The rolling bearing friction torque which is characterized by its uncertainty and nonlinearity affects heavily the dynamic performance of a system such as missiles, spacecrafts and radars, etc. It is difficult to use ...The rolling bearing friction torque which is characterized by its uncertainty and nonlinearity affects heavily the dynamic performance of a system such as missiles, spacecrafts and radars, etc. It is difficult to use the classical statistical theory to evaluate the dynamic evaluation of the rolling bearing friction torque for the lack of prior information about both probability distribution and trends. For this reason, based on the information poor system theory and combined with the correlation dimension in chaos theory, the concepts about the mean of the dynamic fluctuant range (MDFR) and the grey relation are proposed to resolve the problem about evaluating the nonlinear characteristic and the dynamic uncertainty of the rolling bearing friction torque. Friction torque experiments are done for three types of the rolling bearings marked with HKTA, HKTB and HKTC separately; meantime, the correlation dimension and MDFR are calculated to describe the nonlinear characteristic and the dynamic uncertainty of the friction torque, respectively. And the experiments reveal that there is a certain grey relation between the nonlinear characteristic and the dynamic uncertainty of the rolling bearing friction torque, viz. MDFR will become the nonlinear increasing trend with the correlation dimension increasing. Under the condition of fewer characteristic data and the lack of prior information about both probability distribution and trends, the unitive evaluation for the nonlinear characteristic and the dynamic uncertainty of the rolling bearing friction torque is realized with the grey confidence level of 87.7%-96.3%.展开更多
In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-ene...In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-energy imaging calorimeter(HEIC) is currently being developed as a homogeneous calorimeter that utilizes long bismuth germanate(BGO) scintillation crystals as both absorbers and detectors. To accurately measure the energy deposition in the BGO bar of HEIC, a highdynamic-range readout method using a silicon photomultiplier(SiPM) and multiphotodiode(PD) with different active areas has been proposed. A prototype readout system that adopts multichannel charge measurement ASICs was also developed to read out the combined system of SiPMs and PDs. Preliminary tests confirmed the feasibility of the readout scheme, which is expected to have a dynamic range close to 10~6.展开更多
The capability of neurons to discriminate between intensity of external stimulus is measured by its dynamic range.A larger dynamic range indicates a greater probability of neuronal survival.In this study,the potential...The capability of neurons to discriminate between intensity of external stimulus is measured by its dynamic range.A larger dynamic range indicates a greater probability of neuronal survival.In this study,the potential roles of adaptation mechanisms(ion currents) in modulating neuronal dynamic range were numerically investigated.Based on the adaptive exponential integrate-and-fire model,which includes two different adaptation mechanisms,i.e.subthreshold and suprathreshold(spike-triggered) adaptation,our results reveal that the two adaptation mechanisms exhibit rather different roles in regulating neuronal dynamic range.Specifically,subthreshold adaptation acts as a negative factor that observably decreases the neuronal dynamic range,while suprathreshold adaptation has little influence on the neuronal dynamic range.Moreover,when stochastic noise was introduced into the adaptation mechanisms,the dynamic range was apparently enhanced,regardless of what state the neuron was in,e.g.adaptive or non-adaptive.Our model results suggested that the neuronal dynamic range can be differentially modulated by different adaptation mechanisms.Additionally,noise was a non-ignorable factor,which could effectively modulate the neuronal dynamic range.展开更多
A 2.4GHz 0.18μm CMOS gain-switched single-end Low Noise Amplifier (LNA) and a passive mixer with no external balun for near-zero-IF (Intermediate Frequency)/RF (Radio Frequency) applications are described. The ...A 2.4GHz 0.18μm CMOS gain-switched single-end Low Noise Amplifier (LNA) and a passive mixer with no external balun for near-zero-IF (Intermediate Frequency)/RF (Radio Frequency) applications are described. The LNA, fabricated in the 0.18μm 1P6M CMOS technology, adopts a gain-switched technique to increase the linearity and enlarge the dynamic range. The mixer is an IQ-based passive topology. Measurements of the CMOS chip are performed on the FR-4 PCB and the input is matched to 50Ω. Combining LNA and mixer, the front-end measured performances in high gain state are: -15dB of Sll, 18.5dB of voltage gain, 4.6dB of noise figure, 15dBm of IIP3, 85dBm to -10dBm dynamic range. The full circuit drains 6mA from a 1.8V supply.展开更多
