The accuracy of landslide susceptibility prediction(LSP)mainly depends on the precision of the landslide spatial position.However,the spatial position error of landslide survey is inevitable,resulting in considerable ...The accuracy of landslide susceptibility prediction(LSP)mainly depends on the precision of the landslide spatial position.However,the spatial position error of landslide survey is inevitable,resulting in considerable uncertainties in LSP modeling.To overcome this drawback,this study explores the influence of positional errors of landslide spatial position on LSP uncertainties,and then innovatively proposes a semi-supervised machine learning model to reduce the landslide spatial position error.This paper collected 16 environmental factors and 337 landslides with accurate spatial positions taking Shangyou County of China as an example.The 30e110 m error-based multilayer perceptron(MLP)and random forest(RF)models for LSP are established by randomly offsetting the original landslide by 30,50,70,90 and 110 m.The LSP uncertainties are analyzed by the LSP accuracy and distribution characteristics.Finally,a semi-supervised model is proposed to relieve the LSP uncertainties.Results show that:(1)The LSP accuracies of error-based RF/MLP models decrease with the increase of landslide position errors,and are lower than those of original data-based models;(2)70 m error-based models can still reflect the overall distribution characteristics of landslide susceptibility indices,thus original landslides with certain position errors are acceptable for LSP;(3)Semi-supervised machine learning model can efficiently reduce the landslide position errors and thus improve the LSP accuracies.展开更多
In this paper,an antenna array composed of circular array and orthogonal linear array is proposed by using the design of long and short baseline“orthogonal linear array”and the circular array ambiguity resolution de...In this paper,an antenna array composed of circular array and orthogonal linear array is proposed by using the design of long and short baseline“orthogonal linear array”and the circular array ambiguity resolution design of multi-group baseline clustering.The effectiveness of the antenna array in this paper is verified by sufficient simulation and experiment.After the system deviation correction work,it is found that in the L/S/C/X frequency bands,the ambiguity resolution probability is high,and the phase difference system error between each channel is basically the same.The angle measurement error is less than 0.5°,and the positioning error is less than 2.5 km.Notably,as the center frequency increases,calibration consistency improves,and the calibration frequency points become applicable over a wider frequency range.At a center frequency of 11.5 GHz,the calibration frequency point bandwidth extends to 1200 MHz.This combined antenna array deployment holds significant promise for a wide range of applications in contemporary wireless communication systems.展开更多
Magnetic field gradient tensor measurement is an important technique to obtain position information of magnetic objects. When using magnetic field sensors to measure magnetic field gradient as the coefficients of tens...Magnetic field gradient tensor measurement is an important technique to obtain position information of magnetic objects. When using magnetic field sensors to measure magnetic field gradient as the coefficients of tensor, field differentiation is generally approximated by field difference. As a result, magnetic objects positioning by magnetic field gradient tensor measurement always involves an inherent error caused by sensor sizes, leading to a reduction in detectable distance and detectable angle. In this paper, the inherent positioning error caused by magnetic field gradient tensor measurement is calculated and corrected by iterations based on the systematic position error distribution patterns. The results show that, the detectable distance range and the angle range of an ac magnetic object(2.44 Am^2@1 kHz) can be increased from(0.45 m, 0.75 m),(0?, 25?) to(0.30 m, 0.80 m),(0?,80?), respectively.展开更多
Beam shaping is required for semiconductor lasers to achieve high optical fiber coupling efficiency in many applications.But the positioning errors on optics may reduce beam shaping effects,and then lead to low optica...Beam shaping is required for semiconductor lasers to achieve high optical fiber coupling efficiency in many applications.But the positioning errors on optics may reduce beam shaping effects,and then lead to low optical fiber coupling efficiency.In this work,the positioning errors models for the single emitter laser diode beam shaping system are established.Moreover,the relationships between the errors and the beam shaping effect of each shapers are analysed.Subsequently,the relationship between the errors and the optical fiber coupling efficiency is analysed.The result shows that position errors in the Z axis direction on the fast axis collimator have the greatest influence on the shaping effect,followed by the position errors in the Z axis direction on the converging lens,which should be strictly suppressed in actual operation.Besides,the position errors have a significant influence on the optical fiber coupling efficiency and need to be avoided.展开更多
The uncertainty of observers' positions can lead to significantly degrading in source localization accuracy. This pa-per proposes a method of using self-location for calibrating the positions of observer stations in ...The uncertainty of observers' positions can lead to significantly degrading in source localization accuracy. This pa-per proposes a method of using self-location for calibrating the positions of observer stations in source localization to reduce the errors of the observer positions and improve the accuracy of the source localization. The relative distance measurements of the two coordinative observers are used for the linear minimum mean square error (LMMSE) estimator. The results of computer si-mulations prove the feasibility and effectiveness of the proposed method. With the general estimation errors of observers' positions, the MSE of the source localization with self-location calibration, which is significantly lower than that without self-location calibra-tion, is approximating to the Cramer-Rao lower bound (CRLB).展开更多
