期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Analyses of risk factors and prognosis for new-onset atrial fibrillation in elderly patients after dual-chamber pacemaker implantation 被引量:5
1
作者 Xiao-Li CHEN Xue-Jun REN +3 位作者 Zhuo LIANG Zhi-Hong HAN Tao ZHANG Zhi LUO 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2018年第10期628-633,共6页
Objective To retrospectively identify risk factors and the prognosis for new-onset atrial fibrillation (AF)after implantation of dual-chamber pacemakers in elderly patients.Methods Consecutive patients aged >65year... Objective To retrospectively identify risk factors and the prognosis for new-onset atrial fibrillation (AF)after implantation of dual-chamber pacemakers in elderly patients.Methods Consecutive patients aged >65years who underwent their first implantation of a dual-chamber permanent pacemaker in Beijing Anzhen Hospital from October 2013to May 2016were enrolled.Their complete program- ming and follow-up data were recorded.Follow-up end points included new-onset AF and major adverse cardiovascular and cerebrovascular events.Restdts Altogether,322patients were enrolled,with new-onset AF observed in 79(24.5%)during their follow-up.Multivariable analysis identified four independent predictors of new-onset AF in elderly patients after pacemaker implantation:hypertension (HR =3.040, 95%CI:1.09-3.05,P =0.00),age (HR =1.966,95%CI:1.57-3.68,P =0.01);left atrial enlargement (HR =1.645,95%CI:1.05-1.25,P = 0.03);high ventricular pacing rate (HR =1.137,95%CI:1.01-1.06,P =0.01).Univariable analysis indicated that the CHA2DS2-VASc score was also a risk factor for AF (HR =1.368,95%CI:1.178-1.589,P =0.002),whereas multivariable regression analysis did not. Kaplan-Meier survival analysis showed that the risk for ischemic stroke was significantly higher in the new-onset AF group than in the non-AF group (P <0.05).Conclusion Hypertension,age,left atrial enlargement,and high ventricular pacing rate were independent predictors of new-onset AF in elderly patients after implantation of a permanent pacemaker.New-onset AF increased the risk for ischemic stroke. 展开更多
关键词 ATRIAL FIBRILLATION dual-chamber PACEMAKER Elderly Ischernic stroke
下载PDF
DYNAMIC BEHAVIOR ANALYSIS FOR LANDING-GEAR WITH DIFFERENT TYPES OF DUAL-CHAMBER SHOCK-STRUTS 被引量:10
2
作者 Nie Hong Qiao Xin +1 位作者 Gao Zejun Zhou Lanqin 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 1991年第2期235-244,共10页
In this paper three types of dual- chamber shock- struts are considered in dynamic analyses of landing-gear behavior during impact and taxi. Their dynamic characteristics are compared with each other according to calc... In this paper three types of dual- chamber shock- struts are considered in dynamic analyses of landing-gear behavior during impact and taxi. Their dynamic characteristics are compared with each other according to calculation results, and some conclusions are presented.It is very helpful for selecting a suitable type of dual-chamber shock-strut in landing-gear design. 展开更多
关键词 DYNAMIC BEHAVIOR ANALYSIS FOR LANDING-GEAR WITH DIFFERENT TYPES OF dual-chamber SHOCK-STRUTS
下载PDF
缓慢型心律失常心脏起搏患者心电监护拔牙的临床经验 被引量:4
3
作者 丁志雄 郑德源 顾章愉 《中国口腔颌面外科杂志》 CAS 2009年第6期559-561,共3页
目的:探讨安装心脏起搏器的严重缓慢型心律失常患者心电监护下拔牙的可行性。方法:在良好的局部麻醉和拔牙过程中密切观察心率、血压及动态心电变化的条件下,对12例伴有严重缓慢型心律失常且已安装心脏起搏器的患者进行拔牙,拔除患牙21... 目的:探讨安装心脏起搏器的严重缓慢型心律失常患者心电监护下拔牙的可行性。方法:在良好的局部麻醉和拔牙过程中密切观察心率、血压及动态心电变化的条件下,对12例伴有严重缓慢型心律失常且已安装心脏起搏器的患者进行拔牙,拔除患牙21颗。结果:12例患者均顺利完成拔牙手术,未发现任何并发症。结论:部分安装心脏起搏器的严重缓慢型心律失常患者在心电监护下可以安全拔牙。 展开更多
关键词 缓慢型心律失常 心脏起搏器 心电监护 拔牙
下载PDF
房室间期自动搜索功能起搏器对病窦综合征患者预后的影响 被引量:4
4
作者 史晓静 王高频 陶贵周 《中国心脏起搏与心电生理杂志》 2012年第3期218-220,共3页
目的观察自动AV间期搜索功能双腔起搏器减少心室起搏的有效性及对心功能和快速房性心律失常的影响。方法 100例植入DDD/R起搏器的患者(有AV搜索功能50例,无AV搜索功能50例),术后1年内程控获取右室起搏百分比、高频心房事件、检查超声心... 目的观察自动AV间期搜索功能双腔起搏器减少心室起搏的有效性及对心功能和快速房性心律失常的影响。方法 100例植入DDD/R起搏器的患者(有AV搜索功能50例,无AV搜索功能50例),术后1年内程控获取右室起搏百分比、高频心房事件、检查超声心动图及测试血浆心房利钠肽(ANP)值。结果有AV搜索功能组术后3,6,12个月右室起搏百分比明显小于无AV搜索功能组(18.7%±5.6%vs 82.4%±10.2%,19.8%±6.6%vs 77.3%±9.5%,18.4%±7.3%vs 79.2%±8.6%,P均<0.05)。有AV搜索功能组左室舒张末内径、左房内径、左室射血分数均明显改善(P均<0.05);ANP水平明显降低(203.10±28.20 pg/ml vs 298.80±31.50 pg/ml,P<0.05);高频心房事件也显著减少(18±9次vs 39±11次,P<0.05)。结论有AV搜索功能起搏器明显减少病窦综合征患者右室起搏比例,改善心功能,并减少高频心房事件。 展开更多
关键词 心血管病学 双腔起搏器 自动房室间期搜索 随访 右室起搏比例 心房利钠肽
下载PDF
Permanent transvenous pacemaker implantation in a patient with Cor triatriatum dextrum 被引量:1
5
作者 Kun Xiang George V Moukarbel Blair Grubb 《World Journal of Cardiology》 CAS 2015年第1期43-46,共4页