Zero-field single-beam atomic magnetometers with transverse parametric modulation for ultra-weak magnetic field detection have attracted widespread attention recently.In this study,we present a comprehensive response ...Zero-field single-beam atomic magnetometers with transverse parametric modulation for ultra-weak magnetic field detection have attracted widespread attention recently.In this study,we present a comprehensive response model and propose a modification method of conventional first harmonic response by introducing the second harmonic correction.The proposed modification method gives improvement in dynamic range and reduction of linearity error.Additionally,our modification method shows suppression of response instability caused by optical intensity and frequency fluctuations.An atomic magnetometer with single-beam configuration is built to compare the performance between our proposed method and the conventional method.The results indicate that our method’s magnetic field response signal achieves a 5-fold expansion of dynamic range from 2 nT to 10 nT,with the linearity error decreased from 5%to 1%.Under the fluctuations of 5%for optical intensity and±15 GHz detuning of frequency,the proposed modification method maintains intensityrelated instability less than 1%and frequency-related instability less than 8%while the conventional method suffers 15%and 38%,respectively.Our method is promising for future high-sensitive and long-term stable optically pumped atomic sensors.展开更多
We report the design of a sensitive,electrochemical aptasensor for detection of ochratoxin A(OTA)with an extraordinary tunable dynamic sensing range.This electrochemical aptasensor is constructed based on the target i...We report the design of a sensitive,electrochemical aptasensor for detection of ochratoxin A(OTA)with an extraordinary tunable dynamic sensing range.This electrochemical aptasensor is constructed based on the target induced aptamer-folding detection mechanism and the recognition between OTA and its aptamers results in the conformational change of the aptamer probe and thus signal changes for measurement.The dynamic sensing range of the electrochemical aptasensor is successfully tuned by introduction of free assistant aptamer probes in the sensing system.Our electrochemical aptasensor shows an extraordinary dynamic sensing range of 11-order magnitude of OTA concentration from 10^−8 to 10^2 ng/g.Of great significance,the signal response in all OTA concentration ranges is at the same current scale,demonstrating that our sensing protocol in this research could be applied for accurate detections of OTA in a broad range without using any complicated treatment of signal amplification.Finally,OTA spiked red wine and maize samples in different dynamic sensing ranges are determined with the electrochemical aptasensor under optimized sensing conditions.This tuning strategy of dynamic sensing range may offer a promising platform for electrochemical aptasensor optimizations in practical applications.展开更多
Effects of refractory period on the dynamical range in excitable networks are studied by computer simulations and theoretical analysis. The first effect is that the maximum or peak of the dynamical range appears when ...Effects of refractory period on the dynamical range in excitable networks are studied by computer simulations and theoretical analysis. The first effect is that the maximum or peak of the dynamical range appears when the largest eigenvalue of adjacent matrix is larger than one. We present a modification of the theory of the critical point by considering the correlation between excited nodes and their neighbors, which is brought by the refractory period. Our analysis provides the interpretation for the shift of the peak of the dynamical range. The effect is negligible when the average degree of the network is large. The second effect is that the dynamical range increases as the length of refractory period increases, and it is independent of the average degree. We present the mechanism of the second effect. As the refractory period increases,the saturated response decreases. This makes the bottom boundary of the dynamical range smaller and the dynamical range extend.展开更多
Distortion-free data embedding is a technique which can assure that not only the secret data is correctly extracted but also the cover media is recovered without any distortion after secret data is extracted completel...Distortion-free data embedding is a technique which can assure that not only the secret data is correctly extracted but also the cover media is recovered without any distortion after secret data is extracted completely. Because of these advantages, this technique attracts the attention of many researchers. In this paper, a new distortion-free data embedding scheme for high dynamic range (HDR) images is proposed. By depending on Cartesian product, this scheme can obtain higher embedding capacity while maintaining the exactly identical cover image and stego image when using the tone mapping algorithms. In experimental results, the proposed scheme is superior to Yu et aL's scheme in regard to the embedding rate——an average embedding rate of 0.1355 bpp compared with Yn et aL's scheme (0.1270 bpp).展开更多
