期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
TIGHT BINDING STUDIES ON THE STRUCTURAL PROPERTIES OF SILICON CLUSTERS
1
作者 W.Fa and C.L.Luo Departmentof Physics, Nanjing Normal University , Nanjing 210097 ,China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1999年第4期534-538,共5页
Tight binding molecular dynamicsand simulated annealingtechniquesareemployed tostudythestructuralpropertiesofsilicon clusterscontaining 2 14 atoms.Itisfoundthatour results for Si2 Si6 agree well with thoseobtained... Tight binding molecular dynamicsand simulated annealingtechniquesareemployed tostudythestructuralpropertiesofsilicon clusterscontaining 2 14 atoms.Itisfoundthatour results for Si2 Si6 agree well with thoseobtained using abinitiotechniques. Further Si cluster re search which givethesignificantprediction hasbeen made. 展开更多
关键词 tight binding molecular dynamics( TBMD) Sin cluster
下载PDF
Protein adsorption in two-dimensional electrochromatography packed with superporous and microporous cellulose beads
2
作者 Dongmei WANG Guodong JIA +2 位作者 Liang XU Xiaoyan DONG Yan SUN 《Frontiers of Chemical Science and Engineering》 SCIE EI CSCD 2009年第3期229-234,共6页
Anion-exchange superporous cellulose(DEAE-SC)and microporous cellulose(DEAE-MC)adsorbents were packed in an electrochromatographic column,and the effect of external electric field(eEF)on the dynamic adsorption was inv... Anion-exchange superporous cellulose(DEAE-SC)and microporous cellulose(DEAE-MC)adsorbents were packed in an electrochromatographic column,and the effect of external electric field(eEF)on the dynamic adsorption was investigated.The column was designed to provide longitudinal,transverse or 2-dimensional(2D)eEF.It was found that the electro-kinetic effect caused by the introduction of an electric field played an important role in the dynamic adsorption of bovine serum albumin to the adsorbents.The dynamic binding capacity(DBC)in the presence of 2D eEF was higher than in the presence of a one-dimensional eEF.The effect of flow velocity on the DBC of the two adsorbents was also demonstrated.It was found that the effect of electric field on the DEAE-MC column was more remarkable than that on the DEAE-SC column at the same flow rate,whereas the DEAE-SC column showed higher DBC and adsorption efficiency(AE)than the DEAE-MC column.With increasing flow rate,the DEAE-SC column could still offer high DBC and AE in the presence of the 2D eEF.For example,a DBC of 21.4mg/mL and an AE of 57.7%were obtained even at a flow rate as high as 900cm/h.The results indicate that the 2D electrochromatography packed with the superporous cellulose adsorbent is promising for high-speed protein chromatography. 展开更多
关键词 ELECTROCHROMATOGRAPHY two-dimensional electric field dynamic binding capacity superporous cellulose bead PROTEIN
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部