Selecting the optimal one from similar schemes is a paramount work in equipment design.In consideration of similarity of schemes and repetition of characteristic indices,the theory of set pair analysis(SPA)is proposed...Selecting the optimal one from similar schemes is a paramount work in equipment design.In consideration of similarity of schemes and repetition of characteristic indices,the theory of set pair analysis(SPA)is proposed,and then an optimal selection model is established.In order to improve the accuracy and flexibility,the model is modified by the contribution degree.At last,this model has been validated by an example,and the result demonstrates the method is feasible and valuable for practical usage.展开更多
With the development of electronic equipment to high accuracy, high density, high frequency, and atrocious ser- vice environment, the functional surface in this type of equipment has increasingly serious problems,
Characteristic period is an important parameter of the seismic design response spectrum. There is important theoretical significance and engineering application value to the study of the characteristic period of seism...Characteristic period is an important parameter of the seismic design response spectrum. There is important theoretical significance and engineering application value to the study of the characteristic period of seismic design response spectrum of ultra high voltage (UHV) electrical equipment. In this paper, 1448 horizontal earthquake records within the world scope including the United States and Japan for Site Class m were analyzed. Results show that both magnitude and epicentral distance have great influence on the characteristic period. About 80 % of characteristic periods of strong earthquake records are about 0. 9s. Statistical analysis was conducted on the seismic hazard assessment results of 312 projects of China in recent years, and it is found that about 70 % of characteristic periods are about 0. 9s. Combined with the related code comparison and analysis, it is suggested that the characteristic period of the seismic design response spectrmn of UHV electrical equipment should select 0. 9s in order to effectively guarantee the seismic safety of UHV electrical equipment.展开更多
Since the excessive capacity in steelmaking and continuous casting at present,and the limited development margin of CC technology and equipment in scale,the further development must be made in a profound and detailize...Since the excessive capacity in steelmaking and continuous casting at present,and the limited development margin of CC technology and equipment in scale,the further development must be made in a profound and detailized way.This paper enumerates the items of CC technology and equipment,which need to be detailized from several aspects such as roll arrangement design,equipment design and production operation,and it points out that detailization is the future direction of CC technology and equipment.The items in roll arrangement design include eliminating periodic meniscus fluctuation by adjusting space between rolls reasonably;taking special measures to avoid dangerous regions of casting speed,in order to reduce the center porosity and centerline crack of slab;optimizing the major radius and the length of outer arc of caster before straightening point to avoid dangerous region of casting speed.The items in equipment design include choosing a suitable structure of support and guiding roll according to the concrete conditions of caster;according to bulging shape of slab,thinking more about restriction of shell to bulging force, discussing the force on rollers,optimizing split roll to support slab;safety factor should be considered together with calculation method of the bearing nominal static load.The items in aspects of continuous casting operation include the delicacy division and the function-positioning of operation modes for CC machine due to the consideration of dynamic soft reduction;monitoring and controlling system of CC machine must be further detailized to improve the stability of production operation and slab quality.In addition to the three aspects mentioned above,this article points out many other items also,such as homogenization of secondary cooling of slab,quality control of surface and internal of slab,and so on.This article emphasizes,some key technologies need to be researched also,and all these researches will never stop.展开更多
Traffic management in underground mines,especially on production ramps,is a difficult problem to optimize and control.Most operations use one of a few common policies;e.g.,the so-called ‘‘lock-out" and‘‘loade...Traffic management in underground mines,especially on production ramps,is a difficult problem to optimize and control.Most operations use one of a few common policies;e.g.,the so-called ‘‘lock-out" and‘‘loaded-vehicle-priority" policies.The work presented in this paper uses discrete-event simulation to study the efficiency of multiple policies.Based on simulation results,an improvement to the common lock-out policy is proposed.This new policy utilizes the rules of the lock-out policy but integrates an option that allows a group of vehicles to be given temporary priority in a certain direction of travel.Quantitative results are provided and,based on these,a systematic technique for ramp design that aims to optimize the efficiency of underground mine ramp traffic flow is described.展开更多
