期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
A wearable real-time telemonitoring electrocardiogram device compared with traditional Holter monitoring 被引量:3
1
作者 Qin Shen Jianqing Li +4 位作者 Chang Cui Xingyao Wang Hongxiang Gao Chengyu Liu Minglong Chen 《The Journal of Biomedical Research》 CAS CSCD 2021年第3期238-246,共9页
Arrhythmias are very common in the healthy populations as well as patients with cardiovascular diseases.Among them,atrial fibrillation(AF)and malignant ventricular arrhythmias are usually associated with some clinical... Arrhythmias are very common in the healthy populations as well as patients with cardiovascular diseases.Among them,atrial fibrillation(AF)and malignant ventricular arrhythmias are usually associated with some clinical events.Early diagnosis of arrhythmias,particularly AF and ventricular arrhythmias,is very important for the treatment and prognosis of patients.Holter is a gold standard commonly recommended for noninvasive detection of paroxysmal arrhythmia.However,it has some shortcomings such as fixed detection timings,delayed report and inability of remote real-time detection.To deal with such problems,we designed and applied a new wearable 72-hour triple-lead H3-electrocardiogram(ECG)device with a remote cloud-based ECG platform and an expertsupporting system.In this study,31 patients were recruited and 24-hour synchronous ECG data by H3-ECG and Holter were recorded.In the H3-ECG group,ECG signals were transmitted using remote real-time modes,and confirmed reports were made by doctors in the remote expert-supporting system,while the traditional modes and detection systems were used in the Holter group.The results showed no significant differences between the two groups in 24-hour total heart rate(HR),averaged HR,maximum HR,minimum HR,premature atrial complexes(PACs)and premature ventricular complexes(PVCs)(P>0.05).The sensitivity and specificity of capture and remote automatic cardiac events detection of PACs,PVCs,and AF by H3-ECG were 93%and 99%,98%and 99%,94%and 98%,respectively.Therefore,the long-term limb triple-lead H3-ECG device can be utilized for domiciliary ECG self-monitoring and remote management of patients with common arrhythmia under medical supervision. 展开更多
关键词 wearable ecg device HOLTER REAL-TIME remote ecg monitoring
下载PDF
Evaluation of Pencil Lead Based Electrodes for Electrocardiogram Monitoring in Hot Spring 被引量:1
2
作者 Ratha Yeu Namhui Ra +1 位作者 Seong-A Lee Yunyoung Nam 《Computers, Materials & Continua》 SCIE EI 2021年第2期1411-1425,共15页
Electrocardiogram(ECG)electrodes are conductive pads applied to the skin to measure cardiac activity.Ag/AgCl electrodes are the commercial product which widely used to obtain ECGs.When monitoring the ECG in a hot spri... Electrocardiogram(ECG)electrodes are conductive pads applied to the skin to measure cardiac activity.Ag/AgCl electrodes are the commercial product which widely used to obtain ECGs.When monitoring the ECG in a hot spring,Ag/AgCl electrodes must be waterproofed;however,this is time-consuming,and the adhesive may tear the skin on removal.For solving the problem,we developed the carbon pencil lead(CPL)electrodes for use in hot springs.Both CPL and Ag/AgCl electrodes were connected to ECG100C’s cables.The Performance was evaluated in three conditions as following:hot spring water with and without bubble,and in cold water.In each environment,the procedure was followed by three different protocols that are recording from the dry condition,hot spring water immersion with and without movement,post hot spring water condition.Under dry and wet conditions,both electrodes can obtain the waveform of the ECG signal in which all PQRST waves were identifiable.Nevertheless,the signal quality of both types of electrodes was different in water immersion with and without movement.The overall morphology obtained by Ag/AgCl electrodes was unstable higher than that of CPL electrodes in immersion without movement condition.The CPL electrodes provided better ECG waveform quality compared to Ag/AgCl electrodes in which the ECG signal had high waveforms distortion in water immersion with movement condition. 展开更多
关键词 Carbon pencil lea ecg electrodes ecg monitoring hot spring water cold water hot spring water bubble
下载PDF
Monitoring Biosignals with Low Cost Wearable Sensors
3
作者 Filipe Oliveira1 Gil Goncalves Raquel Sousa 《Computer Technology and Application》 2013年第6期323-326,共4页
With the increase of aging population, we have been witnessing a decline in the quality of life influenced by numerous social, cultural and economic factors. Several studies have addressed these facts and some emergin... With the increase of aging population, we have been witnessing a decline in the quality of life influenced by numerous social, cultural and economic factors. Several studies have addressed these facts and some emerging technologies are capable of monitoring and anticipating these problems. With the advance in the development of smart textiles, it's possible to use these technologies in the acquisition of biosignals, which allows obtaining a better comfort regarding the use of smart clothes over traditional Ag/AgCI electrodes. In this way, it is possible to monitor for longer periods reducing the discomfort to the user. This paper reports the development of a low cost sensor with the capability of monitoring the electrical activity of the heart, measuring the heart rate and body temperature and is applied in the scenario: health & wellbeing, targeting the continuous measurement of vital signs. 展开更多
关键词 ecg (electrocardiogram) monitoring heart rate smart textile electrodes Ag/AgCI biosignals continuous monitoring.
