In this paper, the characteristics of an atmospheric pressure helium plasma jet generated by a dual-power electrode (DPE) configuration are investigated by using a two-dimensional fluid model. The effect of a needle...In this paper, the characteristics of an atmospheric pressure helium plasma jet generated by a dual-power electrode (DPE) configuration are investigated by using a two-dimensional fluid model. The effect of a needle electrode on the discharge is studied by comparing the results of the DPE configuration with those of the single ring electrode configuration. It is found that the existence of the needle leads to the generation of a helium plasma jet with a higher propagation velocity, higher species density, and larger discharge width. Furthermore, the influences of the needle radius and needle-to-ring discharge gap on the generation of a plasma jet are also studied. The simulation results indicate that the needle electrode has an evident influence on the plasma jet characteristics.展开更多
Electroslag casting with parallel fixed-movable dual electrodes is a new method for achieving better quality of castings in complex mold cavities.In this work,a mathematical model,y=kx^2+(k+1)x,was established to desc...Electroslag casting with parallel fixed-movable dual electrodes is a new method for achieving better quality of castings in complex mold cavities.In this work,a mathematical model,y=kx^2+(k+1)x,was established to describe the ideal correlation between the current ratio(y)and the cross-sectional area ratio(x)of the dual electrodes,where k is the filling ratio.Investigation was conducted on the electroslag casting process with dual electrodes of various cross-sectional areas,but at a constant k value.The experimental results indicated that the ideal correlation was obtained at the stable casting stage,and the fitting results were consistent with the experimental results at certain k values.The experimental findings show that better castings can be obtained when the current ratio is greater than 1.536 and the cross-sectional area ratio is greater than 0.5.展开更多
Based on the single biasing electrode experiments to optimize the confinement of plasma in the device of KT-5C tokamak, dual-biasing electrodes were inserted into the KT5C plasma for the first time to explore the enha...Based on the single biasing electrode experiments to optimize the confinement of plasma in the device of KT-5C tokamak, dual-biasing electrodes were inserted into the KT5C plasma for the first time to explore the enhancing effects of biasing and the mechanisms of the biasing. By means of applying different combinations of biasing voltages onto the dual electrodes, the changes of Er, which are the key factor for boosting up the Er × B flow shear, were observed. The time evolution showed that the inner electrode played a major role in dual-biasing, which drew larger current than the outer one. The outer electrode produced little influence. It turned out that the dual-biasing electrodes were as effective as a single one in improving the plasma confinement, for the mechanism of biasing was essentially an edge effect.展开更多
A unique method for preparing a coaxial dual-microelectrode sensor by vaporizing the nano-thickness Au layer on the DNA modified carbon fiber micro-column electrode was illustrated. The dual-electrode showed particula...A unique method for preparing a coaxial dual-microelectrode sensor by vaporizing the nano-thickness Au layer on the DNA modified carbon fiber micro-column electrode was illustrated. The dual-electrode showed particular merit for determination in biological systems.展开更多
A new type of dual-electrode and multi-channel electrochemical detection technology for capillary electrophoresis is described in this paper. Two detectors(the amperometric detector and the conductometric detector) or...A new type of dual-electrode and multi-channel electrochemical detection technology for capillary electrophoresis is described in this paper. Two detectors(the amperometric detector and the conductometric detector) or two conductometric detectors are connected to the same capillary electrophoresis system. The whole system possesses the advantages of the two electrochemical detectors including sparing time, improving the analytical speed and expanding the sample range. The working electrode and detector cell are handled easily. The system was applied to sample detection with satisfactory results.展开更多
Dual-electrode capacitively coupled plasma discharges are investigated here to lower the non-uniformity of plasma density. The dual-electrode structure proposed by Jung splits the electrode region and increases the fl...Dual-electrode capacitively coupled plasma discharges are investigated here to lower the non-uniformity of plasma density. The dual-electrode structure proposed by Jung splits the electrode region and increases the flexibility of fine tuning non-uniformity. Different RF voltages,frequencies, phase-shifts and electrode areas are simulated and the influences are discussed. RF voltage and electrode area have a non-monotonic effect on non-uniformity, while frequency has a monotonic effect. Phase-shift has a cyclical influence on non-uniformity. A special combination of 224 V voltage and 11% area ratio with 10 MHz lowers the non-uniformity of the original set(200 V voltage and 0% area ratio with 10 MHz) by 46.5%. The position of the plasma density peak at the probe line has been tracked and properly tuning the phase-shift can obtain the same trace as tuning frequency or voltage.展开更多
