Objective To evaluate the clinical effects of Ilizarov external fixator for maluninon of obsolete calcaneal fracture of Stephen Type Ⅲ.Methods From July 2006 to February 2009,25 patients suffering from maluninon of o...Objective To evaluate the clinical effects of Ilizarov external fixator for maluninon of obsolete calcaneal fracture of Stephen Type Ⅲ.Methods From July 2006 to February 2009,25 patients suffering from maluninon of obsolete calcaneal展开更多
BACKGROUND Reconstruction of the pelvic ring anatomy in unstable anterior pelvic ring injuries is a significant step to reduce the mortality rate associated with these injuries efficiently.There is a debate on using e...BACKGROUND Reconstruction of the pelvic ring anatomy in unstable anterior pelvic ring injuries is a significant step to reduce the mortality rate associated with these injuries efficiently.There is a debate on using either an anterior subcutaneous pelvis internal fixator(INFIX)or an anterior supra-acetabular external fixator(EXFIX)to manage an unstable anterior pelvic ring fracture.AIM To compare the functional and radiological outcomes and complications of INFIX vs EXFIX in managing unstable pelvic ring injuries.METHODS A prospective cohort study included 54 patients with unstable pelvic ring fractures.The patients were divided into two groups;the INFIX group,in which 30 cases were fixed by INFIX,and the EXFIX group,in which 24 patients were treated by EXFIX.The average age in the EXFIX group was 31.17 years(16-57 years),while in the INFIX group,it was 34.5 years(17-53 years).The study included 20(66.7%)males and 10(33.3%)females in the INFIX group and 10(41.7%)males and 14(58.3%)females in the EXFIX group.The radiological outcomes were evaluated using Matta and Tornetta's score,and the functional outcomes using the Majeed score.RESULTS The results revealed a statistically significant difference between both groups(P=0.013)regarding radiological outcomes,according to Matta and Tornetta's score in favor of the INFIX group.Sitting,standing,and walking abilities were measured at a 3-mo follow-up visit using Majeed score modules.It was significantly better among the INFIX group than the EXFIX group in all three modules.At the final follow-up,both groups had no statistically significant difference according to the Majeed score;92.35 in the INFIX group and 90.99 in the EXFIX group(P=0.513).A lower surgical site infection rate was noticed in the INFIX group(P=0.007).CONCLUSION Anterior subcutaneous pelvis INFIX is associated with better radiological outcomes and a lower infection rate than anterior supra-acetabular EXFIX in managing patients with unstable anterior pelvic ring fractures.展开更多
BACKGROUND Current research lacks a model of knee extension contracture in rats.AIM To elucidate the formation process of knee extension contracture.METHODS We developed a rat model using an aluminum external fixator....BACKGROUND Current research lacks a model of knee extension contracture in rats.AIM To elucidate the formation process of knee extension contracture.METHODS We developed a rat model using an aluminum external fixator.Sixty male Sprague-Dawley rats with mature bones were divided into the control group(n=6)and groups that had the left knee immobilized with an aluminum external fixator for 1,2,and 3 d,and 1,2,3,4,6,and 8 wk(n=6 in each group).The passive extension range of motion,histology,and expression of fibrosis-related proteins were compared between the control group and the immobilization groups.RESULTS Myogenic contracture progressed very quickly during the initial 2 wk of immobilization.After 2 wk,the contracture gradually changed from myogenic to arthrogenic.The arthrogenic contracture progressed slowly during the 1^(st) week,rapidly progressed until the 3^(rd) week,and then showed a steady progression until the 4^(rd) week.Histological analyses confirmed that the anterior joint capsule of the extended fixed knee became increasingly thicker over time.Correspondingly,the level of transforming growth factor beta 1(TGF-β1)and phosphorylated mothers against decapentaplegic homolog 2(p-Smad2)in the anterior joint capsule also increased with the immobilization time.Over time,the cross-sectional area of muscle fibers gradually decreased,while the amount of intermuscular collagen and TGF-β1,p-Smad2,and p-Smad3 was increased.Unexpectedly,the amount of intermuscular collagen and TGF-β1,p-Smad2,and p-Smad3 was decreased during the late stage of immobilization(6-8 wk).The myogenic contracture was stabilized after 2 wk of immobilization,whereas the arthrogenic contracture was stabilized after 3 wk of immobilization and completely stable in 4 wk.CONCLUSION This rat model may be a useful tool to study the etiology of joint contracture and establish therapeutic approaches.展开更多
Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The ...Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority.展开更多
Background:The Taylor Spatial Frame(TSF)has gained popularity among orthopedic surgeons for treating open fractures.However,a key challenge is the timely and safe removal of the frame.This study assessed the efficacy ...Background:The Taylor Spatial Frame(TSF)has gained popularity among orthopedic surgeons for treating open fractures.However,a key challenge is the timely and safe removal of the frame.This study assessed the efficacy and safety of axial load-share ratio(ALSR)testing to evaluate callus healing strength after TSF treatment of open tibial fractures.Methods:A retrospective case-control study was conducted,analyzing 180 adult patients with open tibial fractures treated at Tianjin Hospital’s Orthopedic Limb Correction Unit between August 2019 and August 2022.All patients underwent TSF external fixation surgery,and were divided into two groups based on ALSR testing.Group I(92 patients)underwent ALSR testing,with frame removal if the test value fell below 5%.Traditional methods were used for fixator removal guidance in Group II(88 patients).Clinical outcomes,including fixation duration,complications after fixator removal,and Johner-Wruhs functional scores,were compared between the two groups.Results:The groups showed no statistically significant differences(P>0.05)in sex,age,injury side,body mass index,surgery timing,or fracture type.Group I had a significantly shorter fixation duration(25.85±5.57 weeks)compared to Group II(31.82±6.98 weeks)(P<0.05).Following fixator removal,Group I demonstrated superior Johner-Wruhs scores compared to Group II,indicating better outcomes(P<0.05).Complication rates did not differ significantly between the groups at the last follow-up(P>0.05).Conclusion:Regular postoperative ALSR testing could safely and effectively guide TSF removal following open tibial fracture treatment.This method significantly reduced fixation duration compared to traditional guidance methods while maintaining efficacy and safety.展开更多
