期刊文献+
共找到273篇文章
< 1 2 14 >
每页显示 20 50 100
Review on Development and Application of Fabric Electrodes in Electrocardiogram Monitoring Garments
1
作者 XIE Yutong ZAKARIA Norsaadah 《Journal of Donghua University(English Edition)》 CAS 2024年第5期482-491,共10页
Cardiovascular disease persists as the primary cause of human mortality,significantly impacting healthy life expectancy.The routine electrocardiogram(ECG)stands out as a pivotal noninvasive diagnostic tool for identif... Cardiovascular disease persists as the primary cause of human mortality,significantly impacting healthy life expectancy.The routine electrocardiogram(ECG)stands out as a pivotal noninvasive diagnostic tool for identifying arrhythmias.The evolving landscape of fabric electrodes,specifically designed for the prolonged monitoring of human ECG signals,is the focus of this research.Adhering to the preferred reporting items for systematic reviews and meta-analyses(PRISMA)statement and assimilating data from 81 pertinent studies sourced from reputable databases,the research conducts a comprehensive systematic review and meta-analysis on the materials,fabric structures and preparation methods of fabric electrodes in the existing literature.It provides a nuanced assessment of the advantages and disadvantages of diverse textile materials and structures,elucidating their impacts on the stability of biomonitoring signals.Furthermore,the study outlines current developmental constraints and future trajectories for fabric electrodes.These insights could serve as essential guidance for ECG monitoring system designers,aiding them in the selection of materials that optimize the measurement of biopotential signals. 展开更多
关键词 fabric electrode electrocardiogram(ECG)monitoring conductive material fabric structure meta-analysis
下载PDF
多功能监护仪操作培训步骤与临床实际操作应用的现状调查分析
2
作者 贾平 汪世秀 +3 位作者 雷志琴 谢彩霞 范萍 雷花 《当代医学》 2024年第6期151-154,共4页
