To examine accuracy of body composition predicted by the Multi-Frequency Bioelectric Impedance Analysis (MF-BIA) compared with the Dual-energy X-ray Absorptiometry (DXA) in adults with obese. We measured body comp...To examine accuracy of body composition predicted by the Multi-Frequency Bioelectric Impedance Analysis (MF-BIA) compared with the Dual-energy X-ray Absorptiometry (DXA) in adults with obese. We measured body composition of 749 adults with obese both by the MF-BIA and DXA. The Lin's concordance correlation and the Bland-Altman plots were used to examine the consistency. The concordance correlation coefficient of %BF between the MF-BIA and DXA in men and women was 0.560, and 0.669, respectively. Compared with the DXA, the MF-BIA significantly underestimated %BF by 4.33% in men (P 〈 0.001), however overestimated %BF by 0.50% in women (P 〈 0.001). After corrected by the correction equations established in this study, the differences were significantly decreased. Therefore, the MF-BIA (TANITA MC-180) may need to be corrected in estimating body composition for adults with obese.展开更多
近年来,我国肉类加工行业发展迅猛,自动化和智能化水平逐渐提高,多种肥瘦比例检测技术被应用到肉制品加工和屠宰行业。双能X射线吸收法(dual energy X-ray absorptiometry,DXA)是解决肉制品在线肥瘦比例检测的最佳方法之一,具有精准度...近年来,我国肉类加工行业发展迅猛,自动化和智能化水平逐渐提高,多种肥瘦比例检测技术被应用到肉制品加工和屠宰行业。双能X射线吸收法(dual energy X-ray absorptiometry,DXA)是解决肉制品在线肥瘦比例检测的最佳方法之一,具有精准度高、耗时短、可以对胴体全身进行检测的优势。本文比较当前各种肥瘦比例检测技术的特点,介绍DXA的概念、测量方式,重点探讨DXA在肥瘦比例测定中的应用和研究进展,通过对研究现状、设备类型和存在问题的分析,讨论未来该技术应用的发展方向。展开更多
Background The performance of computed tomography X-ray absorptiometry (CTXA) against the dual energy X-ray absorptiometry (DXA) as standard has not been studied in Chinese population. The aim of this study was to...Background The performance of computed tomography X-ray absorptiometry (CTXA) against the dual energy X-ray absorptiometry (DXA) as standard has not been studied in Chinese population. The aim of this study was to evaluate the precision of this measurement and validate the value of quantitative computed tomography (QCT) by comparing CTXA results with DXA results in an elderly Chinese population. Methods One hundred and three females of 46 to 76 years old and 49 males of 52 to 76 years old were recruited from the Prospective Urban Rural Epidemiology study. All subjects underwent hip scans by both QCT and DXA on the same day. For precision determination, 30 subjects had duplicate DXA hip scans. The hip QCT data of a subset of 27 subjects were separately analyzed by two observers and reanalyzed by one observer at a different time. The inter- and intra-observer variations of CTXA measurement were assessed, and the difference and correlation between CTXA and DXA results were analyzed. Results The inter- and intra-observer variations of CTXA were 0.070 and 0.024 g/cm^2 in the femoral neck (FN), and 0.030 and 0.012 g/cm2 in the total hip (TH), which were comparable to the DXA inter-scan variations (0.013 g/cm2 for FN and 0.014 g/cm2 for TH). The results of CTXA bone mineral density (BMD) were highly correlated with those of DXA (R2 = 0.810 for FN and R2 = 0.878 for TH). The BMD values of CTXA in FN and TH were lower than those of DXA by 21.0% and 17.8% (P〈0.05), respectively. However, after appropriate transformation, the difference was eliminated and a comparable T score could be obtained. Conclusions CTXA shows good agreement with DXA for the measurement of BMD in the proximal femur, which makes QCT suitable for the quantification of bone mineral content in the hip and helpful for the diagnosis of osteoporosis.展开更多
文摘To examine accuracy of body composition predicted by the Multi-Frequency Bioelectric Impedance Analysis (MF-BIA) compared with the Dual-energy X-ray Absorptiometry (DXA) in adults with obese. We measured body composition of 749 adults with obese both by the MF-BIA and DXA. The Lin's concordance correlation and the Bland-Altman plots were used to examine the consistency. The concordance correlation coefficient of %BF between the MF-BIA and DXA in men and women was 0.560, and 0.669, respectively. Compared with the DXA, the MF-BIA significantly underestimated %BF by 4.33% in men (P 〈 0.001), however overestimated %BF by 0.50% in women (P 〈 0.001). After corrected by the correction equations established in this study, the differences were significantly decreased. Therefore, the MF-BIA (TANITA MC-180) may need to be corrected in estimating body composition for adults with obese.
文摘近年来,我国肉类加工行业发展迅猛,自动化和智能化水平逐渐提高,多种肥瘦比例检测技术被应用到肉制品加工和屠宰行业。双能X射线吸收法(dual energy X-ray absorptiometry,DXA)是解决肉制品在线肥瘦比例检测的最佳方法之一,具有精准度高、耗时短、可以对胴体全身进行检测的优势。本文比较当前各种肥瘦比例检测技术的特点,介绍DXA的概念、测量方式,重点探讨DXA在肥瘦比例测定中的应用和研究进展,通过对研究现状、设备类型和存在问题的分析,讨论未来该技术应用的发展方向。
文摘Background The performance of computed tomography X-ray absorptiometry (CTXA) against the dual energy X-ray absorptiometry (DXA) as standard has not been studied in Chinese population. The aim of this study was to evaluate the precision of this measurement and validate the value of quantitative computed tomography (QCT) by comparing CTXA results with DXA results in an elderly Chinese population. Methods One hundred and three females of 46 to 76 years old and 49 males of 52 to 76 years old were recruited from the Prospective Urban Rural Epidemiology study. All subjects underwent hip scans by both QCT and DXA on the same day. For precision determination, 30 subjects had duplicate DXA hip scans. The hip QCT data of a subset of 27 subjects were separately analyzed by two observers and reanalyzed by one observer at a different time. The inter- and intra-observer variations of CTXA measurement were assessed, and the difference and correlation between CTXA and DXA results were analyzed. Results The inter- and intra-observer variations of CTXA were 0.070 and 0.024 g/cm^2 in the femoral neck (FN), and 0.030 and 0.012 g/cm2 in the total hip (TH), which were comparable to the DXA inter-scan variations (0.013 g/cm2 for FN and 0.014 g/cm2 for TH). The results of CTXA bone mineral density (BMD) were highly correlated with those of DXA (R2 = 0.810 for FN and R2 = 0.878 for TH). The BMD values of CTXA in FN and TH were lower than those of DXA by 21.0% and 17.8% (P〈0.05), respectively. However, after appropriate transformation, the difference was eliminated and a comparable T score could be obtained. Conclusions CTXA shows good agreement with DXA for the measurement of BMD in the proximal femur, which makes QCT suitable for the quantification of bone mineral content in the hip and helpful for the diagnosis of osteoporosis.