期刊文献+
共找到207篇文章
< 1 2 11 >
每页显示 20 50 100
Drug-coated balloon angioplasty for the treatment of intracranial arterial stenosis in a young stroke patient:A case report
1
作者 Peng-Cheng Zhu Ling-Feng Shu +3 位作者 Qing-Hai Dai Hong-Tu Tan Jia-Bin Wang Tao Wu 《World Journal of Clinical Cases》 SCIE 2024年第19期3956-3960,共5页
BACKGROUND Intracranial arterial narrowing is a significant factor leading to brief episodes of reduced blood flow to the brain,known as transient ischemic attacks,or fullblown strokes.While atherosclerosis is commonl... BACKGROUND Intracranial arterial narrowing is a significant factor leading to brief episodes of reduced blood flow to the brain,known as transient ischemic attacks,or fullblown strokes.While atherosclerosis is commonly associated with intracranial arterial narrowing,it is frequently of a non-atherosclerotic nature in younger patients.CASE SUMMARY Here,we present the case of a young stroke patient with narrowing of the middle cerebral artery(MCA),characterized as non-atherosclerotic lesions,who experienced an ischemic stroke despite receiving standard drug therapy.The patient underwent digital subtraction angiography(DSA)to assess the entire network of blood vessels in the brain,revealing significant narrowing(approximately 80%)in the M1 segment of the right MCA.Subsequently,the patient underwent Drug-Coated Balloon Angioplasty to treat the stenosis in the right MCA's M1 segment.Follow-up DSA confirmed the resolution of stenosis in this segment.Although the remaining branches showed satisfactory blood flow,the vessel wall exhibited irregularities.A review of DSA conducted six months later showed no evident stenosis in the right MCA,with a smooth vessel wall.CONCLUSION The use of drug-coated balloon angioplasty demonstrated favorable outcomes in repairing and reshaping the blood vessel wall in young patients.Therefore,it may be considered a promising treatment option for similar cases. 展开更多
关键词 Intracranial arterial stenosis Middle cerebral artery drug-coated balloon Young stroke Case report
下载PDF
The Efficacy and Safety of Drug-Coated Balloons in the Treatment of Acute Myocardial Infarction
2
作者 Mingliang Du Hui Hui 《World Journal of Cardiovascular Diseases》 CAS 2024年第1期1-9,共9页
The incidence of acute myocardial infarction (AMI) is increasing year by year, which seriously endangers human health around the world. The preferred treatment strategy for AMI patients is the use of drug-eluting sten... The incidence of acute myocardial infarction (AMI) is increasing year by year, which seriously endangers human health around the world. The preferred treatment strategy for AMI patients is the use of drug-eluting stents (DES), as there is ample evidence to suggest that stent implantation can reduce major adverse cardiovascular events (MACEs). With the application of drug-coated balloons (DCBs) and the enhancement of the concept of interventional without implantation, the question is whether DCBs can be safely and effectively used in patients with AMI? The purpose of this study was to