Cor triatriatum dextrum is an extremely rare congenital heart abnormality in which the right atrium is separatedinto two chambers by a persistent fibrous membrane. A transvenous approach to place a dual-chamber pacema... Cor triatriatum dextrum is an extremely rare congenital heart abnormality in which the right atrium is separatedinto two chambers by a persistent fibrous membrane. A transvenous approach to place a dual-chamber pacemaker in such patients is technically challenging. We report the first case of a transvenous permanent pacemaker placement in a patient with cor triatriatum dextrum. An 87-year-old woman was diagnosed with paroxysmal atrial fibrillation. She was accidentally found to have cor triatriatum dextrum during the transesophageal echocardiography(TEE) prior to cardioversion. Later during her hospital stay, it was indicated to place a permanant pacemaker due to high grade atrioventricular block. After thorough reviewing TEE imagings, a transvenous catheter-based approach was decided feasible. Patient successfully received a dual chamber pacemaker through left subclavian venous approach. Furthermore in our case, using specially designed pacemaker leads and cautious intra-procedural maneuvering under fluoroscopic guidance ensured procedural success. In summary, a thorough pre-operative evaluation with transesophageal echocardiography is critical for the planning and eventual success of the transvenous placement of rightsided leads. 展开更多
关键词 CONGENITAL HEART defect Complete HEART block Inter-atrial membrane dual-chamber PACEMAKER
下载PDF
Performance of Sewage Sludge Treatment and Electricity Generation by Different Configuration Microbial Fuel Cells
6
作者 Jun-Qiu Jiang Kun Wang +3 位作者 Xue-Xuan Peng Qing-Liang Zhao Yun-Shu Zhang Xiu-Dong Zhou 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2013年第4期1-6,共6页
This paper compared the degradation efficiency of sludge organic matters and electric-production by two typical microbial fuel cells——dual-chamber microbial fuel cell(DMFC)and single chamber air cathode microbial fu... This paper compared the degradation efficiency of sludge organic matters and electric-production by two typical microbial fuel cells——dual-chamber microbial fuel cell(DMFC)and single chamber air cathode microbial fuel cell(SAMFC),and the variations of sludge protein,polysaccharide and ammonia nitrogen within the systems were also investigated.The results showed that the concentration of sludge soluble chemical oxygen demand,protein and carbohydrate of DMFC are higher than these of SAMFC during the systems operation,while DMFC can achieve a better ammonia nitrogen removal than SAMFC.Under the same operation condition,the stable voltage output of DMFC and SAMFC is 0.61 V and 0.37 V;the maximum power density of DMFC and SAMFC is 2.79 W/m3and 1.25 W/m3;TCOD removal efficiency of DMFC and SAMFC is 34.14%and 28.63%for 12 d,respectively.Meanwhile,DMFC has a higher coulomb efficiency than SAMFC,but both are less than5%.The results showed that DMFC present a better performance on sludge degradation and electric-production. 展开更多
关键词 sewage sludge dual-chamber microbial fuel cell(DMFC) single chamber air cathode microbial fuel cell(SAMFC) DEGRADATION electricity production
下载PDF
Experimental research of a novel vortex generator for solar absorption chiller
7
作者 WANG Yan YU Jian MA ChongFang 《Science China(Technological Sciences)》 SCIE EI CAS 2009年第6期1793-1798,共6页
In this study, a novel generator for the single-effect LiBr-H2O absorption chiller using solar energy was investigated. A dual-chamber vortex generator (DCVG) consisted of a lower chamber and an upper chamber. The hot... In this study, a novel generator for the single-effect LiBr-H2O absorption chiller using solar energy was investigated. A dual-chamber vortex generator (DCVG) consisted of a lower chamber and an upper chamber. The hot weak LiBr-H2O liquid entered the lower chamber tangentially through a small nozzle to create a strong vortex flow. Due to the rotating flow, the pressure was reduced toward the central portion of the lower chamber. Experiments were conducted under different solution flow rates and temperatures. The experimental results showed that the lower pressure developed in the lower chamber could reduce the saturated temperature and help the evaporation in the generator that is more heat could be utilized to generate more refrigerant vapor. When the inlet temperature was 90°C, the COP of a solar absorption chiller using the DCVG could reach 0.83, which was higher than of the conventional absorption chiller by 22%. 展开更多
关键词 dual-chamber VORTEX GENERATOR ABSORPTION CHILLER SOLAR
原文传递
上一页 1 下一页 到第