期刊文献+
共找到31,443篇文章
< 1 2 250 >
每页显示 20 50 100
Ex-PRESS implantation for different types of glaucoma 被引量:3
1
作者 Meltem Guzin Altinel Ayse Yagmur Kanra +1 位作者 Remzi Karadag Huseyin Bayramlar 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第8期1290-1297,共8页
AIM: To evaluate the clinical results, efficacy and safety of Ex-PRESS P200 glaucoma shunt implant in different types of medically uncontrolled glaucoma. METHODS: The study included 31 eyes of 31 patients that were un... AIM: To evaluate the clinical results, efficacy and safety of Ex-PRESS P200 glaucoma shunt implant in different types of medically uncontrolled glaucoma. METHODS: The study included 31 eyes of 31 patients that were unresponsive to medical antiglaucomatous therapy in whom Ex-PRESS P200 glaucoma shunt implantation was performed. The demographic characteristics of the patients, type of glaucoma, complete ocular examination results, number of antiglaucomatous drugs before and after surgery, early and late complications of surgery, additional surgical and nonsurgical medical interventions, and success rates were investigated from the patients’ files, retrospectively. RESULTS: The mean postoperative follow-up time was 16.4±7.5 mo. The preoperative mean corrected intraocular pressure(IOP) was 28.7±10.3 mm Hg and postoperative mean corrected IOP was 15.3±5.2 mm Hg(P<0.05) at the last visit. The mean IOP reduction was 39.9% when the preoperative and postoperative values of the last visits were compared. The average number of antiglaucomatous drug use decreased from 3.9±0.3 to 1.7±1.7 postoperatively(P<0.05). The use of antiglaucomatous medications at the last visit was more than in other studies in the literature. The most common complication was conjunctival leakage, which was seen in 7 patients. Other early complications were iris touch, intravitreal hemorrhage, hyphema, choroidal effusion, early transient hypotonia and corneal edema. One of the late complications was endophthalmitiswhich was seen in one case 6 mo after the operation, and the other late complication was opacification of the cornea in one patient. Twelve additional surgical operations associated to Ex-PRESS surgery and 3 bleb needling have done. At the last visit, the complete success rate was 32.3% and the qualified success rate was 77.5% in all patients. CONCLUSION: Ex-PRESS P200 glaucoma shunt implantation may be an effective procedure for medically uncontrolled glaucoma with significantly lower use of antiglaucomatous medications. 展开更多
关键词 GLAUCOMA ex-press implant GLAUCOMA SURGERY
下载PDF
Ex-PRESS implantation versus trabeculectomy in Chinese patients with POAG:fellow eye pilot study 被引量:7
2
作者 Wei Wang Min-Wen Zhou +2 位作者 Wen-Bin Huang Xin-Bo Gao Xiu-Lan Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第1期56-60,共5页
AIM: To compare the outcomes of Ex-PRESS implantation in one eye versus trabeculectomy with mitomycin C in the fellow eye in Chinese patients with primary open-angle glaucoma (POAG). METHODS: This was a prospectiv... AIM: To compare the outcomes of Ex-PRESS implantation in one eye versus trabeculectomy with mitomycin C in the fellow eye in Chinese patients with primary open-angle glaucoma (POAG). METHODS: This was a prospective, non-randomized comparative study. Forty-eight eyes of 24 patients with bilateral POAG necessitating surgery were included and underwent Ex-PRESS implantation under the scleral flap in one eye and trabeculectomy in the other eye according to patients’ choice. Primary outcome measures included mean intraocular pressure (IOP) and success rate. Secondary outcome measures were aqueous flare, postoperative medication use, visual acuity, and incidence of complications.RESULTS: All 24 patients finished a 1-year follow-up. Both groups maintained significant reductions in IOP after surgery throughout the follow-up period. At any point in time, the IOP of the two groups did not differ significantly. The Kaplan-Meier survival curve analysis showed no significant differences in success between the two groups (P=0.289). The mean number of anti-glaucoma medicines and visual acuity in both groups were not significantly different. Eyes with Ex-PRESS implantation had lower aqueous flare values on days 1 and 3 (both P〈0.05). Instances of early postoperative hypotony and choroidal effusion were significantly fewer in frequency after Ex-PRESS implantation under the scleral flap compared with those after trabeculectomy (P〈0.001). CONCLUSION: Ex-PRESS is comparable to trabeculectomy in terms of IOP, success rate, number of glaucoma medications used, and visual acuity. However, Ex-PRESS resulted in fewer cases of inflammation and a lower rate of complications. 展开更多
关键词 ex-press TRABECULECTOMY primary open-angle glaucoma CHINESE
下载PDF
Ex-PRESS implantation with phacoemulsification in POAG versus CPACG 被引量:4
3
作者 Jie Lan Da-Peng Sun +2 位作者 Jie Wu Ya-Ni Wang Li-Xin Xie 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第1期51-55,共5页
