BACKGROUND Left bundle branch pacing(LBBP)is a novel pacing modality of cardiac resynchronization therapy(CRT)that achieves more physiologic native ventricular activation than biventricular pacing(BiVP).AIM To explore...BACKGROUND Left bundle branch pacing(LBBP)is a novel pacing modality of cardiac resynchronization therapy(CRT)that achieves more physiologic native ventricular activation than biventricular pacing(BiVP).AIM To explore the validity of electromechanical resynchronization,clinical and echocardiographic response of LBBP-CRT.METHODS Systematic review and Meta-analysis were conducted in accordance with the standard guidelines as mentioned in detail in the methodology section.RESULTS In our analysis,the success rate of LBBP-CRT was determined to be 91.1%.LBBP CRT significantly shortened QRS duration,with significant improvement in echocardiographic parameters,including left ventricular ejection fraction,left ventricular end-diastolic diameter and left ventricular end-systolic diameter in comparison with BiVP-CRT.CONCLUSION A significant reduction in New York Heart Association class and B-type natriuretic peptide levels was also observed in the LBBP-CRT group vs BiVP-CRT group.Lastly,the LBBP-CRT cohort had a reduced pacing threshold at follow-up as compared to BiVP-CRT.展开更多
The recent systematic review and meta-analysis provided a comprehensive focus on the current state of cardiac resynchronization therapy(CRT).The authors determined the feasibility of physiological left bundle branch a...The recent systematic review and meta-analysis provided a comprehensive focus on the current state of cardiac resynchronization therapy(CRT).The authors determined the feasibility of physiological left bundle branch area pacing(LBBAP)in patients indicated for CRT through a careful analysis of trials.They found that LBBAP was associated with significant reductions in QRS duration,New York Heart Association functional class,B-type natriuretic peptide levels,and pacing thresholds as well as improvements in echocardiographic parameters compared to biventricular pacing.展开更多
AIM: To evaluate the safety and efficacy of the permanent high interventricular septal pacing in a long term follow up, as alternative to right ventricular apical pacing. METHODS: We retrospectively evaluated:(1) 244 ...AIM: To evaluate the safety and efficacy of the permanent high interventricular septal pacing in a long term follow up, as alternative to right ventricular apical pacing. METHODS: We retrospectively evaluated:(1) 244 patients(74 ± 8 years; 169 men, 75 women) implanted with a single(132 pts) or dual chamber(112 pts) pacemaker(PM) with ventricular screw-in lead placed at the right ventricular high septal parahisian site(SEPTAL pacing);(2) 22 patients with permanent pacemaker and low percentage of pacing(< 20%)(NO pacing);(3) 33 patients with high percentage(> 80%) right ventricular apical pacing(RVA). All patients had a narrow spontaneous QRS(101 ± 14 ms). We evaluated New York Heart Association(NYHA) class, quality of life(Qo L), 6 min walking test(6MWT) and left ventricular function(end-diastolic volume, LV-EDV; end-systolic volume, LVESV; ejection fraction, LV-EF) with 2D-echocardiography. RESULTS: Pacing parameters were stable duringfollow up(21 mo/patient). In SEPTAL pacing group we observed an improvement in NYHA class, Qo L score and 6MWT. While LV-EDV didn't significantly increase(104 ± 40 m L vs 100 ± 37 m L; P = 0.35), LV-ESV slightly increased(55 ± 31 m L vs 49 ± 27 m L; P = 0.05) and LV-EF slightly decreased(49% ± 11% vs 53% ± 11%; P = 0.001) but never falling < 45%. In the RVA pacing control group we observed a worsening of NYHA class and an important reduction of LV-EF(from 56% ± 6% to 43% ± 9%, P < 0.0001).CONCLUSION: Right ventricular permanent high septal pacing is safe and effective in a long term follow up evaluation; it could be a good alternative to the conventional RVA pacing in order to avoid its deleterious effects.展开更多