The sulfide-based solid-state electrolytes(SEs)reactivity toward moisture and Li-metal are huge barriers that impede their large-scale manufactu ring and applications in all-solid-state lithium batteries(ASSLBs).Herei...The sulfide-based solid-state electrolytes(SEs)reactivity toward moisture and Li-metal are huge barriers that impede their large-scale manufactu ring and applications in all-solid-state lithium batteries(ASSLBs).Herein,we proposed an Al and O dual-doped strategy for Li_(3)PS_(4)SE to regulate the chemical/electrochemical stability of anionic PS_(4)^(3-)tetrahedra to mitigate structural hydrolysis and parasitic reactions at the SE/Li interface.The optimized Li_(3.08)A_(10.04)P_(0.96)S_(3.92)O_(0.08)SE presents the highestσLi+of 3.27 mS cm^(-1),which is~6.8 times higher than the pristine Li_(3)PS_(4)and excellently inhibits the structural hydrolysis for~25 min@25%humidity at RT.DFT calculations confirmed that the enhanced chemical stability was revealed to the intrinsically stable entities,e.g.,POS33-units.Moreover,Li_(3.08)Al_(0.04)P_(0.96)S_(3.92)O_(0.08)SE cycled stably in Li//Li symmetric cell over 1000 h@0.1 mA cm^(-2)/0.1 mA h cm^(-2),could be revealed to Li-Al alloy and Li_(2)Oat SE/Li interface impeding the growth of Li-dendrites during cycling.Resultantly,LNO@LCO/Li_(3.08)Al_(0.04)P_(0.96)S_(3.92)O_(0.08)/Li-In cell delivered initial discharge capacities of 129.8 mA h g^(-1)and 83.74%capacity retention over 300 cycles@0.2 C at RT.Moreover,the Li_(3.08)Al_(0.04)P_(0.96)S_(3.92)O_(0.08)SE presented>90%capacity retention over 200 and 300 cycles when the cell was tested with LiNi_(0.8)Co_(0.15)Al_(0.05)O_(2)(NCA)cathode material vs.5 and 10 mg cm^(-2)@RT.展开更多
In dual-ion batteries (DIBs), energy storage is achieved by intercalation/de-intercalation of both cations and anions. Due to the mismatch between ion diameter and layer space of active materials, however, volume expa...In dual-ion batteries (DIBs), energy storage is achieved by intercalation/de-intercalation of both cations and anions. Due to the mismatch between ion diameter and layer space of active materials, however, volume expansion and exfoliation always occur for electrode materials. Herein, an integrated electrode Co3O4/carbon fiber paper (CFP) is prepared as the anode of DIB. As the Co3O4 nanosheets grow on CFP substrate vertically, it promotes the immersion of electrolyte and shortens the pathway for ionic transport. Besides, the strong interaction between Co3O4 and CFP substrate reduces the possibility of sheet exfoliation. An integrated-electrode-based DIB is therefore packaged using Co3O4/CFP as anode and graphite as cathode. As a result, a high energy density of 72 Wh/kg is achieved at a power density of 150 W/kg. The design of integrated electrode provides a new route for the development of high-performance DIBs.展开更多
The aim of this paper is to study the behaviour of bipolar corona with a dual parallel corona bar and a metallic plate. The experimental results show that under otherwise identical conditions, the discharge depends st...The aim of this paper is to study the behaviour of bipolar corona with a dual parallel corona bar and a metallic plate. The experimental results show that under otherwise identical conditions, the discharge depends strongly on the electrode separation between the bars. By investigating various separations, the corona regime can be divided into three regions: independent, shunted, and shorted. The criterion for eliminating electrostatic charge without over compensation is also given.展开更多
Application of parallel and serial dual electrode detectors for capillary electrophoresis was first described. In parallel dual electrode approach, two 100 μm-diameter Cu disks arranged side by side were used as the ...Application of parallel and serial dual electrode detectors for capillary electrophoresis was first described. In parallel dual electrode approach, two 100 μm-diameter Cu disks arranged side by side were used as the dual working electrode for the simultaneous determination of a mixture of carbohydrates and amino acids. In serial dual electrode approach, two working electrodes were arranged in a disk-ring manner for the simultaneous determination of both cysteine and cystine; the disk electrode was Hg/Au serving as the upstream electrode, the ring electrode was 5% CoPC carbon paste serving aa the downstream electrode.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant Nos.10775026,11275042,11305026,and 11405042)
文摘In this paper, the characteristics of an atmospheric pressure helium plasma jet generated by a dual-power electrode (DPE) configuration are investigated by using a two-dimensional fluid model. The effect of a needle electrode on the discharge is studied by comparing the results of the DPE configuration with those of the single ring electrode configuration. It is found that the existence of the needle leads to the generation of a helium plasma jet with a higher propagation velocity, higher species density, and larger discharge width. Furthermore, the influences of the needle radius and needle-to-ring discharge gap on the generation of a plasma jet are also studied. The simulation results indicate that the needle electrode has an evident influence on the plasma jet characteristics.