下载PDF
Review on Development and Application of Fabric Electrodes in Electrocardiogram Monitoring Garments
4
作者 XIE Yutong ZAKARIA Norsaadah 《Journal of Donghua University(English Edition)》 CAS 2024年第5期482-491,共10页
Cardiovascular disease persists as the primary cause of human mortality,significantly impacting healthy life expectancy.The routine electrocardiogram(ECG)stands out as a pivotal noninvasive diagnostic tool for identif... Cardiovascular disease persists as the primary cause of human mortality,significantly impacting healthy life expectancy.The routine electrocardiogram(ECG)stands out as a pivotal noninvasive diagnostic tool for identifying arrhythmias.The evolving landscape of fabric electrodes,specifically designed for the prolonged monitoring of human ECG signals,is the focus of this research.Adhering to the preferred reporting items for systematic reviews and meta-analyses(PRISMA)statement and assimilating data from 81 pertinent studies sourced from reputable databases,the research conducts a comprehensive systematic review and meta-analysis on the materials,fabric structures and preparation methods of fabric electrodes in the existing literature.It provides a nuanced assessment of the advantages and disadvantages of diverse textile materials and structures,elucidating their impacts on the stability of biomonitoring signals.Furthermore,the study outlines current developmental constraints and future trajectories for fabric electrodes.These insights could serve as essential guidance for ECG monitoring system designers,aiding them in the selection of materials that optimize the measurement of biopotential signals. 展开更多
关键词 fabric electrode electrocardiogram(ecg)monitoring conductive material fabric structure meta-analysis
下载PDF
Medium to long term prognoses in children with premature ventricular contractions: Follow-up analysis of 106 cases
5
作者 胡小龙 聂娜娜 +3 位作者 毛成刚 张冲 徐敏 李自普 《South China Journal of Cardiology》 CAS 2015年第1期20-27,共8页
Background Premature ventricular contractions (PVCs) are frequently seen in children. However, there are less systematic and longer following-up studies examining the prognosis of PVCs in children. The aim of this s... Background Premature ventricular contractions (PVCs) are frequently seen in children. However, there are less systematic and longer following-up studies examining the prognosis of PVCs in children. The aim of this study was to evaluate the medium to long term prognosis of PVCs in childhood and whether there is a differential prognosis in different primary diseases of PVCs. Methods This study reviewed the data of 106 pediatric patients (49F/57M, 7.5 _ 3.8 years) seen at the Affiliated Hospital of Qingdao University with the diagnosis of PVCs between 1999 and 2005. Data on demographics, clinical presentation, laboratory tests, and echocardiograms of patients were extracted from the available clinical records. Results A total of 35 (33.0%) children presented with PVCs due to myocarditis, 7(6.6%) due to cardiomyopathies, 7(6.6%) due to mitral valve prolapse (MVP), 10(9.4%) due to operation for congenital heart disease (O-CHD), 16(15.2%) due to left ventricular false tendons (LVFT), and 31(29.2%) due to unknown cause. Holter did not show PVCs during follow-up period in 100% of myocarditis patients, 57% of cardiomyopathy patients, 71% of MVP patients, 60% of O-CHD patients, 88% of LVFT patients, 87% of unknown cause patients. The PVCs disappeared in 93% of patients who did not use anti-arrhythmic drugs and in 76% of patients who used anti- arrhythmic drugs. There was no a significant difference in prognosis between myocardial nutrition combined with intravenous injection of immunoglobulin (IVIG) group and propafenone group. Conclusions PVCs caused by different primary diseases has a favorable prognosis in children. Usually, the PVCs will reduce even disappear during follow-up. The patients with PVCs due to myocarditis should be preferred use myocardial nutrient combined with IVIG. 展开更多
关键词 premature ventricular contractions CHILDREN 24 hour ambulatory ecg monitoring PROGNOSIS
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部