目的调查分析护士多功能监护仪操作培训步骤及临床实际操作应用的现状。方法采取方便抽样方法,对2020年9月来自四川、广西、重庆、北京、福建、云南、贵州、河南、江苏、黑龙江等全国20个省(自治区、直辖市)100余家二乙以上医院,参加中... 目的调查分析护士多功能监护仪操作培训步骤及临床实际操作应用的现状。方法采取方便抽样方法,对2020年9月来自四川、广西、重庆、北京、福建、云南、贵州、河南、江苏、黑龙江等全国20个省(自治区、直辖市)100余家二乙以上医院,参加中华护理学会重症专科护士培训的261名ICU护理人员进行问卷调查。共发放问卷261份,收回有效问卷261份,问卷有效回收率为100.0%。调查护理人员接受监护仪操作培训步骤及临床实际操作步骤情况及护理人员非抢救状态下单人操作心电监护(ECG)、无创血压(BP)监测、血氧饱和度监测(SPO2)耗时情况。结果65.5%的护理人员接受培训的首要步骤是进行ECG监测,24.9%接受培训的首要步骤是进行SPO2监测,9.6%的护理人员接受培训的首要步骤是进行无创BP监测;35.2%的护理人员接受培训步骤的顺序与实际操作步骤不一致;49.4%的护理人员在实际临床操作中是先进行SPO2监测而非ECG监测,且认为不管是培训还是实际操作应先进行SPO2监测。非抢救状态下单人操作ECG监测、无创BP监测、SPO2监测耗时分布比较差异有统计学意义(P<0.05);SPO2监测耗时<20s占比高于与ECG监测、无创BP监测,耗时20~40、41~60、61~80s占比低于ECG监测、无创BP监测,差异有统计学意义(P<0.05)。结论多功能监护仪操作培训主要步骤的先后顺序未规范,培训步骤顺序与临床实际操作存在脱节现象,建议监护仪操作培训流程应先进行SPO2监测,其次是ECG与无创BP监测。 展开更多
关键词 多功能监护仪 心电监测 血压测量 血氧饱和度监测 操作培训 实际操作
下载PDF
基于“5G+AI”技术的远程心电监测系统研究 被引量:1
3
作者 代文娟 冀峰 《中国现代医生》 2024年第7期94-96,共3页
为解决心血管疾病防控的难题,提高心血管疾病预防、诊断及治疗的时效性和精准性,基于5G通信和人工智能技术,搭建一个远程心电监测系统,包括患者心电数据采集和自动识别、医生远程诊疗等功能。此监测系统可远程不间断地实时采集并识别分... 为解决心血管疾病防控的难题,提高心血管疾病预防、诊断及治疗的时效性和精准性,基于5G通信和人工智能技术,搭建一个远程心电监测系统,包括患者心电数据采集和自动识别、医生远程诊疗等功能。此监测系统可远程不间断地实时采集并识别分析患者的心电数据,并将识别结果、结论反馈给医生和患者,为患者及时就医和医生诊疗提供意见和建议。该系统在心脏病患者的管理、突发心脏事件监测和早期心脏疾病筛查等方面具有一定的实用价值。 展开更多
关键词 心电监测 5G 人工智能 远程实时监测 自动诊断
下载PDF
低功耗可穿戴式心电监测系统
4
作者 张鹏 蒋明峰 李杨 《电子科技》 2024年第10期88-94,共7页
日常心电监测对预防心血管病具有重要意义,但医用心电监测系统成本高、操作复杂且不适用于居家心电监测,可穿戴设备忽视了噪声干扰问题,难以利用采集信号来分析诊断病情。文中设计了一种低功耗可穿戴式心电监测系统,该系统由电源管理模... 日常心电监测对预防心血管病具有重要意义,但医用心电监测系统成本高、操作复杂且不适用于居家心电监测,可穿戴设备忽视了噪声干扰问题,难以利用采集信号来分析诊断病情。文中设计了一种低功耗可穿戴式心电监测系统,该系统由电源管理模块、心电采集模块、数据处理模块和延时开关模块4部分组成,通过BMD101芯片采集人体心电信号,使用低功耗蓝牙芯片nrf52832将心电数据发送到移动端。针对信号中易引入的肌电干扰噪声问题,文中提出了基于变分模态分解(Variational Mode Decomposition,VMD)的去噪算法,利用非局部均值(Non-Local Mean,NLM)滤除心电信号中低频模态的噪声,离散小波(Discrete Wavelet Transform,DWT)阈值去噪算法消除心电信号的高频模态噪声,重构后的信号质量明显提高。实验结果证明,所提算法具有成本低、易便携和使用方便等特点,能够获取高质量的心电信号,满足用户的长程监测需求,解决了日常不方便监测心电和心电信号获取质量低的问题。 展开更多
关键词 可穿戴 心电监测 低功耗 心电去噪 蓝牙 变分模态分解 非局部均值 离散小波变换
下载PDF
水胶体敷料预防新生儿心电监护电极片致皮肤损伤的效果观察
5
作者 李兆子 《中国现代药物应用》 2024年第3期47-49,共3页