The influence of laser beam divergence angle on the positioning accuracy of scanning airborne light detection and ranging (LIDAR) is analyzed and simulated. Based on the data process and positioning principle of air...The influence of laser beam divergence angle on the positioning accuracy of scanning airborne light detection and ranging (LIDAR) is analyzed and simulated. Based on the data process and positioning principle of airborne LIDAR, the errors from pulse broadening induced by laser beam di vergence angle are modeled and qualitatively analyzed for different terrain surfaces. Simulated results of positioning errors and suggestions to reduce them are given for the flat surface, the downhill of slope surface, and the uphill surface.展开更多
Objective To explore the differences in three different registration methods of cone beam computed tomography(CBCT)-guided down-regulated intense radiation therapy for lung cancer as well as the effects of tumor locat...Objective To explore the differences in three different registration methods of cone beam computed tomography(CBCT)-guided down-regulated intense radiation therapy for lung cancer as well as the effects of tumor location,treatment mode,and tumor size on registration.Methods This retrospective analysis included 80 lung cancer patients undergoing radiotherapy in our hospital from November 2017 to October 2019 and compared automatic bone registration,automatic grayscale(t+r)registration,and automatic grayscale(t)positioning error on the X-,Y-,and Z-axes under three types of registration methods.The patients were also grouped according to tumor position,treatment mode,and tumor size to compare positioning errors.Results On the X-,Y-,and Z-axes,automatic grayscale(t+r)and automatic grayscale(t)registration showed a better trend.Analysis of the different treatment modes showed differences in the three registration methods;however,these were not statistically significant.Analysis according to tumor sizes showed significant differences between the three registration methods(P<0.05).Analysis according to tumor positions showed differences in the X-and Y-axes that were not significant(P>0.05),while the autopsy registration in the Z-axis showed the largest difference in the mediastinal and hilar lymph nodes(P<0.05).Conclusion The treatment mode was not the main factor affecting registration error in lung cancer.Three registration methods are available for tumors in the upper and lower lungs measuring<3 cm;among these,automatic gray registration is recommended,while any gray registration method is recommended for tumors located in the mediastinal hilar site measuring<3 cm and in the upper and lower lungs≥3 cm.展开更多
Clearances at joints cause an uncertainty in the actual posture of the end-effector of any mechanism. This uncertainty relays on the clearance dimension and the way these clearances are taken up by the mechanism under...Clearances at joints cause an uncertainty in the actual posture of the end-effector of any mechanism. This uncertainty relays on the clearance dimension and the way these clearances are taken up by the mechanism under the load and the inertial effects at every instant. As a matter of fact, the actual measure of the pose error is often replaced by an uncertainty measure. However, a side effect of the existence of clearances is that they can cause sudden changes in the posture of the mechanism as a motion is performed. Such discontinuities in the position produce task defects and impacts. In this work a tool to determine the pose error due to clearances is presented together with a discontinuity analysis. In addition, effects of mass distribution and inertial effects on such discontinuities are expounded, taking a 3-PRS robot as example.展开更多
Micro milling has many advantages in fabricating three-dimensional(3D) structure in micrometer scale. The micro milling machine tool with high positioning accuracy is of great importance for getting micro structure wi...Micro milling has many advantages in fabricating three-dimensional(3D) structure in micrometer scale. The micro milling machine tool with high positioning accuracy is of great importance for getting micro structure with high profile precision and good surface quality. Meanwhile, the method of position error compensation is a good way to improve the accuracy of the micro milling machine tools. In this paper,a software method is adopted to compensate the positioning error and improve the positioning accuracy. According to error cancellation theory,the compensation values are generated and compensation tables are built to adjust the positioning error in the NC system based on Industrial Motion and Automation Control( IMAC). The positioning accuracy of linear motor is ± 0. 3 μm without backlash after compensation. In order to verify the effectiveness of compensation on the machining performance,concave spherical surfaces are processed on the micro milling machine tool. The experimental results show that the profile radius error of the spherical surface machined with compensation decreases more than 60%.展开更多
This paper presents a method of rapid machine tool error modeling, separation, and compensation using grating ruler. A robust modeling procedure for geometric errors is developed and a fast data processing algorithm i...This paper presents a method of rapid machine tool error modeling, separation, and compensation using grating ruler. A robust modeling procedure for geometric errors is developed and a fast data processing algorithm is designed by using the error separation technique. After compensation with the new method, the maximum position error of the experiment workbench can be reduced from 400 μm to 15 μm. The experimental results show the effectiveness and accuracy of this method.展开更多
To determine the distribution of positional error of a line segment, Monte Carlo approach is applied to simulate the probability density function of a line segment with the assumption that the error of endpoints in a ...To determine the distribution of positional error of a line segment, Monte Carlo approach is applied to simulate the probability density function of a line segment with the assumption that the error of endpoints in a line segment follows a two-dimensional normal distribution. For such purpose, a stochastic generator used for uncertain endpoints with the two-dimensional normal distribution is presented. This forms the basis of the generation of random line segment for the simulation of the error model of a whole line segment. The error models cover the cases where two endpoints are either independent or dependent to each other, also including a special case that the distance between two random endpoints in a line segment is close enough.展开更多
