The ECT (eddy current test) system is in use for Nb surface quality control in many laboratories. This system can inspect Nb surthce quickly using high resolution probe. The ECT system for RAON's cavity was made wi...The ECT (eddy current test) system is in use for Nb surface quality control in many laboratories. This system can inspect Nb surthce quickly using high resolution probe. The ECT system for RAON's cavity was made with these features: it has a 3-axis acting probe movenlent system, it can inspect a big size of Nb sheet, which is 1,200 mm × 365 mm and it contains the analysis program that can show the result as a 2D and 3D images as well as the relative figure of the surface level. The standard sample was made with various sizes of defects using the same Nb sheet that was used to make RISP (Rare Isotope Science Project) cavity. The ECT system conditioning was carried out to optimize the ECT operation on the frequency of which the range is from 300 KHZ to 2 MHz. The result of 900 KHZ showed the strongest signal. The conditioning experiment on other parameter will be carried out in the near future.展开更多
An SPECT system dedicated to small animal imaging shall be of a millimeter spatial resolution or even better.This study was aimed at achieving 0.5-mm spatial resolution for a small animal SPECT system at low cost.It w...An SPECT system dedicated to small animal imaging shall be of a millimeter spatial resolution or even better.This study was aimed at achieving 0.5-mm spatial resolution for a small animal SPECT system at low cost.It was developed from a single-head clinical SPECT scanner,with a seven-pinhole collimator and a four-degree-offreedom motion control stage.Several key techniques were developed,including high-resolution image reconstruction algorithm,high accuracy geometrical calibration method,and optimized system matrix derivation scheme.The system matrix was derived from Monte-Carlo simulation and de-noised by fitting each point spread function to a two dimensional Gaussian function.Experiments of point source and ultra micro hot rod phantom were conducted.With a spatial resolution of 0.5-0.6 mm,this system provides a practical way for low-cost high-resolution animal imaging on a clinic SPECT system.展开更多
Electrocatalytic glucose oxidation reaction(GOR)has attracted much attention owing to its crucial role in biofuel cell fabrication.Herein,we load MoO_(3)nanoparticles on carbon nanotubes(CNTs)and use a discharge proce...Electrocatalytic glucose oxidation reaction(GOR)has attracted much attention owing to its crucial role in biofuel cell fabrication.Herein,we load MoO_(3)nanoparticles on carbon nanotubes(CNTs)and use a discharge process to prepare a noblemetal-free MC-60 catalyst containing MoO_(3),Mo_(2)C,and a Mo_(2)C–MoO_(3)interface.In the GOR,MC-60 shows activity as high as 745μA/(mmol/L cm^(2)),considerably higher than those of the Pt/CNT(270μA/(mmol/L cm^(2)))and Au/CNT catalysts(110μA/(mmol/L cm^(2))).In the GOR,the response minimum on MC-60 is as low as 8μmol/L,with a steady-state response time of only 3 s.Moreover,MC-60 has superior stability and anti-interference ability to impurities in the GOR.The better performance of MC-60 in the GOR is attributed to the abundant Mo sites bonding to C and O atoms at the MoO_(3)–Mo_(2)C interface.These Mo sites create active sites for promoting glucose adsorption and oxidation,enhancing MC-60 performance in the GOR.Thus,these results help to fabricate more effi cient noble-metal-free catalysts for the fabrication of glucose-based biofuel cells.展开更多
Recent studies have highlighted the increase in treatment resistant depression. Of particular concern is the rising trend of depression and suicide rates among Young Adults. Ketamine was approved for treatment resista...Recent studies have highlighted the increase in treatment resistant depression. Of particular concern is the rising trend of depression and suicide rates among Young Adults. Ketamine was approved for treatment resistant depression in 2019 by the US Food and Drug Administration. It received an additional indication for treatment of suicidality. While intranasal Ketamine is approved for depression, recent data about intravenous infusion of Ketamine in controlled inpatient settings has been promising. ECT has a long-standing trend for being used for resistant depression and recent comparison trials have revealed positive results when head-to-head comparisons are made with Ketamine. Future studies need to focus on patient selection and wherein treatment algorithm should Ketamine be selected as treatment modality.展开更多
Seismic force reduction factor(SFRF) spectra of shear-type multi-degree-of-freedom(MDOF) structures are investigated. The modified Clough model, capable of considering the strength-degradation/hardening and stiffnessd...Seismic force reduction factor(SFRF) spectra of shear-type multi-degree-of-freedom(MDOF) structures are investigated. The modified Clough model, capable of considering the strength-degradation/hardening and stiffnessdegradation, is adopted. The SFRF mean spectra using 102 earthquake records on a typical site soil type(type C) are constructed with the period abscissa being divided into three period ranges to maintain the peak features at the two sitespecific characteristic periods. Based on a large number of results, it is found that the peak value of SFRF spectra may also exist for MDOF, induced by large high-mode contributions to elastic base shear, besides the mentioned two peak values. The variations of the stiffness ratio λk and the strength ratio λF of the top to bottom story are both considered. It is found that the SFRFs for λF ≤λk are smaller than those for λF > λk. A SFRF modification factor for MDOF systems is proposed with respect to SDOF. It is found that this factor is significantly affected by the story number and ductility. With a specific λF(= λk0.75), SFRF mean spectra are constructed and simple solutions are presented for MDOF systems. For frames satisfying the strong column/weak beam requirement, an approximate treatment in the MDOF shear-beam model is to assign a post-limit stiffness 15%-35% of the initial stiffness to the hysteretic curve. SFRF spectra for MDOF systems with 0.2 and 0.3 times the post-limit stiffness are remarkably larger than those without post-limit stiffness. Thus, the findings that frames with beam hinges have smaller ductility demand are explained through the large post-limit stiffness.展开更多