AIM: To evaluate the accuracy, efficiency, and reliability of a handheld infrared eccentric autorefractor(h ICA) with artificial intelligence(AI) by comparing its refraction measurements to those recorded using h ICA ...AIM: To evaluate the accuracy, efficiency, and reliability of a handheld infrared eccentric autorefractor(h ICA) with artificial intelligence(AI) by comparing its refraction measurements to those recorded using h ICA and a clinical table-mounted automatic refractor(TAR).METHODS: A cross-sectional study using three optometers, including h ICA with or without AI and TAR, for refractometry of adults(aged 19-49 years old) with no signs of ocular disease or trauma in the absence of cycloplegia. Right and left eye refraction data were recorded, including the spherical equivalent(SE), diopter of spherical power(DS), diopter of cylindrical power(DC) decomposed into vectors J0 and J45, and measurement times. To avoid analytical difficulties associated with the interdependence of observations between eyes from the same individual, the Generalized Estimation Equation was used to compare the SE, DS, J0 and J45 measurements, and the times thereof, among the different groups. The intraclass correlation coef f icient(ICC) and Spearman’s rank correlation coefficient were used to evaluate correlations among the measurements recorded by the three different instruments. Bland-Altman were used to analyze the precision of the equipment by the agreement. RESULTS: A total of 70 patients(140 eyes;mean age: 31.37 y;range: 19-49 y) were assessed using refractometry. In a brightly lit environment, there was no significant difference between the mean SE recorded using TAR and that recorded using h ICA with AI or without AI(both P>0.05). In an intense-light environment, h ICA equipped with AI showed a better detection rate than without AI. Light intensity had a greater effect on dioptric measurements recorded using h ICA without AI(P<0.001) than on those recorded using the one equipped with AI(P<0.05). Measurement times varied significantly between the different light intensities and instruments(P<0.05).CONCLUSION: For the normal human eyes, AI may improve the accuracy, efficiency, and reliability of measurements recorded using h ICA in various light environments.展开更多
Mercury sphygmomanometer (MSM) is reliable and widely used in clinics and hospitals. The principle of Korotkoff sounds method (KSM) applied in the MSM is also a gold standard to measure blood pressure. Many efforts ha...Mercury sphygmomanometer (MSM) is reliable and widely used in clinics and hospitals. The principle of Korotkoff sounds method (KSM) applied in the MSM is also a gold standard to measure blood pressure. Many efforts have been made attempting to replace MSM, which is criticized for being not healthy and safe. In this research, an electronic blood pressure monitor, named K-sounds electronic sphygmomanometer (KESM), was designed as a substitute to MSM. The three key elements of KSM were proposed for the first time. We used appropriate electronic components to build the KESM which can fulfill the functions related to the three key elements. The KESM, which was easy to operate and free of mercury, followed the same principle as MSM. The same principle guaranteed the comparable accuracy. We took equivalence test and the results showed that the designed KESM was as accurate as the calibrated standard MSM. The designed KESM passed the certifications of SFDA and is qualified in clinics or hospitals for diagnostic purposes.展开更多
The presented work will show the highest relevance of solving all the issues related to this problem and present the results of the analysis of the main expected potential problems,which may occur in the implementatio...The presented work will show the highest relevance of solving all the issues related to this problem and present the results of the analysis of the main expected potential problems,which may occur in the implementation of the INDUSTRY-4.0 reform.It is proved that the pace and level of development of this reform will be determined to a large extent by the effectiveness of the individual nodes used and the entire mechatronic system.It has also been established that as a result of systematic miniaturization of the nodes of radio-electronic equipment and microelectronic equipment and microelectronic technology,the main problem of these reforms and the implementation of complex technological processes is instrumental and technological support,especially with cutting micro-tools and equipment.Therefore,on the example of these investigations,methods for improving their performance are shown.展开更多
Objective To discuss the scheme and implementation of workstation configuration for medical imaging information systems suitable to the practical situation in China. Methods The workstations were logically divided i...Objective To discuss the scheme and implementation of workstation configuration for medical imaging information systems suitable to the practical situation in China. Methods The workstations were logically divided into picture archiving and communication system (PACS) workstations and radiology information system (RIS) workstations. The former applied to three kinds of diagnostic practice: the small matrix images, large matrix images and high resolution grayscale display applications. The latter consisted many different models defined by the usage and function processes.Results A dual-screen configuration for image interpretation workstations integrated the image-viewing and reporting procedures physically. Small matrix images as CT or MR were operated on 17 inch (1 inch=2.54 cm) color monitors, while conventional X-ray interpretation was performed on 21 inch color monitors or portrait format grayscale 2 k by 2.5 k monitors. All other RIS workstations not involved in imaging process were set up with a common PC configuration. Conclusion Workstation schemes for medical imaging information systems should satisfy the basic requirements of medical imaging and investment budget.展开更多
