The drag reducing effect of polymer additive aqueous solution was investigated in flow boiling, and the polymer additives were two kinds of polyacrylamide (PAM) with relative molecular mass about 2.56×10 6 and 8....The drag reducing effect of polymer additive aqueous solution was investigated in flow boiling, and the polymer additives were two kinds of polyacrylamide (PAM) with relative molecular mass about 2.56×10 6 and 8.55×10 6. The frictional pressure drop was calculated according to the measured total pressure drop. The results show that the flow drag of flow boiling is reduced by adding a small amount of PAM to water when heat flux is in the range of 15.1 kW·m -2 to 47.0 kW·m -2 , when the mass fraction of PAM is higher than 2.0×10 -5 , the drag reducing effect is obvious. Drag reducing effect of PAM, whose relative molecular mass is 8.55×10 6, is slightly better than that of 2.56×10 6 at the same mass fraction, and the greater the flow rate of the additive solution, the better the effect of the drag reduction.展开更多
The simplified momentum equations of the two-phase flow have been adopted as the basic assumptions in this study. For vessels of small diameter, the shear stress becomes important and the friction pressure drop propos...The simplified momentum equations of the two-phase flow have been adopted as the basic assumptions in this study. For vessels of small diameter, the shear stress becomes important and the friction pressure drop proposed by Ergun considers this effect by involving the wall effect. By replacing the Ergun pressure drop and the first order velocity term for particles drag model in the momentum equations, the relation for the drag coefficient versus the volume fraction is obtained. The calculus of variations is used with certain restriction for extremization of this drag coefficient. An analytical correlation for the drag coefficient is obtained depending on the volume fraction of “fluid particles”. The drag function obtained in previous studies does not match with the empirical data in the bed volume fraction range of [0.45 to 0.59]. Therefore, the function is modified and the results are better adjusted with the empirical data.展开更多
文摘The drag reducing effect of polymer additive aqueous solution was investigated in flow boiling, and the polymer additives were two kinds of polyacrylamide (PAM) with relative molecular mass about 2.56×10 6 and 8.55×10 6. The frictional pressure drop was calculated according to the measured total pressure drop. The results show that the flow drag of flow boiling is reduced by adding a small amount of PAM to water when heat flux is in the range of 15.1 kW·m -2 to 47.0 kW·m -2 , when the mass fraction of PAM is higher than 2.0×10 -5 , the drag reducing effect is obvious. Drag reducing effect of PAM, whose relative molecular mass is 8.55×10 6, is slightly better than that of 2.56×10 6 at the same mass fraction, and the greater the flow rate of the additive solution, the better the effect of the drag reduction.
文摘The simplified momentum equations of the two-phase flow have been adopted as the basic assumptions in this study. For vessels of small diameter, the shear stress becomes important and the friction pressure drop proposed by Ergun considers this effect by involving the wall effect. By replacing the Ergun pressure drop and the first order velocity term for particles drag model in the momentum equations, the relation for the drag coefficient versus the volume fraction is obtained. The calculus of variations is used with certain restriction for extremization of this drag coefficient. An analytical correlation for the drag coefficient is obtained depending on the volume fraction of “fluid particles”. The drag function obtained in previous studies does not match with the empirical data in the bed volume fraction range of [0.45 to 0.59]. Therefore, the function is modified and the results are better adjusted with the empirical data.