Exposure to stress negatively affects error processing,but the impact of stress on error awareness remains to be determined.In the present study,we examined the temporal dynamics of error awareness and post-error adju...Exposure to stress negatively affects error processing,but the impact of stress on error awareness remains to be determined.In the present study,we examined the temporal dynamics of error awareness and post-error adjustment following acute stress.Forty-nine healthy men were randomly assigned to the control(n=26)or stress group(n=23).After stress induction,participants completed the error awareness task,and their brain activity was assessed by electroencephalography.Compared to the control group,the stress group demonstrated lower error awareness accuracy and smaller Pe(error positivity)and ΔPe amplitudes following aware error responses,which indicated impairment of error awareness following stress.Furthermore,the stress group had lower accuracy in post-aware error responses than in post-unaware error responses and the control group,which indicated poor post-error adjustment following stress.Our results showed a stress effect on sequential stages of error processing.Stress induces impaired error identification,which further generates maladaptive post-error performance.展开更多
Based on an analysis of the relative shaft-to-hole position and attiude errors, as well as of the mechanics and Kinematics in the process of automatic assembly of industrial robots, the paper studies the principle of ...Based on an analysis of the relative shaft-to-hole position and attiude errors, as well as of the mechanics and Kinematics in the process of automatic assembly of industrial robots, the paper studies the principle of construction of dynamic wrists. Type I-3 and Ⅱ-6 dynamic compliant wrists have been designed and made. Prblems in the production of compliant elements and the connection between compliant elements and wrists were also solved. A study on the results of tests of the function of two kinds of dynamic compliant wrists shows that the dynamic compliant wrist's compliancy function can be improved by adding metallic materials having higher longitudinal and transverse rigidity into the softer elstomer. And the design Principle is proved to be feasible and practicable. It can be expected that the use of dynamic compliant wrist will greatly lower the technical requirements of the shaft-hole assembly and the requirements in the resetting accuracy.展开更多
Research of thermal characteristics has been a key issue in the development of high-speed feed system. Most of the work carried out thus far is based on the principle of directly mapping the thermal error against the ...Research of thermal characteristics has been a key issue in the development of high-speed feed system. Most of the work carried out thus far is based on the principle of directly mapping the thermal error against the temperature of critical machine elements irrespective of the operating conditions. But recent researches show that different sets of operating parameters generated significantly different error values even though the temperature of the machine elements generated was similar. As such, it is important to develop a generic thermal error model which is capable of evaluating the positioning error induced by different operating parameters. This paper ultimately aims at the development of a comprehensive prediction model that can predict the thermal characteristics under different operating conditions (feeding speed, load and preload of ballscrew) in a feed system. A novel wavelet neural network based on feedback linearization autoregressive moving averaging (NARMA-L2) model is introduced to predict the temperature rise of sensitive points and thermal positioning errors considering the different operating conditions as the model inputs. Particle swarm optimization(PSO) algorithm is brought in as the training method. According to ISO230-2 Positioning Accuracy Measurement and ISO230-3 Thermal Effect Evaluation standards, experiments under different operating conditions were carried out on a self-made quasi high-speed feed system experimental bench HUST-FS-001 by using Pt100 as temperature sensor, and the positioning errors were measured by Heidenhain linear grating scale. The experiment results show that the recommended method can be used to predict temperature rise of sensitive points and thermal positioning errors with good accuracy. The work described in this paper lays a solid foundation of thermal error prediction and compensation in a feed system based on varying operating conditions and machine tool characteristics.展开更多
Lung cancer is one of the most common malignant tumors. It has the highest incidence and mortality rate of all cancers worldwide. Late diagnosis of nonsmall cell lung cancer(NSCLC) is very common in clinical practice,...Lung cancer is one of the most common malignant tumors. It has the highest incidence and mortality rate of all cancers worldwide. Late diagnosis of nonsmall cell lung cancer(NSCLC) is very common in clinical practice, and most patients miss the chance for radical surgery. Thus, radiotherapy plays an indispensable role in the treatment of NSCLC. Radiotherapy technology has evolved from the classic two-dimensional approach to three-dimensional conformal and intensity-modulated radiotherapy. However, how to ensure delivery of an accurate dose to the tumor while minimizing the irradiation of normal tissues remains a huge challenge for radiation oncologists, especially due to the positioning error between fractions and the autonomous movement of organs. In recent years, image-guided radiotherapy(IGRT) has greatly increased the accuracy of tumor irradiation while reducing the irradiation dose delivered to healthy tissues and organs. This paper presents a brief review of the definition of IGRT and the various technologies and applications of IGRT. IGRT can help ensure accurate dosing of the target area and reduce radiation damage to the surrounding normal tissue. IGRT may increase the local control rate of tumors and reduce the incidence of radio-therapeutic complications.展开更多