Purpose: Regadenoson (REG) is currently becoming the stress agent of choice in patients undergoing pharmacologic single photon emission computed tomography (SPECT). However, in patients with left bundle branch block (...Purpose: Regadenoson (REG) is currently becoming the stress agent of choice in patients undergoing pharmacologic single photon emission computed tomography (SPECT). However, in patients with left bundle branch block (LBBB) and ventricular paced rhythm (VPR), hesitation exists amongst clinicians to use REG-SPECT due to the concern that the increased heart rate could cause false positive SPECT results. We sought to evaluate the comparability of A-SPECT and REG-SPECT in patients with LBBB and VPR. Methods: Retrospective study of 30 patients who served as their own controls. All 30 patients who underwent REG-SPECT (Grp 1) were compared to their prior A-SPECT (Grp 2) done within two years prior to REG-SPECT. Heart rate (HR) and blood pressure (BP) parameters, ECG, stress perfusion and gated variables, SPECT ischemia, and side-effects were evaluated. Statistical significance was set at P < 0.05. Results: Grp 1 and Grp 2 were comparable in hemodynamic parameters with increase in HR and decrease in systolic and diastolic BP with administration of adenosine and REG stress agents. However, there were no significant differences found in hemodynamic parameters and II degree AV block between the groups. All normal A-SPECT were found to be normal with REG-SPECT. No differences could be found between the two groups among SPECT parameters. Muscle pain was significantly higher in REG (10.0% vs. 0.0%, P = 0.083) and so was the use of aminophylline (16.7% vs. 0.0%, P = 0.025) to relieve the side-effect. Conclusion: REG-SPECT can be administered in patients with LBBB and VPR patients based on favorable and comparable hemodynamic responses and arrhythmia occurrences to A-SPECT. REG-SPECT can also be used for adequate interpretation of presence or absence of SPECT ischemia particularly in the LAD territory without any concern for false positive perfusion defects.展开更多
Objective: Long-term right ventricular pacing has been associated with an increased risk of heart failure and cardiomyopathy. The pathophysiology of cardiomyopathy associated with right ventricular pacing remains uncl...Objective: Long-term right ventricular pacing has been associated with an increased risk of heart failure and cardiomyopathy. The pathophysiology of cardiomyopathy associated with right ventricular pacing remains unclear. We aim to evaluate the burden and short-term outcomes of ventricular dyssynchrony after immediate permanent pacemaker implantation. Materials and Methods: This prospective cohort study examined consecutive patients who had permanent pacemaker implantation at Vajira Hospital in 2019. Left ventricular systolic function, specifically left ventricular ejection fraction (LVEF) and echocardiographic ventricular dyssynchrony parameters were assessed. The endpoints included the prevalence of ventricular dyssynchrony, new-onset cardiomyopathy, heart failure, and death. The correlation between QRS complex duration, the burden of ventricular pacing, and echocardiographic ventricular dyssynchrony was measured. Results: Thirty-six consecutive patients underwent pacemaker implantation. The prevalence of mechanical ventricular dyssynchrony was 22.2% using the interventricular