investigate the safety and effectiveness of DCBs in the treatment of AMI. A retrospective review of clinical data was conducted on 55 AMI patients who underwent primary percutaneous coronary intervention (PCI) from January 2020 to December 2021. Of these patients, 25 were treated with DCBs and 30 were treated with DESs. Optical coherence tomography (OCT) was used to measure the minimum lumen diameter, lumen stenosis, and coronary artery dissection before and after surgery, and angina pectoris attacks and various MACEs were recorded at 1, 6, and 12 months after surgery. The results showed that there were no significant differences in clinical baseline data between the two groups. However, the minimum lumen diameter of the DCB group immediately after the operation was smaller than that of the DES group, and the stenosis degree of the lumen in the DCB group was higher than that in the DES group. The incidence of coronary artery dissection in the DCB group was significantly higher than that in the DES group, but the majority of them were type B. At 1, 6, and 12 months after treatment, there was no significant difference in the occurrence of MACEs between the two groups. In conclusion, DCBs is a safe and effective treatment for AMI. However, the incidence of coronary artery dissection in DCB patients is higher than that in DES patients, but the majority of them are type B. . 展开更多
关键词 Myocardial Infarction drug-coated Balloon Drug-Eluting Stents
下载PDF
A novel cerebrovascular drug-coated balloon catheter for treating symptomatic intracranial atherosclerotic stenosis lesions:Study protocol for a prospective,multicenter,single-arm,target-value clinical trial
3
作者 Qianhao Ding Wenbo Liu +10 位作者 Jingge Zhao Dehua Guo Yao Tang Tengfei Zhou Yanyan He Ferdinand K.Hui Yonghong Ding Liangfu Zhu Zilang Wang Yingkun He Tianxiao Li 《Journal of Interventional Medicine》 2023年第4期179-185,共7页
Background:Previous single-center studies have demonstrated that drug-coated balloons(DCBs)may reduce restenosis rates,which is an important factor affecting the prognosis for intracranial interventional therapy.Howev... Background:Previous single-center studies have demonstrated that drug-coated balloons(DCBs)may reduce restenosis rates,which is an important factor affecting the prognosis for intracranial interventional therapy.However,currently available cardiac DCBs are not always suitable for the treatment of intracranial atherosclerotic stenosis(ICAS).This study aimed to evaluate the safety and efficacy of a novel DCB catheter designed for patients with severely symptomatic ICAS.Methods:This prospective,multicenter,single-arm,target-value clinical trial was conducted in 9 Chinese stroke centers to evaluate the safety and efficacy of a novel DCB catheter for treating symptomatic severe ICAS.Primary metrics and other indicators were collected and analyzed using SAS version 9.4(SAS Institute,Cary,NC,USA).Results:A total of 155 patients were enrolled in this study.The preliminary collection of follow-up data has been completed,while data