目的观察水胶体敷料预防新生儿心电监护电极片致皮肤损伤的效果。方法将开平市妇幼保健院2021年5月~2022年12月入院的112例新生儿按随机数字表分为对照组(n=56例,常规皮肤直接贴电极片)及观察组(n=56例,水胶体敷料皮肤保护膜贴敷后再贴... 目的观察水胶体敷料预防新生儿心电监护电极片致皮肤损伤的效果。方法将开平市妇幼保健院2021年5月~2022年12月入院的112例新生儿按随机数字表分为对照组(n=56例,常规皮肤直接贴电极片)及观察组(n=56例,水胶体敷料皮肤保护膜贴敷后再贴电极片),采用国际接触性皮炎研究组规定的标准对两组新生儿皮肤损伤进行评价,统计两组新生儿两侧的接触性皮炎发生率,比较两组新生儿两侧接触性皮炎发生时间差异,采用Wong-Banker面部表情量表评价两组新生儿揭除电极片的疼痛程度。结果观察组两侧接触性皮炎发生率为12.50%(7/56),明显低于对照组的55.36%(31/56)(χ^(2)=22.942,P=0.000<0.05)。观察组阳性新生儿两侧接触性皮炎发生时间明显晚于对照组(χ^(2)=13.102,P=0.000<0.05)。观察组新生儿揭除电极片时疼痛程度明显轻于对照组(Z=8.151,P=0.000<0.05)。结论水胶体敷料皮肤保护膜贴敷后再贴电极片的方式能够大大降低接触性皮炎的发生率,减少电极导致的皮肤损伤,最大限度保证患儿安全,同时能够减轻揭除电极片的痛苦,提高患儿生活质量。 展开更多
关键词 水胶体敷料 新生儿 心电监护电极片 皮肤损伤
下载PDF
机器人辅助心电信号监测及康复训练系统
6
作者 卢振利 朱健美 +6 位作者 单长考 刘燕 赵宇 Pencic Marko Cavic'Maja Ilieva Roumiana Mernik Marjan 《高技术通讯》 CAS 北大核心 2024年第5期535-544,共10页
在心电信号的基础上设计心脏康复训练系统,本文总结了机器人辅助心脏康复研究国内外现状,从心电监测、机器人辅助康复系统设计上进行阐述。在心电监测装置上实现上下位机通信,在机器人辅助系统设计中,通过使用Visual Studio、Coppeliasi... 在心电信号的基础上设计心脏康复训练系统,本文总结了机器人辅助心脏康复研究国内外现状,从心电监测、机器人辅助康复系统设计上进行阐述。在心电监测装置上实现上下位机通信,在机器人辅助系统设计中,通过使用Visual Studio、Coppeliasim及Kinect设备三者进行通信,控制仿真机器人完成康复动作并严格识别、判定患者康复动作合格程度,以此来帮助心脏病患者进行康复动作训练。 展开更多
关键词 心电监测 人机交互 心脏康复
下载PDF
心脏远程实时监护系统在心血管疾病患者中的应用效果分析
7
作者 江礼娟 何燕锋 +2 位作者 张舒 廖丽萍 李为真 《中国社区医师》 2024年第11期90-92,共3页
目的:探讨心脏远程实时监护系统在心血管疾病患者中的应用效果。方法:选取2022年9-12月于上海市第一人民医院嘉定医院使用心脏远程实时监护系统救治的207例心血管疾病患者作为研究对象,均进行常规12导联心电图(ECG)检查、12导联24 h动... 目的:探讨心脏远程实时监护系统在心血管疾病患者中的应用效果。方法:选取2022年9-12月于上海市第一人民医院嘉定医院使用心脏远程实时监护系统救治的207例心血管疾病患者作为研究对象,均进行常规12导联心电图(ECG)检查、12导联24 h动态心电图(Holter)检查、心脏远程监护仪(Holter 5000)检查,以临床综合诊断结果为“金标准”,比较三种检测方法心血管疾病检出情况以及对心血管疾病的诊断效能。结果:Holter 5000心肌缺血检出率高于ECG、 Holter,传导阻滞、心房扑动或心房颤动、室性早搏或室性心动过速检出率Holter 5000>Holter>ECG,Holter 5000、Holter房性早搏或房性心动过速高于ECG,差异有统计学意义(P<0.05);ECG、Holter心肌缺血检出率,Holter 5000、Holter房性早搏或房性心动过速检出率比较,差异无统计学意义(P>0.05)。Holter 5000诊断心血管疾病的灵敏度、特异度高于ECG、Holter,Holter诊断心血管疾病的特异度高于ECG,差异有统计学意义(P<0.05);ECG、Holter诊断心血管疾病的灵敏度比较,差异无统计学意义(P>0.05)。结论:心脏远程实时监护系统在心血管疾病患者中的应用效果显著,具有较高的灵敏度、特异度。 展开更多
关键词 心电图 24 h心电图 心脏远程实时监护系统
下载PDF
心电及血压指标在高血压合并左心室肥厚中的应用进展
8
作者 张希铃 王新康 《实用心电学杂志》 2024年第3期312-315,共4页
高血压是常见的心血管疾病,左心室肥厚(left ventricular hypertrophy,LVH)是其常见的并发症。心电及血压指标是临床上用于评估心血管疾病的常见指标。近年来,随着检测技术的进步,它们在评价LVH方面展现出重要的应用价值。本文综述心电... 高血压是常见的心血管疾病,左心室肥厚(left ventricular hypertrophy,LVH)是其常见的并发症。心电及血压指标是临床上用于评估心血管疾病的常见指标。近年来,随着检测技术的进步,它们在评价LVH方面展现出重要的应用价值。本文综述心电及血压指标在LVH中的临床应用进展,并对未来的研究趋势进行展望。 展开更多