Objective: To study the effects of clinical concentration of sevoflurane on activity of wide dynamic range neurons. Methods: Eight Spraque-Dawley rats(male) were selected. Their spinal cords were exposed and transecte...Objective: To study the effects of clinical concentration of sevoflurane on activity of wide dynamic range neurons. Methods: Eight Spraque-Dawley rats(male) were selected. Their spinal cords were exposed and transected at T 9-10 level. The rate of firings of single neurons in the dorsal horn in response to electrical stimulation of skin was recorded with microelectrodes. The early and late discharges were observed when rats inhaled 0.5%, 1.0%, 1.5%, and 2.0% sevoflurane. Results: Sevoflurane suppressed the early and late discharges at the concentration of 0.5%, 1.0%, 1.5%, and 2.0%. Compared with early discharges, the extent of inhibition of late discharges was wider at the concentration of 1%, 1.5%, and 2.0% of sevoflurane. Conclusion: It is indicated that sevoflurane could suppress the transmission of nociceptive and non-nociceptive stimulation at dorsal horn. The suppression on nociceptive imput is stronger than that on non-nociceptive imput when the concentration of sevoflurane is more than 1%.展开更多
For the optimization of dynamic range and bandwidth of digital intermediate frequency receiver(DIFR), main factors affecting them and their relationships are studied. Firstly, the DIFR sensitivity, bandwidth, noise fa...For the optimization of dynamic range and bandwidth of digital intermediate frequency receiver(DIFR), main factors affecting them and their relationships are studied. Firstly, the DIFR sensitivity, bandwidth, noise factor of radio frequency (RF) analog front-end (RFAF), and processing gain of intermediate frequency(IF) sampling are analyzed. Secondly, the constraint relationship of the noise factor of RFAF, the signal-to-noise ratio of ADC and the dynamic range of DIFR are studied. The relationship between the dynamic range and the RFAF gain, and that of the extended dynamic range and the RF AGC(automatic gain control) step are educed and simulated. These results can be used as theory foundations and design references for the implementation and optimization of the large dynamic range and wideband DIFR.展开更多
Radio Frequency (RF) switch circuit is the basic part of microwave devices and systems. The non-linearity distortion figure is necessary in the field of large dynamic range of signal. This letter analyzes the basic sw...Radio Frequency (RF) switch circuit is the basic part of microwave devices and systems. The non-linearity distortion figure is necessary in the field of large dynamic range of signal. This letter analyzes the basic switch circuit and its inter-modulation, and studies in detail the measurement methods and systems of RF switch intercept point. It has provided cascaded simulation testing methods, which can accurately measure the PF switch, of which the second or third order intercept point value is above 75dB and 60dB, respectively. As the testing results are consistent with the theoretical analyses, it proves that the validity of the method satisfies the requirements of large scaled linearity measurement in engineering.展开更多
Due to the existing limited dynamic range a camera cannot reveal all the details in a high-dynamic range scene. In order to solve this problem,this paper presents a multi-exposure fusion method for getting high qualit...Due to the existing limited dynamic range a camera cannot reveal all the details in a high-dynamic range scene. In order to solve this problem,this paper presents a multi-exposure fusion method for getting high quality images in high dynamic range scene. First,a set of multi-exposure images is obtained by multiple exposures in a same scene and their brightness condition is analyzed. Then,multi-exposure images under the same scene are decomposed using dual-tree complex wavelet transform( DT-CWT),and their low and high frequency components are obtained. Weight maps according to the brightness condition are assigned to the low components for fusion. Maximizing the region Sum Modified-Laplacian( SML) is adopted for high-frequency components fusing. Finally,the fused image is acquired by subjecting the low and high frequency coefficients to inverse DT-CWT.Experimental results show that the proposed approach generates high quality results with uniform distributed brightness and rich details. The proposed method is efficient and robust in varies scenes.展开更多
The logarithmic response complementary metal oxide semiconductor (CMOS) image sensor provides a wide dynamic range, but its drawback is the lack of simple fixed pattern noise(FPN) cancellation scheme. Designed is ...The logarithmic response complementary metal oxide semiconductor (CMOS) image sensor provides a wide dynamic range, but its drawback is the lack of simple fixed pattern noise(FPN) cancellation scheme. Designed is a novel logarithmic active pixel sensor(APS) with high dynamic range and high output swing. Firstly, the operation principle of mixed-model APS is introduced. The pixel can work in three operation modes by choosing the proper control signals. Then, FPN sources of logarithmic APS are analyzed, and double-sampled technique is implemented to reduce FPN. Finally, according to the simulation results, layout is designed and has passed design rule check(DRC), electronic rule eheck(ERC) and layout versus schematic(LVS) verifications, and the post-simulation results are basically in agreement with the simulation results. Dynamic range of the new logarithmic APS can reach about 140 dB; and the output swing is about 750 inV. Results show that by using double sampled technique, most FPN is eliminated and the dynamic range is enhanced.展开更多