AIM: To compare the long-term outcomes of the Ex-PRESS miniature glaucoma device implanted under a scleral flap in combination of phacoemulsification with intraocular lens implantation in primary open angle glaucoma ... AIM: To compare the long-term outcomes of the Ex-PRESS miniature glaucoma device implanted under a scleral flap in combination of phacoemulsification with intraocular lens implantation in primary open angle glaucoma (POAG) and chronic primary angle-closure glaucoma (CPACG).METHODS: Retrospective, comparative study. A total of 60 eyes (60 patients) receiving the Ex-PRESS miniature glaucoma device implantation combined with phacoemulsification were reviewed. Thirty eyes (30 patients) had the combined procedures for POAG, and the other 30 eyes (30 patients) for CPACG. RESULTS: The follow-up was 39.37±7.09mo (range 3 to 49mo) in patients with POAG and 37.10±9.26mo (range 9 to 49mo) in patients with CPACG (P=0.29). The mean change in best corrected visual acuity was 0.41 logMAR for POAG and 0.38 logMAR for CPACG at the last follow-up (P=0.22). The postoperative intraocular pressure (IOP) of the POAG group was significantly lower than the CPACG group at 1, 3, 12, and 18mo after surgery (P=0.02, 0.00, 0.04, 0.01) with similar glaucoma medications after surgery (P〉0.16). At 3y after surgery, the cumulative complete and qualified success rates were 63.3% (POAG) and 53.3% (CPACG), 83.3% (POAG) and 73.3% (CPACG) (P=0.41, 0.49), respectively. The POAG group had more hypotony than the CPACG group (P=0.04).CONCLUSION: The long-term outcomes show the Ex-PRESS implantation combined with phacoemulcification can effectively lower the IOP in both the POAG and CPACG groups. The POAG group seems to have lower postoperative IOP and a higher risk of hypotony. 展开更多
关键词 GLAUCOMA ex-press miniature glaucomadevice cataract surgery PHACOEMULSIFICATION
下载PDF
Is primary transcatheter aortic valve implantation the new normal?
4
作者 R.Anantharaman C.Sundar +1 位作者 Kamal Kant Jena K.Arun 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2024年第4期458-461,共4页
Degenerative calcific aortic valve stenosis(AS)is the most common valvular heart disease in elderly.^[1] It is well documented that symptomatic severe AS follows a malignant course leading to cardiogenic shock(CS).
关键词 AORTIC STENOSIS implantation
下载PDF
Nursing Care and Causative Analysis of Grade IV Capsular Contracture Following Breast Cancer Expander Implantation
5
作者 Rong Chen Nan Zhang Huiting Zhang 《Advances in Breast Cancer Research》 CAS 2024年第1期1-9,共9页
Objective: By observing the treatment and nursing care of a patient with Grade IV capsular contracture following breast cancer expander implantation and subsequent Stage II reconstruction, we aim to analyze the reason... Objective: By observing the treatment and nursing care of a patient with Grade IV capsular contracture following breast cancer expander implantation and subsequent Stage II reconstruction, we aim to analyze the reasons for the formation of capsular contracture after Stage I expander implantation and prevent its recurrence following Stage II reconstruction. Methods: In May 2020, the patient noticed an increase in the size of a breast mass. In August, she underwent AC-THP neoadjuvant chemotherapy, followed by a “right breast-conserving nipple-areolar subglandular excision + right axillary lymph node dissection + expander implantation” surgery in November 2020. Radiation therapy began in January 2021. During radiation therapy, the patient experienced severe breast hardening, distortion, tenderness, and was diagnosed with Grade IV capsular contracture. To relieve the capsular contracture, the patient underwent a “contracted capsule incision and release procedure + removal of the right breast expander + right breast implantation” surgery in July 2021. Postoperatively, measures were taken to prevent incision infection, emphasizing aseptic techniques, ensuring smooth negative pressure drainage, reducing skin flap tension, monitoring skin flap blood supply, actively preventing subcutaneous effusion and hematoma, and applying appropriate compression dressings. Results: The patient was discharged after the removal of the drainage tube. During the postoperative follow-up at 3 and 6 months, there was no recurrence of capsular contracture, and the breast appeared full, upright, and relatively soft. There were no complications such as hematoma, infection, breast implant rupture, breast sagging, or displacement. The patient had a good outcome without additional financial or surgical burdens. Conclusion: The occurrence of Grade IV capsular contracture in the patient is generally related to infection after Stage I expander implantation, improper compression dressing, excessive saline injection causing content infiltration, and radiation therapy. Therefore, it is recommended to enhance the intraoperative and postoperative prophylactic use of antibiotics after Stage I expander implantation. Intermittent saline injection after surgery, with the amount of saline gradually increasing rather than filling all at once, is advisable. This helps the breast tissue gradually adapt to expansion, reducing the risk of capsular contracture. Postoperatively, patients should be instructed to wear pressure garments and breast elastic bandages while intensifying breast monitoring during radiation therapy and increasing postoperative follow-up. 展开更多