quality control is ongoing.Conclusion:Results of this study demonstrated the patency rate,safety,and effectiveness of a novel on-label paclitaxel DCB designed for the treatment of ICAS.Ethics and dissemination:This study,involving human participants,was reviewed and approved by the Ethics Committee of Drugs(Devices)Clinical Experiment at Henan Provincial People’s Hospital(reference number:2020-145-03)and other research centers participating in the clinical trial.The results of this study will be presented at international conferences and sent to peer-reviewed journals for publication.Standard protocol items:The Recommendations for Interventional Trials checklist was used when drafting the study protocol.Trial registration number:Registered with the Chinese Clinical Trial Registry on June 11,2021(Chi CTR2100047223). 展开更多
关键词 Intracranial arterial stenosis drug-coated balloon Ischemic stroke Transient ischemic attack Endovascular therapy
下载PDF
Drug-coated balloons for treating de novo lesions in large coronary vessels:A case report
4
作者 Zhi-Qiang Zhang Yi-Ran Qin +4 位作者 Man Yin Xue-Heng Chen Lei Chen Wen-Yan Liang Xi-Qing Wei 《World Journal of Clinical Cases》 SCIE 2023年第20期4920-4925,共6页
BACKGROUND Percutaneous transluminal coronary angioplasty,while an effective intervention,can frequently lead to acute occlusion with severe consequences.Although clinical trials have demonstrated the efficacy of drug... BACKGROUND Percutaneous transluminal coronary angioplasty,while an effective intervention,can frequently lead to acute occlusion with severe consequences.Although clinical trials have demonstrated the efficacy of drug-coated balloons(DCB)in treating acute coronary artery occlusion and in preventing restenosis,there has been limited exploration on the use of DCB in treating de novo lesions in large vessels.Currently,DCB are only recommended for patients with small vessel lesions and in-stent restenosis lesions,those at high risk of bleeding,and other special groups of patients.CASE SUMMARY This report presents a case of successful drug-coated balloon treatment of de novo lesions in large coronary vessels.Postoperatively,the patient demonstrated favorable recovery,with subsequent examination results revealing no significant differences from the previous examination.CONCLUSION The successful treatment of the patient in our case highlights the potential of DCB in the treatment of de novo lesions in large coronary vessels. 展开更多
关键词 drug-coated balloons De novo lesions Large coronary vessels Coronary artery disease Percutaneous coronary intervention Case report
下载PDF
Restenosis of a drug eluting stent on the previous bioresorbable vascular scaffold successfully treated with a drug-coated balloon: A case report 被引量:2
5
作者 Hyun Gyung Jang Kyehwan Kim +4 位作者 Hyun Woong Park Jin-Sin Koh Young-Hoon Jeong Jeong Rang Park MinGyu Kang 《World Journal of Clinical Cases》 SCIE 2021年第3期758-763,共6页