An effective method for object shape recovery using HDRIs (high dynamic range images) is proposed. The radiance values of each point on the reference sphere and target object are firstly calculated, thus the set of ...An effective method for object shape recovery using HDRIs (high dynamic range images) is proposed. The radiance values of each point on the reference sphere and target object are firstly calculated, thus the set of candidate normals of each target point are found by comparing its radiance to that of each reference sphere point. In single-image shape recovery, a smoothness operation is applied to the target normals to obtain a stable and reasonable result; while in photometric stereo, radiance vectors of reference and target objects formed due to illuminations under different fight source directions are directly compared to get the most suitable target normals. Finally, the height values can be recovered from the resulting normal field. Because diffuse and specular reflection are handled in an unified framework with radiance, our approach eliminates the limitation presented in most recovery strategies, i.e., only Lambertian model can be used. The experiment results from the real and synthesized images show the performance of our approach.展开更多
In Electronic Warfare (EW) receivers, the desired Dynamic Range (DR) often far exceeds the dynamic range attainable with available Analog-to-Digital Converter (ADC) technology. ADC is the key bottleneck in achie...In Electronic Warfare (EW) receivers, the desired Dynamic Range (DR) often far exceeds the dynamic range attainable with available Analog-to-Digital Converter (ADC) technology. ADC is the key bottleneck in achieving the needed dynamic range. In this paper, an approach for improving the effective DR by utiliTing multiple amplifiers is presented. The amplifiers, arranged in parallel channels with different gains, can increase the dynamic range greatly.展开更多
A novel charge exchanging compensation (CEC) technique is proposed for a wideband sample-and-hold (S/H) circuit applied in an IF sampling ADC. The CEC technique compensates the sampling bandwidth by eliminating th...A novel charge exchanging compensation (CEC) technique is proposed for a wideband sample-and-hold (S/H) circuit applied in an IF sampling ADC. The CEC technique compensates the sampling bandwidth by eliminating the impact from finite on-resistance of the sampling switch, and avoids increasing clock feedthrough and charge injection. Meanwhile, a low power two stage OTA with a class AB output stage is designed to provide the S/H a 3Vp-p input range under 1.8V power. The S/H achieves a 94dB spurious-free dynamic range for a 200MHz input signal at a 100Ms/s sample rate and consumes only 26mW with a 5.5pF load.展开更多
China plans to develop the next generation dark matter particle explorer satellite,referred to as the Very Large Area Space Telescope(VLAST).As an essential step in this process,the prototype design of detectors and e...China plans to develop the next generation dark matter particle explorer satellite,referred to as the Very Large Area Space Telescope(VLAST).As an essential step in this process,the prototype design of detectors and electronics for the VLAST is currently underway.The nuclide detector is a core detector in the VLAST.It mainly measures nuclides’charges and distinguishes high-energy gamma rays and electrons.This paper will discuss the prototype readout electronics for the VLAST’s nuclide detector,which accurately measures the charge signal of the photomultiplier tubes using the VATA160 applicationspecific integrated circuit chip;furthermore,we consider a series of critical problems,including radiation-hardening and environment monitoring.The test results show that the system exhibits stable operation,good performance,and good technical indicators.Furthermore,each electronic channel achieves a dynamic range of 0-12.5 pC,the random noise level exceeds 1.6 fC,and the integral nonlinearity exceeds 0.35%.展开更多
The perovskite photodetectors can be used for image sensing, environmental monitoring, optical communication, and chemical/biological detection. In the recent five years, the perovskite photoelectric detectors with va...The perovskite photodetectors can be used for image sensing, environmental monitoring, optical communication, and chemical/biological detection. In the recent five years, the perovskite photoelectric detectors with various devices are welldesigned and have made unprecedented progress of light detection. It is necessary to emphasize the most interesting works and summarize them to provide researchers with systematic information. In this review, we report the recent progress in perovskite photodetectors, including highly sensitive, ultrafast response speed, high gain, low noise, flexibility, and narrowband, concentrating on the photodetection performance of versatile halide perovskites(organic–inorganic hybrid and all inorganic compositions). Currently, organic–inorganic hybrid and all-inorganic halide microcrystals with polycrystalline film, nanoparticle/wire/chip, and block monocrystalline morphology control show important performance in response rate,decomposition rate, noise equivalent power, linear dynamic range, and response speed. It is expected that a comprehensive compendium of the research status of perovskite photodetectors will contribute to the development of this area.展开更多
