期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Establishment of Local Diagnostic Reference Levels in Conventional Radiography: A Pilot Study in Dakar, Senegal
1
作者 Adji Yaram Diop Magatte Diagne +1 位作者 Ndeye Arame Boye Faye Mamadou Moustapha Dieng 《World Journal of Nuclear Science and Technology》 2022年第1期28-42,共15页
Diagnostic Reference Levels (DRLs) are indicators that allow assessing the quality of equipment and procedures from the point of view of the doses delivered to patients and subsequently initiate corrective actions if ... Diagnostic Reference Levels (DRLs) are indicators that allow assessing the quality of equipment and procedures from the point of view of the doses delivered to patients and subsequently initiate corrective actions if necessary. The purpose of this study is to encourage health professionals to investigate patient radiation doses and to determine whether those doses comply with the principles of radiation protection in medical fields so as to improve practices by reducing patient exposure without reducing clinical effectiveness. To perform this work, we have investigated patient doses for different radiological examinations from six (6) medical centers in Dakar, including the following nine routine types: chest (PA), abdomen (AP), pelvis (AP), cervical spine (AP), lumbar spine (AP, Lat), hip (AP), thoracic spine (AP, Lat). Three types of data were collected, <em>i.e.</em>, X-ray tube machine data, patient data and output measurements. The data were analyzed statistically and the median, minimum, maximum, and third quartile values were calculated and displayed throughout boxplots graphs for all exams and medical centers. The two sigma range (95% confidence interval) was also checked. Comparison of third quartiles of Entrance Surface Dose (ESD) and Dose Area Product (DAP) by type of examination with recommended international DRLs was performed. The third quartile of ESD for pelvis (AP) and thoracic spine (AP) was up to 16% and 38% higher, respectively than their corresponding DRLs in the European Commission Report RP 180 Part 2. For all exams, except thoracic spine (lat), the third quartiles of the dose area product were higher than the corresponding DRLs in the above report. The source of dose variability between medical centers was related to many parameters such as poor radiographic techniques, lack of modern X-ray machines and adequately documented radiation protection practices. The results show the need to develop protocols for dose measurement as well as to carry out quality assurance programs and dose optimization in Senegal. 展开更多
关键词 entrance surface dose Diagnostic Radiology dose Area Product Optimization X-Rays
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部