Introduction: Fractures of the distal end of the humerus are becoming increasingly frequent in young subjects because of the increase in road traffic accidents, and in elderly subjects because of osteoporosis related ...Introduction: Fractures of the distal end of the humerus are becoming increasingly frequent in young subjects because of the increase in road traffic accidents, and in elderly subjects because of osteoporosis related to aging populations. Materials and Methods: It was a prospective, monocentric study from January 2018 to December 2020 involving 14 patients who received and were treated surgically for distal humeral fractures and followed up. Results: We collected 14 patients, including 11 men (78.57%) and 3 women (21.43%), with a sex ratio of 3.7. The mean age was 36.41 years. The circumstances of onset were dominated by road traffic accidents, with 12 cases (85.71%). The dominant side was right-handed, with 11 cases (78.57%). Standard elbow radiography revealed 8 cases of type A fractures (57.14%), 4 cases of type B and 2 cases of type C fractures of the AO. We performed Lecestre plate osteosynthesis in 12 patients and external fixator in 2 others, using the trans-olecranial and transtricipital approaches. Elbow stiffness was the most frequent complication, with 6 cases (42.86%). After six months’ follow-up, our results were excellent and good in 78.57% of cases (MEPS). Conclusion: Surgical treatment with posterior approaches enabled us to achieve restitution of the articular surfaces, solid restraint and early mobilization of the elbow with satisfactory functional results.展开更多
BACKGROUND Pelvic fractures(PF)with concomitant injuries are on the rise due to an increase of high-energy trauma.Increase of the elderly population with age related comorbidities further complicates the management.Ab...BACKGROUND Pelvic fractures(PF)with concomitant injuries are on the rise due to an increase of high-energy trauma.Increase of the elderly population with age related comorbidities further complicates the management.Abdominal organ injuries are kindred with PF due to the proximity to pelvic bones.Presence of contrast blush(CB)on computed tomography in patients with PF is considered a sign of active bleeding,however,its clinical significance and association with outcomes is debatable.AIM To analyze polytrauma patients with PF with a focus on the geriatric population,co-injuries and the value of contrast blush.METHODS This retrospective cohort study included 558 patients with PF admitted to level 1 trauma center(01/2017-01/2023).Analyzed variables included:Age,sex,mechanism of injury(MOI),injury severity score(ISS),Glasgow coma scale(GCS),abbreviated injury scale(AIS),co-injuries,transfusion requirements,pelvic angiography,embolization,laparotomy,orthopedic pelvic surgery,intensive care unit and hospital lengths of stay,discharge disposition and mortality.The study compared geriatric and non-geriatric patients,patients with and without CB and abdominal co-injuries.Propensity score matching was implemented in comparison groups.RESULTS PF comprised 4%of all trauma admissions.89 patients had CB.286(52%)patients had concomitant injuries including 93(17%)patients with abdominal co-injuries.Geriatric patients compared to non-geriatric had more falls as MOI,lower ISS and AIS pelvis,higher GCS,less abdominal co-injuries,similar CB and angio-embolization rates,less orthopedic pelvic surgeries,shorter lengths of stay and higher mortality.After propensity matching,orthopedic pelvic surgery rates remained lower(8%vs 19%,P<0.001),hospital length of stay shorter,and mortality higher(13%vs 4%,P<0.001)in geriatric patients.Out of 89 patients with CB,45(51%)were embolized.After propensity matching,patients with CB compared to without CB had more pelvic angiography(71%vs 12%,P<0.001),higher embolization rates(64%vs 22%,P=0.02)and comparable mortality.CONCLUSION Half of the patients with PF had concomitant co-injuries,including abdominal co-injuries in 17%.Similarly injured geriatric patients had higher mortality.Half of the patients with CB required an embolization.展开更多
The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters fol...The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters following treatment of intra-articular fractures of the distal radius (IFDR) in patients older than 65 years. We hypothesized that using volar or dorsal plating would improve functional outcomes, but that it would be associated with more complications and equivalent functional outcomes when compared with the external fixation group. A total of 123 consecutive patients suffering from IFDR were recruited into the study. The patients were measured for clinical, radiological, and psychosocial functioning outcomes and were followed up after I week and 3, 6 and 12 months. After 3 months, the plating group had better pronation (P = 0.001), supination, (P = 0.047) and extension (P = 0.043) scores. These differences were somewhat attenuated by 6 months and disappeared at I year. The plating group had a greater occurrence of wound infection (P = 0.043), tendonitis, (P = 0.024) and additional surgery compared with the external fixation group. The only TNO-AZL Adult Quality of Life scores in the plating group that were lower than those in the external fixation group were in the "gross motor" category (walking upstairs, bending over, walking 500 yards; P = 0.023). Internal fixation was more advantageous than external fixation in the early rehabilitation period; after I year the outcomes were similar. The plating group showed significantly higher levels of wound infection and tendonitis and had a greater need for additional surgeries.展开更多
BACKGROUND Infection at the pin tract is a frequent and feared complication of external fixators(EF).The type of pin material and coatings have been regarded as possibly influencing infection rates.Over the last 20 ye...BACKGROUND Infection at the pin tract is a frequent and feared complication of external fixators(EF).The type of pin material and coatings have been regarded as possibly influencing infection rates.Over the last 20 years,few prospective clinical studies and systematic reviews addressed the role of coated pins on the rate of pin site infection in human clinical studies.AIM To assess the EF literature over the past 20 years on the clinical benefits of pins manufactured from varied materials and coating systems and their possible role in pin tract infection rates.METHODS We performed a systematic review according to the PRISMA and PICOS guidelines using four scientific platforms:PubMed,LiLacs,SciELO,and Cochrane.We searched the literature for related publications over the past 20 years.RESULTS A literature search yielded 29 articles,among which seven met the inclusion criteria.These studies compared stainless-steel pins and pins coated with hydroxyapatite(HA),titanium and silver.The pin tract infection definitions were arbitrary and not standardized among studies.Most studies included a low number of patients in the analysis and used a short follow-up time.Three metaanalyses were carried out,comparing stainless steel vs silver pins,stainless steel vs HA-coated pins,and titanium vs HA-coated pins.None of this analysis resulted in statistically significant differences in pin tract infection rates.CONCLUSION Currently,no clinical evidence supports the advantage of EF pins manufactured with materials other than stainless steel or coated over uncoated pins in reducing the rates of pin tract infections.A standardized definition of pin tract infection in external fixation is still lacking.展开更多
