The self-excited second harmonic in radio-frequency capacitively coupled plasma was significantly enhanced by adjusting the external variable capacitor.At a lower pressure of 3 Pa,the excitation of the second harmonic...The self-excited second harmonic in radio-frequency capacitively coupled plasma was significantly enhanced by adjusting the external variable capacitor.At a lower pressure of 3 Pa,the excitation of the second harmonic caused an abnormal transition of the electron energy probability function,resulting in abrupt changes in the electron density and temperature.Such changes in the electron energy probability function as well as the electron density and temperature were not observed at the higher pressure of 16 Pa under similar harmonic changes.The phenomena are related to the influence of the second harmonic on stochastic heating,which is determined by both amplitude and the relative phase of the harmonics.The results suggest that the self-excited high-order harmonics must be considered in practical applications of lowpressure radio-frequency capacitively coupled plasmas.展开更多
The dual-frequency capacitively coupled plasma (DF-CCP) with inductive enhancement system is a newly designed plasma reactor. Different from the conventional inductively coupled plasma (ICP) reactors, now a radio ...The dual-frequency capacitively coupled plasma (DF-CCP) with inductive enhancement system is a newly designed plasma reactor. Different from the conventional inductively coupled plasma (ICP) reactors, now a radio frequency (rf) power is connected to an antenna placed outside the chamber with a one-turn bare coil placed between two electrodes in DF-CCP. This paper gives a detailed description of its structure of discharges in this apparatus were made via a Moreover, investigations on some characteristics Langmuir probe.展开更多
文摘The self-excited second harmonic in radio-frequency capacitively coupled plasma was significantly enhanced by adjusting the external variable capacitor.At a lower pressure of 3 Pa,the excitation of the second harmonic caused an abnormal transition of the electron energy probability function,resulting in abrupt changes in the electron density and temperature.Such changes in the electron energy probability function as well as the electron density and temperature were not observed at the higher pressure of 16 Pa under similar harmonic changes.The phenomena are related to the influence of the second harmonic on stochastic heating,which is determined by both amplitude and the relative phase of the harmonics.The results suggest that the self-excited high-order harmonics must be considered in practical applications of lowpressure radio-frequency capacitively coupled plasmas.
基金supported by ITER Project (Nos. 2010GB106000,2010GB106009) National Natural Science Foundation of China (Nos. 10975106, 11175126, 11075114, 11204266)+1 种基金 Qing Lan Project, the Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions The Program for Graduates Research &: Innovation in University of Jiangsu Province, China (No. CXZZ 11-0085)
文摘The dual-frequency capacitively coupled plasma (DF-CCP) with inductive enhancement system is a newly designed plasma reactor. Different from the conventional inductively coupled plasma (ICP) reactors, now a radio frequency (rf) power is connected to an antenna placed outside the chamber with a one-turn bare coil placed between two electrodes in DF-CCP. This paper gives a detailed description of its structure of discharges in this apparatus were made via a Moreover, investigations on some characteristics Langmuir probe.