文摘Electroslag casting with parallel fixed-movable dual electrodes is a new method for achieving better quality of castings in complex mold cavities.In this work,a mathematical model,y=kx^2+(k+1)x,was established to describe the ideal correlation between the current ratio(y)and the cross-sectional area ratio(x)of the dual electrodes,where k is the filling ratio.Investigation was conducted on the electroslag casting process with dual electrodes of various cross-sectional areas,but at a constant k value.The experimental results indicated that the ideal correlation was obtained at the stable casting stage,and the fitting results were consistent with the experimental results at certain k values.The experimental findings show that better castings can be obtained when the current ratio is greater than 1.536 and the cross-sectional area ratio is greater than 0.5.
基金supported by the Chinese Ministry of Education,the Chinese National Natural Science Foundation(Grant Nos.1023 5010 and 1033 5060)grants from the Chinese Academy of Sciences and by the JSPS-CAS Core University Program in the field of Plasma and Nuclear Fusion.
文摘Based on the single biasing electrode experiments to optimize the confinement of plasma in the device of KT-5C tokamak, dual-biasing electrodes were inserted into the KT5C plasma for the first time to explore the enhancing effects of biasing and the mechanisms of the biasing. By means of applying different combinations of biasing voltages onto the dual electrodes, the changes of Er, which are the key factor for boosting up the Er × B flow shear, were observed. The time evolution showed that the inner electrode played a major role in dual-biasing, which drew larger current than the outer one. The outer electrode produced little influence. It turned out that the dual-biasing electrodes were as effective as a single one in improving the plasma confinement, for the mechanism of biasing was essentially an edge effect.
基金The financial support from the NNSFC(No.20173054)is gratefully acknowledged.
文摘A unique method for preparing a coaxial dual-microelectrode sensor by vaporizing the nano-thickness Au layer on the DNA modified carbon fiber micro-column electrode was illustrated. The dual-electrode showed particular merit for determination in biological systems.
文摘A new type of dual-electrode and multi-channel electrochemical detection technology for capillary electrophoresis is described in this paper. Two detectors(the amperometric detector and the conductometric detector) or two conductometric detectors are connected to the same capillary electrophoresis system. The whole system possesses the advantages of the two electrochemical detectors including sparing time, improving the analytical speed and expanding the sample range. The working electrode and detector cell are handled easily. The system was applied to sample detection with satisfactory results.
基金supported by National Natural Science Foundation of China(No.51405261)
文摘Dual-electrode capacitively coupled plasma discharges are investigated here to lower the non-uniformity of plasma density. The dual-electrode structure proposed by Jung splits the electrode region and increases the flexibility of fine tuning non-uniformity. Different RF voltages,frequencies, phase-shifts and electrode areas are simulated and the influences are discussed. RF voltage and electrode area have a non-monotonic effect on non-uniformity, while frequency has a monotonic effect. Phase-shift has a cyclical influence on non-uniformity. A special combination of 224 V voltage and 11% area ratio with 10 MHz lowers the non-uniformity of the original set(200 V voltage and 0% area ratio with 10 MHz) by 46.5%. The position of the plasma density peak at the probe line has been tracked and properly tuning the phase-shift can obtain the same trace as tuning frequency or voltage.