conduction delay method, 41.7% using LV pre-ejection period method, and 11.1% using the septal posterior wall motion abnormality method. Electrical ventricular dyssynchrony was 86.1% and new-onset cardiomyopathy was 17.1% after 3 months of permanent pacemaker implantation. The right ventricular pacing of more than 20% was significantly associated with cardiomyopathy (p < 0.022) and heart failure (log-rank, p = 0.049) within 3 months. But heart failure was not associated with mechanical ventricular dyssynchrony parameters (log-rank, p = 0.610;hazard ratio [HR], 1.53;95% confidence interval [CI], 0.29 - 7.96;p = 0.613 for IVMD and log-rank, p = 0.398;HR, 0.04;95% CI, 0.01 - 3316.7 for SPWMD). Conclusion: Mechanical and electrical ventricular dyssynchrony are common findings in right ventricular pacing. High-burden right ventricular pacing after 3 months of permanent pacemaker implantation is often associated with cardiomyopathy and heart failure, but mechanical and electrical ventricular dyssynchrony does not predict a short-term decline in left ventricular systolic function and heart failure.展开更多
The deleterious effects of long term right ventricular pacing are increasingly being recognized today.Current clinical practice favors the implantation of dual-chamber permanent pacemaker which maintains atrioventricu...The deleterious effects of long term right ventricular pacing are increasingly being recognized today.Current clinical practice favors the implantation of dual-chamber permanent pacemaker which maintains atrioventricular synchrony and is associated with better quality of life.However,despite the popular belief and common sense surrounding the superiority of dual-chamber pacing over single chamber pacing,the same has never been conclusively verified in clinical trials.Some observational evidence however,does exists which supports the improved cardiac hemodynamics,lower the rate of atrial fibrillation,heart failure and stroke in dual-chamber pacing compared to single-chamber pacing.In the index study by Haque et al,right ventricular pacing,particularly in ventricular paced,ven-tricular sensed,inhibited response and rate responsive pacemaker adversely im-pacted the left ventricular functions over 9-months compared to dual pacing,dual sensing,dual responsive and rate responsive pacemaker.Although there are key limitations of this study,these findings does support a growing body of evidence reinstating the superiority of dual chamber pacing compared to single chamber pacing.展开更多
目的探讨左束支区域起搏与右心室间隔起搏技术对老年患者左心室收缩同步性、心功能的影响。方法回顾性选取2022年2月至2023年3月期间于郴州市第一人民医院心血管内科接受永久性心脏起搏器植入术治疗的80例老年患者的临床资料,根据心脏...目的探讨左束支区域起搏与右心室间隔起搏技术对老年患者左心室收缩同步性、心功能的影响。方法回顾性选取2022年2月至2023年3月期间于郴州市第一人民医院心血管内科接受永久性心脏起搏器植入术治疗的80例老年患者的临床资料,根据心脏起搏电极植入部位分为两组,即对照组、观察组各40例。对照组患者于右心室间隔处植入心脏起搏器,观察组患者于左束支区域植入心脏起搏器。分别于患者心脏起搏器植入术后1个月、术后6个月、术后12个月观察各指标变化,包括左心室收缩同步性参数[左心室收缩期纵向应变达峰时间标准差(time to peak longitudinal strain standard deviation,Tls-SD)、最大差值(time to peak longitudinal strain maximum difference,Tls-dif),左心室收缩期径向应变达峰时间标准差(time to peak radial strain standard deviation,Trs-SD)、最大差值(time to peak radial strain maximum difference,Trs-dif),左心室收缩期环向应变达峰时间标准差(time to peak circumferential strain standard deviation,Tcs-SD)、最大差值(time to peak circumferential strain maximum difference,Tcs-dif)]以及心功能指标[左心室射血分数(left ventricular ejection fraction,LVEF)、心排血量(cardiac output,CO)、心脏指数(cardiac index,CI)]、心腔大小[右心房内径(right atrial inner diameter,RAD)、左心房内径(left atrial diameter,LAD)、左心室舒张末期内径(left ventricular end diastolic diameter,LVEDD)、左心室收缩末期内径(left ventricular end systolic diameter,LVESD)]、氨基末端脑钠肽前体(N-terminal pro-brain natriuretic peptide,NT-proBNP)浓度等。