experiment is obtained. The plasma temperature and electron density are also investigated based on the theory of Boltzmann plot and Stark broadening. We attribute the main mechanism for emission enhancement to the plasma re-heating effect.
文摘New tungsten ion source is produced by using single and double-pulse laser ablation system. Combined collinear Nd:YAG laser beams(266+1064 nm) are optimized to focus on the sample in air. Optimization of the experimental parameters is achieved to enhance the signal-to-noise ratio of the emission spectra. The velocity distribution of the emitted plasma cloud is carefully measured. The influences of the potential difference between the bias electrodes, laser wavelength and intensity on the current signal are also studied. The results show that the increase in the tungsten ion velocity under the double-pulse lasers causes the output current signal to increase by about three folds. The electron density and temperature are calculated by using the Stark-broadened line profile of tungsten line and Boltzmann plot method of the upper energy levels, respectively. The signal intensity dependence of the tungsten ion angular distribution is also analyzed. The results indicate that the double-pulse laser ablation configuration is more potent technique for producing more metal ion source deposition, thin film formation, and activated plasma-facing component material.
基金financially supported by the National Natural Science Foundation of China(Nos.12274280,11774220 and 11974147)。
文摘We designed a femtosecond(fs)+picosecond(ps)double-pulse sequence by using a Mach-Zehnder-like apparatus to split a single 120 fs pulse into two sub-pulses,and one of them was stretched to a width of 2 ps by a four-pass grating system.Through observing the ripples induced on the ZnO surface,we found the ionization rate appeared to be higher for the sequence in which the fs pulse arrived first.The electron rate equation was used to calculate changes of electron density distribution for the sequences with different delay times.We suggest that using a temporally shaped fs+ps pulse sequence can achieve nonlinear ionization control and influence the induced ripples.
基金Acknowledgements This research work was financially supported by the National Natural Science Foundation China (Grant No. 61473279) and the National Key Research and Development Program of China (No. 2016YFF0102502).
文摘To monitor the components of molten magnesium alloy during the smelting process in real time and online, we designed a standoff double-pulse laser-induced breakdown spectroscopy (LIBS) analysis system that can perform focusing, collecting and imaging of long-range samples. First, we tested the system on solid standard magnesium alloy samples in the laboratory to establish a basis for the online monitoring of the components of molten magnesium alloy in the future. The experimental results show that the diameters of the focus spots are approximately 1 mm at a range of 3 m, the ablation depth of the double-pulse mode is much deeper than that of the single-pulse mode, the optimum interpulse delay of the double pulse is inconsistent at different ranges, and the spectral intensity decays rapidly as the range increases. In addition, the enhancement effect of the double pulse at 1.89 m is greater than that at 2.97 m, the maximum enhancement is 7.1-fold for the Y(I)550.35-nm line at 1.89 m, and the calibration results at 1.89 m are better than those at 2.97 m. At 1.89 m, the determination coefficients (R2) of the calibration curves are approximately 99% for Y, Pr, and Zr; the relative standard deviations (RSDs) are less than 10% for Y, Pr, and Zr; the root mean square errors (RMSEs) are less than 0.037% for Pr and Zr; the limits of detection (LODs) are less than 1000 ppm for Y, Pr, and Zr; and the LODs of Y, Pr, and Zr at 2.97 m are higher than those at 1.89 m. Additionally, we tested the system on molten magnesium alloy in a magnesium alloy plant. The calibration results of the liquid magnesium alloy are not as favorable as those of the sampling solid magnesium alloys. In particular, the RSDs of the liquid magnesium alloy are approximately 20% for Pr and La. However, with future improvements in the experimental conditions, the developed system is promising for the in situ analysis of molten magnesium alloy.
