期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
A Fusion Neutron Source Driven Sub-Critical Nuclear Energy System: A Way for Early Application of Fusion Technology 被引量:11
1
作者 吴宜灿 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第6期1085-1092,共8页
This paper proposes a sub-critical nuclear energy system driven by fusion neutron source, FDS, which can be used to transmute long-lived radioactive wastes and to produce fissile nuclear fuel as a way for early applic... This paper proposes a sub-critical nuclear energy system driven by fusion neutron source, FDS, which can be used to transmute long-lived radioactive wastes and to produce fissile nuclear fuel as a way for early application of fusion technology. The necessity and feasibility to develop that system in China are illustrated on the basis of prediction of the demand of energy source in the first half of the 21th century, the status of current fission energy supply and the progress in fusion technology in the world. The characteristics of fusion neutron driver and the potential for transmutation of long-lived nuclear wastes and breeding of fissile nuclear fuel in a blanket are analyzed. A scenario of development steps is proposed. 展开更多
关键词 A Way for early application of Fusion Technology A Fusion Neutron Source Driven Sub-Critical Nuclear Energy System
下载PDF
Early application of percutaneous neuromuscular electric stimulation in interfering motor function of limbs and difference in temperature of axilla of patients with ischemic stroke
2
作者 Zhenhui Jiang Siyi Yin Na Bi Xiang He Fang Qu 《Neural Regeneration Research》 SCIE CAS CSCD 2006年第2期188-189,共2页
BACKGROUND: Temperature of axilla could be affected due to motor dysfunction of limbs and neural changes of vessel after ischemic stroke. OBJECTIVE: To observe the effect of percutaneous neuromuscular electric stimu... BACKGROUND: Temperature of axilla could be affected due to motor dysfunction of limbs and neural changes of vessel after ischemic stroke. OBJECTIVE: To observe the effect of percutaneous neuromuscular electric stimulation (PNES) on difference in temperature of axilla and analyze the relationship between function of limbs and difference in temperature of axilla. DESIGN: Randomized grouping and controlled observation SETTING: Department of Neurology, General Hospital of Shenyang Military Area Command of Chinese PLA PARTICIPANTS: Sixty patients with ischemic stroke were selected from Neurological Department of General Hospital of Shenyang Military Area Command of Chinese PLA from January to June 2003. All cases were diagnosed with clinical diagnosis criteria of ischemic stroke established by the Fourth Chinese Classification of Cerebrovasular Disease and CT examination and received neuromuscular electric stimulation (NES). Patients were randomly divided into control group and treatment group with 30 in each group. METHODS: Control group: Patients received routinely neurological therapy. Treatment group: Except routine therapy, patients suffered from NES at 48 hours after hospitalization. NMT-91 NES equipment was used to stimulated injured limbs with low frequency once 30 minutes a day in total of 10 times a course, especially extensor muscle of upper limb and flexor muscle of lower limb. Prescription of hemiplegia was internally decided by equipment with the output frequency of 200 Hz. Intensity of electric output could cause muscle contraction. The therapy needed two or three courses. Temperature of bilateral axilla was measured every day to calculate the difference with the formula of (temperature of axilla on the injured side - temperature of axilla on the healthy side). Motor function of limbs was measured with FugI-Meyer Motor Assessment (FMA) during hospitalization and at 2 and 4 hours after hospitalization. Among 90 points, upper and lower limb function was 54, equilibrium function 10, sensory function 10, and motion of joint 16. The higher the scores were, the better the function was. Correlation of data was dealt with linear correlation analysis. MAIN OUTCOME MEASURES : Assessment and correlation between difference in temperature of axilla and motor function of injured limbs during hospitalization and at 2 and 4 weeks after hospitalization. RESULTS: All 60 patients with ischemic stroke were involved in the final analysis. ① Difference in temperature: Difference of 2 and 4 weeks after hospitalization was lower than that in control group and at just hospitalization [treatment group: (0.056±0.000), (0.024±0.003) ℃; control group: (0.250±0.001), (0.131 ±0.001)℃; hospitalization; (0.513±0.001) ℃, P 〈 0.05-0,01]. ② FMA scores: Scores of 2 and 4 weeks after hospitalization were higher than those in control group and at just hospitalization [treatment group; (43.50±15.09), (67.97 ±18.21) points; control group: (33.33 ±13.54), (40.87±19.34) points; hospitalization: (26.43 ±11.87) points, P 〈 0.05-0.01]. ③ Correlation: Difference in temperature of axilla was negative correlation with FMA scores (c=- -0.255 1, P 〈 0.05). CONCLUSION: ① PNES can accelerate recovery of limb function and decrease temperature of axilla of patients with ischemic stroke. ② The lower the difference in temperature is, the better the functional recovery is. 展开更多
关键词 lim early application of percutaneous neuromuscular electric stimulation in interfering motor function of limbs and difference in temperature of axilla of patients with ischemic stroke
下载PDF
The application of ultra-wide-field fundus autofluorescence in early metastatic choroidal tumor screening
3
作者 Pan-Pan Ye Jia Xu +2 位作者 Zhi-Tao Su Xiao-Yun Fang Ke Yao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第12期1978-1981,共4页
I am Dr.Ke Yao,from Eye Center,the Second Affiliated Hospital,School of Medicine,Zhejiang University,Hangzhou,China.I write to present three cases with metastatic choroidal tumor using an ultra-wide-field scanning las... I am Dr.Ke Yao,from Eye Center,the Second Affiliated Hospital,School of Medicine,Zhejiang University,Hangzhou,China.I write to present three cases with metastatic choroidal tumor using an ultra-wide-field scanning laser ophthalmoscope. 展开更多
关键词 IMAGE The application of ultra-wide-field fundus autofluorescence in early metastatic choroidal tumor screening FAF
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部