于术后12个月测定起搏参数(感知、阈值、阻抗、心室起搏比例),并统计心脏起搏器植入术后12个月内心力衰竭再入院、死亡等不良事件发生情况。结果术后各时间点观察组心功能指标LVEF、CO、CI略高于对照组,但两组比较差异无统计学意义(P>0.05)。术后各时间点观察组心腔大小指标RAD、LAD、LVEDD、LVESD低于对照组,尤其是术后12个月[RAD:(36.63±2.22)mm vs.(40.13±1.61)mm,LAD:(31.09±1.14)mm vs.(38.32±1.08)mm,LVEDD:(49.76±3.22)mm vs.(54.63±3.14)mm,LVESD:(40.64±2.11)mm vs.(48.11±3.24)mm,P<0.05]。术后各时间点观察组左心室收缩同步性指标LSDI、Tls-SD、Tls-dif、Trs-SD、Trs-dif、Tcs-SD、Tcs-dif均低于对照组,尤其是术后12个月[LSDI:4.86%±0.83%vs.9.49%±0.48%,Tls-SD:(14.42±1.78)ms vs.(25.00±1.43)ms,Tls-dif:(50.92±4.53)ms vs.(90.17±8.41)ms,Trs-SD:(50.37±4.33)ms vs.(69.44±6.52)ms,Trs-dif:(141.03±15.64)ms vs.(179.04±18.42)ms,Tcs-SD:(37.85±3.41)ms vs.(48.10±4.62)ms,Tcs-dif:(130.09±14.53)ms vs.(158.09±18.57)ms,P<0.05]。术后各时间点观察组NT-proBNP浓度略低于对照组,但两组比较差异无统计学意义(P>0.05)。两组起搏程控参数起搏感知、阻抗比较,差异无统计学意义(P<0.05);观察组起搏阈值低于对照组[(0.66±0.10)V vs.(0.75±0.12)V,P<0.05];两组起搏程控参数起搏感知、阻抗、阈值均处于正常范围。观察组心室起搏比例低于对照组(43.23%±4.53%vs.73.43%±6.56%,P<0.05)。术后12个月观察组心力衰竭再入院发生率明显低于对照组,差异有统计学意义(5.00%vs.22.50%,P<0.05)。结论左束支区域起搏技术在改善永久性心脏起搏器植入患者左心室收缩同步性、心功能方面优于右心室间隔起搏技术,术后12个月不良事件发生率较低,更有利于保护心功能,起搏参数稳定,属于一种有效且安全的起搏技术。展开更多
目的探讨左束支区域起搏(left bundle branch area pacing,LBBaP)对房室传导阻滞(AVB)患者术后新发心房颤动(new-onset atrial fibrillation,NOAF)和心房高频事件(atrial high rate episodes,AHREs)的影响。方法回顾性纳入84例行起搏治...目的探讨左束支区域起搏(left bundle branch area pacing,LBBaP)对房室传导阻滞(AVB)患者术后新发心房颤动(new-onset atrial fibrillation,NOAF)和心房高频事件(atrial high rate episodes,AHREs)的影响。方法回顾性纳入84例行起搏治疗的三度房室传导阻滞(ⅢAVB)患者,根据心室电极位置分为LBBaP组(n=42)和右室间隔部起搏(RVSP)组(n=42)。比较两组患者术前术后QRS波时限(QRSd)、心室起搏参数,并发症、脑卒中事件和NOAF、AHREs发生率。结果(1)LBBaP组术后NOAF、AHREs发生率均低于RVSP组(P<0.05)。(2)LBBaP组的p-QRSd短于RVSP组(P<0.05)。(3)两组患者心室起搏参数、并发症及脑卒中事件发生率之间差异无统计学意义(P>0.05)。结论相对于右室起搏,LBBaP术后AHREs、NOAF的发生率较低,可改善患者预后。展开更多
目的评估右心室起搏后,患起搏诱导性心肌病的老年病人升级至希浦系统起搏的临床疗效和安全性。方法在PubMed、Cochrane Library、Web of Science、Embase、中国知网、万方数据库、维普数据库检索希浦系统起搏对起搏诱导性心肌病疗效的...目的评估右心室起搏后,患起搏诱导性心肌病的老年病人升级至希浦系统起搏的临床疗效和安全性。方法在PubMed、Cochrane Library、Web of Science、Embase、中国知网、万方数据库、维普数据库检索希浦系统起搏对起搏诱导性心肌病疗效的相关文献,提取研究中有关临床获益和安全性的数据,在RevMan 5.4软件上进行Meta分析。结果共纳入8篇文献,包括185例病人,升级希浦系统起搏的成功率为95%。Meta分析结果显示:升级希浦系统起搏后,随访期间病人的左心室射血分数(MD=-11.73,95%CI:-14.74~-8.72,P<0.01)较升级术前提高,QRS波时限(MD=59.84,95%CI:55.98~63.70,P<0.01)较升级术前缩短,NYHA心功能分级(MD=1.05,95%CI:0.70~1.41,P<0.01)较升级术前明显降低,差异均有统计学意义。起搏阈值(MD=-0.11,95%CI:-0.24~0.02,P=0.08)和R波振幅(MD=-0.35,95%CI:-1.94~1.24,P=0.66)升级术前后差异无统计学意义。同时研究中观察到2例病人死亡。结论对于老年起搏诱导性心肌病病人,可考虑升级起搏方式为希浦系统起搏,不仅可以纠正长期右心室起搏引起的心脏电不同步和心室重塑,同时也能改善病人的临床心功能并减少手术相关并发症。展开更多
Background Hypertrophic obstructive cardiomyopathy (HOCM) carries an increased risk for sudden cardiac death. No data regarding the percutaneous transseptal myocardial ablation (PTSMA) and epicardial left ventricu...Background Hypertrophic obstructive cardiomyopathy (HOCM) carries an increased risk for sudden cardiac death. No data regarding the percutaneous transseptal myocardial ablation (PTSMA) and epicardial left ventricular pacing (LVP) were reported. Methods Seven patients with recurrent symptoms and increased resting left ventricular outflow tract pressure gradient (LVOTG) after PTSMA and another 14 patients with HOCM without history of PTSMA were studied. Both resting and dobutamine stress echocardiography, PTSMA and LVP were routinely performed. Results In patients without previous PTSMA procedure, mild reduction of resting LVOTG was detected at 5 minutes after left ventricular pacing, and this reduction became significant at 10 minutes. All patients were divided into successful and unsuccessful groups according to their response to LVP. In contrary to patients in unsuccessful group, resting and R-S2 stimuli-induced LVOTG during PTSMA procedure were decreased dramatically ((9±5) mmHg vs (58±12) mmHg, (12±2) mmHg vs (113±27) mmHg, P〈0.001). Analysis of Logistic regression demonstrated that only LVOTG level dudng left ventdcular pacing was an independent factor predicting the reduction of LVOTG immediately after PTSMA (odds ratio (OR), 0.59; 95% CI 2.67 to 5.82; P=0.0002). Conclusion Left ventricular endocardial temporary pacing plays a critical role in predicting acute effect on the reduction of LVOTG immediately after PTSMA procedure.展开更多