基金the CAS-TWAS president fellowship program of UCAS for financial assistancepartial support by the National Natural Science Foundation of China (NSFC), grants No. 11 474 079 and No. 11 421 063。
文摘In the photodetachment of atoms or negative ions by a double-pulse laser, the first pulse of the double-pulse laser generates waves and the delayed second pulse may detect them. The phenomenon of the excitation and detection of waves by a double-pulse laser can be used to identify the closed orbits in the system. We demonstrate this phenomenon with a negative hydrogen ion(H^-) by analyzing the total population excited by a double-pulse laser in a timedependent field for different physical parameters. By analyzing the total excited population using a double-pulse laser, we can uncover all the closed orbits existing in the system. We demonstrate that this can be realized by scanning the first pulse position and the time delay between the two pulses.
基金Projects(31665004,31715011) supported by the Open Fund of State Key Laboratory of Advanced Design and Manufacture for Vehicle Body,Hunan University,ChinaProject(15C0450) supported by the Educational Commission of Hunan Province of China
文摘Four different welding sequences of double-pulse MIG welding were conducted for 6061-T6 aluminum alloy automobile bumpers by using nonlinear elastoplasticity finite element method based on ABAQUS software.The post-welding residual stress and deformation were definitely different among the four welding sequences.The results showed that the highest temperature in Solution A was approximately 200℃higher than the melting point of base metal.High residual stress was resulted from this large temperature gradient and mainly concentrated on the welding vicinity between beam and crash box.The welding deformation primarily occurred in both of the contraction of two-ends of the beam and the self-contraction of crash box.Compared with other welding sequences,the residual stress in Solution A was the smallest,whereas the welding deformation was the largest.However,the optimal sequence was Solution B because of the effective reduction of residual stress and good assembly requirements.
基金Projects(2019JJ70077,2019JJ50510) supported by the National Science Foundation of Hunan Province,ChinaProject(31665004) supported by Open Fund of State Key Laboratory of Advanced Design and Manufacture for Vehicle Body,ChinaProjects(18B552,18B285) supported by Scientific Research Fund of Hunan Provincial Education Department,China
文摘6061 aluminum alloy T-joints were welded by double-pulsed MIG welding process. Then, the post-weld heat treatment was performed on the welded T-joints. The weld microstructure under different aging temperature and time was investigated by transmission electron microscopy and scanning electron microscopy. The mechanical properties were examined by hardness test and tensile test. The results showed that the micro-hardness was sensitive to heat treatment temperature and time. Increasing temperature was beneficial to the shortening of peak aging time. There were a large number of dislocations and few precipitates in the welded joints. With the increase of post-weld heat treatment temperature and time, the density of dislocation decreased. Meanwhile, the strengthening phase precipitated and grew up gradually. When the post-weld heat treatment temperature increased up to 200℃, large Q' phases were observed. And they were responsible for the peak value of the micro-hardness in the welded joints.
基金We are grateful for financial supports from the National Natural Science Foundation of China under Grant (No. 61605162) Singapore Maritime Institute under the research project Grant (No. SMI-2015-OF-10)+1 种基金 Natural Science Foundation of Fujian Province of China under Grant (No. 2017J05106) and Collaborative Innovation Center of High-End Equipment Manufacturing in Fujian.
文摘A novel spatial double-pulse laser ablation scheme is investigated to enhance the processing quality and efficiency fornanosecond laser ablation of silicon substrate. During the double-pulse laser ablation, two splitted laser beams simulta-neously irradiate on silicon surface at a tunable gap. The ablation quality and efficiency are evaluated by both scanning electron microscope and laser scanning confocal microscope. As tuning the gap distance, the ablation can be signifi-cantly enhanced if the spatial interaction between the two splitted laser pulses is optimized. The underlying physical mechanism for the interacting spatial double-pulse enhancement effect is attributed to the redistribution of the integratedenergy field, corresponding to the temperature field. This new method has great potential applications in laser microm-achining of functional devices at higher processing quality and faster speed.
