A simple and sensitive solid phase extraction utilizing C18 filled cartridges incorporated with dithizone for preconcentration of lead and its subsequent determination by flame atomic absorption spectrometry (FAAS) wa...A simple and sensitive solid phase extraction utilizing C18 filled cartridges incorporated with dithizone for preconcentration of lead and its subsequent determination by flame atomic absorption spectrometry (FAAS) was developed. Several parameters such as type, concentration and volume of eluent, pH of the sample solution, flow rate of extraction and volume of the sample were evaluated. The effect of a variety of ions on preconcentration and recovery was also investigated. At pH = 7.4 and 1.0 mol?L–1 HCl eluting them, lead ions were recovered quantitatively. The limit of detection (LOD) defined as 3Sbl was determined to be 8.1 μg L–1 for 500 mL of sample solution and eluted with 5 mL of 1.0 mol?L–1 HCl under optimum conditions. The accuracy and precision (RSD %) of the method were >90% and <10%, respectively. In the end, the proposed method was applied to a number of real sugar samples and the amount of lead was determined by spiking a known concentration of lead into the solution.展开更多
A method for determining calcium(Ca),potassium(K),magnesium(Mg) and iron(Fe) in four fish species was optimized and validated.It included microwave mineralization of the samples and subsequent quantification by flame ...A method for determining calcium(Ca),potassium(K),magnesium(Mg) and iron(Fe) in four fish species was optimized and validated.It included microwave mineralization of the samples and subsequent quantification by flame atomic absorption spectroscopy(FAAS) with Zeeman-effect background correction.Using HNO3(65%) and H2O2(33%) as extraction solutions,the optimal conditions of extraction were established as follows:0.5 g of sample mass;microwave time program of 300 W/5 min and 600 W/5 min.The method was free of matrix interferences.The linear correlation coefficients were ≥0.9991,the recovery percentage of analytes was from 99.31% to 103.70% and the RSD(relative standard deviation) was lower than 2.06%.The detection limits obtained were 32.3,43.2,14.0 and 68.6 ng mL-1 for Ca,K,Mg and Fe in FAAS respectively.It is shown that the method is rapid,simple,sensitive and accurate.The method was applied to the studies of digestibility and measurement of these nutrients in samples of fish collected from Norway,Japan and China.展开更多
文摘A simple and sensitive solid phase extraction utilizing C18 filled cartridges incorporated with dithizone for preconcentration of lead and its subsequent determination by flame atomic absorption spectrometry (FAAS) was developed. Several parameters such as type, concentration and volume of eluent, pH of the sample solution, flow rate of extraction and volume of the sample were evaluated. The effect of a variety of ions on preconcentration and recovery was also investigated. At pH = 7.4 and 1.0 mol?L–1 HCl eluting them, lead ions were recovered quantitatively. The limit of detection (LOD) defined as 3Sbl was determined to be 8.1 μg L–1 for 500 mL of sample solution and eluted with 5 mL of 1.0 mol?L–1 HCl under optimum conditions. The accuracy and precision (RSD %) of the method were >90% and <10%, respectively. In the end, the proposed method was applied to a number of real sugar samples and the amount of lead was determined by spiking a known concentration of lead into the solution.
文摘A method for determining calcium(Ca),potassium(K),magnesium(Mg) and iron(Fe) in four fish species was optimized and validated.It included microwave mineralization of the samples and subsequent quantification by flame atomic absorption spectroscopy(FAAS) with Zeeman-effect background correction.Using HNO3(65%) and H2O2(33%) as extraction solutions,the optimal conditions of extraction were established as follows:0.5 g of sample mass;microwave time program of 300 W/5 min and 600 W/5 min.The method was free of matrix interferences.The linear correlation coefficients were ≥0.9991,the recovery percentage of analytes was from 99.31% to 103.70% and the RSD(relative standard deviation) was lower than 2.06%.The detection limits obtained were 32.3,43.2,14.0 and 68.6 ng mL-1 for Ca,K,Mg and Fe in FAAS respectively.It is shown that the method is rapid,simple,sensitive and accurate.The method was applied to the studies of digestibility and measurement of these nutrients in samples of fish collected from Norway,Japan and China.