Automatic navigation of an articulated drum roller, which is an articulated steering type vehicle widely used in the construction industry, is highly expected for operation cost reduction and improvement of work effi-...Automatic navigation of an articulated drum roller, which is an articulated steering type vehicle widely used in the construction industry, is highly expected for operation cost reduction and improvement of work effi- ciency. In order to achieve the path following control, considering that its steering system is articulated steering and two frames are articulated by an active revolute joint, a kinematic model and an error dynamic state-space equation of an articulated drum roller are proposed. Besides, a state- feedback control law based on Lyapunov stability theory is also designed, which can be proved to achieve the purpose of control by the analysis of stability. What's more, to evaluate the performance of the proposed method, simu- lation under the MATLAB/Simulink and experiments using positioning algorithm and errors correction at the uneven construction site are performed, with initial dis- placement error (-1.5 m), heading error (-0.11 tad) and steering angle (-0.19 rad). Finally, simulation and exper- imental results show that the errors and steering angle can decrease gradually, and converge to zero with time. Meanwhile, the control input is not saturated. An articu- lated drum roller can lock into a desired path with the proposed method in uneven fields.展开更多
The measurement of the rolling angle of the projectile is one of the key technologies for the terminal correction projectile.To improve the resolution accuracy of the rolling angle in the laser seeker weapon system, t...The measurement of the rolling angle of the projectile is one of the key technologies for the terminal correction projectile.To improve the resolution accuracy of the rolling angle in the laser seeker weapon system, the imaging model of the detector, calculation model of the position and the signal-to-noise ratio(SNR) model of the circuit are built to derive both the correlation between the resolution error of the rolling angle and the spot position, and the relation between the position resolution error and the SNR. Then the influence of each parameter on the SNR is analyzed at large,and the parameters of the circuit are determined. Meanwhile, the SNR and noise voltage of the circuit are calculated according to the SNR model and the decay model of the laser energy. Finally,the actual photoelectric detection circuit is built, whose SNR is measured to be up to 53 d B. It can fully meet the requirement of0.5° for the resolution error of the rolling angle, thereby realizing the analysis of critical technology for photoelectric detection of laser seeker signals.展开更多
Five-hundred-meter Aperture Spherical radio Telescope(FAST)is the world’s largest single dish radio telescope,which is located in Guizhou Province,in southwest China.The FAST feed cabin is supported and positioned by...Five-hundred-meter Aperture Spherical radio Telescope(FAST)is the world’s largest single dish radio telescope,which is located in Guizhou Province,in southwest China.The FAST feed cabin is supported and positioned by six steel cables.The deviation of the feed position and orientation would lead to loss in the telescope efficiency.In this paper,a series of electromagnetic(EM)simulations of the FAST facility with varying feed positions and orientation offsets was performed.The maximum gain of FAST is about 82.3 dBi and the sibelobe is–32 dB with respect to the main beam at 3 GHz.The simulation results have demonstrated that the telescope efficiency loss is more sensitive to the lateral feed deviation compared with the axial deviation.The telescope efficiency would decrease by 8.2%due to the FAST feed position deviation of 10 mm rms when the observing frequency is 3 GHz.The FAST feed deviation basically has no effect on the sidelobes and cross polarization characteristic according to the simulations.展开更多
Monitoring the performance of any structure requires real-time measurements of the change of position of critical points. Different techniques can be used for this purpose, each one offering advantages and disadvantag...Monitoring the performance of any structure requires real-time measurements of the change of position of critical points. Different techniques can be used for this purpose, each one offering advantages and disadvantages. The technique based on satellite positioning systems (GPS, GLONASS and the future GALILEO) seems to be very promising at least for long period structures. The GPS in particular provides sampling rates that are able to track dynamic displacements with high accuracy. Its service ability is independent of atmospheric conditions, temperature variations and visibility of the monitored object. This paper investigates the reliability and accuracy of the measurements of dual frequency GPS receivers. A linear electromagnetic motor moves an object along a given direction. The changes of position are compared witb their estimates as recorded by a GPS receiver, whose antenna is located on the reference object. The comparison is based on sufficiently long records.展开更多
This paper proposes a new approach to assess the positional accuracy of maps generated by overlaying multi_scale spatial data layers with different levels of positional accuracy.The existing techniques for assessing t...This paper proposes a new approach to assess the positional accuracy of maps generated by overlaying multi_scale spatial data layers with different levels of positional accuracy.The existing techniques for assessing the positional accuracy of point,line and polygon features is first examined.Then a taxonomy of graphic features on the derived maps is developed by analyzing the specific processes of overlay operations.Finally,a detailed description of the new approach is provided and the implementation of this new method in practical applications is described.展开更多
基金the National Natural Science Foundation of China(Grant Nos.42377164 and 52079062)the Interdisciplinary Innovation Fund of Natural Science,Nanchang University(Grant No.9167-28220007-YB2107).