关键词 高血压 左心室肥厚 心电图 动态心电图 动态血压监测
下载PDF
动态心电图联合心率变异参数定量在诊断心电图ST-T改变中的价值
9
作者 李琴 《中华养生保健》 2024年第16期186-189,共4页
目的探究动态心电图联合心率变异参数在诊断心电图ST-T改变中的应用价值。方法选择2020年7月—2023年4月于陕西省森林工业职工医院接受体格检查的170人作为研究对象,对入组研究对象均开展心电图检查,按照其检测结果是否存在ST-T改变分... 目的探究动态心电图联合心率变异参数在诊断心电图ST-T改变中的应用价值。方法选择2020年7月—2023年4月于陕西省森林工业职工医院接受体格检查的170人作为研究对象,对入组研究对象均开展心电图检查,按照其检测结果是否存在ST-T改变分为研究组(n=85,存在心电图ST-T改变)和对照组(n=85,无心电图ST-T改变),分别对两组实施动态心电图检测,记录其心率变异性中定量参数相邻NN间期差值>50 ms研究对象所占的百分比(PNN50)、相邻NN间期差值的均方根(RMSSD)、所有窦性心律RR间期标准差(SDNN)后进行比较,通过绘制ROC曲线的方式判断动态心电图、心率变异定量参数以及联合检测对心电图ST-T诊断的价值。结果研究组动态心电图中的室上早及室上速均显著高于对照组,差异有统计学意义(P<0.05);动态心电图指标室上早和室上速对心电图ST-T改变的诊断AUC分别为0.873、0.856,诊断灵敏度为81.18%,特异度为76.65%,提示数据的一致性良好;研究组心率变异参数中的SDNN、RMSSD以及PNN50均显著高于对照组,差异有统计学意义(P<0.05);心率变异参数SDNN、RMSSD以及PNN50对心电图ST-T改变的诊断AUC分别为0.845、0.622、0.799,诊断灵敏度为83.53%、61.18%、74.12%,特异度为81.18%、52.95%、70.59%,提示SDNN、PNN50对心电图ST-T改变的诊断的一致性良好,而RMSSD有较低的一致性;采用串联方式,计算显示,动态心电图联合心率变异参数对心电图ST-T改变诊断的一致性为95.88%,灵敏度为98.82%,特异度为92.94%。结论心电图ST-T改变患者的动态心电图参数及心率变异参数均会出现明显改变,将上述定量参数应用于心电图ST-T改变诊断中存在较好的临床效能,具有一定的临床应用价值。 展开更多
关键词 动态心电图 心率变异参数 心电图ST-T改变 诊断效能
下载PDF
心电监护报警设置半自动生成系统的研发及应用 被引量:4
10
作者 陈娟红 张帅 +3 位作者 全殷殷 谢菁 沈竹青 姚惠萍 《中华急危重症护理杂志》 CSCD 2023年第6期498-501,共4页
目的 研发心电监护报警设置半自动生成系统,并探讨其在ICU监护仪报警管理中的应用效果。方法 组建研发小组,开发心电监护报警设置半自动生成系统。2022年5月在浙江省杭州市某三级甲等医院ICU、急诊重症监护室、重症康复病区中应用,比较... 目的 研发心电监护报警设置半自动生成系统,并探讨其在ICU监护仪报警管理中的应用效果。方法 组建研发小组,开发心电监护报警设置半自动生成系统。2022年5月在浙江省杭州市某三级甲等医院ICU、急诊重症监护室、重症康复病区中应用,比较系统应用后(2022年5月-10月)与应用前(2022年1月-3月)监护仪报警设置的正确率以及临床护士对该系统的满意度。结果 应用心电监护报警设置半自动生成系统后,监护仪报警设置正确率(99.18%和98.14%)均高于实施前(93.05%),差异有统计学意义(P<0.05)。59名护士对该系统的满意度总分为(104.96±12.09)分。结论 心电监护报警设置半自动生成系统的使用有助于提高临床监护仪报警设置的正确率,护士对心电监护报警设置半自动生成系统满意度较高。 展开更多
关键词 心电监护 临床报警器 管理信息系统 危重病护理
下载PDF
Monitoring Biosignals with Low Cost Wearable Sensors
11
作者 Filipe Oliveira1 Gil Goncalves Raquel Sousa 《Computer Technology and Application》 2013年第6期323-326,共4页