BACKGROUND Different external skeletal fixators have been widely used in preoperative traction of high-energy tibial fractures prior to a definitive surgical treatment.However,the early complications associated with t...BACKGROUND Different external skeletal fixators have been widely used in preoperative traction of high-energy tibial fractures prior to a definitive surgical treatment.However,the early complications associated with this staged treatment for traction and soft tissue injury recovery have rarely been discussed.AIM To analyze the early complications associated with preoperative external traction fixation in the staged treatment of tibial fractures.METHODS A total of 402 patients with high-energy tibial fractures treated using preoperative external traction fixation at a Level 1 trauma center from 2014 to 2018 were enrolled in this retrospective study.Data regarding the demographic information,Tscherne soft tissue injury,fracture site,entry point placement,and duration of traction were recorded.Procedure-related complications such as movement and sensation disorder,vessel injury,discharge,infection,loosening,and iatrogenic fractures were analyzed.RESULTS The mean patient age was 42.5(18-71)years,and the mean duration of traction was 7.5(0-26)d.In total,19(4.7%)patients presented with procedure-related complications,including technique-associated complications in 6 patients and nursing-associated complications in 13.Differences in the incidence of complications with respect to sex,affected side,soft tissue injury classification,and fracture sites were not observed.However,the number of complications due to hammer insertion was significantly reduced than those due to drill insertions(2.9%vs 7.4%).CONCLUSION We found a low incidence of early complications related to the fixation.Furthermore,the complications were not significantly associated with the severity of the soft tissue injury and fracture site.Although relatively rough and more likely to cause pain,the number of complications associated with hammer insertion was significantly smaller than that of complications associated with drill insertion.展开更多
Six tibias removed from 30-40 years old males, who died in an accident for in less than 12 hours, were osteotomized at one-third supra-medium segment. They were fixed by an unilateral adjustable external fixer (UAEF),...Six tibias removed from 30-40 years old males, who died in an accident for in less than 12 hours, were osteotomized at one-third supra-medium segment. They were fixed by an unilateral adjustable external fixer (UAEF), to be used as a model of external fixation of tibial fracture (MEFTF). The compression. tension, torsion, antero-posterior and lateral bending strength, and the strength for vertically extracting the pins from the tibia were determined in the MEFTF. Within a certain range of load, the correlation of strain to stress was basically a linear relationship. These data provide a theoretical basis of biomechanics for the improvement of UAEF and for early exercises of fracture patients, such as extend-bending of the joint.raising the limb and walking with a walking stick.展开更多
BACKGROUND High tibial osteotomy(HTO)is a well-known procedure for the correction of knee varus.The purpose of this study was to compare the radiological results and accuracy of deformity correction performed using tw...BACKGROUND High tibial osteotomy(HTO)is a well-known procedure for the correction of knee varus.The purpose of this study was to compare the radiological results and accuracy of deformity correction performed using two different techniques:acute opening wedge correction using a plate and gradual correction with a monolateral external fixator.AIM To compare of the radiological results of two different techniques:acute opening wedge correction(a plate and screw)and gradual correction(external fixator).METHODS A total of 43 patients with plates and 36 patients with external fixators were included.All patients had moderate uniplanar varus deformities.We measured radiographic parameters,including the mechanical axis deviation(MAD),medial proximal tibial angle(MPTA),Caton-Deschamps Index(CDI),posterior proximal tibial angle,and joint line obliquity angle(JLOA).The accuracy of MAD correction was calculated based on a correction goal of neutral or overcorrection for medial compartment arthritis.RESULTS Demographics including age,body mass index,sex,and preoperative deformities were similar between the groups.The MAD significantly improved from 23.6 mm medial to the midline(SD=8.2 mm)to 6.9 mm lateral to the midline(SD=5.4 mm)(P<0.001).The accuracy of MAD correction did not differ between the groups and was 96.1%(SD=8.1%)in the plate group and 98.2%(SD=5.2%)in the external fixator group(P=0.18).The MPTA significantly improved from 83.9°(SD=2.9°)to 90.9°(SD=3.3°)(P<0.001),and the change was similar between the groups.Differences were noted in patella height,with a CDI change of-19.2%(SD=13.7%)and 3.1%(SD=8.0%)for the plate and external fixator groups,respectively(P<0.001).The change in JLOA was 1.6 degrees(SD=1.1 degrees)and 0.9 degrees(SD=0.9 degrees)for the plate and external fixator groups,respectively(P=0.04).CONCLUSION Reliable correction of moderate varus alignment was achieved with both the acute opening wedge technique with a plate and the gradual monolateral external fixator technique.The patellar height decreased with the open wedge plate technique.Joint line obliquity decreased to a greater degree with the open wedge plate technique,perhaps as a result of medial collateral ligament release.The appropriate technique should be selected based on surgeon and patient preferences;however,external fixation may be a better choice when the preservation of patellar height is deemed important.展开更多
