According to the process features and the reaction mechanism of FDFCC technology, its two reaction subsystems, one for heavy oil riser reactor, the other for gasoline riser reactor, were respec-tively studied. Corresp...According to the process features and the reaction mechanism of FDFCC technology, its two reaction subsystems, one for heavy oil riser reactor, the other for gasoline riser reactor, were respec-tively studied. Correspondingly, a 12-lump kinetic model for heavy oil FCC and a 9-lump kinetic model for gasoline catalytic upgrading were presented. Based on this work, mathematical correlation of the lumps in the feeds and products involved in the reaction subsystems and those of the overall reaction system were analyzed in detail. Then, a combined kinetic model for FDFCC, which was based on the data recovered from a commercial unit, was put forward. The reaction performance embodied by the kinetic constants for the combined model of FDFCC was in accordance with catalytic cracking reaction mechanism. The model-calculated values were close to the data obtained in commercial scale. The model was easy to be applied in practice and could also provide some theoretical groundwork for further re-search on kinetic model for FDFCC.展开更多
文摘According to the process features and the reaction mechanism of FDFCC technology, its two reaction subsystems, one for heavy oil riser reactor, the other for gasoline riser reactor, were respec-tively studied. Correspondingly, a 12-lump kinetic model for heavy oil FCC and a 9-lump kinetic model for gasoline catalytic upgrading were presented. Based on this work, mathematical correlation of the lumps in the feeds and products involved in the reaction subsystems and those of the overall reaction system were analyzed in detail. Then, a combined kinetic model for FDFCC, which was based on the data recovered from a commercial unit, was put forward. The reaction performance embodied by the kinetic constants for the combined model of FDFCC was in accordance with catalytic cracking reaction mechanism. The model-calculated values were close to the data obtained in commercial scale. The model was easy to be applied in practice and could also provide some theoretical groundwork for further re-search on kinetic model for FDFCC.