BACKGROUND The in-stent restenosis(ISR)rates are reportedly inconsistent despite the increased use of second-generation drug eluting stent(DES).Although bioresorbable vascular scaffold(BVS)have substantial advantages ... BACKGROUND The in-stent restenosis(ISR)rates are reportedly inconsistent despite the increased use of second-generation drug eluting stent(DES).Although bioresorbable vascular scaffold(BVS)have substantial advantages with respect to vascular restoration,the rate of scaffold thrombosis is higher with BVS than with DES.Optimal treatment strategies have not been established for DES-ISR to date.CASE SUMMARY We report on a case of a 60-year-old man patient with acute coronary syndrome.He had a history of ST-segment elevation myocardial infarction associated with very late scaffold thrombosis and treated with a DES.Coronary angiography revealed significant stenosis,suggesting DES-ISR on the previous BVS.Optical coherence tomography(OCT)identified a plaque rupture and a disrupted scaffold strut in the neointimal proliferation of DES.To treat the DES-ISR on the previous BVS,we opted for a drug-coated balloon(DCB)after a balloon angioplasty using a semi-compliant and non-compliant balloon.The patient did not experience adverse cardiovascular events on using a DCB following the use of intensive dual antiplatelet therapy and statin for 24 mo.CONCLUSION This case highlights the importance of OCT as an imaging modality for characterizing the mechanism of target lesion failure.The use of a DCB following the administration of optimal pharmacologic therapy may be an optimal strategy for the treatment and prevention of recurrent BVS thrombosis and DES-ISR. 展开更多
关键词 Bioresorbable vascular scaffold thrombosis In-stent restenosis drug-coated balloon Optical coherence tomography Intensive dual antiplatelet therapy Case report
下载PDF
A Case Summary of the Application of a Drug-eluting Stent Combined with a Drug-Coated Balloon in Left Main Coronary Artery Disease
6
作者 Rong-Xue Xiao Xu wang +1 位作者 Jun-Qing Gao Zong-Jun Liu 《Cardiovascular Innovations and Applications》 2022年第1期127-134,共8页
Objective:To evaluate the clinical efficacy of a drug-eluting stent(DES)combined with a drug-coated balloon(DCB)in the treatment of left main coronary artery bifurcation lesions.Methods:A retrospective analysis was co... Objective:To evaluate the clinical efficacy of a drug-eluting stent(DES)combined with a drug-coated balloon(DCB)in the treatment of left main coronary artery bifurcation lesions.Methods:A retrospective analysis was conducted on the clinical data of eight patients with left main coronary artery bifurcation lesions treated with a DES combined with a DCB who were admitted to our hospital from July 2016 to July 2017.These eight patients all underwent DES treatment for their left main coronary artery and left anterior descending coronary artery lesions,and DCB treatment at the ostium of the left circumflex artery;six of the patients underwent surgical procedures under the guidance of intravascular ultrasonography.Immediate postoperative angiography was used to evaluate the patency of the diseased vessels,and the restenosis rate at the 6-month