文摘BACKGROUND Left bundle branch pacing(LBBP)is a novel pacing modality of cardiac resynchronization therapy(CRT)that achieves more physiologic native ventricular activation than biventricular pacing(BiVP).AIM To explore the validity of electromechanical resynchronization,clinical and echocardiographic response of LBBP-CRT.METHODS Systematic review and Meta-analysis were conducted in accordance with the standard guidelines as mentioned in detail in the methodology section.RESULTS In our analysis,the success rate of LBBP-CRT was determined to be 91.1%.LBBP CRT significantly shortened QRS duration,with significant improvement in echocardiographic parameters,including left ventricular ejection fraction,left ventricular end-diastolic diameter and left ventricular end-systolic diameter in comparison with BiVP-CRT.CONCLUSION A significant reduction in New York Heart Association class and B-type natriuretic peptide levels was also observed in the LBBP-CRT group vs BiVP-CRT group.Lastly,the LBBP-CRT cohort had a reduced pacing threshold at follow-up as compared to BiVP-CRT.
文摘The recent systematic review and meta-analysis provided a comprehensive focus on the current state of cardiac resynchronization therapy(CRT).The authors determined the feasibility of physiological left bundle branch area pacing(LBBAP)in patients indicated for CRT through a careful analysis of trials.They found that LBBAP was associated with significant reductions in QRS duration,New York Heart Association functional class,B-type natriuretic peptide levels,and pacing thresholds as well as improvements in echocardiographic parameters compared to biventricular pacing.
文摘AIM: To evaluate the safety and efficacy of the permanent high interventricular septal pacing in a long term follow up, as alternative to right ventricular apical pacing. METHODS: We retrospectively evaluated:(1) 244 patients(74 ± 8 years; 169 men, 75 women) implanted with a single(132 pts) or dual chamber(112 pts) pacemaker(PM) with ventricular screw-in lead placed at the right ventricular high septal parahisian site(SEPTAL pacing);(2) 22 patients with permanent pacemaker and low percentage of pacing(< 20%)(NO pacing);(3) 33 patients with high percentage(> 80%) right ventricular apical pacing(RVA). All patients had a narrow spontaneous QRS(101 ± 14 ms). We evaluated New York Heart Association(NYHA) class, quality of life(Qo L), 6 min walking test(6MWT) and left ventricular function(end-diastolic volume, LV-EDV; end-systolic volume, LVESV; ejection fraction, LV-EF) with 2D-echocardiography. RESULTS: Pacing parameters were stable duringfollow up(21 mo/patient). In SEPTAL pacing group we observed an improvement in NYHA class, Qo L score and 6MWT. While LV-EDV didn't significantly increase(104 ± 40 m L vs 100 ± 37 m L; P = 0.35), LV-ESV slightly increased(55 ± 31 m L vs 49 ± 27 m L; P = 0.05) and LV-EF slightly decreased(49% ± 11% vs 53% ± 11%; P = 0.001) but never falling < 45%. In the RVA pacing control group we observed a worsening of NYHA class and an important reduction of LV-EF(from 56% ± 6% to 43% ± 9%, P < 0.0001).CONCLUSION: Right ventricular permanent high septal pacing is safe and effective in a long term follow up evaluation; it could be a good alternative to the conventional RVA pacing in order to avoid its deleterious effects.