The recalibration of electrical capacitance tomography (ECT) system is one of the key problems in keeping the system running steadily.However, for engineering application in solids/gas transport,online calibration can...The recalibration of electrical capacitance tomography (ECT) system is one of the key problems in keeping the system running steadily.However, for engineering application in solids/gas transport,online calibration can not be implemented and the data from this sensor may be unreliable due to the sensor pipe interior wall abrasion during pneumatic transport,so the solids concentration calculated from the reconstructed image based on these data will be highly inaccurate.The simulations show that, the inter-electrode relative capacitance variation of electrode pair spacing 1 is the most sensitive to the abrasion of sensor pipe interior wall, so this relative capacitance variation when the sensor is filled with air can be used as an indicator demanding offline system recalibration when the wall abrasion goes significant.Furthermore, while the pipe interior wall abrasion is not very serious, online correcting measured inter-electrode capacitance with wall capacitance variation can improve the accuracy of concentration calculation.展开更多
This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The desi...This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The design is based on optical-to-electrical power converters, solid-state diode lasers and optical fibers. Command signals are transmitted via the same up-fiber used to send power from secondary power supply to primary converter. The upward data transmission is completed during the brief interruption of power delivery without affecting steady power-supply. A simple comparator added to the primary converter can take the command data. Experimental results show that the fibers can provide reliable up-link for data transmission at 200 kb/s from the secondary to the primary converter. Based on the delivery system, the secondary converter can control three auxiliary channels to provide additional information. These monitoring channels are used in a time-multiplexing mode to provide information about the operation temperature, voltage and current at the remote unit for monitoring the ECT. This preventive maintenance or built-in test can increase reliability by giving early warning for necessary maintenance request.展开更多
Climate change can intensify drought in many regions of the world and lead to more frequent drought events or altered cycles of soil water status.Therefore,it is important to enhance the tolerance to drought and thus ...Climate change can intensify drought in many regions of the world and lead to more frequent drought events or altered cycles of soil water status.Therefore,it is important to enhance the tolerance to drought and thus health,vigor,and success of transplantation seedlings used in the forestry by modifying fertilization and promoting mycorrhization.Here,we sowed seeds of Japanese larch(Larix kaempferi)in 0.2-L containers with 0.5 g(low fertilization;LF)or 2 g(high fertilization;HF)of slow-release fertilizer early in the growing season.One month later,we irrigated seedlings with non-sterilized ectomycorrhizal inoculum(ECM)or sterilized solution(non-ECM),and after about 2 months,plants were either kept well watered(WW;500 mL water/plant/week)or subjected to drought(DR;50 mL water per plant/week)until the end of the growing season.HF largely stimulated plant growth and above-and belowground biomass production,eff ects that are of practical signifi cance,but caused a small decrease in stomatal conductance(Gs 390)and transpiration rate(E 390),which in practice is insignifi cant.ECM treatment resulted in moderate inhibition of seedling growth and biomass and largely canceled out the enhancement of biomass and foliar K content by HF.DR caused a large decrease in CO 2 assimilation,and enhanced stomatal closure and induced senescence.DR also largely depleted foliar Mg and enriched foliar K.Although DR caused a large decrease in foliar P content in LF,it moderately increased P in HF.Likewise,DR increased foliar K in HF but not in LF,and decreased foliar P in ECM plants but not in non-ECM plants.Conversely,ECM plants exhibited a large enrichment in foliar P under WW and had a lower water potential under DR when grown in LF.These results indicate that the drought tolerance and health and vigor of Japanese larch seedlings can be modifi ed by soil fertility and soil microorganisms.This study provides a basis for new multifactorial research programs aimed at producing seedlings of superior quality for forestation under climate change.展开更多
文摘The ECT (eddy current test) system is in use for Nb surface quality control in many laboratories. This system can inspect Nb surthce quickly using high resolution probe. The ECT system for RAON's cavity was made with these features: it has a 3-axis acting probe movenlent system, it can inspect a big size of Nb sheet, which is 1,200 mm × 365 mm and it contains the analysis program that can show the result as a 2D and 3D images as well as the relative figure of the surface level. The standard sample was made with various sizes of defects using the same Nb sheet that was used to make RISP (Rare Isotope Science Project) cavity. The ECT system conditioning was carried out to optimize the ECT operation on the frequency of which the range is from 300 KHZ to 2 MHz. The result of 900 KHZ showed the strongest signal. The conditioning experiment on other parameter will be carried out in the near future.