关键词 Breast Cancer Capsular Contracture Expander implantation
下载PDF
In‑depth proteome characterization of endometrium and extraembryonic membranes during implantation in pig
6
作者 Maria A.Gil Josep M.Cambra +3 位作者 Heriberto Rodriguez‑Martinez Cristina Cuello Inmaculada Parrilla Emilio A.Martinez 《Journal of Animal Science and Biotechnology》 SCIE CAS CSCD 2024年第3期1027-1055,共29页
Background Proteome characterization of the porcine endometrium and extraembryonic membranes is important to understand mother-embryo cross-communication.In this study,the proteome of the endometrium and cho-rioallant... Background Proteome characterization of the porcine endometrium and extraembryonic membranes is important to understand mother-embryo cross-communication.In this study,the proteome of the endometrium and cho-rioallantoic membrane was characterized in pregnant sows(PS)during early gestation(d 18 and 24 of gestation)and in the endometrium of non-pregnant sows(NPS)during the same days using LC-MS/MS analysis.The UniProtKB database and ClueGO were used to obtain functional Gene Ontology annotations and biological and functional networks,respectively.Results Our analysis yielded 3,254 and 3,457 proteins identified in the endometrium of PS and NPS,respectively;of these,1,753 being common while 1,501 and 1,704 were exclusive to PS and NPS,respectively.In addition,we iden-tified 3,968 proteins in the extraembryonic membranes of PS.Further analyses of function revealed some proteins had relevance for the immune system process and biological adhesion in endometrium while the embryonic chorion displayed abundance of proteins related to cell adhesion and cytoskeletal organization,suggesting they dominated the moment of endometrial remodeling,implantation and adhesion of the lining epithelia.Data are available via Pro-teomeXchange with identifier PXD042565.Conclusion This is the first in-depth proteomic characterization of the endometrium and extraembryonic mem-branes during weeks 3 to 4 of gestation;data that contribute to the molecular understanding of the dynamic environ-ment during this critical period,associated with the majority of pregnancy losses. 展开更多
关键词 ENDOMETRIUM Extraembryonic membranes implantation PIG PROTEOME
下载PDF
Glaucoma drainage device implantation and cyclophotocoagulation in the management of refractory glaucoma after Descemet-stripping automated endothelial keratoplasty
7
作者 Min-Shu Wang Xue-Chuan Dong +4 位作者 Mi-Yun Zheng Xiang Fan Ge-Ge Xiao Jing Hong Ling-Ling Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期257-264,共8页
AIM:To compare the surgical outcomes of glaucoma drainage device implantation(GDI)and trans-scleral neodymium:YAG cyclophotocoagulation(CPC)in the management of refractory glaucoma after Descemetstripping automated en... AIM:To compare the surgical outcomes of glaucoma drainage device implantation(GDI)and trans-scleral neodymium:YAG cyclophotocoagulation(CPC)in the management of refractory glaucoma after Descemetstripping automated endothelial keratoplasty(DSAEK).METHODS:This retrospective study on observational case series enrolled 29 patients who underwent DSAEK and posterior anti-glaucoma surgery(15 with GDI and 14 with CPC).The main outcome measures were intraocular pressure(IOP),glaucoma surgery success rate(defined as IOP of 6–21 mm Hg without additional anti-glaucoma operation),number of glaucoma medications,endothelial graft status,and best-corrected visual acuity(BCVA).RESULTS:The mean follow-up time was 34.1 and 21.0mo for DSAEK or glaucoma surgeries,both for the GDI and CPC groups.Both groups showed significant IOP reduction after glaucoma surgery.The GDI group presented a significantly higher success rate in IOP control than the CPC group(60%vs 21.4%,P=0.03).Both procedures significantly decreased the number of glaucoma medications(P=0.03).Forty percent and 57%of cases in the GDI and the CPC group,respectively,experienced endothelial graft failure during follow-up(P=0.36).Significantly worse BCVA after surgery was observed in the CPC group but not in the GDI group.CONCLUSION:Both GDI and CPC significantly decrease IOP in eyes with glaucoma after DSAEK.GDI is preferable to CPC in refractory glaucoma cases after DSAEK,as it manifests a significantly higher success rate for IOP control,similar endothelial graft failure rate,and relatively preserves BCVA than CPC. 展开更多
关键词 glaucoma drainage device implantation CYCLOPHOTOCOAGULATION refractory glaucoma Descemetstripping automated endothelial keratoplasty
下载PDF
Embryo Transfer Strategies for Women with Recurrent Implantation Failure During the Frozen-thawed Embryo Transfer Cycles:Sequential Embryo Transfer or Double-blastocyst Transfer?