Objective To analyse the antinociceptive effect of red nucleus (RN) and its role in the antinociceptive effect of muscle spindle afferents. Methods The single units of RN or wide dynamic range (WDR) neuron in the sp...Objective To analyse the antinociceptive effect of red nucleus (RN) and its role in the antinociceptive effect of muscle spindle afferents. Methods The single units of RN or wide dynamic range (WDR) neuron in the spinal cord dorsal horn were extracelluarly recorded. The effects of RN stimulation on nociceptive responses (C fibers evoked responses, C responses) of WDR neurons were observed. The influence of muscle spindle afferents elicited by intravenous administration of succinylcholine (Sch) on the spontaneous discharge of RN neurons and on C responses of WDR neurons were observed. The effect of muscle spindle afferents on C responses of WDR neurons after unilateral lesions of RN was also observed. Results Electrical stimulation of the RN produced a significantly inhibitory effect on the nociceptive responses of WDR neurons. RN neurons were excited by muscle spindle afferents. Muscle spindle afferents significantly inhibited C response of WDR neurons and this inhibitory effect was reduced by lesions of RN. Conclusion RN neurons have a significant antinociceptive effect and might be involved in the antinociceptive effects elicited by muscle spindle afferents.展开更多
基金supported by National Natural Science Foundation of China (Grant No. 50675011)Doctoral Scientific Research Enabling Foundation of Henan University of Science and Technology,China (Grant No. 09001318)
文摘The rolling bearing friction torque which is characterized by its uncertainty and nonlinearity affects heavily the dynamic performance of a system such as missiles, spacecrafts and radars, etc. It is difficult to use the classical statistical theory to evaluate the dynamic evaluation of the rolling bearing friction torque for the lack of prior information about both probability distribution and trends. For this reason, based on the information poor system theory and combined with the correlation dimension in chaos theory, the concepts about the mean of the dynamic fluctuant range (MDFR) and the grey relation are proposed to resolve the problem about evaluating the nonlinear characteristic and the dynamic uncertainty of the rolling bearing friction torque. Friction torque experiments are done for three types of the rolling bearings marked with HKTA, HKTB and HKTC separately; meantime, the correlation dimension and MDFR are calculated to describe the nonlinear characteristic and the dynamic uncertainty of the friction torque, respectively. And the experiments reveal that there is a certain grey relation between the nonlinear characteristic and the dynamic uncertainty of the rolling bearing friction torque, viz. MDFR will become the nonlinear increasing trend with the correlation dimension increasing. Under the condition of fewer characteristic data and the lack of prior information about both probability distribution and trends, the unitive evaluation for the nonlinear characteristic and the dynamic uncertainty of the rolling bearing friction torque is realized with the grey confidence level of 87.7%-96.3%.
基金Foundation of China (Nos. 12227805, U1831206, 12103095, 12235012, 12273120, and 11973097)the Scientific Instrument Developing Project of the Chinese Academy of Sciences (No. GJJSTD20210009)。
文摘In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-energy imaging calorimeter(HEIC) is currently being developed as a homogeneous calorimeter that utilizes long bismuth germanate(BGO) scintillation crystals as both absorbers and detectors. To accurately measure the energy deposition in the BGO bar of HEIC, a highdynamic-range readout method using a silicon photomultiplier(SiPM) and multiphotodiode(PD) with different active areas has been proposed. A prototype readout system that adopts multichannel charge measurement ASICs was also developed to read out the combined system of SiPMs and PDs. Preliminary tests confirmed the feasibility of the readout scheme, which is expected to have a dynamic range close to 10~6.
基金supported by a grant from Beijing Municipal Commission of Science and Technology of China,No.Z151100000915070
文摘The capability of neurons to discriminate between intensity of external stimulus is measured by its dynamic range.A larger dynamic range indicates a greater probability of neuronal survival.In this study,the potential roles of adaptation mechanisms(ion currents) in modulating neuronal dynamic range were numerically investigated.Based on the adaptive exponential integrate-and-fire model,which includes two different adaptation mechanisms,i.e.subthreshold and suprathreshold(spike-triggered) adaptation,our results reveal that the two adaptation mechanisms exhibit rather different roles in regulating neuronal dynamic range.Specifically,subthreshold adaptation acts as a negative factor that observably decreases the neuronal dynamic range,while suprathreshold adaptation has little influence on the neuronal dynamic range.Moreover,when stochastic noise was introduced into the adaptation mechanisms,the dynamic range was apparently enhanced,regardless of what state the neuron was in,e.g.adaptive or non-adaptive.Our model results suggested that the neuronal dynamic range can be differentially modulated by different adaptation mechanisms.Additionally,noise was a non-ignorable factor,which could effectively modulate the neuronal dynamic range.