基金Supported by Specialized Research Fund for the Doctoral Program of Higher Education(SRFDP200800031071)National Natural Science Foundation of China (No.10975086)the National High Technology Research and Development Program of China(No.2006AA020802)
文摘An SPECT system dedicated to small animal imaging shall be of a millimeter spatial resolution or even better.This study was aimed at achieving 0.5-mm spatial resolution for a small animal SPECT system at low cost.It was developed from a single-head clinical SPECT scanner,with a seven-pinhole collimator and a four-degree-offreedom motion control stage.Several key techniques were developed,including high-resolution image reconstruction algorithm,high accuracy geometrical calibration method,and optimized system matrix derivation scheme.The system matrix was derived from Monte-Carlo simulation and de-noised by fitting each point spread function to a two dimensional Gaussian function.Experiments of point source and ultra micro hot rod phantom were conducted.With a spatial resolution of 0.5-0.6 mm,this system provides a practical way for low-cost high-resolution animal imaging on a clinic SPECT system.
基金supported by the National Natural Science Foundation of China(Nos.82170426 and 22078193)Double Thousand Plan of Jiangxi Province(Nos.461654,jxsq2019102052).
文摘Electrocatalytic glucose oxidation reaction(GOR)has attracted much attention owing to its crucial role in biofuel cell fabrication.Herein,we load MoO_(3)nanoparticles on carbon nanotubes(CNTs)and use a discharge process to prepare a noblemetal-free MC-60 catalyst containing MoO_(3),Mo_(2)C,and a Mo_(2)C–MoO_(3)interface.In the GOR,MC-60 shows activity as high as 745μA/(mmol/L cm^(2)),considerably higher than those of the Pt/CNT(270μA/(mmol/L cm^(2)))and Au/CNT catalysts(110μA/(mmol/L cm^(2))).In the GOR,the response minimum on MC-60 is as low as 8μmol/L,with a steady-state response time of only 3 s.Moreover,MC-60 has superior stability and anti-interference ability to impurities in the GOR.The better performance of MC-60 in the GOR is attributed to the abundant Mo sites bonding to C and O atoms at the MoO_(3)–Mo_(2)C interface.These Mo sites create active sites for promoting glucose adsorption and oxidation,enhancing MC-60 performance in the GOR.Thus,these results help to fabricate more effi cient noble-metal-free catalysts for the fabrication of glucose-based biofuel cells.
文摘Recent studies have highlighted the increase in treatment resistant depression. Of particular concern is the rising trend of depression and suicide rates among Young Adults. Ketamine was approved for treatment resistant depression in 2019 by the US Food and Drug Administration. It received an additional indication for treatment of suicidality. While intranasal Ketamine is approved for depression, recent data about intravenous infusion of Ketamine in controlled inpatient settings has been promising. ECT has a long-standing trend for being used for resistant depression and recent comparison trials have revealed positive results when head-to-head comparisons are made with Ketamine. Future studies need to focus on patient selection and wherein treatment algorithm should Ketamine be selected as treatment modality.
