An accurate estimation of the applied load pattern is an essential component in each pushover procedure. Recently, a number of adaptive pushover methods have been proposed in which the effects of the higher modes as w...An accurate estimation of the applied load pattern is an essential component in each pushover procedure. Recently, a number of adaptive pushover methods have been proposed in which the effects of the higher modes as well as the progressive changes in the dynamic characteristics of structures are taken into account to compute the applied load pattern. The basic shortcoming of these advanced pushover methods is related to employing the quadratic modal combination rule, whereby the sign reversals of the modal load vectors are suppressed. In this study, an improved displacement-based adaptive pushover method is developed in which the applied load pattern is computed using the factor modal combination rule(FMC). In the proposed procedure, multiple load patterns, depending on the number of the modes considered, are determined in order to take into account the sign reversals of different modal load vectors. The accuracy of the proposed method is verifi ed for seven moment resisting frame buildings of 3, 9 and 20 stories with regularity or vertically geometric and mass irregularities subjected to 60 earthquake ground motion records. The results showed that the proposed methodology is capable of reproducing the peak dynamic responses with very good accuracy.展开更多
Seismic bearing capacity factors of a strip footing placed on soil slope were determined with both associated and nonassociated flow rules. Quasi-static representation of earthquake effects using a seismic coefficient...Seismic bearing capacity factors of a strip footing placed on soil slope were determined with both associated and nonassociated flow rules. Quasi-static representation of earthquake effects using a seismic coefficient concept was adopted for seismic bearing capacity calculations. A multi-wedge translational failure mechanism was used to obtain the seismic bearing capacity factors for different seismic coefficients and various inclined angles. Employing the associated flow rule, numerical results were compared with the published solutions. For bearing capacity factors related to cohesion and equivalent surcharge load, the maximum difference approximates 0.1%. However, the difference of bearing capacity factor related to unit weight is larger. With the two flow rules, the seismic bearing capacity factors were presented in the form of design charts for practical use. The results show that seismic bearing capacity factors related to the cohesion, the equivalent surcharge load and the unit weight increase greatly as the dilatancy angle increases, and that the nonassociated flow rule has important influences on the seismic bearing capacity.展开更多
文摘An accurate estimation of the applied load pattern is an essential component in each pushover procedure. Recently, a number of adaptive pushover methods have been proposed in which the effects of the higher modes as well as the progressive changes in the dynamic characteristics of structures are taken into account to compute the applied load pattern. The basic shortcoming of these advanced pushover methods is related to employing the quadratic modal combination rule, whereby the sign reversals of the modal load vectors are suppressed. In this study, an improved displacement-based adaptive pushover method is developed in which the applied load pattern is computed using the factor modal combination rule(FMC). In the proposed procedure, multiple load patterns, depending on the number of the modes considered, are determined in order to take into account the sign reversals of different modal load vectors. The accuracy of the proposed method is verifi ed for seven moment resisting frame buildings of 3, 9 and 20 stories with regularity or vertically geometric and mass irregularities subjected to 60 earthquake ground motion records. The results showed that the proposed methodology is capable of reproducing the peak dynamic responses with very good accuracy.
基金Project(200550) supported by the Foundation for the Author of National Excellent Doctoral Dissertation of ChinaProject(05-0686) supported by the Program for New Century Excellent Talents in University
文摘Seismic bearing capacity factors of a strip footing placed on soil slope were determined with both associated and nonassociated flow rules. Quasi-static representation of earthquake effects using a seismic coefficient concept was adopted for seismic bearing capacity calculations. A multi-wedge translational failure mechanism was used to obtain the seismic bearing capacity factors for different seismic coefficients and various inclined angles. Employing the associated flow rule, numerical results were compared with the published solutions. For bearing capacity factors related to cohesion and equivalent surcharge load, the maximum difference approximates 0.1%. However, the difference of bearing capacity factor related to unit weight is larger. With the two flow rules, the seismic bearing capacity factors were presented in the form of design charts for practical use. The results show that seismic bearing capacity factors related to the cohesion, the equivalent surcharge load and the unit weight increase greatly as the dilatancy angle increases, and that the nonassociated flow rule has important influences on the seismic bearing capacity.