8
作者 Qiao-hang ZHAO Yu-wei SONG +8 位作者 Jian CHEN Xiang ZHOU Ji-lai XIE Qiu-ping YAO Qi-yin DONG Chun FENG Li-ming ZHOU Wei-ping FU Min JIN 《Current Medical Science》 SCIE CAS 2024年第1期212-222,共11页
Objective Both sequential embryo transfer(SeET)and double-blastocyst transfer(DBT)can serve as embryo transfer strategies for women with recurrent implantation failure(RIF).This study aims to compare the effects of Se... Objective Both sequential embryo transfer(SeET)and double-blastocyst transfer(DBT)can serve as embryo transfer strategies for women with recurrent implantation failure(RIF).This study aims to compare the effects of SeET and DBT on pregnancy outcomes.Methods Totally,261 frozen-thawed embryo transfer cycles of 243 RIF women were included in this multicenter retrospective analysis.According to different embryo quality and transfer strategies,they were divided into four groups:group A,good-quality SeET(GQ-SeET,n=38 cycles);group B,poor-quality or mixed-quality SeET(PQ/MQ-SeET,n=31 cycles);group C,good-quality DBT(GQ-DBT,n=121 cycles);and group D,poor-quality or mixed-quality DBT(PQ/MQ-DBT,n=71 cycles).The main outcome,clinical pregnancy rate,was compared,and the generalized estimating equation(GEE)model was used to correct potential confounders that might impact pregnancy outcomes.Results GQ-DBT achieved a significantly higher clinical pregnancy rate(aOR 2.588,95%CI 1.267–5.284,P=0.009)and live birth rate(aOR 3.082,95%CI 1.482–6.412,P=0.003)than PQ/MQ-DBT.Similarly,the clinical pregnancy rate was significantly higher in GQ-SeET than in PQ/MQ-SeET(aOR 4.047,95%CI 1.218–13.450,P=0.023).The pregnancy outcomes of GQ-SeET were not significantly different from those of GQ-DBT,and the same results were found between PQ/MQ-SeET and PQ/MQ-DBT.Conclusion SeET relative to DBT did not seem to improve pregnancy outcomes for RIF patients if the embryo quality was comparable between the two groups.Better clinical pregnancy outcomes could be obtained by transferring good-quality embryos,no matter whether in SeET or DBT.Embryo quality plays a more important role in pregnancy outcomes for RIF patients. 展开更多
关键词 recurrent implantation failure sequential embryo transfer frozen-thawed embryo transfer embryo transfer strategies
下载PDF
Current knowledge for the risk factors of early permanent pacemaker implantation following transcatheter aortic valve replacement and what is next for the primary prevention?
9
作者 Gen-Min Lin Wei-Chun Huang Chih-Lu Han 《World Journal of Cardiology》 2024年第2期54-57,共4页
In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from... In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from several renowned clinical studies and focused on the primary prevention of managing the modifiable factors,e.g.,paroxysmal atrial fibrillation before the TAVR. 展开更多
关键词 Permanent pacemaker implantation Transcatheter aortic valve replacement Interventricular conduction delay DIABETES Supraventricular arrhythmia
下载PDF
Effect of capsule treatment on visual acuity and quality after phacoemulsification lens implantation in myopic patients with cataract
10
作者 Wei Liu Qi Liu +2 位作者 Fang Zhou Bo Feng Wan-Ling Wu 《World Journal of Clinical Cases》 SCIE 2024年第19期3882-3889,共8页
BACKGROUND Cataracts pose a significant clinical burden due to their complex pathogenesis.In recent years,an increase in cataracts coexisting with myopia has heightened the incidence of retinopathy and posterior vitre... BACKGROUND Cataracts pose a significant clinical burden due to their complex pathogenesis.In recent years,an increase in cataracts coexisting with myopia has heightened the incidence of retinopathy and posterior vitreous detachment.Additionally,symptoms of ocular axis elongation,lens nucleus hardening,and vitreous liquefaction have become more prevalent.While conventional extracapsular cataract extraction is commonly employed,it often yields suboptimal visual outcomes.Subsequent advancements in cataract phacoemulsification and lens implantation surgeries have gained widespread acceptance for their ability to improve refraction and significantly improve uncorrected visual acuity.AIM To investigate the effect of capsular treatment after phacoemulsification lens implantation in myopic patients with cataract.METHODS We selected 110 patients(with 134 eyes)with myopia and cataracts treated.These patients were categorized into two groups:an observation group(57 patients with 70 eyes)and a control group(53 patients with 64 eyes).The control group underwent cataract phacoemulsification and lens implantation,while the observation group received a refined capsular treatment based on the control group’s procedure.We assessed the differences in visual acuity and quality between the two groups before and after surgery.RESULTS At six months post-operation,the observation group exhibited significantly improved far vision,intermediate vision,near vision,lower objective scattering index,higher Modulation transfer function cut-off frequency,and overall vision metrics at different contrast levels(100%,20%and 9%)compared to the control group(P<0.05).The total score of the National Eye Institute Visual Function Questionnaire in the observation group at 6 months after operation was significantly higher than that in the control group(P<0.05).No significant difference in the incidence of adverse reactions was observed between the observation group and control group(P>0.05).CONCLUSION Capsular treatment demonstrates efficacy in improving visual acuity and quality after phacoemulsification lens implantation in myopic patients with cataracts,warranting its clinical application. 展开更多