文摘A 2.4GHz 0.18μm CMOS gain-switched single-end Low Noise Amplifier (LNA) and a passive mixer with no external balun for near-zero-IF (Intermediate Frequency)/RF (Radio Frequency) applications are described. The LNA, fabricated in the 0.18μm 1P6M CMOS technology, adopts a gain-switched technique to increase the linearity and enlarge the dynamic range. The mixer is an IQ-based passive topology. Measurements of the CMOS chip are performed on the FR-4 PCB and the input is matched to 50Ω. Combining LNA and mixer, the front-end measured performances in high gain state are: -15dB of Sll, 18.5dB of voltage gain, 4.6dB of noise figure, 15dBm of IIP3, 85dBm to -10dBm dynamic range. The full circuit drains 6mA from a 1.8V supply.
基金Project supported by the National Key R&D Program of China(Grant No.2018YFB2002405)the National Natural Science Foundation of China(Grant No.61903013)。
文摘Zero-field single-beam atomic magnetometers with transverse parametric modulation for ultra-weak magnetic field detection have attracted widespread attention recently.In this study,we present a comprehensive response model and propose a modification method of conventional first harmonic response by introducing the second harmonic correction.The proposed modification method gives improvement in dynamic range and reduction of linearity error.Additionally,our modification method shows suppression of response instability caused by optical intensity and frequency fluctuations.An atomic magnetometer with single-beam configuration is built to compare the performance between our proposed method and the conventional method.The results indicate that our method’s magnetic field response signal achieves a 5-fold expansion of dynamic range from 2 nT to 10 nT,with the linearity error decreased from 5%to 1%.Under the fluctuations of 5%for optical intensity and±15 GHz detuning of frequency,the proposed modification method maintains intensityrelated instability less than 1%and frequency-related instability less than 8%while the conventional method suffers 15%and 38%,respectively.Our method is promising for future high-sensitive and long-term stable optically pumped atomic sensors.
基金This work is financially supported by the NSFC grant of 21475030the S&T Research Project of Anhui Province15czz03109the National 10000 Talents-Youth Top-notch Talent Program.
文摘We report the design of a sensitive,electrochemical aptasensor for detection of ochratoxin A(OTA)with an extraordinary tunable dynamic sensing range.This electrochemical aptasensor is constructed based on the target induced aptamer-folding detection mechanism and the recognition between OTA and its aptamers results in the conformational change of the aptamer probe and thus signal changes for measurement.The dynamic sensing range of the electrochemical aptasensor is successfully tuned by introduction of free assistant aptamer probes in the sensing system.Our electrochemical aptasensor shows an extraordinary dynamic sensing range of 11-order magnitude of OTA concentration from 10^−8 to 10^2 ng/g.Of great significance,the signal response in all OTA concentration ranges is at the same current scale,demonstrating that our sensing protocol in this research could be applied for accurate detections of OTA in a broad range without using any complicated treatment of signal amplification.Finally,OTA spiked red wine and maize samples in different dynamic sensing ranges are determined with the electrochemical aptasensor under optimized sensing conditions.This tuning strategy of dynamic sensing range may offer a promising platform for electrochemical aptasensor optimizations in practical applications.
基金Project supported by the National Natural Science Foundation of China(Grant No.11675096)the Fundamental Research Funds for the Central Universities of China(Grant No.GK201702001)the Fund for the Academic Leaders and Academic Backbones,Shaanxi Normal University of China(Grant No.16QNGG007)
文摘Effects of refractory period on the dynamical range in excitable networks are studied by computer simulations and theoretical analysis. The first effect is that the maximum or peak of the dynamical range appears when the largest eigenvalue of adjacent matrix is larger than one. We present a modification of the theory of the critical point by considering the correlation between excited nodes and their neighbors, which is brought by the refractory period. Our analysis provides the interpretation for the shift of the peak of the dynamical range. The effect is negligible when the average degree of the network is large. The second effect is that the dynamical range increases as the length of refractory period increases, and it is independent of the average degree. We present the mechanism of the second effect. As the refractory period increases,the saturated response decreases. This makes the bottom boundary of the dynamical range smaller and the dynamical range extend.
文摘Distortion-free data embedding is a technique which can assure that not only the secret data is correctly extracted but also the cover media is recovered without any distortion after secret data is extracted completely. Because of these advantages, this technique attracts the attention of many researchers. In this paper, a new distortion-free data embedding scheme for high dynamic range (HDR) images is proposed. By depending on Cartesian product, this scheme can obtain higher embedding capacity while maintaining the exactly identical cover image and stego image when using the tone mapping algorithms. In experimental results, the proposed scheme is superior to Yu et aL's scheme in regard to the embedding rate——an average embedding rate of 0.1355 bpp compared with Yn et aL's scheme (0.1270 bpp).