文摘Purpose: Regadenoson (REG) is currently becoming the stress agent of choice in patients undergoing pharmacologic single photon emission computed tomography (SPECT). However, in patients with left bundle branch block (LBBB) and ventricular paced rhythm (VPR), hesitation exists amongst clinicians to use REG-SPECT due to the concern that the increased heart rate could cause false positive SPECT results. We sought to evaluate the comparability of A-SPECT and REG-SPECT in patients with LBBB and VPR. Methods: Retrospective study of 30 patients who served as their own controls. All 30 patients who underwent REG-SPECT (Grp 1) were compared to their prior A-SPECT (Grp 2) done within two years prior to REG-SPECT. Heart rate (HR) and blood pressure (BP) parameters, ECG, stress perfusion and gated variables, SPECT ischemia, and side-effects were evaluated. Statistical significance was set at P < 0.05. Results: Grp 1 and Grp 2 were comparable in hemodynamic parameters with increase in HR and decrease in systolic and diastolic BP with administration of adenosine and REG stress agents. However, there were no significant differences found in hemodynamic parameters and II degree AV block between the groups. All normal A-SPECT were found to be normal with REG-SPECT. No differences could be found between the two groups among SPECT parameters. Muscle pain was significantly higher in REG (10.0% vs. 0.0%, P = 0.083) and so was the use of aminophylline (16.7% vs. 0.0%, P = 0.025) to relieve the side-effect. Conclusion: REG-SPECT can be administered in patients with LBBB and VPR patients based on favorable and comparable hemodynamic responses and arrhythmia occurrences to A-SPECT. REG-SPECT can also be used for adequate interpretation of presence or absence of SPECT ischemia particularly in the LAD territory without any concern for false positive perfusion defects.
文摘Objective: Long-term right ventricular pacing has been associated with an increased risk of heart failure and cardiomyopathy. The pathophysiology of cardiomyopathy associated with right ventricular pacing remains unclear. We aim to evaluate the burden and short-term outcomes of ventricular dyssynchrony after immediate permanent pacemaker implantation. Materials and Methods: This prospective cohort study examined consecutive patients who had permanent pacemaker implantation at Vajira Hospital in 2019. Left ventricular systolic function, specifically left ventricular ejection fraction (LVEF) and echocardiographic ventricular dyssynchrony parameters were assessed. The endpoints included the prevalence of ventricular dyssynchrony, new-onset cardiomyopathy, heart failure, and death. The correlation between QRS complex duration, the burden of ventricular pacing, and echocardiographic ventricular dyssynchrony was measured. Results: Thirty-six consecutive patients underwent pacemaker implantation. The prevalence of mechanical ventricular dyssynchrony was 22.2% using the interventricular conduction delay method, 41.7% using LV pre-ejection period method, and 11.1% using the septal posterior wall motion abnormality method. Electrical ventricular dyssynchrony was 86.1% and new-onset cardiomyopathy was 17.1% after 3 months of permanent pacemaker implantation. The right ventricular pacing of more than 20% was significantly associated with cardiomyopathy (p < 0.022) and heart failure (log-rank, p = 0.049) within 3 months. But heart failure was not associated with mechanical ventricular dyssynchrony parameters (log-rank, p = 0.610;hazard ratio [HR], 1.53;95% confidence interval [CI], 0.29 - 7.96;p = 0.613 for IVMD and log-rank, p = 0.398;HR, 0.04;95% CI, 0.01 - 3316.7 for SPWMD). Conclusion: Mechanical and electrical ventricular dyssynchrony are common findings in right ventricular pacing. High-burden right ventricular pacing after 3 months of permanent pacemaker implantation is often associated with cardiomyopathy and heart failure, but mechanical and electrical ventricular dyssynchrony does not predict a short-term decline in left ventricular systolic function and heart failure.
