期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
A METHOD OF ESTIMATING THE INFLUENCE OF EXPERIMENTAL ERRORS ON THE EXPERIMENTAL RESULTS OF MATERIAL PARAMETERS AND THE CRITERIA TO VALUE THIS INFLUENCE
1
作者 Yao Weixing Tsinghua University 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 1991年第3期320-325,共6页
In this paper the main sources causing the scatter of the experimental results of the material parameters are discussed. They can be divided into two parts: one is the experimental errors which are introduced because ... In this paper the main sources causing the scatter of the experimental results of the material parameters are discussed. They can be divided into two parts: one is the experimental errors which are introduced because of the inaccuracy of experimental equipment, the experimental techniques, etc., and the form of the scatter caused by this source is called external distribution. The other is due to the irregularity and inhomogeneity of the material structure and the randomness of deformation process. The scatter caused by this source is inherent and then this form of the scatter is called internal distribution. Obviously the experimental distribution of material parameters combines these two distributions in some way; therefore, it is a sum distribution of the external distribution and the internal distribution. In view of this , a general method used to analyse the influence of the experimental errors on the experimental results is presented, and three criteria used to value this influence are defined. An example in which the fracture toughness KIC is analysed shows that this method is reasonable, convenient and effective. 展开更多
关键词 A METHOD OF ESTIMATING THE INFLUENCE OF experimental errorS ON THE experimental RESULTS OF MATERIAL PARAMETERS AND THE CRITERIA TO VALUE THIS INFLUENCE
下载PDF
A novel method of evaluating the lift force on the bluff body based on Noca's flux equation
2
作者 隋相坤 姜楠 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第8期426-430,共5页
The influence of experimental error on lift force evaluated by Noca’s flux equation is studied based on adding errors into the direct numerical simulation data for flow past cylinder at Re = 100. As Noca suggested us... The influence of experimental error on lift force evaluated by Noca’s flux equation is studied based on adding errors into the direct numerical simulation data for flow past cylinder at Re = 100. As Noca suggested using the low-pass filter to get rid of the high-frequency noise in the evaluated lift force, we verify that his method is inapplicable for dealing with the dataset of 1% experimental error, although the precision is acceptable in practice. To overcome this defect, a novel method is proposed in this paper. The average of the lift forces calculated by using multiple control volume is taken as the evaluation before applying the low-pass filter. The method is applied to an experimental data for flow past a cylinder at approximately Re = 900 to verify its validation. The results show that it improves much better on evaluating the lift forces. 展开更多
关键词 flux equation lift force experimental error
下载PDF
Optimizing the use of open chambers to measure ammonia volatilization in field plots amended with urea 被引量:1
3
作者 Márcio R.MARTINS Leonardo F.SARKIS +9 位作者 Selenobaldo A.C.SANT’ANNA Camila A.SANTOS Karla E.ARAUJO Ricardo C.SANTOS Ednaldo S.ARAÚJO Bruno J.R.ALVES Claudia P.JANTALIA Robert M.BODDEY Mohammad ZAMAN Segundo URQUIAGA 《Pedosphere》 SCIE CAS CSCD 2021年第2期243-254,共12页
Measuring ammonia(NH_(3))volatilization from urea-fertilized soils is crucial for evaluation of practices that reduce gaseous nitrogen(N)losses in agriculture.The small area of chambers used for NH_(3)volatilization m... Measuring ammonia(NH_(3))volatilization from urea-fertilized soils is crucial for evaluation of practices that reduce gaseous nitrogen(N)losses in agriculture.The small area of chambers used for NH_(3)volatilization measurements compared with the size of field plots may cause significant errors if inadequate sampling strategies are adopted.Our aims were:i)to investigate the effect of using multiple open chambers on the variability in the measurement of NH_(3)volatilization in urea-amended field plots and ii)to define the critical period of NH_(3)-N losses during which the concentration of sampling effort is capable of reducing uncertainty.The use of only one chamber covering 0.015%of the plot(51.84 m^(2))generates a value of NH_(3)-N loss within an expected margin of error of 30%around the true mean.To reduce the error margin by half(15%),3–7 chambers were required with a mean of 5 chambers per plot.Concentrating the sampling efforts in the first two weeks after urea application,which is usually the most critical period of N losses and associated errors,represents an efficient strategy to lessen uncertainty in the measurements of NH_(3)volatilization.This strategy enhances the power of detection of NH_(3)-N loss abatement in field experiments using chambers. 展开更多
关键词 chamber method experimental error gas emission low-cost chamber nitrogen cycling nitrogen loss soil variability
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部