With the increase of aging population, we have been witnessing a decline in the quality of life influenced by numerous social, cultural and economic factors. Several studies have addressed these facts and some emergin... With the increase of aging population, we have been witnessing a decline in the quality of life influenced by numerous social, cultural and economic factors. Several studies have addressed these facts and some emerging technologies are capable of monitoring and anticipating these problems. With the advance in the development of smart textiles, it's possible to use these technologies in the acquisition of biosignals, which allows obtaining a better comfort regarding the use of smart clothes over traditional Ag/AgCI electrodes. In this way, it is possible to monitor for longer periods reducing the discomfort to the user. This paper reports the development of a low cost sensor with the capability of monitoring the electrical activity of the heart, measuring the heart rate and body temperature and is applied in the scenario: health & wellbeing, targeting the continuous measurement of vital signs. 展开更多
关键词 ECG electrocardiogram monitoring heart rate smart textile electrodes Ag/AgCI biosignals continuous monitoring.
下载PDF
Development of Portable Monitoring System for Real-Time Detection of Fetal Movement
12
作者 Qifeng Jiang Bin Gao Yang Li 《Advances in Bioscience and Biotechnology》 2018年第8期380-389,共10页
Effective fetal monitoring is an important guarantee for fetal health and early treatment. Fetal movement is one of critical indicators of fetal monitoring, which plays an important role in fetal health. Counting the ... Effective fetal monitoring is an important guarantee for fetal health and early treatment. Fetal movement is one of critical indicators of fetal monitoring, which plays an important role in fetal health. Counting the number of fetal movement by pregnant women is a traditional method for long-term monitoring. However, there are many defects in pregnant women’s feeling count, which cannot meet the accurate