关键词 Capsular treatment MYOPIA CATARACT Phacoemulsification and lens implantation Visual acuity Visual quality Uncorrected visual acuity
下载PDF
Effects of systematic cardiac rehabilitation training in elderly patients with unstable angina following cardiac stent implantation
11
作者 Ling-Ling Yan Xue Yang +1 位作者 Lu Chen Xiao Lu 《World Journal of Clinical Cases》 SCIE 2024年第20期4137-4145,共9页
BACKGROUND Coronary stent implantation is usually used to treat unstable angina to alleviate stenosis or occlusion,promoting blood flow restoration and alleviating symptoms such as myocardial ischemia.And postoperativ... BACKGROUND Coronary stent implantation is usually used to treat unstable angina to alleviate stenosis or occlusion,promoting blood flow restoration and alleviating symptoms such as myocardial ischemia.And postoperative cardiac rehabilitation is essential for enhancing recovery and prognosis.Nevertheless,conventional rehabilitation lacks specificity,particularly for elderly patients with multiple comorbidities and poor compliance,rendering it less effective.AIM To investigate the effects of systematic cardiac rehabilitation training in elderly patients with unstable angina following coronary stenting intervention.METHODS A retrospective enrollment was conducted comprising fifty-four elderly patients with unstable angina pectoris who underwent systematic cardiac rehabilitation training after receiving coronary intervention as the rehabilitation group,while fifty-three elderly patients who received basic nursing and rehabilitation guidance measures after coronary intervention were assigned to the control group.Differences in Seattle Angina Questionnaire scores,survival quality(SF-36)scores,cardiopulmonary exercise function assessment index,echocardiographic cardiac function index,and adverse cardiovascular events were compared between the two groups.RESULTS After intervention,the rehabilitation group observed greater VO2 Max,maximum metabolic equivalent,eft ventricular ejection fraction,left ventricular end-diastolic diameter and smaller left ventricular end-systolic diameter.And the rehabilitation group observed greater scores of physical activity limitation,stable angina pectoris,treatment satisfaction,and SF-36 score.The incidence of adverse cardiovascular events in the two groups,showed no significant difference.CONCLUSION Systematic cardiac rehabilitation following coronary stenting in elderly patients with unstable angina pectoris can enhance cardiac function recovery,consequently enhancing both quality of life and cardiopulmonary exercise tolerance. 展开更多
关键词 Systematicity Cardiac rehabilitation training Unstable angina pectoris Coronary stenting implantation Interventional surgery Quality of life Cardiac function Exercise tolerance
下载PDF
Effects of Continuous Precision Nursing Model on Knowledge, Attitudes, and Practices (KAP) Behavior and Cardiac Function in Patients after Percutaneous Coronary Angiography and Stent Implantation
12
作者 Cuiying Han 《Journal of Clinical and Nursing Research》 2024年第3期1-6,共6页
Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary a... Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary angiography and stent implantation.Methods:Ninety patients who underwent percutaneous coronary angiography and stent implantation in our hospital from April 2022 to April 2023 were selected and randomly divided into the control group(45 cases),in which routine nursing support was carried out during the treatment process,and the observation group(45 cases),in which continuous precision nursing model was carried out during the treatment process.Comparisons were made between the two groups of patients on their KAP,cardiac function,and quality of life during recovery.Results:There was no difference in the left ventricular ejection fraction(LVEF),cardiac output(CO),and cardiac index(CI)levels before intervention.After the intervention,the levels of cardiac function in the observation group were higher than those of the control group(P<0.05).There was no difference in the Exercise of Self-Care Agency(ESCA)self-care ability scale scores before the intervention.After the intervention,the observation group had higher ESCA scores than the control group(P<0.05).Conclusion:Implementation of a continuous precision nursing model in the care of patients undergoing percutaneous coronary angiography and stent implantation improved the patient’s cardiac function,and KAP,and promoted recovery. 展开更多
关键词 Continuous precision nursing model Percutaneous coronary angiography Stent implantation Knowledge attitudes and practices(KAP) Cardiac function
下载PDF
Trabeculectomy with Ex-PRESS implant versus Ahmed glaucoma valve implantation-a comparative study 被引量:5
13
作者 Michael Waisbourd Naomi Fischer +5 位作者 Hadas Shalev Oriel Spierer Elad Ben Artsi Rony Rachmiel Gabi Shemesh Shimon Kurtz 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第10期1415-1420,共6页
