The protection of downstream concrete slab is a key issue for the stability of overflow earth-rock cofferdam. The coupling effect between bedding layer and concrete slab was taken into account when the stability of do...The protection of downstream concrete slab is a key issue for the stability of overflow earth-rock cofferdam. The coupling effect between bedding layer and concrete slab was taken into account when the stability of downstream concrete slab was researched. The characteristics of overflow and seepage over the downstream concrete slab were investigated when floodwater passes over the cofferdam. Firstly a limit equation of seepage failure for the bedding layer was derived with the consideration of geometric and mechanical factors, and a reliability model was established and numerically simulated. Then based on the reliability calculation for the bedding layer, the coupling effect between bedding layer and downstream concrete slab was analyzed. Under the most unfavorable pressure condition for the concrete slab, its instability criterion was put forward, which offers a structural design tool of downstream concrete slab for overflow earth-rock cofferdam. Compared with model tests, it shows that the model of reliability calculation of bedding layer and the stability analysis of downstream concrete slab are effective.展开更多
基金supported by the National Natural Science Foundation of China (Grant No. 50579056)the Joint Fund of Yalong River Hydropower Development Researchthe National Natural Science Foundation of China(Grant No. 50539120)
文摘The protection of downstream concrete slab is a key issue for the stability of overflow earth-rock cofferdam. The coupling effect between bedding layer and concrete slab was taken into account when the stability of downstream concrete slab was researched. The characteristics of overflow and seepage over the downstream concrete slab were investigated when floodwater passes over the cofferdam. Firstly a limit equation of seepage failure for the bedding layer was derived with the consideration of geometric and mechanical factors, and a reliability model was established and numerically simulated. Then based on the reliability calculation for the bedding layer, the coupling effect between bedding layer and downstream concrete slab was analyzed. Under the most unfavorable pressure condition for the concrete slab, its instability criterion was put forward, which offers a structural design tool of downstream concrete slab for overflow earth-rock cofferdam. Compared with model tests, it shows that the model of reliability calculation of bedding layer and the stability analysis of downstream concrete slab are effective.