requirements of modern perinatal medicine. With the rapid development of biological and electronic technology, various sensors are used to probe the fetal dynamic monitoring, but not on fetal movement. This research proposes a monitoring method for fetal movement via three electrodes. Briefly: first, three electrodes are used to extract electrical signals in the abdomen of pregnant women;second, these signals are amplified and filtered;third, A/D converter with microprocessor is used to make analog digital conversion, which can be stored in the SD card under the control of the microprocessor;finally, the SD card data are processed by computer software and the fetal movement information is analyzed. 展开更多
关键词 FETAL MOVEMENT monitorING electrocardiogram ELECTRODE
下载PDF
远程心电监测用于诊断心律失常的临床意义 被引量:1
13
作者 张彩萍 王耀勇 张小飞 《实用检验医师杂志》 2023年第4期414-417,共4页
目的探讨远程心电监测对诊断冠心病合并心律失常患者的临床意义。方法选择2022年1月—2023年1月在山西省汾阳医院心内科就诊的200例冠心病患者作为研究对象,所有患者均进行普通12导联心电图检查和远程心电监测,比较并分析两种检查方法... 目的探讨远程心电监测对诊断冠心病合并心律失常患者的临床意义。方法选择2022年1月—2023年1月在山西省汾阳医院心内科就诊的200例冠心病患者作为研究对象,所有患者均进行普通12导联心电图检查和远程心电监测,比较并分析两种检查方法对诊断冠心病患者合并心律失常的检出率以及对心源性猝死的诊断结果。结果采用普通12导联心电图检出96例患者存在心律失常,检出率为48.00%(96/200),采用远程心电监测检出156例患者存在心律失常,检出率为78.00%(156/200),远程心电监测心律失常发生率明显高于普通12导联心电图(P<0.05)。远程心电监测对窦性心律失常、房性心律失常、室性心律失常的检出率均明显高于普通12导联心电图[窦性心律失常:26.00%(52/200)比15.00%(30/200),房性心律失常:23.00%(46/200)比13.50%(27/200),室性心律失常:16.00%(32/200)比9.50%(19/200),均P<0.05]。200例患者中发生心源性猝死21例,比较普通12导联心电图检查和远程心电监测对心源性猝死的诊断结果,远程心电监测对心源性猝死的诊断准确率明显高于普通12导联心电图检查(99.00%比93.00%,P<0.05)。结论远程心电监测能更及时准确诊断各种类型的心律失常,为冠心病合并心律失常患者的诊治提供了有力的证据。 展开更多
关键词 普通12导联心电图 远程心电监测 心律失常
下载PDF
品管圈在儿科外科重症监护病房护士心电监护仪报警疲劳中的应用 被引量:1
14
作者 施倩倩 侍玲 周春蕾 《妇儿健康导刊》 2023年第13期151-153,I0001,共4页
目的探讨品管圈在儿科外科重症监护病房(SICU)护士心电监护仪报警疲劳中的应用效果。方法品管圈小组使用问卷星发放报警疲劳调查问卷,同时统计床边心电监护仪虚假报警,包括心率、呼吸、指脉氧和有创血压,得出苏州大学附属儿童医院SICU... 目的探讨品管圈在儿科外科重症监护病房(SICU)护士心电监护仪报警疲劳中的应用效果。方法品管圈小组使用问卷星发放报警疲劳调查问卷,同时统计床边心电监护仪虚假报警,包括心率、呼吸、指脉氧和有创血压,得出苏州大学附属儿童医院SICU心电监护仪虚假报警率为82.18%,SICU护士报警疲劳程度评分为(22.0±6.2)分,提示为重度报警疲劳。通过对现况进行原因分析,明确改善重点,思考并提出可行对策,改进心电监护仪操作、管理流程及制度。结果根据圈能力,将SICU护士心电监护仪虚假报警率目标值定为58.03%。改善后的临床调查发现,SICU心电监护仪虚假报警率降至56.00%,目标达成率为108.41%,进步率为31.86%。SICU护士报警疲劳程度评分降至(20.01±7.85)分,报警疲劳程度降至中度。结论品管圈可以有效降低SICU心电监护仪虚假报警率、减轻SICU护士心电监护仪报警疲劳程度,并将护理安全放在工作首位。 展开更多