follow-up after the operation and the incidence of serious clinical events within 6 months were assessed as well.Results:The use of a DES combined with a DCB in the treatment of left main coronary artery bifurcation lesions had a low restenosis rate(left main coronary artery(8.4±5.3)%,left anterior descending coronary artery(18.2±5.0)%,left circumflex artery(30.5±16.5)%).No serious clinical events occurred in any patients.Conclusion:A DES combined with a DCB is a safe and effective interventional treatment for left main artery coro-nary bifurcation lesions. 展开更多
关键词 Left main coronary artery bifurcation lesions drug-coated balloon drug-eluting stent
下载PDF
基于预处理的Ballon模型及在眼疲劳检测中的应用 被引量:1
7
作者 邢益良 张荣国 +1 位作者 邵永波 刘焜 《计算机工程与设计》 CSCD 北大核心 2009年第21期4980-4983,共4页
获取眼睛轮廓和眼球轮廓对进一步研究人眼疲劳状态具有重要意义。提出基于预处理的Ballon模型对含有双眼的局部人脸图片进行人眼和眼球检测的方法。用微分算法抽取边缘、标识出物体、使用几何特性识别人眼区域,自动获取主动轮廓所需要... 获取眼睛轮廓和眼球轮廓对进一步研究人眼疲劳状态具有重要意义。提出基于预处理的Ballon模型对含有双眼的局部人脸图片进行人眼和眼球检测的方法。用微分算法抽取边缘、标识出物体、使用几何特性识别人眼区域,自动获取主动轮廓所需要的眼睛初始轮廓;使用提出的基于预处理的Ballon模型收敛人眼;结合数学形态等方法收敛到眼球。实验结果表明,该方法具有效果好、鲁棒性好、受光线影响弱等优点。 展开更多
关键词 SNAKE模型 疲劳驾驶 边缘轮廓 眼睛检测 ballon模型
下载PDF
某系留气球整流罩热适应性设计
8
作者 王军 《西安航空学院学报》 2024年第1期37-40,共4页
整流罩是系留气球重要组成部分,其内部环境受工作海拔高度、太阳辐射以及任务设备热耗等诸多因素影响。本文以某系留气球为对象,采用整流罩壁面传热和整流罩壁面传热+强迫通风两种不同的设计方案,在不同工作高度下对该系留气球整流罩的... 整流罩是系留气球重要组成部分,其内部环境受工作海拔高度、太阳辐射以及任务设备热耗等诸多因素影响。本文以某系留气球为对象,采用整流罩壁面传热和整流罩壁面传热+强迫通风两种不同的设计方案,在不同工作高度下对该系留气球整流罩的工作环境温度进行仿真分析。结果表明,采用整流罩壁面传热+强迫通风方案,送风风量为3 000 m^(3)·h^(-1)可满足不同高度下整流罩内部环控温度需求,该方案在实践中已得到成功应用。 展开更多
关键词 系留气球 整流罩 热设计
下载PDF
冲击波血管内碎石术治疗冠状动脉钙化病变有效性和安全性分析
9
作者 张紫微 白洁 +4 位作者 郑甲林 唐炯 杨帮国 蔡文峰 齐峰 《介入放射学杂志》 CSCD 北大核心 2024年第4期363-367,共5页
目的探讨冲击波球囊血管内碎石术(IVL)在冠状动脉钙化病变中应用的安全性和有效性。方法研究对象为2022年8月至2023年4月在云南省阜外心血管病医院接受介入治疗的50例中重度冠状动脉钙化病变患者,其中各25例分别采用Shockwave球囊IVL、... 目的探讨冲击波球囊血管内碎石术(IVL)在冠状动脉钙化病变中应用的安全性和有效性。方法研究对象为2022年8月至2023年4月在云南省阜外心血管病医院接受介入治疗的50例中重度冠状动脉钙化病变患者,其中各25例分别采用Shockwave球囊IVL、临床常规介入方法治疗。血管内超声导引手术操作,评估钙化病变特征及术后支架膨胀率。观察记录围手术期并发症发生率。结果IVL治疗组术后患者最狭窄处支架膨胀率显著高于非IVL治疗组[(82.6±8.2)%比(76.4±11.2)%,P=0.030],手术时间更短[(78.6±30.8)min比(102.9±37.5)min,P=0.016],发生非Q波性心肌梗死患者更少(5例比12例,P=0.037),均未发生慢血流、无复流、冠状动脉穿孔、急性支架内血栓等并发症。结论冲击波球囊IVL治疗中重度冠状动脉钙化病变安全有效,可显著改善支架膨胀率,降低并发症发生率。 展开更多
关键词 钙化病变 冲击波球囊 血管内碎石术 经皮冠状动脉介入治疗
下载PDF
影像引导下经皮半月节球囊压迫术治疗原发性三叉神经痛50例分析 被引量:1
10
作者 罗似亮 张明亮 +4 位作者 吾太华 侯浩波 李春苗 邓少勇 马赞 《临床神经外科杂志》 2023年第5期566-568,574,共4页
目的探讨数字化减影血管造影(DSA)引导下经皮半月节球囊压迫术治疗原发性三叉神经痛的临床疗效。方法回顾性分析暨南大学医学院附属脑科医院2019年1月—2021年10月在DSA引导下行经皮半月节球囊压迫术治疗并有效随访的50例原发性三叉神... 目的探讨数字化减影血管造影(DSA)引导下经皮半月节球囊压迫术治疗原发性三叉神经痛的临床疗效。方法回顾性分析暨南大学医学院附属脑科医院2019年1月—2021年10月在DSA引导下行经皮半月节球囊压迫术治疗并有效随访的50例原发性三叉神经痛患者临床及随访资料。对性别、年龄、病程、患侧、球囊形态、面部麻木程度、疼痛复发和疗效的关系进行统计学分析。结果术后疼痛即刻缓解率100%。随访期间9例疼痛复发,短期复发率18.0%;治愈44例,治愈率88.0%;显效3例、有效1例、无效2例,有效率96.0%。患者年龄、性别、患侧、病程、球囊形态与疗效的差异无统计学意义(P>0.05)。面部麻木程度、疼痛复发与疗效差异有统计学意义(P<0.05)。结论DSA引导下经皮半月节球囊压迫术治疗原发性三叉神经痛微创、有效。术后面部麻木程度≤Ⅱ分和疼痛复发是影响临床疗效的两个主要因素。 展开更多
关键词 三叉神经痛 球囊压迫 DSA 疗效
下载PDF
美国FDA MAUDE数据库气管插管不良事件相关数据的分析 被引量:1
11
作者 夏兵 岳中胜 +3 位作者 王丽 王新茹 马雪皎 刘伟 《中国药事》 CAS 2023年第4期480-488,共9页