Objective: Unicameral bone cyst is a nonneoplasticbone lesion characterized by its tenacity and risk ofrecurrence. Pathological fracture is common and is often the presenting symptom. The objective of the present stud...Objective: Unicameral bone cyst is a nonneoplasticbone lesion characterized by its tenacity and risk ofrecurrence. Pathological fracture is common and is often the presenting symptom. The objective of the present study was to evaluate the results of hybrid external fixator for thetreatment of a unicameral bone cyst with a pathologicalfracture. Methods: Hybrid external fixator for thetreatment of a unicameral bone cyst was performed intwelve patients. These patients presented with a pathological fracture and were managed immediately with hybridexternal fixator, of whom four had been managedconservatively at other clinics before they were referred toour department. The cyst was located in the proximalhumerus in all patients. The mean age of the patients at the time of surgery was 8.7 years, and the mean duration offollow-up was 32.6 months. Radiographic evaluation wasperformed according to the criteria of Capanna et al., andthe cyst was classified as completely healed, healed withresidual radiolucency (osteolysis), recurred, or having noresponse. Results: The healing period ranged from three to eight months. Eight cysts healed completely, and threehealed with residual radiolucent areas visible onradiographs. There was recurrence of one cyst that hadhealed with residual radiolucency. All of the cysts in thepresent study responded to treatment. A modulation ofhybrid external fixator was necessary in three patients, asthe bars had become too short after bone growth or the pins had been loose. No major complications were observed.Conclusion: Hybrid external fixator provides earlystability, which allows early mobilization and thus obviates the need for a plaster cast. This method of treatment alsoallows for an early return to normal activity.展开更多
Four tibiae removed from 30-40 years males, who died of accidents in less than 12 hours, were os- teomized at medium part. Then these tibiae were fixed by an unilateral hooked-sulcated external fixator (UHSEF), and th...Four tibiae removed from 30-40 years males, who died of accidents in less than 12 hours, were os- teomized at medium part. Then these tibiae were fixed by an unilateral hooked-sulcated external fixator (UHSEF), and the bone-fixator system was used as a model of external fixation of tibial fracture. The axial compression, distraction, torsion, antero-posterior and lateral bending rigidly and the strain of the pins were determined in this system. Based on the results, we found that compared with the configuration of four paralled pins, the rigidity of the fan-like configuraton didn’t decrease significantly if the angle between lateral and medium pins was less than 45’. But the reverse was true when the frame separation increased from 5 to 8 cm. What’ more, the pin strain decreased if the rigidity of the system was improved. These data provided a theoretical basis of biomechanics for the improvement of UHSEF.展开更多
Five fresh tibias removed from 30-40 years old dead males were osteotomized at one-third supra-medium segment and then fixed by an unilateral adjustable external fixator (UAEF) to be used as a model of external fixati...Five fresh tibias removed from 30-40 years old dead males were osteotomized at one-third supra-medium segment and then fixed by an unilateral adjustable external fixator (UAEF) to be used as a model of external fixation of tibial fracture. For each loading test under different configurations of UAEF, the ratio of the force-displacement was used to determine its stiffness value. The weakest mode of the UAEF device is in AP bending. Under each mode of compression,distraction , anteroposterial and lateral bending and torsion loading , increasing the pin number or pin diameter or pin separation, and/or reduction of pin group separation can significantly increase the stiffness values of UAEF (P<0.01). These data revealed that UAEF is suitable for the external fixation of tibial fracture.展开更多
Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic...Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic outcomes of comminuted intra-articular DRFs treated with a dynamic external fixator combined with a volar locking plate (VLP). Methods: Eleven patients (mean age, 61 years) with comminuted intra-articular DRFs were treated with a dynamic type of external fixator combined with a VLP. Following reduction and fixation with a VLP, the dynamic external fixator was applied and the distal ball joint of the fixator was aligned with the lunate-capitate line. The ball joint was unlocked approximately 2 weeks after surgery to allow wrist mobilization. The fixator was removed 3 - 6 weeks (mean, 5 weeks) after surgery. Consequently, clinical and radiographic assessments were carried out at the final follow-up. Results: At the final follow-up, the mean range values of wrist extension and flexion were 76°and 64°, respectively. Compared with the contralateral side, the mean grip strength was 84%. The mean Modified Mayo Wrist Score and the Disabilities of the Arm, Shoulder and Hand score were 88 and 9, respectively. No significant differences in the radiographic parameters exist between after surgery and final follow-up. Conclusions: This study indicated that the dynamic wrist fixator combined with a VLP is effective for the treatment of AO type C3 DRFs.展开更多
A stress analysis of the Sarafix external fixator design was performed using finite element analysis (FEA) and experimental tensometric measurements. The study was conducted at one of the Sarafix fixator configurati...A stress analysis of the Sarafix external fixator design was performed using finite element analysis (FEA) and experimental tensometric measurements. The study was conducted at one of the Sarafix fixator configurations that have a clinical application in the treatment of tibia fractures. The intensity of principal and yon Mises stresses generated at two measuring points (MP) on the fixator connecting rod were monitored and analyzed during the testing on axial compression on the fixator design and its finite element model (FEM). The 3D geometrical and FEM model of the fixator was formed using the computer aided design/computer aided engineering (CAD/CAE) software system CATIA. Verification of the results for the dominant principal stresses obtained from FEA was carried out through tensometric measurements. The measuring chain consisted of strain gauges connected into two Wheatstone half-bridges, digital measuring amplifier system and a computer with software for acquisition and monitoring of measurement results. A quite good agreement was observed between the results obtained on the basis of FEA and results of experimental tensometric analysis,展开更多
Objective To evaluate effects of manipulative reduction,dynamic external fixator combined with limited internal fixation for the treatment of Pilon fractures.Methods From January 2007 to June 2009,manipulative reducti...Objective To evaluate effects of manipulative reduction,dynamic external fixator combined with limited internal fixation for the treatment of Pilon fractures.Methods From January 2007 to June 2009,manipulative reduction,dynamic external展开更多
Objective To evaluate the clinical outcomes of external fixator with lumbopelvic distraction spondylodesis in treatment of vertically unstable pelvic fractures.Methods From January 2008 to March 2009,9 patients(4 male...Objective To evaluate the clinical outcomes of external fixator with lumbopelvic distraction spondylodesis in treatment of vertically unstable pelvic fractures.Methods From January 2008 to March 2009,9 patients(4 males and 5 females)展开更多
