Acquisition of physical data with high precision is a key step in reverse engineering (RE). It is an important stimulative for the progress of reverse engineering with which various digitizing devices are invent ed,...Acquisition of physical data with high precision is a key step in reverse engineering (RE). It is an important stimulative for the progress of reverse engineering with which various digitizing devices are invent ed, developed and made applicable. This paper introduces a three dimensional opt ical measurement method based on digital fringe projection technique in RE to im prove the technique through its application. A practical example is presented an d the result demonstrates the applicability and feasibility of the measurement s ystem as well as the reliability and validity of relevant methods and algorithms .展开更多
For industrial computed tomography systems, generation II scan mode has a large field of view but time consuming and generation III has a small field of view but fast. In order to realize the rapid ICT test of large ...For industrial computed tomography systems, generation II scan mode has a large field of view but time consuming and generation III has a small field of view but fast. In order to realize the rapid ICT test of large objects, a scan mode based on generation III called large field of view scan was discussed and its reconstruction algorithm based on FBP was deduced. The validity of the algorithm was verified by the results of computer simulation and experiments. Analysis showed that the effective scan field of view could be improved by more than 90% compared with that of generation III.展开更多
Objective To evaluate the feasibility of using gadopentetate dimeglumine(Gd-DTPA)for dual-energy computed tomography pulmonary angiography(CTPA).Methods Sixty-six patients were randomly divided into three groups and u...Objective To evaluate the feasibility of using gadopentetate dimeglumine(Gd-DTPA)for dual-energy computed tomography pulmonary angiography(CTPA).Methods Sixty-six patients were randomly divided into three groups and underwent CTPA.Group A had a turbo flash scan using an iohexol injection,Group B had a turbo flash scan using Gd-DTPA,and Group C had a dual-energy scan using Gd-DTPA.The original images of Group C were linearly blended with a blending factor of 0.5 or reconstructed at 40,50,60,70,80,90,100,and 110 keV,respectively.The groups were compared in terms of pulmonary artery CT value,image quality,and radiation dose.Results The pulmonary artery CT values were significantly higher in Group C40keV than in Groups B and C,but lower than in Group A.There was no significant difference in the image noise of Groups C40keV,B,and C.Moreover,Group A had the largest beam hardening artifacts of the superior vena cava(SVC),followed by Groups B and C.Group C40keV showed better vascular branching than the other three groups,among which Group B was superior to Group A.The subjective score of the image quality of Groups A,B,and C showed no significant difference,but the score was significantly higher in Group C40keV than in Groups A and B.The radiation dose was significantly lower in Group B than in Groups A and C.Conclusion Gd-CTPA is recommended to patients who are unsuitable for receiving an iodine-based CTPA.Furthermore,a turbo flash scan could surpass a dual-energy scan without consideration for virtual monoenergetic imaging.展开更多
We study the influence of limited-view scanning on the depth imaging of photoacoustic tomography. The situation, in which absorbers are located at different depths with respect to the limited-view scanning trajectory,...We study the influence of limited-view scanning on the depth imaging of photoacoustic tomography. The situation, in which absorbers are located at different depths with respect to the limited-view scanning trajectory, is called depth imaging and is investigated in this paper. The results show that limited-view scanning causes the reconstructed intensity of deep absorbers to be weaker than that of shallow ones and that deep absorbers will be invisible if the scanning range is too small. The concept of effective scanning angle is proposed to analyse that phenomenon. We find that an effective scanning angle can well predict the relationship between scanning angle and the intensity ratio of absorbers. In addition, limited-view scanning is employed to improve image quality.展开更多
The Bibliotheca Alexandrina (BA) has been developing and putting to use a workflow for tuming printed books into digital books as its contribution to the building of a Universal Digital Library. This workflow is a p...The Bibliotheca Alexandrina (BA) has been developing and putting to use a workflow for tuming printed books into digital books as its contribution to the building of a Universal Digital Library. This workflow is a process consisting of multiple phases, namely, scanning, image processing, OCR, digital archiving, document encoding, and publishing. Over the past couple of years, the BA has defined procedures and special techniques for the scanning, processing, OCR and publishing, especially of Arabic books. This workflow has been automated, allowing the governance of the different phases and making possible the production of 18000 books so far. The BA has also designed and implemented a framework for the encoding of digital books that allows publishing as well as a software system for managing the creation, maintenance, and publishing of the overall digital repository.展开更多
基金Project supported by the Science Foundation of Shanghai Munici pal Commission of Science and Technology ( Grant No.011461059)
文摘Acquisition of physical data with high precision is a key step in reverse engineering (RE). It is an important stimulative for the progress of reverse engineering with which various digitizing devices are invent ed, developed and made applicable. This paper introduces a three dimensional opt ical measurement method based on digital fringe projection technique in RE to im prove the technique through its application. A practical example is presented an d the result demonstrates the applicability and feasibility of the measurement s ystem as well as the reliability and validity of relevant methods and algorithms .