AIM:To compare the surgical outcomes of trabeculectomy with Ex-PRESS implant and Ahmed glaucoma valve(AGV) implantation. METHODS: Patients who underwent trabeculectomy with Ex-PRESS implants or AGV implantation se... AIM:To compare the surgical outcomes of trabeculectomy with Ex-PRESS implant and Ahmed glaucoma valve(AGV) implantation. METHODS: Patients who underwent trabeculectomy with Ex-PRESS implants or AGV implantation separately were included in this retrospective chart review.Main outcome measures were surgical failure and complications.Failure was defined as intraocular pressure(IOP) 〉21 mm Hg or 〈5 mm Hg on two consecutive visits after 3mo,reoperation for glaucoma,or loss of light perception.Eyes that had not failed were considered as complete success if they did not required supplemental medical therapy.RESULTS: A total of 64 eyes from 57 patients were included: 31 eyes in the Ex-PRESS group and 33 eyes in the AGV group.The mean follow-up time was 2.6 ±1.1y and 3.3±1.6y,respectively.Patients in the AGV group had significantly higher baseline mean IOP(P =0.005),lower baseline mean visual acuity(VA)(P =0.02),and higher proportion of patients with history of previous trabeculectomy(P 〈0.0001).Crude failure rates were 16.1%,n =5/31 in the Ex-PRESS group and 24.2%,n =8/33 in the AGV group.The cumulative proportion of failure was similar between the groups,P =0.696.The proportion of eyes that experienced postoperative complications was32.3% in the Ex-PRESS group and 60.1% in the AGV group(P =0.0229).CONCLUSION: Trabeculectomy with Ex-PRESS implant and AGV implantation had comparable failure rates.The AGV group had more post-operative complications,but also included more complex cases with higher baselinemean IOP,worse baseline mean VA,and more previous glaucoma surgeries.Therefore,the results are limited to the cohort included in this study. 展开更多
关键词 ex-press glaucoma implant TRABECULECTOMY Ahmed glaucoma valve implantation
下载PDF
Postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens implantation versus small incision lenticule extraction in myopic eyes:a Meta-analysis 被引量:2
14
作者 Hong-Yu Li Zi Ye Zhao-Hui Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第3期442-452,共11页
AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,W... AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,Web of Science,Cochrane Library and several Chinese databases were searched at May 2021 to select relevant studies in comparison of clinical outcomes between ICL implantation and SMILE for myopia.The primary outcomes were efficacy,safety,and predictability.And the secondary outcomes were postoperative higher-order ocular aberrations(HOAs),modulation transfer function cutoff frequency(MTF),objective scatter index(OSI),contrast sensitivity and a quality of vision(Qo V)questionnaire.RESULTS:A total of 1036 eyes from 10 studies,of which 503 eyes underwent ICL implantation and 533 eyes underwent SMILE,were enrolled in this Meta-analysis.Pooled results revealed that ICL group had a better safety index and post-corrected distance visual acuity(CDVA)(P=0.007,<0.00001,respectively),and a lower percentage of eyes with a postoperative CDVA lost 1 line(P=0.007)than the SMILE group.No significant differences were found in comparison of the other primary outcomes.In the longterm follow-up(>6mo),ICL group had a lower total HOA,coma,and spherical aberration than SMILE group(P=0.003,<0.00001,0.04).Yet higher trefoil was found in ICL group at 6mo after surgery(P=0.003).Additionally,ICL group also had a higher MTF value(P=0.02),and a higher contrast sensitivity score for spatial frequencies of 1.5,6,and 12 cpds(P=0.02,0.005,0.02,respectively).And it also had a lower score of bothersome in Qo V questionnaire than SMILE group(P=0.003).CONCLUSION:ICL implantation and SMILE have similar and comparable outcomes in term of the efficacy and predictability for correcting high myopia.However,ICL group is relatively safer and also has better visual quality in comparison of SMILE group. 展开更多
关键词 implantable collamer lens small incision lenticule extraction MYOPIA refractive surgery META-ANALYSIS
下载PDF
Long-term observation on safety and visual quality of implantable collamer lens V4c implantation for myopia correction:a 5-year follow-up 被引量:2
15
作者 Xiao Chen Li Li +4 位作者 Jing Rao Yue-Xi Chen Yang Gao Rui-Xue Huang Qi-Zhi Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第7期1123-1129,共7页
AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted... AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted on 58 patients(114 eyes)who were followed up for at least 5y after ICL V4c implantation.The observation was done before and on 1d,1mo,1 and 5y or more after the surgical procedure.The visual acuity,subjective refraction,intraocular pressure,vault,axial length,central hole position,pupil diameter,visual quality,and adverse events were analyzed.The visual quality includes aberration,the modulation transfer function cutoff frequency(MTF cutoff),objective scattering index(OSI),Stroller's ratio(SR),and visual quality questionnaire.RESULTS:The average follow-up period was 69.25±3.80mo(range 60–82mo)and the preoperative spherical equivalent(SE)was-8.66±1.97 D.At 5y after operation,the safety index was 1.01±0.02 and the efficacy index was 0.99±0.42 and SE was-0.65±0.63 D.The 59.6%of the eyes achieved an uncorrected distance visual acuity