Background Single incision laparoscopic colectomy has been performed in recent years, and has been shown to be feasible and safe. This study was to assess the feasibility of single incision laparoscopic right hemicole...Background Single incision laparoscopic colectomy has been performed in recent years, and has been shown to be feasible and safe. This study was to assess the feasibility of single incision laparoscopic right hemicolectomy and to compare the differences in different approaches. Methods This retrospective study included eighteen patients with carcinoma of caecum and ascending colon, undergoing single incision laparoscopic right hemicolectomy. This study also compared single incision laparoscopic right hemicolectomy using different approaches: (1) single incision multiport, (2) single access port and (3) glove port. Results There was no statistical difference in surgical outcomes. Concerning the surgeon's satisfaction toward three methods, overcrowding and durability were similar but the single incision multiport was associated with the highest gas-leak and the "glove" port was associated with poor durability. However, the method of single incision multiport has the lowest average cost of the special trocar or port in each operation. The operative time and blood loss of the operations in this study were comparable to previous publications. Conclusion There was no significant difference between different approaches of single incision laparoscopic right hemicolectomy for colonic cancer in right side colon.展开更多
Objective To determine a network solution to meet the network requirements of the heavy data flow, load balance, and potential network storms from expansion of picture archiving and communication system (PACS) appli...Objective To determine a network solution to meet the network requirements of the heavy data flow, load balance, and potential network storms from expansion of picture archiving and communication system (PACS) application.Methods Intel Netstructure 480T Giga Switch was used as the main switch and connected to each building by fiber channel at 1 Giga speed to archive 100 MB/s to each port. At the same time, the in-dependence of the original network construction was physically kept. The layer 3 and 4 switchers were used as load balance to reduce the heavy load of the network, and all the cabling for PACS used the super CAT5 along with the Intel NetStructure 1520 to prepare for potential network storms.Results An advanced intranet was set up to fully meet the high standard requirement of the PACS. The foundation for upgrading the whole network system to 1 Giga application was built to achieve sharing and transmission of images, information, and patient data within the hospital. The base was established for the standardized management of the hospital.Conclusion Good planning is the first step in setting up PACS, and the equipment forms the necessary platform to run PACS and all kinds of hospital information system (HIS). The networking construction is the foundation of e-hospital.展开更多
Objective To investigate the set-up and preliminary performance of a digital radiology conference system and its characteristics. Methods The imaging system included a dual-screen image-text workstation with a Matr...Objective To investigate the set-up and preliminary performance of a digital radiology conference system and its characteristics. Methods The imaging system included a dual-screen image-text workstation with a Matrox G450 demonstration dual-head card, two multimedia projectors, a large screen, and a line-pair and grey scale test card. Patient information on radiology information system (RIS) and images on picture archiving and communication system (PACS) were fetched with GE Radworks software based on Intranet and PACS. The fetching velocity and resolution and grey scale of the images were measured. Results Patient information in the form of texts and images were demonstrated successfully on two screens with Matrox G450 demonstration dual-head card and switched rapidly between text-image two-screen and image two-screen. The image fetching velocity was fast, the resolution was high, and the grey scale was good. Conclusion The digital conference radiology system is good, and should be popularized.展开更多
文摘Selecting the optimal one from similar schemes is a paramount work in equipment design.In consideration of similarity of schemes and repetition of characteristic indices,the theory of set pair analysis(SPA)is proposed,and then an optimal selection model is established.In order to improve the accuracy and flexibility,the model is modified by the contribution degree.At last,this model has been validated by an example,and the result demonstrates the method is feasible and valuable for practical usage.
文摘With the development of electronic equipment to high accuracy, high density, high frequency, and atrocious ser- vice environment, the functional surface in this type of equipment has increasingly serious problems,
基金founded by the Earthquake Science and Technology Spark Plan of China(XH12063)
文摘Characteristic period is an important parameter of the seismic design response spectrum. There is important theoretical significance and engineering application value to the study of the characteristic period of seismic design response spectrum of ultra high voltage (UHV) electrical equipment. In this paper, 1448 horizontal earthquake records within the world scope including the United States and Japan for Site Class m were analyzed. Results show that both magnitude and epicentral distance have great influence on the characteristic period. About 80 % of characteristic periods of strong earthquake records are about 0. 9s. Statistical analysis was conducted on the seismic hazard assessment results of 312 projects of China in recent years, and it is found that about 70 % of characteristic periods are about 0. 9s. Combined with the related code comparison and analysis, it is suggested that the characteristic period of the seismic design response spectrmn of UHV electrical equipment should select 0. 9s in order to effectively guarantee the seismic safety of UHV electrical equipment.