目的:分析呼吸机用气管插管不良事件相关数据,探讨影响气管插管安全性相关因素,为临床合理及安全使用气管插管提出建议。方法:检索美国FDA MAUDE数据库,对2019-2021年间3777例气管插管不良事件报告进行统计分析。结果:气管插管不良事件... 目的:分析呼吸机用气管插管不良事件相关数据,探讨影响气管插管安全性相关因素,为临床合理及安全使用气管插管提出建议。方法:检索美国FDA MAUDE数据库,对2019-2021年间3777例气管插管不良事件报告进行统计分析。结果:气管插管不良事件器械故障方面主要表现为气囊问题、连接问题、导管问题和标签问题等;患者伤害方面主要表现为非计划性拔管、缺氧/低血氧饱和度和呼吸功能问题等。结论:通过分析美国FDA MAUDE数据库中2019-2021年气管插管不良事件发生原因,建议我国气管插管生产企业应积极主动开展不良事件监测工作,加强对气管插管的质量管控,落实企业主体责任;使用单位应严格执行气管插管术操作规范,熟练掌握插管技术,特别警惕呼吸机与气管插管配合使用进行机械通气所产生的风险;监管部门应加强监督检查和开展医疗器械不良事件培训工作。 展开更多
关键词 气管插管 气囊问题 非计划性拔管 不良事件 FDA MAUDE数据库
下载PDF
C-臂引导下经皮穿刺球囊压迫术治疗原发性三叉神经痛的疗效分析 被引量:2
12
作者 邓少勇 罗似亮 +5 位作者 吾太华 张明亮 侯浩波 许锡镇 马赞 代小程 《中国临床神经外科杂志》 2023年第6期372-374,共3页
目的探讨C-臂引导下经皮球囊压迫术(PBC)治疗原发性三叉神经痛(PTN)的疗效。方法回顾性分析2018年8月到2021年12月PBC治疗的49例PTN的临床资料。结果49例手术时间平均(75.71±30.33)min;住院时间平均(3.78±1.12)d。术中球囊呈... 目的探讨C-臂引导下经皮球囊压迫术(PBC)治疗原发性三叉神经痛(PTN)的疗效。方法回顾性分析2018年8月到2021年12月PBC治疗的49例PTN的临床资料。结果49例手术时间平均(75.71±30.33)min;住院时间平均(3.78±1.12)d。术中球囊呈“梨形”43例、椭圆形5例、哑铃型1例;充盈体积0.3~1.0 ml,平均(0.59±0.16)ml。术后疼痛即刻缓解为100%。术后随访4~44个月,平均(21.18±11.60)个月;末次随访显示,治愈39例,显效4例,有效2例,无效4例;治愈率79.6%,总体有效率为91.8%。随访期间9例复发,复发率为18.4%。术中球囊呈梨形病人治愈率(88.4%,38/43)明显高于术中球囊呈其他形态的病人(16.7%,1/6;P<0.05)。术后出现面部麻木病人的治愈率(88.6%,39/44)明显高于未出现面部麻木的病人(0%;P<0.05)。结论PBC治疗PTN的近期疗效显著,术中球囊呈“梨形”和术后出现面部麻木提示病人可获得良好疗效。 展开更多
关键词 原发性三叉神经痛 经皮穿刺球囊压迫术 C-臂引导 疗效
下载PDF
Drug-coated balloon-only strategy for percutaneous coronary intervention of de novo left main coronary artery disease: the importance of proper lesion preparation
13
作者 Sanna Uskela Antti Eranti +1 位作者 Jussi MKärkkäinen Tuomas TRissanen 《Frontiers of Medicine》 SCIE CSCD 2023年第1期75-84,共10页
This retrospective single-center registry study included all consecutive patients who underwent percutaneous coronary intervention (PCI) for a de novo left main coronary artery lesion using drug coated-balloon (DCB)-o... This retrospective single-center registry study included all consecutive patients who underwent percutaneous coronary intervention (PCI) for a de novo left main coronary artery lesion using drug coated-balloon (DCB)-only strategy between August 2011 and December 2018. To best of our knowledge, no previous studies of DCB-only strategy of treating de novo left main coronary artery disease, exist. The primary endpoint was major adverse cardiovascular events (MACEs) including cardiac death, non-fatal myocardial infarction, and target lesion revascularization (TLR). The cohort was divided into two groups depending on weather the lesion preparation was done according to the international consensus group guidelines. Sixty-six patients (mean age 75±8.6, 72% male), 52% of whom had acute coronary syndrome, underwent left main PCI with the DCB-only strategy. No procedural mortality and no acute closures of the treated left main occurred. At 12 months, MACE and TLR occurred in 24% and 6% of the whole cohort, respectively. If the lesion preparation was done according to the guidelines, the MACE and TLR rates were 21.2% and 1.9%. Left main PCI with the DCB only-strategy is safe leading to acceptable MACE and low TLR rates at one year, if the lesion preparation is done according to the guidelines. 展开更多