文摘The accuracy of landslide susceptibility prediction(LSP)mainly depends on the precision of the landslide spatial position.However,the spatial position error of landslide survey is inevitable,resulting in considerable uncertainties in LSP modeling.To overcome this drawback,this study explores the influence of positional errors of landslide spatial position on LSP uncertainties,and then innovatively proposes a semi-supervised machine learning model to reduce the landslide spatial position error.This paper collected 16 environmental factors and 337 landslides with accurate spatial positions taking Shangyou County of China as an example.The 30e110 m error-based multilayer perceptron(MLP)and random forest(RF)models for LSP are established by randomly offsetting the original landslide by 30,50,70,90 and 110 m.The LSP uncertainties are analyzed by the LSP accuracy and distribution characteristics.Finally,a semi-supervised model is proposed to relieve the LSP uncertainties.Results show that:(1)The LSP accuracies of error-based RF/MLP models decrease with the increase of landslide position errors,and are lower than those of original data-based models;(2)70 m error-based models can still reflect the overall distribution characteristics of landslide susceptibility indices,thus original landslides with certain position errors are acceptable for LSP;(3)Semi-supervised machine learning model can efficiently reduce the landslide position errors and thus improve the LSP accuracies.
文摘In this paper,an antenna array composed of circular array and orthogonal linear array is proposed by using the design of long and short baseline“orthogonal linear array”and the circular array ambiguity resolution design of multi-group baseline clustering.The effectiveness of the antenna array in this paper is verified by sufficient simulation and experiment.After the system deviation correction work,it is found that in the L/S/C/X frequency bands,the ambiguity resolution probability is high,and the phase difference system error between each channel is basically the same.The angle measurement error is less than 0.5°,and the positioning error is less than 2.5 km.Notably,as the center frequency increases,calibration consistency improves,and the calibration frequency points become applicable over a wider frequency range.At a center frequency of 11.5 GHz,the calibration frequency point bandwidth extends to 1200 MHz.This combined antenna array deployment holds significant promise for a wide range of applications in contemporary wireless communication systems.
基金supported by the National Natural Science Foundation of China(61473023)
文摘Magnetic field gradient tensor measurement is an important technique to obtain position information of magnetic objects. When using magnetic field sensors to measure magnetic field gradient as the coefficients of tensor, field differentiation is generally approximated by field difference. As a result, magnetic objects positioning by magnetic field gradient tensor measurement always involves an inherent error caused by sensor sizes, leading to a reduction in detectable distance and detectable angle. In this paper, the inherent positioning error caused by magnetic field gradient tensor measurement is calculated and corrected by iterations based on the systematic position error distribution patterns. The results show that, the detectable distance range and the angle range of an ac magnetic object(2.44 Am^2@1 kHz) can be increased from(0.45 m, 0.75 m),(0?, 25?) to(0.30 m, 0.80 m),(0?,80?), respectively.
基金Project(51475479) supported by the National Natural Science Foundation of ChinaProject(2017YFB1104800) supported by the National Key Research and Development Program of China+2 种基金Project(2016GK2098) supported by the Key Research and Development Program of Hunan Province,ChinaProject(ZZYJKT2017-07) supported by the State Key Laboratory of High Performance Complex Manufacturing,Central South University,ChinaProject(JMTZ201804) supported by the Key Laboratory for Precision&Non-traditional Machining of Ministry of Education,Dalian University of Technology,China
文摘Beam shaping is required for semiconductor lasers to achieve high optical fiber coupling efficiency in many applications.But the positioning errors on optics may reduce beam shaping effects,and then lead to low optical fiber coupling efficiency.In this work,the positioning errors models for the single emitter laser diode beam shaping system are established.Moreover,the relationships between the errors and the beam shaping effect of each shapers are analysed.Subsequently,the relationship between the errors and the optical fiber coupling efficiency is analysed.The result shows that position errors in the Z axis direction on the fast axis collimator have the greatest influence on the shaping effect,followed by the position errors in the Z axis direction on the converging lens,which should be strictly suppressed in actual operation.Besides,the position errors have a significant influence on the optical fiber coupling efficiency and need to be avoided.