文摘For industrial computed tomography systems, generation II scan mode has a large field of view but time consuming and generation III has a small field of view but fast. In order to realize the rapid ICT test of large objects, a scan mode based on generation III called large field of view scan was discussed and its reconstruction algorithm based on FBP was deduced. The validity of the algorithm was verified by the results of computer simulation and experiments. Analysis showed that the effective scan field of view could be improved by more than 90% compared with that of generation III.
基金supported by grants from the Scientific Research Project of Hunan Health Commission in 2019(No.B2019071)the Scientific Research Project of Hunan Health Commission in 2020(No.B20200059).
文摘Objective To evaluate the feasibility of using gadopentetate dimeglumine(Gd-DTPA)for dual-energy computed tomography pulmonary angiography(CTPA).Methods Sixty-six patients were randomly divided into three groups and underwent CTPA.Group A had a turbo flash scan using an iohexol injection,Group B had a turbo flash scan using Gd-DTPA,and Group C had a dual-energy scan using Gd-DTPA.The original images of Group C were linearly blended with a blending factor of 0.5 or reconstructed at 40,50,60,70,80,90,100,and 110 keV,respectively.The groups were compared in terms of pulmonary artery CT value,image quality,and radiation dose.Results The pulmonary artery CT values were significantly higher in Group C40keV than in Groups B and C,but lower than in Group A.There was no significant difference in the image noise of Groups C40keV,B,and C.Moreover,Group A had the largest beam hardening artifacts of the superior vena cava(SVC),followed by Groups B and C.Group C40keV showed better vascular branching than the other three groups,among which Group B was superior to Group A.The subjective score of the image quality of Groups A,B,and C showed no significant difference,but the score was significantly higher in Group C40keV than in Groups A and B.The radiation dose was significantly lower in Group B than in Groups A and C.Conclusion Gd-CTPA is recommended to patients who are unsuitable for receiving an iodine-based CTPA.Furthermore,a turbo flash scan could surpass a dual-energy scan without consideration for virtual monoenergetic imaging.
基金Project supported by the National Basic Research Program of China(Grant No.2012CB921504)the National Natural Science Foundation of China(Grant Nos.10874088,10904069,and 11028408)the Natural Science Foundation of Jiangsu Province,China(Grant No.SBK201021985)
文摘We study the influence of limited-view scanning on the depth imaging of photoacoustic tomography. The situation, in which absorbers are located at different depths with respect to the limited-view scanning trajectory, is called depth imaging and is investigated in this paper. The results show that limited-view scanning causes the reconstructed intensity of deep absorbers to be weaker than that of shallow ones and that deep absorbers will be invisible if the scanning range is too small. The concept of effective scanning angle is proposed to analyse that phenomenon. We find that an effective scanning angle can well predict the relationship between scanning angle and the intensity ratio of absorbers. In addition, limited-view scanning is employed to improve image quality.
文摘The Bibliotheca Alexandrina (BA) has been developing and putting to use a workflow for tuming printed books into digital books as its contribution to the building of a Universal Digital Library. This workflow is a process consisting of multiple phases, namely, scanning, image processing, OCR, digital archiving, document encoding, and publishing. Over the past couple of years, the BA has defined procedures and special techniques for the scanning, processing, OCR and publishing, especially of Arabic books. This workflow has been automated, allowing the governance of the different phases and making possible the production of 18000 books so far. The BA has also designed and implemented a framework for the encoding of digital books that allows publishing as well as a software system for managing the creation, maintenance, and publishing of the overall digital repository.