文摘Since the excessive capacity in steelmaking and continuous casting at present,and the limited development margin of CC technology and equipment in scale,the further development must be made in a profound and detailized way.This paper enumerates the items of CC technology and equipment,which need to be detailized from several aspects such as roll arrangement design,equipment design and production operation,and it points out that detailization is the future direction of CC technology and equipment.The items in roll arrangement design include eliminating periodic meniscus fluctuation by adjusting space between rolls reasonably;taking special measures to avoid dangerous regions of casting speed,in order to reduce the center porosity and centerline crack of slab;optimizing the major radius and the length of outer arc of caster before straightening point to avoid dangerous region of casting speed.The items in equipment design include choosing a suitable structure of support and guiding roll according to the concrete conditions of caster;according to bulging shape of slab,thinking more about restriction of shell to bulging force, discussing the force on rollers,optimizing split roll to support slab;safety factor should be considered together with calculation method of the bearing nominal static load.The items in aspects of continuous casting operation include the delicacy division and the function-positioning of operation modes for CC machine due to the consideration of dynamic soft reduction;monitoring and controlling system of CC machine must be further detailized to improve the stability of production operation and slab quality.In addition to the three aspects mentioned above,this article points out many other items also,such as homogenization of secondary cooling of slab,quality control of surface and internal of slab,and so on.This article emphasizes,some key technologies need to be researched also,and all these researches will never stop.
基金funded by the Natural Science and Engineering Research Council of Canada (NSERC) under project CRDPJ 44SBO4-12funding provided by Barrick Gold Corporation and Peck Tech Consulting Ltd
文摘Traffic management in underground mines,especially on production ramps,is a difficult problem to optimize and control.Most operations use one of a few common policies;e.g.,the so-called ‘‘lock-out" and‘‘loaded-vehicle-priority" policies.The work presented in this paper uses discrete-event simulation to study the efficiency of multiple policies.Based on simulation results,an improvement to the common lock-out policy is proposed.This new policy utilizes the rules of the lock-out policy but integrates an option that allows a group of vehicles to be given temporary priority in a certain direction of travel.Quantitative results are provided and,based on these,a systematic technique for ramp design that aims to optimize the efficiency of underground mine ramp traffic flow is described.
基金Supported by the Science and Technology Commission of Shanghai(No.17DZ2260100)。
文摘AIM: To evaluate the accuracy, efficiency, and reliability of a handheld infrared eccentric autorefractor(h ICA) with artificial intelligence(AI) by comparing its refraction measurements to those recorded using h ICA and a clinical table-mounted automatic refractor(TAR).METHODS: A cross-sectional study using three optometers, including h ICA with or without AI and TAR, for refractometry of adults(aged 19-49 years old) with no signs of ocular disease or trauma in the absence of cycloplegia. Right and left eye refraction data were recorded, including the spherical equivalent(SE), diopter of spherical power(DS), diopter of cylindrical power(DC) decomposed into vectors J0 and J45, and measurement times. To avoid analytical difficulties associated with the interdependence of observations between eyes from the same individual, the Generalized Estimation Equation was used to compare the SE, DS, J0 and J45 measurements, and the times thereof, among the different groups. The intraclass correlation coef f icient(ICC) and Spearman’s rank correlation coefficient were used to evaluate correlations among the measurements recorded by the three different instruments. Bland-Altman were used to analyze the precision of the equipment by the agreement. RESULTS: A total of 70 patients(140 eyes;mean age: 31.37 y;range: 19-49 y) were assessed using refractometry. In a brightly lit environment, there was no significant difference between the mean SE recorded using TAR and that recorded using h ICA with AI or without AI(both P>0.05). In an intense-light environment, h ICA equipped with AI showed a better detection rate than without AI. Light intensity had a greater effect on dioptric measurements recorded using h ICA without AI(P<0.001) than on those recorded using the one equipped with AI(P<0.05). Measurement times varied significantly between the different light intensities and instruments(P<0.05).CONCLUSION: For the normal human eyes, AI may improve the accuracy, efficiency, and reliability of measurements recorded using h ICA in various light environments.
基金Supported by the Innovation Fund Project from Ministry of Science and Technology of China (08C26214401239)
文摘Mercury sphygmomanometer (MSM) is reliable and widely used in clinics and hospitals. The principle of Korotkoff sounds method (KSM) applied in the MSM is also a gold standard to measure blood pressure. Many efforts have been made attempting to replace MSM, which is criticized for being not healthy and safe. In this research, an electronic blood pressure monitor, named K-sounds electronic sphygmomanometer (KESM), was designed as a substitute to MSM. The three key elements of KSM were proposed for the first time. We used appropriate electronic components to build the KESM which can fulfill the functions related to the three key elements. The KESM, which was easy to operate and free of mercury, followed the same principle as MSM. The same principle guaranteed the comparable accuracy. We took equivalence test and the results showed that the designed KESM was as accurate as the calibrated standard MSM. The designed KESM passed the certifications of SFDA and is qualified in clinics or hospitals for diagnostic purposes.