基金supported by the Fundamental Research Funds for the Central Universities(ZYGX2009J016)
文摘The uncertainty of observers' positions can lead to significantly degrading in source localization accuracy. This pa-per proposes a method of using self-location for calibrating the positions of observer stations in source localization to reduce the errors of the observer positions and improve the accuracy of the source localization. The relative distance measurements of the two coordinative observers are used for the linear minimum mean square error (LMMSE) estimator. The results of computer si-mulations prove the feasibility and effectiveness of the proposed method. With the general estimation errors of observers' positions, the MSE of the source localization with self-location calibration, which is significantly lower than that without self-location calibra-tion, is approximating to the Cramer-Rao lower bound (CRLB).
基金Supported by the National Basic Research Program of China("973"Program)(2009CB72400401A)
文摘The influence of laser beam divergence angle on the positioning accuracy of scanning airborne light detection and ranging (LIDAR) is analyzed and simulated. Based on the data process and positioning principle of airborne LIDAR, the errors from pulse broadening induced by laser beam di vergence angle are modeled and qualitatively analyzed for different terrain surfaces. Simulated results of positioning errors and suggestions to reduce them are given for the flat surface, the downhill of slope surface, and the uphill surface.
基金Supported by grants from the Nanchong City School Cooperation Project(No.18SXHZ0542)Hubei Chen Xiaoping Science and Technology Development Foundation Project(No.CXPJJH11900002-037)Sichuan Medical Research Youth Innovation Project(No.Q18031).
文摘Objective To explore the differences in three different registration methods of cone beam computed tomography(CBCT)-guided down-regulated intense radiation therapy for lung cancer as well as the effects of tumor location,treatment mode,and tumor size on registration.Methods This retrospective analysis included 80 lung cancer patients undergoing radiotherapy in our hospital from November 2017 to October 2019 and compared automatic bone registration,automatic grayscale(t+r)registration,and automatic grayscale(t)positioning error on the X-,Y-,and Z-axes under three types of registration methods.The patients were also grouped according to tumor position,treatment mode,and tumor size to compare positioning errors.Results On the X-,Y-,and Z-axes,automatic grayscale(t+r)and automatic grayscale(t)registration showed a better trend.Analysis of the different treatment modes showed differences in the three registration methods;however,these were not statistically significant.Analysis according to tumor sizes showed significant differences between the three registration methods(P<0.05).Analysis according to tumor positions showed differences in the X-and Y-axes that were not significant(P>0.05),while the autopsy registration in the Z-axis showed the largest difference in the mediastinal and hilar lymph nodes(P<0.05).Conclusion The treatment mode was not the main factor affecting registration error in lung cancer.Three registration methods are available for tumors in the upper and lower lungs measuring<3 cm;among these,automatic gray registration is recommended,while any gray registration method is recommended for tumors located in the mediastinal hilar site measuring<3 cm and in the upper and lower lungs≥3 cm.
文摘Clearances at joints cause an uncertainty in the actual posture of the end-effector of any mechanism. This uncertainty relays on the clearance dimension and the way these clearances are taken up by the mechanism under the load and the inertial effects at every instant. As a matter of fact, the actual measure of the pose error is often replaced by an uncertainty measure. However, a side effect of the existence of clearances is that they can cause sudden changes in the posture of the mechanism as a motion is performed. Such discontinuities in the position produce task defects and impacts. In this work a tool to determine the pose error due to clearances is presented together with a discontinuity analysis. In addition, effects of mass distribution and inertial effects on such discontinuities are expounded, taking a 3-PRS robot as example.
基金Sponsored by the National Natural Science Foundation of China(Grant No.50935003)
文摘Micro milling has many advantages in fabricating three-dimensional(3D) structure in micrometer scale. The micro milling machine tool with high positioning accuracy is of great importance for getting micro structure with high profile precision and good surface quality. Meanwhile, the method of position error compensation is a good way to improve the accuracy of the micro milling machine tools. In this paper,a software method is adopted to compensate the positioning error and improve the positioning accuracy. According to error cancellation theory,the compensation values are generated and compensation tables are built to adjust the positioning error in the NC system based on Industrial Motion and Automation Control( IMAC). The positioning accuracy of linear motor is ± 0. 3 μm without backlash after compensation. In order to verify the effectiveness of compensation on the machining performance,concave spherical surfaces are processed on the micro milling machine tool. The experimental results show that the profile radius error of the spherical surface machined with compensation decreases more than 60%.
文摘This paper presents a method of rapid machine tool error modeling, separation, and compensation using grating ruler. A robust modeling procedure for geometric errors is developed and a fast data processing algorithm is designed by using the error separation technique. After compensation with the new method, the maximum position error of the experiment workbench can be reduced from 400 μm to 15 μm. The experimental results show the effectiveness and accuracy of this method.