文摘Objective: To study the effects of clinical concentration of sevoflurane on activity of wide dynamic range neurons. Methods: Eight Spraque-Dawley rats(male) were selected. Their spinal cords were exposed and transected at T 9-10 level. The rate of firings of single neurons in the dorsal horn in response to electrical stimulation of skin was recorded with microelectrodes. The early and late discharges were observed when rats inhaled 0.5%, 1.0%, 1.5%, and 2.0% sevoflurane. Results: Sevoflurane suppressed the early and late discharges at the concentration of 0.5%, 1.0%, 1.5%, and 2.0%. Compared with early discharges, the extent of inhibition of late discharges was wider at the concentration of 1%, 1.5%, and 2.0% of sevoflurane. Conclusion: It is indicated that sevoflurane could suppress the transmission of nociceptive and non-nociceptive stimulation at dorsal horn. The suppression on nociceptive imput is stronger than that on non-nociceptive imput when the concentration of sevoflurane is more than 1%.
文摘For the optimization of dynamic range and bandwidth of digital intermediate frequency receiver(DIFR), main factors affecting them and their relationships are studied. Firstly, the DIFR sensitivity, bandwidth, noise factor of radio frequency (RF) analog front-end (RFAF), and processing gain of intermediate frequency(IF) sampling are analyzed. Secondly, the constraint relationship of the noise factor of RFAF, the signal-to-noise ratio of ADC and the dynamic range of DIFR are studied. The relationship between the dynamic range and the RFAF gain, and that of the extended dynamic range and the RF AGC(automatic gain control) step are educed and simulated. These results can be used as theory foundations and design references for the implementation and optimization of the large dynamic range and wideband DIFR.
文摘Radio Frequency (RF) switch circuit is the basic part of microwave devices and systems. The non-linearity distortion figure is necessary in the field of large dynamic range of signal. This letter analyzes the basic switch circuit and its inter-modulation, and studies in detail the measurement methods and systems of RF switch intercept point. It has provided cascaded simulation testing methods, which can accurately measure the PF switch, of which the second or third order intercept point value is above 75dB and 60dB, respectively. As the testing results are consistent with the theoretical analyses, it proves that the validity of the method satisfies the requirements of large scaled linearity measurement in engineering.
基金Supported by the National Natural Science Foundation of China(No.61308099,61304032)
文摘Due to the existing limited dynamic range a camera cannot reveal all the details in a high-dynamic range scene. In order to solve this problem,this paper presents a multi-exposure fusion method for getting high quality images in high dynamic range scene. First,a set of multi-exposure images is obtained by multiple exposures in a same scene and their brightness condition is analyzed. Then,multi-exposure images under the same scene are decomposed using dual-tree complex wavelet transform( DT-CWT),and their low and high frequency components are obtained. Weight maps according to the brightness condition are assigned to the low components for fusion. Maximizing the region Sum Modified-Laplacian( SML) is adopted for high-frequency components fusing. Finally,the fused image is acquired by subjecting the low and high frequency coefficients to inverse DT-CWT.Experimental results show that the proposed approach generates high quality results with uniform distributed brightness and rich details. The proposed method is efficient and robust in varies scenes.
基金National Natural Science Foundation of China (60406003)Natural Science Foundation of Tianjin(08JCZDJC24100)
文摘The logarithmic response complementary metal oxide semiconductor (CMOS) image sensor provides a wide dynamic range, but its drawback is the lack of simple fixed pattern noise(FPN) cancellation scheme. Designed is a novel logarithmic active pixel sensor(APS) with high dynamic range and high output swing. Firstly, the operation principle of mixed-model APS is introduced. The pixel can work in three operation modes by choosing the proper control signals. Then, FPN sources of logarithmic APS are analyzed, and double-sampled technique is implemented to reduce FPN. Finally, according to the simulation results, layout is designed and has passed design rule check(DRC), electronic rule eheck(ERC) and layout versus schematic(LVS) verifications, and the post-simulation results are basically in agreement with the simulation results. Dynamic range of the new logarithmic APS can reach about 140 dB; and the output swing is about 750 inV. Results show that by using double sampled technique, most FPN is eliminated and the dynamic range is enhanced.
基金the National Basic Research Program of China(No.2006CB303105)
文摘An effective method for object shape recovery using HDRIs (high dynamic range images) is proposed. The radiance values of each point on the reference sphere and target object are firstly calculated, thus the set of candidate normals of each target point are found by comparing its radiance to that of each reference sphere point. In single-image shape recovery, a smoothness operation is applied to the target normals to obtain a stable and reasonable result; while in photometric stereo, radiance vectors of reference and target objects formed due to illuminations under different fight source directions are directly compared to get the most suitable target normals. Finally, the height values can be recovered from the resulting normal field. Because diffuse and specular reflection are handled in an unified framework with radiance, our approach eliminates the limitation presented in most recovery strategies, i.e., only Lambertian model can be used. The experiment results from the real and synthesized images show the performance of our approach.