基金This work was supported by Shota Rustaveli National Science Foundation(SRNSF)[PHDF-19-2224,Improving the efficiency of mechatronic systems in order to ensure the reform of“Industry-4.0”].
文摘The presented work will show the highest relevance of solving all the issues related to this problem and present the results of the analysis of the main expected potential problems,which may occur in the implementation of the INDUSTRY-4.0 reform.It is proved that the pace and level of development of this reform will be determined to a large extent by the effectiveness of the individual nodes used and the entire mechatronic system.It has also been established that as a result of systematic miniaturization of the nodes of radio-electronic equipment and microelectronic equipment and microelectronic technology,the main problem of these reforms and the implementation of complex technological processes is instrumental and technological support,especially with cutting micro-tools and equipment.Therefore,on the example of these investigations,methods for improving their performance are shown.
文摘Objective To discuss the scheme and implementation of workstation configuration for medical imaging information systems suitable to the practical situation in China. Methods The workstations were logically divided into picture archiving and communication system (PACS) workstations and radiology information system (RIS) workstations. The former applied to three kinds of diagnostic practice: the small matrix images, large matrix images and high resolution grayscale display applications. The latter consisted many different models defined by the usage and function processes.Results A dual-screen configuration for image interpretation workstations integrated the image-viewing and reporting procedures physically. Small matrix images as CT or MR were operated on 17 inch (1 inch=2.54 cm) color monitors, while conventional X-ray interpretation was performed on 21 inch color monitors or portrait format grayscale 2 k by 2.5 k monitors. All other RIS workstations not involved in imaging process were set up with a common PC configuration. Conclusion Workstation schemes for medical imaging information systems should satisfy the basic requirements of medical imaging and investment budget.
文摘Background Single incision laparoscopic colectomy has been performed in recent years, and has been shown to be feasible and safe. This study was to assess the feasibility of single incision laparoscopic right hemicolectomy and to compare the differences in different approaches. Methods This retrospective study included eighteen patients with carcinoma of caecum and ascending colon, undergoing single incision laparoscopic right hemicolectomy. This study also compared single incision laparoscopic right hemicolectomy using different approaches: (1) single incision multiport, (2) single access port and (3) glove port. Results There was no statistical difference in surgical outcomes. Concerning the surgeon's satisfaction toward three methods, overcrowding and durability were similar but the single incision multiport was associated with the highest gas-leak and the "glove" port was associated with poor durability. However, the method of single incision multiport has the lowest average cost of the special trocar or port in each operation. The operative time and blood loss of the operations in this study were comparable to previous publications. Conclusion There was no significant difference between different approaches of single incision laparoscopic right hemicolectomy for colonic cancer in right side colon.
文摘Objective To determine a network solution to meet the network requirements of the heavy data flow, load balance, and potential network storms from expansion of picture archiving and communication system (PACS) application.Methods Intel Netstructure 480T Giga Switch was used as the main switch and connected to each building by fiber channel at 1 Giga speed to archive 100 MB/s to each port. At the same time, the in-dependence of the original network construction was physically kept. The layer 3 and 4 switchers were used as load balance to reduce the heavy load of the network, and all the cabling for PACS used the super CAT5 along with the Intel NetStructure 1520 to prepare for potential network storms.Results An advanced intranet was set up to fully meet the high standard requirement of the PACS. The foundation for upgrading the whole network system to 1 Giga application was built to achieve sharing and transmission of images, information, and patient data within the hospital. The base was established for the standardized management of the hospital.Conclusion Good planning is the first step in setting up PACS, and the equipment forms the necessary platform to run PACS and all kinds of hospital information system (HIS). The networking construction is the foundation of e-hospital.
文摘Objective To investigate the set-up and preliminary performance of a digital radiology conference system and its characteristics. Methods The imaging system included a dual-screen image-text workstation with a Matrox G450 demonstration dual-head card, two multimedia projectors, a large screen, and a line-pair and grey scale test card. Patient information on radiology information system (RIS) and images on picture archiving and communication system (PACS) were fetched with GE Radworks software based on Intranet and PACS. The fetching velocity and resolution and grey scale of the images were measured. Results Patient information in the form of texts and images were demonstrated successfully on two screens with Matrox G450 demonstration dual-head card and switched rapidly between text-image two-screen and image two-screen. The image fetching velocity was fast, the resolution was high, and the grey scale was good. Conclusion The digital conference radiology system is good, and should be popularized.