关键词 品管圈 儿科外科重症监护病房 心电监护仪 报警疲劳
下载PDF
动态心电图与常规心电图诊断无症状性心肌缺血伴发心律失常的临床效果对比研究 被引量:12
15
作者 高国亮 严国平 +1 位作者 史亮亮 郭雪芬 《中国医学装备》 2023年第2期68-71,共4页
目的:比较动态心电图(Holter)与常规心电图(RECG)诊断无症状性心肌缺血(SMI)伴发心律失常的临床价值。方法:选择医院收治的240例SMI患者,经RECG检查后Holter连续监测24 h。比较两种检查方法的SMI检出率、SMI发作时心电图表现中的心率、S... 目的:比较动态心电图(Holter)与常规心电图(RECG)诊断无症状性心肌缺血(SMI)伴发心律失常的临床价值。方法:选择医院收治的240例SMI患者,经RECG检查后Holter连续监测24 h。比较两种检查方法的SMI检出率、SMI发作时心电图表现中的心率、ST段下移距离、心肌缺血持续时间以及心律失常检出率。结果:Holter和RECG对SMI的检出率分别为70.83%(170/240)和40.00%(96/240),两种方法比较差异有统计学意义(χ^(2)=15.726,P<0.05)。Holter检查的心率和心肌缺血持续时间均明显高于RECG检查,ST段下移距离明显低于RECG检查,差异均有统计学意义(t=19.284,t=7.532,t=16.738;P<0.05)。Holter对早发期室性心律失常、早发期房性心律失常的检出率均明显高于RECG,差异均有统计学意义(χ^(2)=8.947,χ^(2)=6.795;P<0.05)。结论:Holter能有效提高SMI伴发心律失常的检出率,能获得更加全面的心电参数,临床价值更高。 展开更多
关键词 无症状性心肌缺血(SMI) 心律失常 12导联 动态心电图(Holter)监测 常规心电图(RECG)
下载PDF
PDCA循环在提升心电监护仪调配周转率中的应用 被引量:2
16
作者 魏恒烨 《医疗装备》 2023年第14期28-30,共3页
为了通过PDCA循环提升心电监护仪的调配周转率,本研究运用鱼骨图和柏拉图分析总结心电监护仪调配周转率低的要因,并针对要因提出相应对策。实施后,心电监护仪调配周转率由11.83%提高至22.72%,增加92.05%。验证了PDCA循环可明显提升心电... 为了通过PDCA循环提升心电监护仪的调配周转率,本研究运用鱼骨图和柏拉图分析总结心电监护仪调配周转率低的要因,并针对要因提出相应对策。实施后,心电监护仪调配周转率由11.83%提高至22.72%,增加92.05%。验证了PDCA循环可明显提升心电监护仪的调配周转率。 展开更多
关键词 PDCA循环管理 心电监护仪 调配 提升 周转率
下载PDF
“ 求同存异,优势互补” 的心电图与心脏超声 被引量:2
17
作者 张兆国 孔令云 赵兰婷 《实用心电学杂志》 2023年第3期166-171,共6页
心电图与超声心动图均为心脏疾病的常规检查,在心脏疾病诊疗中各有独特的优势。心电图聚焦心脏跳动的节律、频率以及心电传导情况,而超声心动图擅长于显示心脏结构和形态(如心脏瓣膜)、各房室大小、血流速度和方向、心脏收缩及舒张期的... 心电图与超声心动图均为心脏疾病的常规检查,在心脏疾病诊疗中各有独特的优势。心电图聚焦心脏跳动的节律、频率以及心电传导情况,而超声心动图擅长于显示心脏结构和形态(如心脏瓣膜)、各房室大小、血流速度和方向、心脏收缩及舒张期的心室容积变化。在临床实践中,二者求同存异,优势互补。本文简要介绍了心电图和超声心动图的发明过程,重点阐述它们各自的临床应用优势,强调二者优势互补在临床实践中的重要作用。 展开更多
关键词 心电图 心电监护 超声心动图 组织多普勒成像技术 斑点追踪成像技术
下载PDF
高血压心肌缺血患者动态心电图联合24 h动态血压监测的价值 被引量:5
18
作者 周红梅 《中国当代医药》 CAS 2023年第13期80-83,共4页
