The fiber Fabry-Perot interferometer used to measure the refractive index modulation of polymer-dispersed liquid crystal is introduced.From measuring the quantity of the interference fringe shift with a CCD based on t...The fiber Fabry-Perot interferometer used to measure the refractive index modulation of polymer-dispersed liquid crystal is introduced.From measuring the quantity of the interference fringe shift with a CCD based on the theory of isoclinal interference fringes formatting,the maximal refractive index modulation versus different external voltages,3.899×10-3 in the external voltage of 57.4 V/μm,and the dynamic refractive index modulation versus response time in the external voltage of 8 V/μm are found in our prepared 1.250 mm-thick PMMA/E49/TNF/ECZ polymer-dispersed liquid crystals.The experimental results will be helpful to understand the photoinduced reaction mechanism of the material and optimize the mixture ratio of each component.展开更多
We investigated the sensitivities of atom interferometers in the usual fringe-scanning method (FSM) versus the fringe- locking method (FLM). The theoretical analysis shows that for typical noises in atom interfero...We investigated the sensitivities of atom interferometers in the usual fringe-scanning method (FSM) versus the fringe- locking method (FLM). The theoretical analysis shows that for typical noises in atom interferometers, the FSM will degrade the sensitivity while the FLM does not. The sensitivity-improvement factor of the FLM over the FSM depends on the type of noises, which is validated by numerical simulations. The detailed quantitative analysis on this fundamental issue is presented, and our analysis is readily extendable to other kinds of noises as well as other fringe shapes in addition to a cosine one.展开更多
A cirele scanning method is Proposed to measare surface roughness with a heterodyne interferometer. Pa-rameter Rz can be meased with an uncertainty of less than 6nm.
文摘The fiber Fabry-Perot interferometer used to measure the refractive index modulation of polymer-dispersed liquid crystal is introduced.From measuring the quantity of the interference fringe shift with a CCD based on the theory of isoclinal interference fringes formatting,the maximal refractive index modulation versus different external voltages,3.899×10-3 in the external voltage of 57.4 V/μm,and the dynamic refractive index modulation versus response time in the external voltage of 8 V/μm are found in our prepared 1.250 mm-thick PMMA/E49/TNF/ECZ polymer-dispersed liquid crystals.The experimental results will be helpful to understand the photoinduced reaction mechanism of the material and optimize the mixture ratio of each component.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.41127002,11574099,41504034,and 11474115)the National Basic Research Program of China(Grant No.2010CB832806)
文摘We investigated the sensitivities of atom interferometers in the usual fringe-scanning method (FSM) versus the fringe- locking method (FLM). The theoretical analysis shows that for typical noises in atom interferometers, the FSM will degrade the sensitivity while the FLM does not. The sensitivity-improvement factor of the FLM over the FSM depends on the type of noises, which is validated by numerical simulations. The detailed quantitative analysis on this fundamental issue is presented, and our analysis is readily extendable to other kinds of noises as well as other fringe shapes in addition to a cosine one.
文摘A cirele scanning method is Proposed to measare surface roughness with a heterodyne interferometer. Pa-rameter Rz can be meased with an uncertainty of less than 6nm.