基金Funded by the National Natural Science Foundation of China (N0. 40501053), the Open Research Fund Program of LIESMARS (No. WKL040304) and theOpen Research Fund Program of Key Laboratory of Geomatics and Digital Technology, Shandong Province (No. SD040201)
文摘To determine the distribution of positional error of a line segment, Monte Carlo approach is applied to simulate the probability density function of a line segment with the assumption that the error of endpoints in a line segment follows a two-dimensional normal distribution. For such purpose, a stochastic generator used for uncertain endpoints with the two-dimensional normal distribution is presented. This forms the basis of the generation of random line segment for the simulation of the error model of a whole line segment. The error models cover the cases where two endpoints are either independent or dependent to each other, also including a special case that the distance between two random endpoints in a line segment is close enough.
基金supported by grants from the National Natural Science Foundation of China(32200878 and 32260206)the Annual 2022 Joint Project of Basic Research in Local Universities(part)in Yunnan province(202101BA070001-156)+1 种基金the Annual 2021 Educational Science Planning Project of Yunnan Province(BFSJY006)the Kunming University Talent Introduction Research Project(YJW2213).
文摘Exposure to stress negatively affects error processing,but the impact of stress on error awareness remains to be determined.In the present study,we examined the temporal dynamics of error awareness and post-error adjustment following acute stress.Forty-nine healthy men were randomly assigned to the control(n=26)or stress group(n=23).After stress induction,participants completed the error awareness task,and their brain activity was assessed by electroencephalography.Compared to the control group,the stress group demonstrated lower error awareness accuracy and smaller Pe(error positivity)and ΔPe amplitudes following aware error responses,which indicated impairment of error awareness following stress.Furthermore,the stress group had lower accuracy in post-aware error responses than in post-unaware error responses and the control group,which indicated poor post-error adjustment following stress.Our results showed a stress effect on sequential stages of error processing.Stress induces impaired error identification,which further generates maladaptive post-error performance.
文摘Based on an analysis of the relative shaft-to-hole position and attiude errors, as well as of the mechanics and Kinematics in the process of automatic assembly of industrial robots, the paper studies the principle of construction of dynamic wrists. Type I-3 and Ⅱ-6 dynamic compliant wrists have been designed and made. Prblems in the production of compliant elements and the connection between compliant elements and wrists were also solved. A study on the results of tests of the function of two kinds of dynamic compliant wrists shows that the dynamic compliant wrist's compliancy function can be improved by adding metallic materials having higher longitudinal and transverse rigidity into the softer elstomer. And the design Principle is proved to be feasible and practicable. It can be expected that the use of dynamic compliant wrist will greatly lower the technical requirements of the shaft-hole assembly and the requirements in the resetting accuracy.
基金supported by National Key Basic Research Program of China(973Program,Grant No.2005CB724100,Grant No.2011CB706803)National Natural Science Foundation of China(Grant No.50675076,Grant No.50575087,Grant No.51075161)National Hi-tech Research and Development Program of China(863Program,Grant No.2008AA042802)
文摘Research of thermal characteristics has been a key issue in the development of high-speed feed system. Most of the work carried out thus far is based on the principle of directly mapping the thermal error against the temperature of critical machine elements irrespective of the operating conditions. But recent researches show that different sets of operating parameters generated significantly different error values even though the temperature of the machine elements generated was similar. As such, it is important to develop a generic thermal error model which is capable of evaluating the positioning error induced by different operating parameters. This paper ultimately aims at the development of a comprehensive prediction model that can predict the thermal characteristics under different operating conditions (feeding speed, load and preload of ballscrew) in a feed system. A novel wavelet neural network based on feedback linearization autoregressive moving averaging (NARMA-L2) model is introduced to predict the temperature rise of sensitive points and thermal positioning errors considering the different operating conditions as the model inputs. Particle swarm optimization(PSO) algorithm is brought in as the training method. According to ISO230-2 Positioning Accuracy Measurement and ISO230-3 Thermal Effect Evaluation standards, experiments under different operating conditions were carried out on a self-made quasi high-speed feed system experimental bench HUST-FS-001 by using Pt100 as temperature sensor, and the positioning errors were measured by Heidenhain linear grating scale. The experiment results show that the recommended method can be used to predict temperature rise of sensitive points and thermal positioning errors with good accuracy. The work described in this paper lays a solid foundation of thermal error prediction and compensation in a feed system based on varying operating conditions and machine tool characteristics.