of 20/20,76.3%of the eyes had SE within±1.0 D at the last visit.The axial length increased by 0.29±0.71 mm 5y after the surgery(t=-3.843,P<0.001).The mean vault at the last follow-up was 510.59±245.61μm.The central hole was on the temporal side in 80 eyes(84.2%).The visual quality questionnaire showed that 98.2%patients were satisfied with the surgical procedure.Adverse events occurred in 4 eyes(3.5%),including the posttraumatic toric ICL rotation(2 eyes),iris incarceration(1 eye),and posttraumatic ICL displacement(1 eye)at the last follow-up.CONCLUSION:Long-term ICL V4c implantation is safe,effective,and stable for correcting moderate and to high myopia,and the visual quality with patients is excellent and satisfactory,but the progression of axial length still needs attention after surgery. 展开更多
关键词 implantable collamer lens with central hole myopia correction refractive surgery visual quality
下载PDF
The role of cochlear implantation in alleviating Tumarkin drop attacks of Meniere's disease;a case report 被引量:1
16
作者 Chiara Filippi Edoardo Covelli +2 位作者 Haitham H.Elfarargy Simonetta Monini Maurizio Barbara 《Journal of Otology》 CAS CSCD 2023年第3期168-172,共5页
Ménière’s disease(MD)patients may suffer episodes of sudden falls,named Tu markin drop attacks(DAs).This fall occurs abruptly and without warning or loss of consciousness.DAs usually aggravate the clinical ... Ménière’s disease(MD)patients may suffer episodes of sudden falls,named Tu markin drop attacks(DAs).This fall occurs abruptly and without warning or loss of consciousness.DAs usually aggravate the clinical picture of MD and are challenging to manage.The present report describes a case treated by cochlear implantation(CI)due to concomitant deafness and offers some clinical considerations for this condition.A male patient aged 48 years with a 10-year history of definite bilateral MD had profound SNHL on the right and severe SNHL on the left side.He suffered from intermittent attacks of vertigo,ear fullness,and tinnitus and,in the last year,had developed DAs and experienced 14 episodes in the previous six months.The preoperative category of acoustic performance was 3.The Dizziness Handicap Inventory(DHI)questionnaire showed a total score of 46,which indicated a moderate degree of disability.A CI was planned for the right side.The patient did not report any further DAs episode for two years since then.The postoperative category of acoustic performance became 11,and the postoperative DHI questionnaire showed a decrease in the total score(from 46 to 19),which indicated a mild disability.Unilateral CI effectively alleviated the DAs associated with bilateral MD.Our report proposes a new modality for managing vertiginous symptoms in cases of MD with hearing loss without the need for more aggressive surgical interventions with the need for clinical trials to confirm our results. 展开更多
关键词 Meniere's disease Tumarkin drop attacks Hearing loss Cochlear implant
下载PDF
Prolonged dual antiplatelet therapy after drug-eluting stent implantation improves long-term prognosis for acute coronary syndrome:five-year results from a large cohort study 被引量:1
17
作者 Jing-jing Xu Si-da Jia +11 位作者 Lin Jiang Ying Song Pei Zhu De-shan Yuan Yi Yao Xue-yan Zhao Jian-xin Li Yue-jin Yang Shu-bin Qiao Bo Xu Run-lin Gao Jin-qing Yuan 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2023年第1期25-30,共6页
BACKGROUND:To investigate the most appropriate dual antiplatelet therapy(DAPT)duration for patients with acute coronary syndrome(ACS)after drug-eluting stent(DES)implantation in the largest cardiovascular center of Ch... BACKGROUND:To investigate the most appropriate dual antiplatelet therapy(DAPT)duration for patients with acute coronary syndrome(ACS)after drug-eluting stent(DES)implantation in the largest cardiovascular center of China.METHODS:We enrolled 5,187 consecutive patients with ACS who received DES from January to December 2013.Patients were divided into four groups based on DAPT duration:standard DAPT group(11-13 months,n=1,568)and prolonged DAPT groups(13-18 months[n=308],18-24 months[n=2,125],and>24 months[n=1,186]).Baseline characteristics and 5-year clinical outcomes were recorded.RESULTS:Baseline characteristics were similar across the four groups.Among the four groups,those with prolonged DAPT(18-24 months)had the lowest incidence of major adverse cardiovascular and cerebrovascular events(MACCEs)(14.1%vs.11.7%vs.9.6%vs.24.2%,P<0.001),all-cause death(4.8%vs.3.9%vs.2.1%vs.2.6%,P<0.001),cardiac death(3.1%vs.2.6%vs.1.4%vs.1.9%,P=0.004),and myocardial infarction(MI)(3.8%vs.4.2%vs.2.5%vs.5.8%,P<0.001).The incidence of bleeding was not different among the four groups(9.9%vs.9.4%vs.11.0%vs.9.4%,P=0.449).Cox multivariable analysis showed that prolonged DAPT(18-24 months)was an independent protective factor for MACCEs(hazard ratio[HR]0.802,95%confidence interval[CI]0.729-0.882,P<0.001),all-cause death(HR 0.660,95%CI 0.547-0.795,P<0.001),cardiac death(HR 0.663,95%CI 0.526-0.835,P<0.001),MI(HR 0.796,95%CI 0.662-0.957,P=0.015),and target vessel revascularization(HR 0.867,95%CI 0.755-0.996,P=0.044).Subgroup analysis for high bleeding risk showed that prolonged DAPT remained an independent protective factor for all-cause death and MACCEs.CONCLUSION:For patients with ACS after DES,appropriately prolonging the DAPT duration may be associated with a reduced risk of adverse ischemic events without increasing the bleeding risk. 展开更多