BACKGROUND Ankylosing spondylitis(AS)is a chronic rheumatic disease that primarily affects the spine and the sacroiliac and peripheral joints.Juvenile-onset AS(JoAS)patients will likely present with peripheral joint s...BACKGROUND Ankylosing spondylitis(AS)is a chronic rheumatic disease that primarily affects the spine and the sacroiliac and peripheral joints.Juvenile-onset AS(JoAS)patients will likely present with peripheral joint symptoms.Knee flexion contracture(KFC)and hip flexion contracture(HFC)are common in these patients due to subchondral bone inflammation.The Ilizarov technique is the most commonly used technique for treating KFC.However,its use to treat JoAS-associated KFC has not been reported.CASE SUMMARY This report presents a case study of a 31-year-old male patient with a squatting gait due to severe bilateral KFC and HFC.The patient had a normal walking pattern until the age of eight,after which he experienced knee and hip pain,leading to the gradual development of KFC and HFC.The patient’s primary complaint was an inability to walk upright.The patient was diagnosed with JoAS and under-went hip dissection and release,limited soft tissue release of the hamstring,and gradual traction using the Ilizarov method.Ultimately,the patient was able to walk upright.CONCLUSION The incidence of squatting gait due to KFC in individuals diagnosed with JoAS was low.Utilizing the Ilizarov technique has proven to be a secure and effective method for managing KFC in JoAS patients.Although the Ilizarov technique cannot substitute for total knee arthroplasty(TKA),its application can delay the need for primary TKA in JoAS patients and alleviate the intricacy and potential complications associated with the procedure.展开更多
文摘Objective To evaluate the clinical effects of Ilizarov external fixator for maluninon of obsolete calcaneal fracture of Stephen Type Ⅲ.Methods From July 2006 to February 2009,25 patients suffering from maluninon of obsolete calcaneal
文摘BACKGROUND Reconstruction of the pelvic ring anatomy in unstable anterior pelvic ring injuries is a significant step to reduce the mortality rate associated with these injuries efficiently.There is a debate on using either an anterior subcutaneous pelvis internal fixator(INFIX)or an anterior supra-acetabular external fixator(EXFIX)to manage an unstable anterior pelvic ring fracture.AIM To compare the functional and radiological outcomes and complications of INFIX vs EXFIX in managing unstable pelvic ring injuries.METHODS A prospective cohort study included 54 patients with unstable pelvic ring fractures.The patients were divided into two groups;the INFIX group,in which 30 cases were fixed by INFIX,and the EXFIX group,in which 24 patients were treated by EXFIX.The average age in the EXFIX group was 31.17 years(16-57 years),while in the INFIX group,it was 34.5 years(17-53 years).The study included 20(66.7%)males and 10(33.3%)females in the INFIX group and 10(41.7%)males and 14(58.3%)females in the EXFIX group.The radiological outcomes were evaluated using Matta and Tornetta's score,and the functional outcomes using the Majeed score.RESULTS The results revealed a statistically significant difference between both groups(P=0.013)regarding radiological outcomes,according to Matta and Tornetta's score in favor of the INFIX group.Sitting,standing,and walking abilities were measured at a 3-mo follow-up visit using Majeed score modules.It was significantly better among the INFIX group than the EXFIX group in all three modules.At the final follow-up,both groups had no statistically significant difference according to the Majeed score;92.35 in the INFIX group and 90.99 in the EXFIX group(P=0.513).A lower surgical site infection rate was noticed in the INFIX group(P=0.007).CONCLUSION Anterior subcutaneous pelvis INFIX is associated with better radiological outcomes and a lower infection rate than anterior supra-acetabular EXFIX in managing patients with unstable anterior pelvic ring fractures.
基金Supported by Anhui Key Research and Development Program-Population Health,No.201904a07020067Anhui Provincial Health Research Project,No.AHWJ2022b063+2 种基金Clinical Medicine Discipline Construction Project of Anhui Medical University in 2022(Clinic and Preliminary Co-Construction Discipline Project),No.2022 lcxkEFY0102022 National Natural Science Foundation Incubation Plan,No.2022GMFY05Clinical Medicine Discipline Construction Project of Anhui Medical University in 2022(High-Level Personnel Training Program),No.2022 lcxkEFY04,No.2022 lcxkEFY05.
文摘BACKGROUND Current research lacks a model of knee extension contracture in rats.AIM To elucidate the formation process of knee extension contracture.METHODS We developed a rat model using an aluminum external fixator.Sixty male Sprague-Dawley rats with mature bones were divided into the control group(n=6)and groups that had the left knee immobilized with an aluminum external fixator for 1,2,and 3 d,and 1,2,3,4,6,and 8 wk(n=6 in each group).The passive extension range of motion,histology,and expression of fibrosis-related proteins were compared between the control group and the immobilization groups.RESULTS Myogenic contracture progressed very quickly during the initial 2 wk of immobilization.After 2 wk,the contracture gradually changed from myogenic to arthrogenic.The arthrogenic contracture progressed slowly during the 1^(st) week,rapidly progressed until the 3^(rd) week,and then showed a steady progression until the 4^(rd) week.Histological analyses confirmed that the anterior joint capsule of the extended fixed knee became increasingly thicker over time.Correspondingly,the level of transforming growth factor beta 1(TGF-β1)and phosphorylated mothers against decapentaplegic homolog 2(p-Smad2)in the anterior joint capsule also increased with the immobilization time.Over time,the cross-sectional area of muscle fibers gradually decreased,while the amount of intermuscular collagen and TGF-β1,p-Smad2,and p-Smad3 was increased.Unexpectedly,the amount of intermuscular collagen and TGF-β1,p-Smad2,and p-Smad3 was decreased during the late stage of immobilization(6-8 wk).The myogenic contracture was stabilized after 2 wk of immobilization,whereas the arthrogenic contracture was stabilized after 3 wk of immobilization and completely stable in 4 wk.CONCLUSION This rat model may be a useful tool to study the etiology of joint contracture and establish therapeutic approaches.
基金2022 Key Specialty Construction Project of Traditional Chinese Medicine:Traditional Chinese Orthopedics and Traumatology Department (No.962042)2020 Regional Traditional Chinese Medicine (Orthopedics and Traumatology)Diagnosis and Treatment Center (Jin Wei Zhong[2020]No.5)。
文摘Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority.
基金funding support from Natural Science Foundation Key Project of Tianjin(20JCZDJC00600)Tianjin Health Research Project(TJWJ2023QN050)+2 种基金Applied Basic Research Foundation of Tianjin(22JCQNJC00230,22JCQNJC00360)Beijing-Tianjin-Hebei Basic Research Cooperation Project(J230007/23JCZXJC00050)Tianjin Municipal Health Commission Key Discipline Specialization(TJWJ2024XK015).