文摘Lung cancer is one of the most common malignant tumors. It has the highest incidence and mortality rate of all cancers worldwide. Late diagnosis of nonsmall cell lung cancer(NSCLC) is very common in clinical practice, and most patients miss the chance for radical surgery. Thus, radiotherapy plays an indispensable role in the treatment of NSCLC. Radiotherapy technology has evolved from the classic two-dimensional approach to three-dimensional conformal and intensity-modulated radiotherapy. However, how to ensure delivery of an accurate dose to the tumor while minimizing the irradiation of normal tissues remains a huge challenge for radiation oncologists, especially due to the positioning error between fractions and the autonomous movement of organs. In recent years, image-guided radiotherapy(IGRT) has greatly increased the accuracy of tumor irradiation while reducing the irradiation dose delivered to healthy tissues and organs. This paper presents a brief review of the definition of IGRT and the various technologies and applications of IGRT. IGRT can help ensure accurate dosing of the target area and reduce radiation damage to the surrounding normal tissue. IGRT may increase the local control rate of tumors and reduce the incidence of radio-therapeutic complications.
基金Supported by National Key Technology Support Program of China(Grant No.2015BAF07B05)Fundamental Research Funds for the Central Universities of China
文摘Automatic navigation of an articulated drum roller, which is an articulated steering type vehicle widely used in the construction industry, is highly expected for operation cost reduction and improvement of work effi- ciency. In order to achieve the path following control, considering that its steering system is articulated steering and two frames are articulated by an active revolute joint, a kinematic model and an error dynamic state-space equation of an articulated drum roller are proposed. Besides, a state- feedback control law based on Lyapunov stability theory is also designed, which can be proved to achieve the purpose of control by the analysis of stability. What's more, to evaluate the performance of the proposed method, simu- lation under the MATLAB/Simulink and experiments using positioning algorithm and errors correction at the uneven construction site are performed, with initial dis- placement error (-1.5 m), heading error (-0.11 tad) and steering angle (-0.19 rad). Finally, simulation and exper- imental results show that the errors and steering angle can decrease gradually, and converge to zero with time. Meanwhile, the control input is not saturated. An articu- lated drum roller can lock into a desired path with the proposed method in uneven fields.
基金supported by the National Natural Science Foundation of China(61201391)
文摘The measurement of the rolling angle of the projectile is one of the key technologies for the terminal correction projectile.To improve the resolution accuracy of the rolling angle in the laser seeker weapon system, the imaging model of the detector, calculation model of the position and the signal-to-noise ratio(SNR) model of the circuit are built to derive both the correlation between the resolution error of the rolling angle and the spot position, and the relation between the position resolution error and the SNR. Then the influence of each parameter on the SNR is analyzed at large,and the parameters of the circuit are determined. Meanwhile, the SNR and noise voltage of the circuit are calculated according to the SNR model and the decay model of the laser energy. Finally,the actual photoelectric detection circuit is built, whose SNR is measured to be up to 53 d B. It can fully meet the requirement of0.5° for the resolution error of the rolling angle, thereby realizing the analysis of critical technology for photoelectric detection of laser seeker signals.
基金funded by the National Natural Science Foundation of China(Grant No.11303062)
文摘Five-hundred-meter Aperture Spherical radio Telescope(FAST)is the world’s largest single dish radio telescope,which is located in Guizhou Province,in southwest China.The FAST feed cabin is supported and positioned by six steel cables.The deviation of the feed position and orientation would lead to loss in the telescope efficiency.In this paper,a series of electromagnetic(EM)simulations of the FAST facility with varying feed positions and orientation offsets was performed.The maximum gain of FAST is about 82.3 dBi and the sibelobe is–32 dB with respect to the main beam at 3 GHz.The simulation results have demonstrated that the telescope efficiency loss is more sensitive to the lateral feed deviation compared with the axial deviation.The telescope efficiency would decrease by 8.2%due to the FAST feed position deviation of 10 mm rms when the observing frequency is 3 GHz.The FAST feed deviation basically has no effect on the sidelobes and cross polarization characteristic according to the simulations.
文摘Monitoring the performance of any structure requires real-time measurements of the change of position of critical points. Different techniques can be used for this purpose, each one offering advantages and disadvantages. The technique based on satellite positioning systems (GPS, GLONASS and the future GALILEO) seems to be very promising at least for long period structures. The GPS in particular provides sampling rates that are able to track dynamic displacements with high accuracy. Its service ability is independent of atmospheric conditions, temperature variations and visibility of the monitored object. This paper investigates the reliability and accuracy of the measurements of dual frequency GPS receivers. A linear electromagnetic motor moves an object along a given direction. The changes of position are compared witb their estimates as recorded by a GPS receiver, whose antenna is located on the reference object. The comparison is based on sufficiently long records.
文摘This paper proposes a new approach to assess the positional accuracy of maps generated by overlaying multi_scale spatial data layers with different levels of positional accuracy.The existing techniques for assessing the positional accuracy of point,line and polygon features is first examined.Then a taxonomy of graphic features on the derived maps is developed by analyzing the specific processes of overlay operations.Finally,a detailed description of the new approach is provided and the implementation of this new method in practical applications is described.