基金supported by the National Natural Science Foundation of China(Nos.21203008,21975025,12274025)the Hainan Province Science and Technology Special Fund(Nos.ZDYF2021SHFZ232,ZDYF2023GXJS022)the Hainan Province Postdoctoral Science Foundation(No.300333)。
文摘The sulfide-based solid-state electrolytes(SEs)reactivity toward moisture and Li-metal are huge barriers that impede their large-scale manufactu ring and applications in all-solid-state lithium batteries(ASSLBs).Herein,we proposed an Al and O dual-doped strategy for Li_(3)PS_(4)SE to regulate the chemical/electrochemical stability of anionic PS_(4)^(3-)tetrahedra to mitigate structural hydrolysis and parasitic reactions at the SE/Li interface.The optimized Li_(3.08)A_(10.04)P_(0.96)S_(3.92)O_(0.08)SE presents the highestσLi+of 3.27 mS cm^(-1),which is~6.8 times higher than the pristine Li_(3)PS_(4)and excellently inhibits the structural hydrolysis for~25 min@25%humidity at RT.DFT calculations confirmed that the enhanced chemical stability was revealed to the intrinsically stable entities,e.g.,POS33-units.Moreover,Li_(3.08)Al_(0.04)P_(0.96)S_(3.92)O_(0.08)SE cycled stably in Li//Li symmetric cell over 1000 h@0.1 mA cm^(-2)/0.1 mA h cm^(-2),could be revealed to Li-Al alloy and Li_(2)Oat SE/Li interface impeding the growth of Li-dendrites during cycling.Resultantly,LNO@LCO/Li_(3.08)Al_(0.04)P_(0.96)S_(3.92)O_(0.08)/Li-In cell delivered initial discharge capacities of 129.8 mA h g^(-1)and 83.74%capacity retention over 300 cycles@0.2 C at RT.Moreover,the Li_(3.08)Al_(0.04)P_(0.96)S_(3.92)O_(0.08)SE presented>90%capacity retention over 200 and 300 cycles when the cell was tested with LiNi_(0.8)Co_(0.15)Al_(0.05)O_(2)(NCA)cathode material vs.5 and 10 mg cm^(-2)@RT.
基金Supports from the National Natural Science Foundation of China (51872115 and 51802110)the National Key R&D Program of China (2016YFA0200400)+2 种基金the Jilin Province/Jilin University Co-construction Project-Funds for New Materials (SXGJSF20173, Branch-2/440050316A36)the Program for JLU Science and Technology Innovative Research Team (JLUSTIRT, 2017TD-09)“Double-First Class” Discipline for Materials Science & Engineering, are greatly acknowledged
文摘In dual-ion batteries (DIBs), energy storage is achieved by intercalation/de-intercalation of both cations and anions. Due to the mismatch between ion diameter and layer space of active materials, however, volume expansion and exfoliation always occur for electrode materials. Herein, an integrated electrode Co3O4/carbon fiber paper (CFP) is prepared as the anode of DIB. As the Co3O4 nanosheets grow on CFP substrate vertically, it promotes the immersion of electrolyte and shortens the pathway for ionic transport. Besides, the strong interaction between Co3O4 and CFP substrate reduces the possibility of sheet exfoliation. An integrated-electrode-based DIB is therefore packaged using Co3O4/CFP as anode and graphite as cathode. As a result, a high energy density of 72 Wh/kg is achieved at a power density of 150 W/kg. The design of integrated electrode provides a new route for the development of high-performance DIBs.
文摘The aim of this paper is to study the behaviour of bipolar corona with a dual parallel corona bar and a metallic plate. The experimental results show that under otherwise identical conditions, the discharge depends strongly on the electrode separation between the bars. By investigating various separations, the corona regime can be divided into three regions: independent, shunted, and shorted. The criterion for eliminating electrostatic charge without over compensation is also given.
基金financially supported by the National Natural Science Foundation of China(22168025)the Natural Science Foundation of Jiangxi Province(20192BAB203013,20202ACB L203003)+1 种基金CAS-Commonwealth Scientific and Industrial Research Organization(CSIRO)Joint Research Projects(121835KYSB20200039)the Joint Fund of the Yulin University and the Dalian National Laboratory for Clean Energy(Grant.YLU-DNL Fund 2021011)。
文摘Application of parallel and serial dual electrode detectors for capillary electrophoresis was first described. In parallel dual electrode approach, two 100 μm-diameter Cu disks arranged side by side were used as the dual working electrode for the simultaneous determination of a mixture of carbohydrates and amino acids. In serial dual electrode approach, two working electrodes were arranged in a disk-ring manner for the simultaneous determination of both cysteine and cystine; the disk electrode was Hg/Au serving as the upstream electrode, the ring electrode was 5% CoPC carbon paste serving aa the downstream electrode.