基金supported by the National Natural Science Foundation of China(No.61403100)Fundamental Research Funds for the Central Universities(HIT.NSRIF.2015037)
文摘To make full use of expanded maneuverability and increased range,adaptive constrained on-board guidance technology is the key capability for a glide vehicle with a double-pulse rocket engine,especially under the requirements of desired target changing and on-line reconfigurable control and guidance.Based on the rapid footprint analysis,whether the new target is within the current footprint area is firstly judged.If not,the rocket engine ignites by the logic obtained from the analysis of optimal flight range by the method of hp-adaptive Gauss pseudospectral method(hp-GPM).Then,an on-board trajectory generation method based on powered quasi-equilibrium glide condition(QEGC)and linear quadratic regulator(LQR)method is used to guide the vehicle to the new target.The effectiveness of the guidance method consisted of powered on-board trajectory generation,LQR trajectory tracking,footprint calculation,and ignition time determination is indicated by some simulation examples.
文摘Wide bandgap(WBG)semiconductors,such as silicon carbide(SiC)and gallium nitride(GaN),exhibit superior physical properties and demonstrate great potential for replacing conventional silicon(Si)semiconductors with WBG technology,pushing the boundaries of power devices to handle higher blocking voltages,switching frequencies,output power levels,and operating temperatures.However,tradeoffs in switching performance and converter efficiency when substituting GaN devices for Si and SiC counterparts are not well-defined,especially in a cascode configuration.Additional research with further detailed investigation and analysis is necessitated for medium-voltage GaN devices in power converter applications.Therefore,the aim of this research is to experimentally investigate the impact of emerging 650/900 V cascode GaN devices on bidirectional dc-dc converters that are suitable for energy storage and distributed renewable energy systems.Dynamic characteristics of Si,SiC,and cascode GaN power devices are examined through the double-pulse test(DPT)circuit at different gate resistance values,device currents,and DC bus voltages.Furthermore,the switching behavior and energy loss as well as the rate of voltage and current changes over the time are studied and analyzed at various operating conditions.A 500 W experimental converter prototype is implemented to validate the benefits of cascode GaN devices on the converter operation and performance.Comprehensive analysis of the power losses and efficiency improvements for Si-based,SiC-based,and GaN-based converters are performed and evaluated as the switching frequency,working temperature,and output power level are in-creased.The experimental results reveal significant improvements in switching performance and energy efficiency from the emerging cascode GaN devices in the bidirectional converters.
文摘We propose a method to suppress deceptive jamming by frequency diverse array (FDA) in radar electronic coun- termeasure environments. FDA offers a new range-angle-dependent beam pattern through a small frequency increment across elements. Due to the coupling between the angle and range, a mismatch between the test angle and physical angle occurs when the slant range on which the beam focuses is not equal to the slant range of the real target. In addition, the range of the target can be extracted by sum-difference beam except for time-delay testing, because the beam provides a range resolution in the FDA that cannot be deceived by traditional deceptive jamming. A strategy of using FDA to transmit two pulses with zero and nonzero frequency increments, respectively, is proposed to ensure that the angle of a target can be obtained by FDA. Moreover, the lo- calization performance is examined by analyzing the Cramer-Rao lower bound and detection probability. Effectiveness of the proposed method is confirmed by simulation results.
基金This work was supported by the Beijing Natural Science Foundation(No.4192015)the National Natural Science Foundation of China(No.61975003).
文摘The dispersive Fourier transform technique provides feasibility of exploring non-repetitive events and the buildup process in ultrafast lasers.In this paper,we report a new buildup process of dissipative solitons in a simplified mode-locked Yb-doped fiber laser,which includes more complex physics stages such as the Q-switching stage,raised and damped relaxation oscillation stages,noise-like stage,successive soliton explosions stage,and soliton breathing stage.Complete evolution dynamics of noise-like pulse and double pulse are also investigated with dispersive Fourier transform.For the noise-like pulse dynamics process,it will only experience the Q-switching and relaxation oscillation stages.In the case of dissipative soliton and noise-like pulse,the double pulse buildup behavior is manifested as the replication of individual pulses.A weak energy migration occurs between two pulses before reaching steady state.Meanwhile,real-time mutual conversion of the dissipative soliton and noise-like pulse has been experimentally observed,which appears to be instantaneous without extra physical processes.To the best of our knowledge,this is the first report on these physical phenomena observed together in a mode-locked fiber laser.The results further enrich the dynamics of mode-locked fiber lasers and provide potential conditions for obtaining intelligent mode-locked lasers with controllable output.