期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
STUDY ON THE FALLING FILM ABSORPTION OUTSIDE SMOOTH AND ENHANCED TUBES 被引量:2
1
作者 WANG Mei-xia LIU Cun-fang +1 位作者 Wang Xin-guang ZHAO Bin 《Journal of Hydrodynamics》 SCIE EI CSCD 2006年第4期405-410,共6页
In this paper, mathematical models of smooth and enhanced tubes were established. A new mathematical model in evaluating single-tube falling film absorption effect outside enhanced tubes is proposed. The liquid film o... In this paper, mathematical models of smooth and enhanced tubes were established. A new mathematical model in evaluating single-tube falling film absorption effect outside enhanced tubes is proposed. The liquid film outside enhanced tubes is assumed to consist of two layers, i.e. internal and external layers. The analytical solutions to the distribution of the velocity, temperature and concentration in the internal layer are obtained by means of theoretical analysis, while the solutions in the external layer are calculated by using numerical method. The governing equations of the two layers are coupled using a second-order coupling method. The effects of the height and the angle of the ribs on the performances of the heat and mass transfer of the liquid film are discussed. It is shown that the agreement is good between the calculation results and the experimental data. 展开更多
关键词 heat and mass transfer mathematical model numerical calculation enhanced tube
原文传递
Effect of Pore Size on the Nucleate Pool Boiling of Structured Enhanced Tubes 被引量:1
2
作者 Nae-HyunKim Jong-WonKim 《Journal of Thermal Science》 SCIE EI CAS CSCD 2000年第3期230-235,共6页
In this study, pool boiling test results are provided for the structured enhanced tubes having pores with connecting gaps. The surface geometly of the present tube is similar to that of Turbo-B. Three tubes with diffe... In this study, pool boiling test results are provided for the structured enhanced tubes having pores with connecting gaps. The surface geometly of the present tube is similar to that of Turbo-B. Three tubes with different pore size (0.20 mm, 0.23 mm and 0.27 mm) were manufactured and tested using R-11, R-123 and R-134a. The pore size which yields the maximum heat transfer coefficient varied depending on the refrigerant. For R-134a, the maximum heat transfer coefficient was obtained for the tube having 0.27 nun pore size. For R-11 and R- 123, the optimum pore size was 0.23 mm. One novel feature of the present tubes is that their boiling curves do not show a cross-over characteristic, which existing pored tubes do. The connecting gaps of the present tube are believed to serve an additional route for the liquid supply and delay the dry-out of the tunnel. The present tubes yield the heat transfer coefficients approximately equal to those of the existing pored enhanced tubes. At the heat flux 40 kW/m2 and saturation temperature 4.4° C, the heat transfer coefficients of the present tubes are 6.5 times larger for R-11, 6.0 times larger for R-123 and 5.0 times larger for R-134a than that of the smooth tube 展开更多
关键词 structured enhanced tube PORE GAP nucleate pool boiling R-11 R-123 R-134a.
原文传递
Forming mechanism of integral serrated high fins by plowing-extruding based on variational feed 被引量:4
3
作者 万珍平 燕辉 汤勇 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2010年第3期400-404,共5页
Plowing-extruding tool was designed and plowing-extruding process was investigated.Then,a manufacturing method of integral serrated high-finned tube,plowing-extruding based on variational feed was proposed,in which pl... Plowing-extruding tool was designed and plowing-extruding process was investigated.Then,a manufacturing method of integral serrated high-finned tube,plowing-extruding based on variational feed was proposed,in which plowing-extruding tool moved forward at two different feeds,f1 and f2,in turn.In this method,overlaps that are usually avoided in practical application were utilized to manufacture high fins and average height of fins was up to 1.58 mm.The critical feed(fc) of overlaps forming and terms of high fins forming were analyzed.The main technical parameters that affect the fins height were discussed.The experimental results show that the fins height increases with extruding inclination angle and plowing-extruding depth,and the fins height increases with f1 increasing when f1 is smaller than fc,and decreases with f1 increasing if f1 is larger than fc. 展开更多
关键词 enhanced heat transfer tube integral serrated high fins plowing-extruding
下载PDF
Performance enhancement of filled-type solar collector with U-tube 被引量:1
4
作者 梁若冰 张吉礼 +1 位作者 赵亮 马良栋 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第3期1124-1131,共8页
In order to increase the efficiency of solar collector, a methodology is proposed based on the analysis of its influencing factors, such as thermal conductivity of filled layer, structure forms of filled layer and hea... In order to increase the efficiency of solar collector, a methodology is proposed based on the analysis of its influencing factors, such as thermal conductivity of filled layer, structure forms of filled layer and heat loss coefficient. The results of analysis show that the heat transfer between pipes in evacuated tube is one of the most important factors, which can lead to the decrease of the outlet temperature of working fluid. In order to eliminate the negative influence of the heat transfer between pipes, the hollow filled-type evacuated tube with U-tube(HUFET) was developed, and the heat transfer characteristics of HUFET were analyzed by theoretical and experimental studies. The results show that the thermal resistances decrease with the increase of the thermal conductivity of filled layer. When the thermal conductivity is over 10 W/(m·K), the change of thermal resistances is very little.Furthermore, the larger the thermal conductivity of filled layer, the less the rate of the energy transfer between the two pipes to the total energy transfer, which is between the absorber tube and the working fluid. There is a little difference between the efficiencies of HUFET and UFET, with the efficiency of HUFET 2.4% higher than that of UFET. Meanwhile, the validation of the model developed was confirmed by the experiment. 展开更多
关键词 performance enhancement filled-type evacuated tube U-tube