文摘Background:The Taylor Spatial Frame(TSF)has gained popularity among orthopedic surgeons for treating open fractures.However,a key challenge is the timely and safe removal of the frame.This study assessed the efficacy and safety of axial load-share ratio(ALSR)testing to evaluate callus healing strength after TSF treatment of open tibial fractures.Methods:A retrospective case-control study was conducted,analyzing 180 adult patients with open tibial fractures treated at Tianjin Hospital’s Orthopedic Limb Correction Unit between August 2019 and August 2022.All patients underwent TSF external fixation surgery,and were divided into two groups based on ALSR testing.Group I(92 patients)underwent ALSR testing,with frame removal if the test value fell below 5%.Traditional methods were used for fixator removal guidance in Group II(88 patients).Clinical outcomes,including fixation duration,complications after fixator removal,and Johner-Wruhs functional scores,were compared between the two groups.Results:The groups showed no statistically significant differences(P>0.05)in sex,age,injury side,body mass index,surgery timing,or fracture type.Group I had a significantly shorter fixation duration(25.85±5.57 weeks)compared to Group II(31.82±6.98 weeks)(P<0.05).Following fixator removal,Group I demonstrated superior Johner-Wruhs scores compared to Group II,indicating better outcomes(P<0.05).Complication rates did not differ significantly between the groups at the last follow-up(P>0.05).Conclusion:Regular postoperative ALSR testing could safely and effectively guide TSF removal following open tibial fracture treatment.This method significantly reduced fixation duration compared to traditional guidance methods while maintaining efficacy and safety.
文摘Introduction: Fractures of the distal end of the humerus are becoming increasingly frequent in young subjects because of the increase in road traffic accidents, and in elderly subjects because of osteoporosis related to aging populations. Materials and Methods: It was a prospective, monocentric study from January 2018 to December 2020 involving 14 patients who received and were treated surgically for distal humeral fractures and followed up. Results: We collected 14 patients, including 11 men (78.57%) and 3 women (21.43%), with a sex ratio of 3.7. The mean age was 36.41 years. The circumstances of onset were dominated by road traffic accidents, with 12 cases (85.71%). The dominant side was right-handed, with 11 cases (78.57%). Standard elbow radiography revealed 8 cases of type A fractures (57.14%), 4 cases of type B and 2 cases of type C fractures of the AO. We performed Lecestre plate osteosynthesis in 12 patients and external fixator in 2 others, using the trans-olecranial and transtricipital approaches. Elbow stiffness was the most frequent complication, with 6 cases (42.86%). After six months’ follow-up, our results were excellent and good in 78.57% of cases (MEPS). Conclusion: Surgical treatment with posterior approaches enabled us to achieve restitution of the articular surfaces, solid restraint and early mobilization of the elbow with satisfactory functional results.
文摘BACKGROUND Pelvic fractures(PF)with concomitant injuries are on the rise due to an increase of high-energy trauma.Increase of the elderly population with age related comorbidities further complicates the management.Abdominal organ injuries are kindred with PF due to the proximity to pelvic bones.Presence of contrast blush(CB)on computed tomography in patients with PF is considered a sign of active bleeding,however,its clinical significance and association with outcomes is debatable.AIM To analyze polytrauma patients with PF with a focus on the geriatric population,co-injuries and the value of contrast blush.METHODS This retrospective cohort study included 558 patients with PF admitted to level 1 trauma center(01/2017-01/2023).Analyzed variables included:Age,sex,mechanism of injury(MOI),injury severity score(ISS),Glasgow coma scale(GCS),abbreviated injury scale(AIS),co-injuries,transfusion requirements,pelvic angiography,embolization,laparotomy,orthopedic pelvic surgery,intensive care unit and hospital lengths of stay,discharge disposition and mortality.The study compared geriatric and non-geriatric patients,patients with and without CB and abdominal co-injuries.Propensity score matching was implemented in comparison groups.RESULTS PF comprised 4%of all trauma admissions.89 patients had CB.286(52%)patients had concomitant injuries including 93(17%)patients with abdominal co-injuries.Geriatric patients compared to non-geriatric had more falls as MOI,lower ISS and AIS pelvis,higher GCS,less abdominal co-injuries,similar CB and angio-embolization rates,less orthopedic pelvic surgeries,shorter lengths of stay and higher mortality.After propensity matching,orthopedic pelvic surgery rates remained lower(8%vs 19%,P<0.001),hospital length of stay shorter,and mortality higher(13%vs 4%,P<0.001)in geriatric patients.Out of 89 patients with CB,45(51%)were embolized.After propensity matching,patients with CB compared to without CB had more pelvic angiography(71%vs 12%,P<0.001),higher embolization rates(64%vs 22%,P=0.02)and comparable mortality.CONCLUSION Half of the patients with PF had concomitant co-injuries,including abdominal co-injuries in 17%.Similarly injured geriatric patients had higher mortality.Half of the patients with CB required an embolization.
基金supported by National Natural Science Foundation of China Grant 81560350
文摘The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters following treatment of intra-articular fractures of the distal radius (IFDR) in patients older than 65 years. We hypothesized that using volar or dorsal plating would improve functional outcomes, but that it would be associated with more complications and equivalent functional outcomes when compared with the external fixation group. A total of 123 consecutive patients suffering from IFDR were recruited into the study. The patients were measured for clinical, radiological, and psychosocial functioning outcomes and were followed up after I week and 3, 6 and 12 months. After 3 months, the plating group had better pronation (P = 0.001), supination, (P = 0.047) and extension (P = 0.043) scores. These differences were somewhat attenuated by 6 months and disappeared at I year. The plating group had a greater occurrence of wound infection (P = 0.043), tendonitis, (P = 0.024) and additional surgery compared with the external fixation group. The only TNO-AZL Adult Quality of Life scores in the plating group that were lower than those in the external fixation group were in the "gross motor" category (walking upstairs, bending over, walking 500 yards; P = 0.023). Internal fixation was more advantageous than external fixation in the early rehabilitation period; after I year the outcomes were similar. The plating group showed significantly higher levels of wound infection and tendonitis and had a greater need for additional surgeries.