关键词 drug-coated balloon left main high bleeding risk predilatation calcifield lesion percutaneous coronary intervention
原文传递
毛冬青甲素对兔颈总动脉球囊损伤后炎性因子IL-6和M-CSF的影响 被引量:17
14
作者 赵利华 李章伟 +1 位作者 杨闯 姜亚秋 《吉林大学学报(医学版)》 CAS CSCD 北大核心 2008年第1期105-107,138,共4页
目的:观察毛冬青甲素(Ilexonin,IA)对兔颈总动脉球囊损伤后炎性因子IL-6、M-CSF的影响,为冠脉内介入治疗提供实验依据。方法:日本大耳白兔30只,高胆固醇饲料喂养4周后随机分为3组(每组10只):对照组,右颈外动脉切开后直接缝合切口;球囊... 目的:观察毛冬青甲素(Ilexonin,IA)对兔颈总动脉球囊损伤后炎性因子IL-6、M-CSF的影响,为冠脉内介入治疗提供实验依据。方法:日本大耳白兔30只,高胆固醇饲料喂养4周后随机分为3组(每组10只):对照组,右颈外动脉切开后直接缝合切口;球囊扩张组,右颈外动脉切开并内膜球囊损伤后缝合动脉与伤口;IA治疗组,操作同球囊扩张组,缝合切口后静脉给予IA。三组实验兔继续高胆固醇饮食4周。术前1d,术后1d、1周、2周、4周采集血清,放免法测定白细胞介素-6(IL-6)、巨噬细胞集落刺激因子(M-CSF)。取损伤血管段,病理观察动脉病理改变。结果:①球囊扩张组术后血清IL-6水平明显高于IA治疗组(P<0.05),且较IA治疗组恢复延迟;②IA治疗组术后血清M-CSF水平虽增高,但低于球囊扩张组(P<0.05),且恢复术前血清水平时间也较球囊扩张组明显提前(P<0.05);③血管内皮病理变化:颈动脉损伤后对照组内膜光滑,未见泡沫细胞;球囊扩张组内膜增厚,血管平滑肌细胞增生,可见较多泡沫细胞,管腔狭窄;IA治疗组较球囊扩张组泡沫细胞减少,管腔狭窄程度明显减轻。结论:IA能降低动脉内膜球囊损伤后炎性因子IL-6、血清M-CSF水平,并抑制被损伤内膜血管平滑肌细胞增生。 展开更多
关键词 毛冬青甲素 炎性因子IL-6 M-CSF 球囊损伤
下载PDF
足月妊娠促宫颈成熟方法的探讨 被引量:39
15
作者 薛洪喜 马玉燕 +4 位作者 李桦 马丽娟 高凌雪 刘锡梅 宋佳伦 《现代妇产科进展》 CSCD 北大核心 2007年第9期647-649,共3页
目的:评价目前常用的足月妊娠促宫颈成熟方法的效果,为足月妊娠促宫颈成熟和引产提供有效、安全、方便的方法。方法:选择有引产指征的足月妊娠产妇221例,随机分为水囊组(A)80例,缩宫素组(B)45例,米索前列醇组(C)46例,普贝生组(D)50例,比... 目的:评价目前常用的足月妊娠促宫颈成熟方法的效果,为足月妊娠促宫颈成熟和引产提供有效、安全、方便的方法。方法:选择有引产指征的足月妊娠产妇221例,随机分为水囊组(A)80例,缩宫素组(B)45例,米索前列醇组(C)46例,普贝生组(D)50例,比较4组产妇的宫颈评分、分娩结局、新生儿结局和副作用。结果:水囊组促宫颈成熟效果最好,显著高于其他各组(P<0.05),剖宫产率低于其他各组(P<0.05)。普贝生组用药至临产时间及总产程明显短于其他各组(P<0.05)。各组新生儿窒息发生率和羊水污染率无显著差异。普贝生组发生子宫过度刺激症状者较多。结论:低位水囊有显著的促宫颈成熟的作用,配伍缩宫素在足月妊娠促宫颈成熟和引产过程中有效,普贝生促宫颈成熟安全有效,可选择性地用于有一定经济条件的孕妇。 展开更多
关键词 妊娠末期 宫颈成熟 水囊引产
下载PDF
羊膜球囊在宫腔粘连电切术后的临床应用 被引量:15
16
作者 刘丹 哈春芳 +1 位作者 徐泽荣 刘培淑 《实用妇产科杂志》 CAS CSCD 北大核心 2015年第10期780-784,共5页
目的:从临床应用的安全性、有效性评价羊膜作为生物支架在宫腔粘连(IUA)电切术(TCRA)后放置于宫腔预防再粘连、促进宫腔内膜化的价值。方法:经宫腔镜检查确诊为中重度IUA且随访资料完整的患者47例,按照随机的原则分为宫腔镜下TCRA后Fole... 目的:从临床应用的安全性、有效性评价羊膜作为生物支架在宫腔粘连(IUA)电切术(TCRA)后放置于宫腔预防再粘连、促进宫腔内膜化的价值。方法:经宫腔镜检查确诊为中重度IUA且随访资料完整的患者47例,按照随机的原则分为宫腔镜下TCRA后Foley球囊组(21例)、宫腔镜下TCRA后羊膜球囊组(26例)。记录宫腔镜下TCRA术中并发症、术中出血量、手术时间、膨宫液用量以及TCRA术后发热、盆腔VAS评分、术后阴道流血时间,术后球囊脱落脱落情况、月经恢复情况;术后宫腔深度的改善、IUA评分改善、IUA再发情况以及宫腔内膜覆盖满意程度,并随访术后妊娠情况。结果:两组术中术后各项指标比较差异均无统计学意义(P>0.05)。羊膜球囊组术后IUA评分降低较Foley球囊组有显著优势,分别降低4.02±0.31分与2.51±0.52分(P<0.05);月经恢复正常比例更高,分别为80.7%与52.4%(P<0.05);宫腔再粘连率较Foley球囊组明显降低,分别为3.8%与42.9%(P<0.05);宫腔内膜化满意程度高于Foley球囊组,满意率分别为88.4%与47.6%(P<0.05)。总妊娠率为25.5%(12/47),羊膜球囊组(34.6%,9/26)高于Foley球囊组(14.3%,3/21),差异无统计学意义(P>0.05)。结论:羊膜在TCRA后放置宫腔起到生物支架作用,在降低再粘连率、IUA评分及宫腔内膜化满意程度方面有较好效果,临床应用安全。 展开更多
关键词 宫腔粘连 羊膜球囊 生物支架 Foley球囊
下载PDF
血栓抽吸联合替罗非班对急性ST段抬高型心肌梗死患者心肌再灌注及预后的影响研究 被引量:28
17
作者 赵良平 徐卫亭 +5 位作者 陈建昌 肖飞 邵春来 李晖 江建良 罗小雨 《中国全科医学》 CAS CSCD 北大核心 2015年第27期3284-3289,共6页
目的评估血栓抽吸联合替罗非班对急性ST段抬高型心肌梗死(STEMI)患者早期经皮冠状动脉介入(PCI)术后心肌再灌注及预后的影响。方法连续选取2008年1月—2013年1月于苏州大学附属第二医院就诊的急性STEMI患者456例,采用随机数字表法分为:... 目的评估血栓抽吸联合替罗非班对急性ST段抬高型心肌梗死(STEMI)患者早期经皮冠状动脉介入(PCI)术后心肌再灌注及预后的影响。方法连续选取2008年1月—2013年1月于苏州大学附属第二医院就诊的急性STEMI患者456例,采用随机数字表法分为:单纯PCI组(对照组)140例;血栓抽吸组168例;血栓抽吸+替罗非班组148例。比较各组PCI术后心肌梗死溶栓试验(TIMI)心肌再灌注(TMP)分级、校正的TIMI帧数(CTFC)、术后1个月和术后12个月主要不良心脏事件(MACE)发生情况。采用多因素Logistic回归分析急性STEMI患者术后1个月和术后12个月发生MACE的影响因素。结果 3组患者梗死血管和病变血管支数比较,差异均无统计学意义(P>0.05);3组患者PCI术后TMP分级及药物洗脱支架使用率比较,差异均有统计学意义(P<0.05)。对照组CTFC为(31.5±5.8),血栓抽吸组为(21.8±7.2),血栓抽吸+替罗非班组为(20.9±6.3),3组比较差异有统计学意义(F=5.176,P=0.006);其中血栓抽吸组、血栓抽吸+替罗非班组CTFC低于对照组(q=3.225、3.734,P<0.001)。多因素Logistic回归分析结果显示,糖尿病、血肌酐水平、左心室射血分数与急性STEMI患者术后1个月发生MACE有回归关系(P<0.05);年龄、血肌酐水平、左心室射血分数、治疗方法与急性STEMI患者术后12个月发生MACE有回归关系(P<0.05)。结论血栓抽吸联合替罗非班能明显改善急性STEMI患者早期PCI术后心肌再灌注水平,降低急性STEMI患者PCI术后12个月MACE发生率。 展开更多