基金Supported by:National Key Research and Development Program of China under Grant No.2016YFC0701201
文摘Seismic force reduction factor(SFRF) spectra of shear-type multi-degree-of-freedom(MDOF) structures are investigated. The modified Clough model, capable of considering the strength-degradation/hardening and stiffnessdegradation, is adopted. The SFRF mean spectra using 102 earthquake records on a typical site soil type(type C) are constructed with the period abscissa being divided into three period ranges to maintain the peak features at the two sitespecific characteristic periods. Based on a large number of results, it is found that the peak value of SFRF spectra may also exist for MDOF, induced by large high-mode contributions to elastic base shear, besides the mentioned two peak values. The variations of the stiffness ratio λk and the strength ratio λF of the top to bottom story are both considered. It is found that the SFRFs for λF ≤λk are smaller than those for λF > λk. A SFRF modification factor for MDOF systems is proposed with respect to SDOF. It is found that this factor is significantly affected by the story number and ductility. With a specific λF(= λk0.75), SFRF mean spectra are constructed and simple solutions are presented for MDOF systems. For frames satisfying the strong column/weak beam requirement, an approximate treatment in the MDOF shear-beam model is to assign a post-limit stiffness 15%-35% of the initial stiffness to the hysteretic curve. SFRF spectra for MDOF systems with 0.2 and 0.3 times the post-limit stiffness are remarkably larger than those without post-limit stiffness. Thus, the findings that frames with beam hinges have smaller ductility demand are explained through the large post-limit stiffness.
文摘The recalibration of electrical capacitance tomography (ECT) system is one of the key problems in keeping the system running steadily.However, for engineering application in solids/gas transport,online calibration can not be implemented and the data from this sensor may be unreliable due to the sensor pipe interior wall abrasion during pneumatic transport,so the solids concentration calculated from the reconstructed image based on these data will be highly inaccurate.The simulations show that, the inter-electrode relative capacitance variation of electrode pair spacing 1 is the most sensitive to the abrasion of sensor pipe interior wall, so this relative capacitance variation when the sensor is filled with air can be used as an indicator demanding offline system recalibration when the wall abrasion goes significant.Furthermore, while the pipe interior wall abrasion is not very serious, online correcting measured inter-electrode capacitance with wall capacitance variation can improve the accuracy of concentration calculation.
基金Project supported by the National Natural Science Foundation of China (Grant No.50447006)
文摘This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The design is based on optical-to-electrical power converters, solid-state diode lasers and optical fibers. Command signals are transmitted via the same up-fiber used to send power from secondary power supply to primary converter. The upward data transmission is completed during the brief interruption of power delivery without affecting steady power-supply. A simple comparator added to the primary converter can take the command data. Experimental results show that the fibers can provide reliable up-link for data transmission at 200 kb/s from the secondary to the primary converter. Based on the delivery system, the secondary converter can control three auxiliary channels to provide additional information. These monitoring channels are used in a time-multiplexing mode to provide information about the operation temperature, voltage and current at the remote unit for monitoring the ECT. This preventive maintenance or built-in test can increase reliability by giving early warning for necessary maintenance request.
基金supported by JSPS KAKENHI Grant Number JP17F17102 (to EA and MK)Startup Foundation for Introducing Talent of Nanjing University of Information Science and Technology (NUIST)(No. 003080)the Jiangsu Distinguished Professor program of the People’s Government of Jiangsu Province
文摘Climate change can intensify drought in many regions of the world and lead to more frequent drought events or altered cycles of soil water status.Therefore,it is important to enhance the tolerance to drought and thus health,vigor,and success of transplantation seedlings used in the forestry by modifying fertilization and promoting mycorrhization.Here,we sowed seeds of Japanese larch(Larix kaempferi)in 0.2-L containers with 0.5 g(low fertilization;LF)or 2 g(high fertilization;HF)of slow-release fertilizer early in the growing season.One month later,we irrigated seedlings with non-sterilized ectomycorrhizal inoculum(ECM)or sterilized solution(non-ECM),and after about 2 months,plants were either kept well watered(WW;500 mL water/plant/week)or subjected to drought(DR;50 mL water per plant/week)until the end of the growing season.HF largely stimulated plant growth and above-and belowground biomass production,eff ects that are of practical signifi cance,but caused a small decrease in stomatal conductance(Gs 390)and transpiration rate(E 390),which in practice is insignifi cant.ECM treatment resulted in moderate inhibition of seedling growth and biomass and largely canceled out the enhancement of biomass and foliar K content by HF.DR caused a large decrease in CO 2 assimilation,and enhanced stomatal closure and induced senescence.DR also largely depleted foliar Mg and enriched foliar K.Although DR caused a large decrease in foliar P content in LF,it moderately increased P in HF.Likewise,DR increased foliar K in HF but not in LF,and decreased foliar P in ECM plants but not in non-ECM plants.Conversely,ECM plants exhibited a large enrichment in foliar P under WW and had a lower water potential under DR when grown in LF.These results indicate that the drought tolerance and health and vigor of Japanese larch seedlings can be modifi ed by soil fertility and soil microorganisms.This study provides a basis for new multifactorial research programs aimed at producing seedlings of superior quality for forestation under climate change.