文摘BACKGROUND Infection at the pin tract is a frequent and feared complication of external fixators(EF).The type of pin material and coatings have been regarded as possibly influencing infection rates.Over the last 20 years,few prospective clinical studies and systematic reviews addressed the role of coated pins on the rate of pin site infection in human clinical studies.AIM To assess the EF literature over the past 20 years on the clinical benefits of pins manufactured from varied materials and coating systems and their possible role in pin tract infection rates.METHODS We performed a systematic review according to the PRISMA and PICOS guidelines using four scientific platforms:PubMed,LiLacs,SciELO,and Cochrane.We searched the literature for related publications over the past 20 years.RESULTS A literature search yielded 29 articles,among which seven met the inclusion criteria.These studies compared stainless-steel pins and pins coated with hydroxyapatite(HA),titanium and silver.The pin tract infection definitions were arbitrary and not standardized among studies.Most studies included a low number of patients in the analysis and used a short follow-up time.Three metaanalyses were carried out,comparing stainless steel vs silver pins,stainless steel vs HA-coated pins,and titanium vs HA-coated pins.None of this analysis resulted in statistically significant differences in pin tract infection rates.CONCLUSION Currently,no clinical evidence supports the advantage of EF pins manufactured with materials other than stainless steel or coated over uncoated pins in reducing the rates of pin tract infections.A standardized definition of pin tract infection in external fixation is still lacking.
文摘BACKGROUND Different external skeletal fixators have been widely used in preoperative traction of high-energy tibial fractures prior to a definitive surgical treatment.However,the early complications associated with this staged treatment for traction and soft tissue injury recovery have rarely been discussed.AIM To analyze the early complications associated with preoperative external traction fixation in the staged treatment of tibial fractures.METHODS A total of 402 patients with high-energy tibial fractures treated using preoperative external traction fixation at a Level 1 trauma center from 2014 to 2018 were enrolled in this retrospective study.Data regarding the demographic information,Tscherne soft tissue injury,fracture site,entry point placement,and duration of traction were recorded.Procedure-related complications such as movement and sensation disorder,vessel injury,discharge,infection,loosening,and iatrogenic fractures were analyzed.RESULTS The mean patient age was 42.5(18-71)years,and the mean duration of traction was 7.5(0-26)d.In total,19(4.7%)patients presented with procedure-related complications,including technique-associated complications in 6 patients and nursing-associated complications in 13.Differences in the incidence of complications with respect to sex,affected side,soft tissue injury classification,and fracture sites were not observed.However,the number of complications due to hammer insertion was significantly reduced than those due to drill insertions(2.9%vs 7.4%).CONCLUSION We found a low incidence of early complications related to the fixation.Furthermore,the complications were not significantly associated with the severity of the soft tissue injury and fracture site.Although relatively rough and more likely to cause pain,the number of complications associated with hammer insertion was significantly smaller than that of complications associated with drill insertion.
文摘Six tibias removed from 30-40 years old males, who died in an accident for in less than 12 hours, were osteotomized at one-third supra-medium segment. They were fixed by an unilateral adjustable external fixer (UAEF), to be used as a model of external fixation of tibial fracture (MEFTF). The compression. tension, torsion, antero-posterior and lateral bending strength, and the strength for vertically extracting the pins from the tibia were determined in the MEFTF. Within a certain range of load, the correlation of strain to stress was basically a linear relationship. These data provide a theoretical basis of biomechanics for the improvement of UAEF and for early exercises of fracture patients, such as extend-bending of the joint.raising the limb and walking with a walking stick.
文摘BACKGROUND High tibial osteotomy(HTO)is a well-known procedure for the correction of knee varus.The purpose of this study was to compare the radiological results and accuracy of deformity correction performed using two different techniques:acute opening wedge correction using a plate and gradual correction with a monolateral external fixator.AIM To compare of the radiological results of two different techniques:acute opening wedge correction(a plate and screw)and gradual correction(external fixator).METHODS A total of 43 patients with plates and 36 patients with external fixators were included.All patients had moderate uniplanar varus deformities.We measured radiographic parameters,including the mechanical axis deviation(MAD),medial proximal tibial angle(MPTA),Caton-Deschamps Index(CDI),posterior proximal tibial angle,and joint line obliquity angle(JLOA).The accuracy of MAD correction was calculated based on a correction goal of neutral or overcorrection for medial compartment arthritis.RESULTS Demographics including age,body mass index,sex,and preoperative deformities were similar between the groups.The MAD significantly improved from 23.6 mm medial to the midline(SD=8.2 mm)to 6.9 mm lateral to the midline(SD=5.4 mm)(P<0.001).The accuracy of MAD correction did not differ between the groups and was 96.1%(SD=8.1%)in the plate group and 98.2%(SD=5.2%)in the external fixator group(P=0.18).The MPTA significantly improved from 83.9°(SD=2.9°)to 90.9°(SD=3.3°)(P<0.001),and the change was similar between the groups.Differences were noted in patella height,with a CDI change of-19.2%(SD=13.7%)and 3.1%(SD=8.0%)for the plate and external fixator groups,respectively(P<0.001).The change in JLOA was 1.6 degrees(SD=1.1 degrees)and 0.9 degrees(SD=0.9 degrees)for the plate and external fixator groups,respectively(P=0.04).CONCLUSION Reliable correction of moderate varus alignment was achieved with both the acute opening wedge technique with a plate and the gradual monolateral external fixator technique.The patellar height decreased with the open wedge plate technique.Joint line obliquity decreased to a greater degree with the open wedge plate technique,perhaps as a result of medial collateral ligament release.The appropriate technique should be selected based on surgeon and patient preferences;however,external fixation may be a better choice when the preservation of patellar height is deemed important.