关键词 Dual antiplatelet therapy Acute coronary syndrome Drug-eluting stent implantation
下载PDF
A Custom Manipulator for Dental Implantation Through Model-Based Design 被引量:1
18
作者 Anitha Govindhan Karnam Anantha Sunitha Sivanathan Kandhasamy 《Intelligent Automation & Soft Computing》 SCIE 2023年第1期351-365,共15页
This paper presents a Model-Based Design(MBD)approach for the design and control of a customized manipulator intended for drilling and position-ing of dental implants accurately with minimal human intervention.While p... This paper presents a Model-Based Design(MBD)approach for the design and control of a customized manipulator intended for drilling and position-ing of dental implants accurately with minimal human intervention.While performing an intra-oral surgery for a prolonged duration within a limited oral cavity,the tremor of dentist's hand is inevitable.As a result,wielding the drilling tool and inserting the dental implants safely in accurate position and orientation is highly challenging even for experienced dentists.Therefore,we introduce a customized manipulator that is designed ergonomically by taking in to account the dental chair specifications and anthropomorphic data such that it can be readily mounted onto the existing dental chair.The manipulator can be used to drill holes for dental inserts and position them with improved accuracy and safety.Further-more,a thorough multi-body motion analysis of the manipulator was carried out by creating a virtual prototype of the manipulator and simulating its controlled movements in various scenarios.The overall design was prepared and validated in simulation using Solid works,MATLAB and Simulink through Model Based Design(MBD)approach.The motion simulation results indicate that the manipulator could be built as a prototype readily. 展开更多
关键词 Model based design multi-body motion simulation custom manipulator orthodontic implants mathematical approach
下载PDF
Role of dendritic cells in MYD88-mediated immune recognition and osteoinduction initiated by the implantation of biomaterials
19
作者 Zifan Zhao Qin Zhao +6 位作者 Hu Chen Fanfan Chen Feifei Wang Hua Tang Haibin Xia Yongsheng Zhou Yuchun Sun 《International Journal of Oral Science》 SCIE CAS CSCD 2023年第3期411-421,共11页
Bone substitute material implantation has become an important treatment strategy for the repair of oral and maxillofacial bone defects.Recent studies have shown that appropriate inflammatory and immune cells are essen... Bone substitute material implantation has become an important treatment strategy for the repair of oral and maxillofacial bone defects.Recent studies have shown that appropriate inflammatory and immune cells are essential factors in the process of osteoinduction of bone substitute materials.Previous studies have mainly focused on innate immune cells such as macrophages.In our previous work,we found that T lymphocytes,as adaptive immune cells,are also essential in the osteoinduction procedure.As the most important antigen-presenting cell,whether dendritic cells(DCs)can recognize non-antigen biomaterials and participate in osteoinduction was still unclear.In this study,we found that surgical trauma associated with materials implantation induces necrocytosis,and this causes the release of high mobility group protein-1(HMGB1),which is adsorbed on the surface of bone substitute materials.Subsequently,HMGB1-adsorbed materials were recognized by the TLR4-MYD88-NFκB signal axis of dendritic cells,and the inflammatory response was activated.Finally,activated DCs release regeneration-related chemokines,recruit mesenchymal stem cells,and initiate the osteoinduction process.This study sheds light on the immune-regeneration process after bone substitute materials implantation,points out a potential direction for the development of bone substitute materials,and provides guidance for the development of clinical surgical methods. 展开更多
关键词 implantation BIOMATERIALS release
下载PDF
Transcatheter aortic valve implantation in a patient with anomalous right coronary artery originating from the left aortic sinus with interarterial course
20
作者 Lu-Chen WANG Yan-Xiang LIU +1 位作者 Xiao-Gang SUN Wei WANG 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2023年第8期612-614,共3页
Recently,the utilization of transcatheter aortic valve implantation(TAVI)has gained increasing prevalence due to its expanding range of applications in managing symptomatic severe aortic stenosis(AS).Coronary obstruct... Recently,the utilization of transcatheter aortic valve implantation(TAVI)has gained increasing prevalence due to its expanding range of applications in managing symptomatic severe aortic stenosis(AS).Coronary obstruction,a life-threatening complication,has been reported to occur during and after TAVI at an incidence rate of 0.5%-1%.^([1])In addition to shallow sinus of Valsalva(less than 30 mm),low coronary take-off(below 12 mm from annulus plane),and calcification of native valve leaflets over the coronary ostium,anomalous origins of coronary arteries and compression from expanded transcatheter heart valve have been shown to cause TAVI-associated coronary occlusion. 展开更多
关键词 CORONARY AORTIC implantation