目的分析动态心电图联合24 h动态血压监测在高血压心肌缺血中的监测效果。方法选择2020年8月至2021年8月北京航天总医院心血管内科收治的123例高血压心肌缺血患者为观察组,选择2019年7月至2020年7月收治的122例高血压心肌缺血患者为对照... 目的分析动态心电图联合24 h动态血压监测在高血压心肌缺血中的监测效果。方法选择2020年8月至2021年8月北京航天总医院心血管内科收治的123例高血压心肌缺血患者为观察组,选择2019年7月至2020年7月收治的122例高血压心肌缺血患者为对照组,两组患者均行动态血压监测及24 h动态心电图监测。观察两组患者心肌缺血发生率、昼夜收缩压(dSBP/nSBP)、昼夜舒张压(dDBP/nDBP)、昼夜心率(dHR/nHR)及ST段下移持续时间、下移幅度及心肌缺血阈变异性情况。结果观察组心肌缺血发生率高于对照组,差异有统计学意义(P<0.05)。观察组中有心肌缺血患者的dSBP低于无心肌缺血组患者,dHR、nSBP、nHR高于无心肌缺血组患者,差异有统计学意义(P<0.05)。对照组中,有心肌缺血组患者dSBP、nSBP低于无心肌缺血组患者,nHR高于无心肌缺血组患者,差异有统计学意义(P<0.05)。观察组有心肌缺血组患者的dSBP、nSBP高于对照组有心肌缺血组患者,差异有统计学意义(P<0.05)。观察组无心肌缺血组患者的dDBP、低于对照组无心肌缺血组患者,nSBP高于对照组无心肌缺血组患者,差异有统计学意义(P<0.05)。观察组白昼、夜间的ST段下移持续时间、下移幅度及心肌缺血阈变异性长于对照组,差异有统计学意义(P<0.05)。结论动态心电图、24 h动态血压监测联合应用可提高高血压心肌缺血诊断率,可同步观察患者心率、血压与心肌缺血间的关系,为临床诊治高血压心肌缺血提供有力依据。 展开更多
关键词 动态心电图 24 h时动态血压监测 高血压 心肌缺血
下载PDF
稳心颗粒与琥珀酸美托洛尔缓释片联合治疗对冠心病心律失常患者的影响
19
作者 赵涛 《中国医药指南》 2023年第2期122-124,共3页
目的 研究在为冠心病动态心电图监测结果心律失常患者实施治疗的过程中稳心颗粒与琥珀酸美托洛尔缓释片的应用效果。方法 本次试验研究的98例对象均随机选自于2018年3月至2019年3月在我院接受冠心病心律失常治疗的患者,采用动态随机单... 目的 研究在为冠心病动态心电图监测结果心律失常患者实施治疗的过程中稳心颗粒与琥珀酸美托洛尔缓释片的应用效果。方法 本次试验研究的98例对象均随机选自于2018年3月至2019年3月在我院接受冠心病心律失常治疗的患者,采用动态随机单双号分组原则将其分为两组,其中给予稳心颗粒与琥珀酸美托洛尔缓释片联合治疗的49例患者作为联合组,给予单一琥珀酸美托洛尔缓释片治疗的49例患者作为单一组。结果 联合组患者治疗有效率、并发症发生率分别为97.96%、4.08%;单一组患者治疗有效率、并发症发生率分别为85.71%、20.41%,在治疗有效率和并发症发生概率的比较上,联合组患者与单一组患者差异有统计学意义(P<0.05)。结论 在为冠心病心律失常患者实施治疗的过程中稳心颗粒与琥珀酸美托洛尔缓释片联合治疗方式的运用,可以提高治疗有效率与质量,避免了各种并发症出现对患者造成的影响,治疗效果显著且安全性高。 展开更多
关键词 冠心病心律失常 稳心颗粒 琥珀酸美托洛尔缓释片 动态心电图监测结果
下载PDF
动态心电监测对普萘洛尔治疗婴幼儿血管瘤后心律失常的诊断价值研究
20
作者 刘红芳 张燕 阳亮 《现代医药卫生》 2023年第24期4204-4206,4214,共4页
目的探讨动态心电监测对普萘洛尔治疗婴幼儿血管瘤后心律失常的诊断价值。方法选取2022年1-9月赣州市妇幼保健院小儿外科收治的婴幼儿血管瘤患儿100例作为研究对象,均给予普萘洛尔治疗。按数字表法将患儿随机分为动态心电图组50例和常... 目的探讨动态心电监测对普萘洛尔治疗婴幼儿血管瘤后心律失常的诊断价值。方法选取2022年1-9月赣州市妇幼保健院小儿外科收治的婴幼儿血管瘤患儿100例作为研究对象,均给予普萘洛尔治疗。按数字表法将患儿随机分为动态心电图组50例和常规心电图组50例,在服药前,服药2、5 d,4、12周时,分别采用24 h动态心电图或常规心电图进行心律失常监测。结果常规心电图组和动态心电图组总体上分别检测出经普萘洛尔治疗后发生心律失常的血管瘤患儿2例(4.0%)和12例(24.0%),两者比较,差异有统计学意义(P<0.05);在服药前,服药2、5 d和4周时,两组患儿的心律失常发生情况比较,差异无统计学意义(P>0.05);服药12周时,与常规心电图组相比,动态心电图组检出的心律失常患儿数量明显更多,差异有统计学意义(P<0.05)。结论随着采用普萘洛尔治疗婴幼儿血管瘤时长增加,患儿可出现心律失常不良反应,且动态心电图的检出率高于常规心电图,更具有临床诊断价值。 展开更多
关键词 婴幼儿血管瘤 动态心电监测 普萘洛尔 心律失常
下载PDF
上一页 1 2 14 下一页 到第
使用帮助 返回顶部