关键词 心肌梗死 血栓抽吸 替罗非班 血管成形术 气囊 冠状动脉 心肌再灌注 预后
下载PDF
避免膜周部室间隔缺损经导管封堵术发生心律失常的临床探讨 被引量:7
18
作者 何学华 龙湘党 +4 位作者 李云 赵学辉 刘丽萍 李文娟 方亦兵 《临床儿科杂志》 CAS CSCD 北大核心 2009年第10期983-986,共4页
目的通过分析膜周部室间隔缺损(perimenbranous ventricular septal defects,PMVSD)封堵治疗术前、术中和术后发生心律失常的情况,探讨介入治疗发生心律失常的相关影响因素,以期降低术后心律失常的发生率。方法分析2005年11月至2008年1... 目的通过分析膜周部室间隔缺损(perimenbranous ventricular septal defects,PMVSD)封堵治疗术前、术中和术后发生心律失常的情况,探讨介入治疗发生心律失常的相关影响因素,以期降低术后心律失常的发生率。方法分析2005年11月至2008年1月行封堵治疗的65例先心病室间隔缺损患者封堵术前、术中和术后心律失常的发生率、类型及其可能的相关因素。结果65例室间隔缺损患者术前有7例心律失常,表现为不完全或完全性右束支阻滞(IRBBB或CRBBB)、左前分支阻滞(LAH)等。术中可见多种类型的心律失常,其中在导丝和输送鞘通过室间隔时多出现房室传导阻滞(AVB)、交界性逸博、室性早博、室内差异性传导、室性心动过速等。术后心律失常发生率为12.3%(8/65),分别为Ⅰ度房室传导阻滞2例,ILBBB1例,LAH1例,IRBBB3例,室性早博1例,与术中的心律失常情况有一定的关系。术前已存在的7例心律失常经封堵治疗后,有1例Ⅰ度房室传导阻滞合并左前分支阻滞,其余无变化,随访未出现新的心律失常。对封堵术后心律失常影响因素进行单因素分析,提示与封堵器大小、缺损距三尖瓣隔瓣、主动脉右冠瓣距离、术中动-静脉轨道建立时间、术中是否出现Ⅱ度或Ⅲ度房室传导阻滞密切相关。结论临床选择VSD封堵器直径≤8cm、缺损距主动脉右冠瓣和三尖瓣隔瓣距离≥3cm的患者进行封堵治疗,可减少术后心律失常的发生率;术中建立轨道时间长短及有无发生Ⅱ度AVB和(或)Ⅲ度AVB,也是影响术后发生心律失常的重要因素。临床在把握介入治疗适应证的同时,重视PMVSD与传导系统的空间位置,避免选择过大的封堵器用于治疗,缩短手术时间,注意手术过程心电变化的提示作用,是降低PMVSD封堵术后发生严重心律失常的有效措施。 展开更多
关键词 室间隔缺损 心律失常 封堵术
下载PDF
玻璃微球敏化乳化炸药爆速特性 被引量:8
19
作者 宋锦泉 汪旭光 +1 位作者 于亚伦 崔安娜 《北京科技大学学报》 EI CAS CSCD 北大核心 2000年第6期497-500,574,共5页
建立了乳化炸药实验室制备工艺,并自制了玻璃微球敏化的乳化炸药试样.通过对试样的爆速测试,研究了乳化炸药爆速与其密度及玻璃微球含量等因素的关系,分析了这种工业炸药爆速的特点.结果表明:这种乳化炸药的爆速随其密度的增大而... 建立了乳化炸药实验室制备工艺,并自制了玻璃微球敏化的乳化炸药试样.通过对试样的爆速测试,研究了乳化炸药爆速与其密度及玻璃微球含量等因素的关系,分析了这种工业炸药爆速的特点.结果表明:这种乳化炸药的爆速随其密度的增大而增大到最大值后逐渐降低,直到被压死. 展开更多
关键词 爆速 乳化炸药 玻璃微球
下载PDF
优化绿色通道对ST段抬高型心肌梗死直接经皮冠状动脉介入治疗的影响 被引量:22
20
作者 唐聚花 刘青 +1 位作者 李娜 李芝明 《中国全科医学》 CAS CSCD 北大核心 2016年第36期4499-4503,共5页
背景心血管疾病是严重威胁广大人民群众健康的疾病,每年全世界约有1 670万人死于心血管疾病。在我国,冠状动脉粥样硬化性心脏病(CAHD)也是威胁人民群众健康的首要心血管疾病,每年约有70万人死于CAHD。CAHD的治疗方法中,针对ST段抬高型... 背景心血管疾病是严重威胁广大人民群众健康的疾病,每年全世界约有1 670万人死于心血管疾病。在我国,冠状动脉粥样硬化性心脏病(CAHD)也是威胁人民群众健康的首要心血管疾病,每年约有70万人死于CAHD。CAHD的治疗方法中,针对ST段抬高型心肌梗死(STEMI)的治疗手段主要是直接经皮冠状动脉介入治疗(PCI)。目的分析优化绿色通道对STEMI患者直接PCI延迟时间及预后的影响,为临床工作者对STEMI急诊救治工作提供理论依据。方法选取2013—2014年于郑州人民医院通过优化后绿色通道行直接PCI的符合纳入标准的STEMI患者117例为试验组。回顾性选取2011—2012年于郑州人民医院通过优化前绿色通道行直接PCI的符合纳入标准的STEMI患者107例为对照组。记录患者一般资料、延迟时间〔患者出现症状到报警时间、120接警时间、指派急救站时间、接受任务到出诊时间、出诊到抵达现场时间、现场到首次医疗接触时间、首次医疗接触到首份心电图时间、首次医疗接触到口服双抗药物(阿司匹林肠溶片300 mg、氯吡格雷600 mg)时间、急诊医师初步告知病情到患者理解时间、院前远程会诊及导管室预激活时间、待诊专科医师二次告知并签字时间、入导管室到球囊扩张时间、进门到球囊扩张时间(D2B)〕、预后因素〔TIMI心肌灌注分级(TMP)、30 d病死率、PCI后严重不良心血管事件(心力衰竭、心律失常、心源性休克、复流后再梗死)发生率〕。结果试验组患者出现症状到报警时间、120接警时间、指派急救站时间、首次医疗接触到首份心电图时间、首次医疗接触到口服双抗药物时间、待诊专科医师二次告知并签字时间、D2B短于对照组,急诊医师初步告知病情到患者理解时间、院前远程会诊及导管室预激活时间长于对照组(P<0.05);两组接受任务到出诊时间、出诊到抵达现场时间、现场到首次医疗接触时间、入导管室到球囊扩张时间比较,差异无统计学意义(P>0.05)。试验组TMP高于对照组,30 d病死率、心力衰竭发生率、心律失常发生率、心源性休克发生率、复流后再梗死发生率低于对照组(P<0.05)。结论优化绿色通道可缩短STEMI患者直接PCI延迟时间,并改善患者预后。 展开更多
关键词 心肌梗死 血管成形术 气囊 冠状动脉 急救 绿色通道 延迟 预后
下载PDF
上一页 1 2 11 下一页 到第
使用帮助 返回顶部