文摘The deleterious effects of long term right ventricular pacing are increasingly being recognized today.Current clinical practice favors the implantation of dual-chamber permanent pacemaker which maintains atrioventricular synchrony and is associated with better quality of life.However,despite the popular belief and common sense surrounding the superiority of dual-chamber pacing over single chamber pacing,the same has never been conclusively verified in clinical trials.Some observational evidence however,does exists which supports the improved cardiac hemodynamics,lower the rate of atrial fibrillation,heart failure and stroke in dual-chamber pacing compared to single-chamber pacing.In the index study by Haque et al,right ventricular pacing,particularly in ventricular paced,ven-tricular sensed,inhibited response and rate responsive pacemaker adversely im-pacted the left ventricular functions over 9-months compared to dual pacing,dual sensing,dual responsive and rate responsive pacemaker.Although there are key limitations of this study,these findings does support a growing body of evidence reinstating the superiority of dual chamber pacing compared to single chamber pacing.
文摘目的探讨左束支区域起搏与右心室间隔起搏技术对老年患者左心室收缩同步性、心功能的影响。方法回顾性选取2022年2月至2023年3月期间于郴州市第一人民医院心血管内科接受永久性心脏起搏器植入术治疗的80例老年患者的临床资料,根据心脏起搏电极植入部位分为两组,即对照组、观察组各40例。对照组患者于右心室间隔处植入心脏起搏器,观察组患者于左束支区域植入心脏起搏器。分别于患者心脏起搏器植入术后1个月、术后6个月、术后12个月观察各指标变化,包括左心室收缩同步性参数[左心室收缩期纵向应变达峰时间标准差(time to peak longitudinal strain standard deviation,Tls-SD)、最大差值(time to peak longitudinal strain maximum difference,Tls-dif),左心室收缩期径向应变达峰时间标准差(time to peak radial strain standard deviation,Trs-SD)、最大差值(time to peak radial strain maximum difference,Trs-dif),左心室收缩期环向应变达峰时间标准差(time to peak circumferential strain standard deviation,Tcs-SD)、最大差值(time to peak circumferential strain maximum difference,Tcs-dif)]以及心功能指标[左心室射血分数(left ventricular ejection fraction,LVEF)、心排血量(cardiac output,CO)、心脏指数(cardiac index,CI)]、心腔大小[右心房内径(right atrial inner diameter,RAD)、左心房内径(left atrial diameter,LAD)、左心室舒张末期内径(left ventricular end diastolic diameter,LVEDD)、左心室收缩末期内径(left ventricular end systolic diameter,LVESD)]、氨基末端脑钠肽前体(N-terminal pro-brain natriuretic peptide,NT-proBNP)浓度等。于术后12个月测定起搏参数(感知、阈值、阻抗、心室起搏比例),并统计心脏起搏器植入术后12个月内心力衰竭再入院、死亡等不良事件发生情况。结果术后各时间点观察组心功能指标LVEF、CO、CI略高于对照组,但两组比较差异无统计学意义(P>0.05)。术后各时间点观察组心腔大小指标RAD、LAD、LVEDD、LVESD低于对照组,尤其是术后12个月[RAD:(36.63±2.22)mm vs.(40.13±1.61)mm,LAD:(31.09±1.14)mm vs.(38.32±1.08)mm,LVEDD:(49.76±3.22)mm vs.(54.63±3.14)mm,LVESD:(40.64±2.11)mm vs.(48.11±3.24)mm,P<0.05]。术后各时间点观察组左心室收缩同步性指标LSDI、Tls-SD、Tls-dif、Trs-SD、Trs-dif、Tcs-SD、Tcs-dif均低于对照组,尤其是术后12个月[LSDI:4.86%±0.83%vs.9.49%±0.48%,Tls-SD:(14.42±1.78)ms vs.(25.00±1.43)ms,Tls-dif:(50.92±4.53)ms vs.(90.17±8.41)ms,Trs-SD:(50.37±4.33)ms vs.(69.44±6.52)ms,Trs-dif:(141.03±15.64)ms vs.(179.04±18.42)ms,Tcs-SD:(37.85±3.41)ms vs.(48.10±4.62)ms,Tcs-dif:(130.09±14.53)ms vs.(158.09±18.57)ms,P<0.05]。术后各时间点观察组NT-proBNP浓度略低于对照组,但两组比较差异无统计学意义(P>0.05)。两组起搏程控参数起搏感知、阻抗比较,差异无统计学意义(P<0.05);观察组起搏阈值低于对照组[(0.66±0.10)V vs.(0.75±0.12)V,P<0.05];两组起搏程控参数起搏感知、阻抗、阈值均处于正常范围。观察组心室起搏比例低于对照组(43.23%±4.53%vs.73.43%±6.56%,P<0.05)。术后12个月观察组心力衰竭再入院发生率明显低于对照组,差异有统计学意义(5.00%vs.22.50%,P<0.05)。结论左束支区域起搏技术在改善永久性心脏起搏器植入患者左心室收缩同步性、心功能方面优于右心室间隔起搏技术,术后12个月不良事件发生率较低,更有利于保护心功能,起搏参数稳定,属于一种有效且安全的起搏技术。