文摘In Electronic Warfare (EW) receivers, the desired Dynamic Range (DR) often far exceeds the dynamic range attainable with available Analog-to-Digital Converter (ADC) technology. ADC is the key bottleneck in achieving the needed dynamic range. In this paper, an approach for improving the effective DR by utiliTing multiple amplifiers is presented. The amplifiers, arranged in parallel channels with different gains, can increase the dynamic range greatly.
文摘A novel charge exchanging compensation (CEC) technique is proposed for a wideband sample-and-hold (S/H) circuit applied in an IF sampling ADC. The CEC technique compensates the sampling bandwidth by eliminating the impact from finite on-resistance of the sampling switch, and avoids increasing clock feedthrough and charge injection. Meanwhile, a low power two stage OTA with a class AB output stage is designed to provide the S/H a 3Vp-p input range under 1.8V power. The S/H achieves a 94dB spurious-free dynamic range for a 200MHz input signal at a 100Ms/s sample rate and consumes only 26mW with a 5.5pF load.
基金supported by the National Natural Science Foundation of China(Nos.U2031206,U1831206,11975292,11875304)the Scientific Instrument Developing Project of the Chinese Academy of Sciences(No.GJJSTD20210009)+1 种基金the CAS“Light of West China”Programthe CAS Pioneer Hundred Talent Program。
文摘China plans to develop the next generation dark matter particle explorer satellite,referred to as the Very Large Area Space Telescope(VLAST).As an essential step in this process,the prototype design of detectors and electronics for the VLAST is currently underway.The nuclide detector is a core detector in the VLAST.It mainly measures nuclides’charges and distinguishes high-energy gamma rays and electrons.This paper will discuss the prototype readout electronics for the VLAST’s nuclide detector,which accurately measures the charge signal of the photomultiplier tubes using the VATA160 applicationspecific integrated circuit chip;furthermore,we consider a series of critical problems,including radiation-hardening and environment monitoring.The test results show that the system exhibits stable operation,good performance,and good technical indicators.Furthermore,each electronic channel achieves a dynamic range of 0-12.5 pC,the random noise level exceeds 1.6 fC,and the integral nonlinearity exceeds 0.35%.
基金Project supported by the International Cooperation and Exchange Project of Jilin Province,China(Grant Nos.20170414002GH and 20180414001GH)
文摘The perovskite photodetectors can be used for image sensing, environmental monitoring, optical communication, and chemical/biological detection. In the recent five years, the perovskite photoelectric detectors with various devices are welldesigned and have made unprecedented progress of light detection. It is necessary to emphasize the most interesting works and summarize them to provide researchers with systematic information. In this review, we report the recent progress in perovskite photodetectors, including highly sensitive, ultrafast response speed, high gain, low noise, flexibility, and narrowband, concentrating on the photodetection performance of versatile halide perovskites(organic–inorganic hybrid and all inorganic compositions). Currently, organic–inorganic hybrid and all-inorganic halide microcrystals with polycrystalline film, nanoparticle/wire/chip, and block monocrystalline morphology control show important performance in response rate,decomposition rate, noise equivalent power, linear dynamic range, and response speed. It is expected that a comprehensive compendium of the research status of perovskite photodetectors will contribute to the development of this area.
基金ThisresearchwassupportedbytheNationalNaturalScienceFoundationofChina (No .3 90 70 3 3 4)
文摘Objective To analyse the antinociceptive effect of red nucleus (RN) and its role in the antinociceptive effect of muscle spindle afferents. Methods The single units of RN or wide dynamic range (WDR) neuron in the spinal cord dorsal horn were extracelluarly recorded. The effects of RN stimulation on nociceptive responses (C fibers evoked responses, C responses) of WDR neurons were observed. The influence of muscle spindle afferents elicited by intravenous administration of succinylcholine (Sch) on the spontaneous discharge of RN neurons and on C responses of WDR neurons were observed. The effect of muscle spindle afferents on C responses of WDR neurons after unilateral lesions of RN was also observed. Results Electrical stimulation of the RN produced a significantly inhibitory effect on the nociceptive responses of WDR neurons. RN neurons were excited by muscle spindle afferents. Muscle spindle afferents significantly inhibited C response of WDR neurons and this inhibitory effect was reduced by lesions of RN. Conclusion RN neurons have a significant antinociceptive effect and might be involved in the antinociceptive effects elicited by muscle spindle afferents.