文摘Objective: Unicameral bone cyst is a nonneoplasticbone lesion characterized by its tenacity and risk ofrecurrence. Pathological fracture is common and is often the presenting symptom. The objective of the present study was to evaluate the results of hybrid external fixator for thetreatment of a unicameral bone cyst with a pathologicalfracture. Methods: Hybrid external fixator for thetreatment of a unicameral bone cyst was performed intwelve patients. These patients presented with a pathological fracture and were managed immediately with hybridexternal fixator, of whom four had been managedconservatively at other clinics before they were referred toour department. The cyst was located in the proximalhumerus in all patients. The mean age of the patients at the time of surgery was 8.7 years, and the mean duration offollow-up was 32.6 months. Radiographic evaluation wasperformed according to the criteria of Capanna et al., andthe cyst was classified as completely healed, healed withresidual radiolucency (osteolysis), recurred, or having noresponse. Results: The healing period ranged from three to eight months. Eight cysts healed completely, and threehealed with residual radiolucent areas visible onradiographs. There was recurrence of one cyst that hadhealed with residual radiolucency. All of the cysts in thepresent study responded to treatment. A modulation ofhybrid external fixator was necessary in three patients, asthe bars had become too short after bone growth or the pins had been loose. No major complications were observed.Conclusion: Hybrid external fixator provides earlystability, which allows early mobilization and thus obviates the need for a plaster cast. This method of treatment alsoallows for an early return to normal activity.
基金This work was supported by Wuhan science & Technolgy Committee
文摘Four tibiae removed from 30-40 years males, who died of accidents in less than 12 hours, were os- teomized at medium part. Then these tibiae were fixed by an unilateral hooked-sulcated external fixator (UHSEF), and the bone-fixator system was used as a model of external fixation of tibial fracture. The axial compression, distraction, torsion, antero-posterior and lateral bending rigidly and the strain of the pins were determined in this system. Based on the results, we found that compared with the configuration of four paralled pins, the rigidity of the fan-like configuraton didn’t decrease significantly if the angle between lateral and medium pins was less than 45’. But the reverse was true when the frame separation increased from 5 to 8 cm. What’ more, the pin strain decreased if the rigidity of the system was improved. These data provided a theoretical basis of biomechanics for the improvement of UHSEF.
文摘Five fresh tibias removed from 30-40 years old dead males were osteotomized at one-third supra-medium segment and then fixed by an unilateral adjustable external fixator (UAEF) to be used as a model of external fixation of tibial fracture. For each loading test under different configurations of UAEF, the ratio of the force-displacement was used to determine its stiffness value. The weakest mode of the UAEF device is in AP bending. Under each mode of compression,distraction , anteroposterial and lateral bending and torsion loading , increasing the pin number or pin diameter or pin separation, and/or reduction of pin group separation can significantly increase the stiffness values of UAEF (P<0.01). These data revealed that UAEF is suitable for the external fixation of tibial fracture.
文摘Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic outcomes of comminuted intra-articular DRFs treated with a dynamic external fixator combined with a volar locking plate (VLP). Methods: Eleven patients (mean age, 61 years) with comminuted intra-articular DRFs were treated with a dynamic type of external fixator combined with a VLP. Following reduction and fixation with a VLP, the dynamic external fixator was applied and the distal ball joint of the fixator was aligned with the lunate-capitate line. The ball joint was unlocked approximately 2 weeks after surgery to allow wrist mobilization. The fixator was removed 3 - 6 weeks (mean, 5 weeks) after surgery. Consequently, clinical and radiographic assessments were carried out at the final follow-up. Results: At the final follow-up, the mean range values of wrist extension and flexion were 76°and 64°, respectively. Compared with the contralateral side, the mean grip strength was 84%. The mean Modified Mayo Wrist Score and the Disabilities of the Arm, Shoulder and Hand score were 88 and 9, respectively. No significant differences in the radiographic parameters exist between after surgery and final follow-up. Conclusions: This study indicated that the dynamic wrist fixator combined with a VLP is effective for the treatment of AO type C3 DRFs.
文摘A stress analysis of the Sarafix external fixator design was performed using finite element analysis (FEA) and experimental tensometric measurements. The study was conducted at one of the Sarafix fixator configurations that have a clinical application in the treatment of tibia fractures. The intensity of principal and yon Mises stresses generated at two measuring points (MP) on the fixator connecting rod were monitored and analyzed during the testing on axial compression on the fixator design and its finite element model (FEM). The 3D geometrical and FEM model of the fixator was formed using the computer aided design/computer aided engineering (CAD/CAE) software system CATIA. Verification of the results for the dominant principal stresses obtained from FEA was carried out through tensometric measurements. The measuring chain consisted of strain gauges connected into two Wheatstone half-bridges, digital measuring amplifier system and a computer with software for acquisition and monitoring of measurement results. A quite good agreement was observed between the results obtained on the basis of FEA and results of experimental tensometric analysis,
文摘Objective To evaluate effects of manipulative reduction,dynamic external fixator combined with limited internal fixation for the treatment of Pilon fractures.Methods From January 2007 to June 2009,manipulative reduction,dynamic external
文摘Objective To evaluate the clinical outcomes of external fixator with lumbopelvic distraction spondylodesis in treatment of vertically unstable pelvic fractures.Methods From January 2008 to March 2009,9 patients(4 males and 5 females)
文摘BACKGROUND Ankylosing spondylitis(AS)is a chronic rheumatic disease that primarily affects the spine and the sacroiliac and peripheral joints.Juvenile-onset AS(JoAS)patients will likely present with peripheral joint symptoms.Knee flexion contracture(KFC)and hip flexion contracture(HFC)are common in these patients due to subchondral bone inflammation.The Ilizarov technique is the most commonly used technique for treating KFC.However,its use to treat JoAS-associated KFC has not been reported.CASE SUMMARY This report presents a case study of a 31-year-old male patient with a squatting gait due to severe bilateral KFC and HFC.The patient had a normal walking pattern until the age of eight,after which he experienced knee and hip pain,leading to the gradual development of KFC and HFC.The patient’s primary complaint was an inability to walk upright.The patient was diagnosed with JoAS and under-went hip dissection and release,limited soft tissue release of the hamstring,and gradual traction using the Ilizarov method.Ultimately,the patient was able to walk upright.CONCLUSION The incidence of squatting gait due to KFC in individuals diagnosed with JoAS was low.Utilizing the Ilizarov technique has proven to be a secure and effective method for managing KFC in JoAS patients.Although the Ilizarov technique cannot substitute for total knee arthroplasty(TKA),its application can delay the need for primary TKA in JoAS patients and alleviate the intricacy and potential complications associated with the procedure.