文摘目的探讨左束支区域起搏(left bundle branch area pacing,LBBaP)对房室传导阻滞(AVB)患者术后新发心房颤动(new-onset atrial fibrillation,NOAF)和心房高频事件(atrial high rate episodes,AHREs)的影响。方法回顾性纳入84例行起搏治疗的三度房室传导阻滞(ⅢAVB)患者,根据心室电极位置分为LBBaP组(n=42)和右室间隔部起搏(RVSP)组(n=42)。比较两组患者术前术后QRS波时限(QRSd)、心室起搏参数,并发症、脑卒中事件和NOAF、AHREs发生率。结果(1)LBBaP组术后NOAF、AHREs发生率均低于RVSP组(P<0.05)。(2)LBBaP组的p-QRSd短于RVSP组(P<0.05)。(3)两组患者心室起搏参数、并发症及脑卒中事件发生率之间差异无统计学意义(P>0.05)。结论相对于右室起搏,LBBaP术后AHREs、NOAF的发生率较低,可改善患者预后。
文摘目的评估右心室起搏后,患起搏诱导性心肌病的老年病人升级至希浦系统起搏的临床疗效和安全性。方法在PubMed、Cochrane Library、Web of Science、Embase、中国知网、万方数据库、维普数据库检索希浦系统起搏对起搏诱导性心肌病疗效的相关文献,提取研究中有关临床获益和安全性的数据,在RevMan 5.4软件上进行Meta分析。结果共纳入8篇文献,包括185例病人,升级希浦系统起搏的成功率为95%。Meta分析结果显示:升级希浦系统起搏后,随访期间病人的左心室射血分数(MD=-11.73,95%CI:-14.74~-8.72,P<0.01)较升级术前提高,QRS波时限(MD=59.84,95%CI:55.98~63.70,P<0.01)较升级术前缩短,NYHA心功能分级(MD=1.05,95%CI:0.70~1.41,P<0.01)较升级术前明显降低,差异均有统计学意义。起搏阈值(MD=-0.11,95%CI:-0.24~0.02,P=0.08)和R波振幅(MD=-0.35,95%CI:-1.94~1.24,P=0.66)升级术前后差异无统计学意义。同时研究中观察到2例病人死亡。结论对于老年起搏诱导性心肌病病人,可考虑升级起搏方式为希浦系统起搏,不仅可以纠正长期右心室起搏引起的心脏电不同步和心室重塑,同时也能改善病人的临床心功能并减少手术相关并发症。
文摘Background Hypertrophic obstructive cardiomyopathy (HOCM) carries an increased risk for sudden cardiac death. No data regarding the percutaneous transseptal myocardial ablation (PTSMA) and epicardial left ventricular pacing (LVP) were reported. Methods Seven patients with recurrent symptoms and increased resting left ventricular outflow tract pressure gradient (LVOTG) after PTSMA and another 14 patients with HOCM without history of PTSMA were studied. Both resting and dobutamine stress echocardiography, PTSMA and LVP were routinely performed. Results In patients without previous PTSMA procedure, mild reduction of resting LVOTG was detected at 5 minutes after left ventricular pacing, and this reduction became significant at 10 minutes. All patients were divided into successful and unsuccessful groups according to their response to LVP. In contrary to patients in unsuccessful group, resting and R-S2 stimuli-induced LVOTG during PTSMA procedure were decreased dramatically ((9±5) mmHg vs (58±12) mmHg, (12±2) mmHg vs (113±27) mmHg, P〈0.001). Analysis of Logistic regression demonstrated that only LVOTG level dudng left ventdcular pacing was an independent factor predicting the reduction of LVOTG immediately after PTSMA (odds ratio (OR), 0.59; 95% CI 2.67 to 5.82; P=0.0002). Conclusion Left ventricular endocardial temporary pacing plays a critical role in predicting acute effect on the reduction of LVOTG immediately after PTSMA procedure.