A facility system can be modeled by a connected graph in which the vertices represent entities such as suppliers, distribution centers or customers and the edges represent facilities such as the paths of goods or info...A facility system can be modeled by a connected graph in which the vertices represent entities such as suppliers, distribution centers or customers and the edges represent facilities such as the paths of goods or information. The efficiency, and hence the reliability, of a facility system is to a large degree adversely affected by the edge failures in the network. Such failures may be caused by various natural disasters or terrorist attacks. In this paper, we consider facility systems’ reliability analysis based on the classical uncapacitated fixed-charge location problem when subject to edge failures. For an existing facility system, we formulate two models based on deterministic case and stochastic case to measure the loss in efficiency due to edge failures and give computational results and reliability envelopes for a specific example.展开更多
We view a facility system as a kind of supply chain and model it as a connected graph in which the nodes represent suppliers, distribution centers or customers and the edges represent the paths of goods or information...We view a facility system as a kind of supply chain and model it as a connected graph in which the nodes represent suppliers, distribution centers or customers and the edges represent the paths of goods or information. The efficiency, and hence the reliability, of a facility system is to a large degree adversely affected by the edge failures in the network. In this paper, we consider facility systems' reliability analysis based on the classical p-median problem when subject to edge failures. We formulate two models based on deterministic case and stochastic case to measure the loss in efficiency due to edge failures and give computational results and reliability envelopes for a specific example.展开更多
The reliability of facility location problem has aroused wide concern recently. Many researchers focus on reliable and robust facility systems design under component failures and have obtained promising performance. H...The reliability of facility location problem has aroused wide concern recently. Many researchers focus on reliable and robust facility systems design under component failures and have obtained promising performance. However, the target and reliability of a facility system are to a large degree adversely affected by the edge failures in the network, which remains a deep study. In this paper, we focus on facility systems’ reliability subject to edge failures. For a facility location system, we formulate two models based on classical uncapacitated fixed-charge location problem under deterministic and stochastic cases. For a specific example, location decisions and the comparison of reliability under different location models are given. Extensive experiments verify that significant improvements in reliability can be attained simply by increasing the amount of operating cost.展开更多
Deep-Litter System is a high yield approach to raise swine with pollution free in a lower cost. In the research, based on the heat stress in summer caused by fermentation, three temperature-control systems were design...Deep-Litter System is a high yield approach to raise swine with pollution free in a lower cost. In the research, based on the heat stress in summer caused by fermentation, three temperature-control systems were designed, including natural ventilation through transoms, forced ventilation via fans, and cooling by hyperbaric spray system. Specifically, the latter intermittent auto-pressurized spray system developed in our lab, which could spray successively via pressure from storage tubes without wetting the fermentation bed, is suitable for the promotion with the deep-litter technology in rural regions , since the power consumption is only 1 kwh per day.展开更多
Beam lifetime is dominated by Touschek scattering at the Shanghai Synchrotron Radiation Facility(SSRF).Touschek loss rate is affected by probability for scattering beyond the RF acceptance and the volume charge densit...Beam lifetime is dominated by Touschek scattering at the Shanghai Synchrotron Radiation Facility(SSRF).Touschek loss rate is affected by probability for scattering beyond the RF acceptance and the volume charge density of the bench.In the phaseⅡupgrade of the SSRF,a third harmonic superconducting cavity will be used to enhance the Touschek lifetime by lengthening the bunches.The Touschek lifetime improvement factor is affected by the voltage of a harmonic cavity.To stabilize the cavity voltage,a tuning control system was designed to control it.The design of the tuning control system was based on the SSRF third-generation low-level RF control system.Some hardware and specialized algorithms were redesigned to fit the harmonic cavity control.The design of the tuning control system is complete,and the control system has been tested.The test result shows that the fluctuation of amplitude is<±0.34%within 1.5 h,which satisfies the stability requirement.展开更多
The present building facility management status in China resulted in many problems such as high energy consumption,failure of automation control,services failure and poor indoor air quality.Based on questionnaires and...The present building facility management status in China resulted in many problems such as high energy consumption,failure of automation control,services failure and poor indoor air quality.Based on questionnaires and interviews to professional engineers and building users,a comprehensive evaluation index system was established on facility management of high-rise office buildings.A Fuzzy AHP based upon hierarchy criteria system was established.A Fuzzy AHP Evaluation Model on Facility Management System was set up;α-cut analysis was introduced and incorporated with expert knowledge together,which made up the optimism index λ.The fuzzy optimum crisp weight of each criterion was resulted from data-mining.Case investigations were processed in high-rise office buildings in Shenyang.The results illustrated that indoor air quality,thermal comfort and life cycle cost were the most important indexes in the evaluation of Facility Management System of high rise office buildings.Residents in high-rise buildings in Shenyang pay less attention to maintenance management and environment protection.By comparison with the analysis result of Export Choice,Fuzzy AHP-based evaluation model could act as a scientific reference for the establishment of governmental standards in facility management area in building.展开更多
An e-tag used on the freeway is a kind of passive sensors composed of sensors and radio- frequency identification (RFID) tags. The principle of the electronic toll collection system is that the sensor emits radio wa...An e-tag used on the freeway is a kind of passive sensors composed of sensors and radio- frequency identification (RFID) tags. The principle of the electronic toll collection system is that the sensor emits radio waves touching the e-tag within a certain range, the e-tag will respond to the radio waves by induction, and the sensor will read and write information of the vehicles. Although the RFID technology is popularly used in campus management systems, there is no e-tag technology application used in a campus parking system. In this paper, we use the e-tag technology on a campus parking management system based on the cloud-based construction. By this, it helps to achieve automated and standardized management of the campus parking system, enhance management efficiency, reduce the residence time of the vehicles at the entrances and exits, and improve the efficiency of vehicles parked at the same time.展开更多
The building information model/modeling (BIM) technology is currently applied in a broad range of applications and research for facility management, while the BIM-based mobile FM is difficult owing to various factor...The building information model/modeling (BIM) technology is currently applied in a broad range of applications and research for facility management, while the BIM-based mobile FM is difficult owing to various factors and environments. For example, the mobile applications usually require frequent cross-equipment compatibility. This paper proposes a reasonable BIM-based FM cross-platform framework and develops a mobile application on the basis of an existing BIM-based FM system. The developed mobile application is applied in a case study of a metro station project in Guangzhou to verify its effectiveness in FM practice. It helps maintenance staff in viewing BIMs, accessing related information, and updating maintenance records in a unique platform. The test results demonstrate that the proposed BIM-based cross-platform framework meet the FM application requirements and supports the extension of FM functions.展开更多
This paper proposes a novel three-dimensional(3D)isolation system for facilities and presents the numerical simulation approach for the isolated system under earthquake excitations and impact effect using the OpenSees...This paper proposes a novel three-dimensional(3D)isolation system for facilities and presents the numerical simulation approach for the isolated system under earthquake excitations and impact effect using the OpenSees(Open System for Earthquake Engineering Simulation)software frame work.The 3D isolators combine the quasi-zero stiffness(QZS)system in the vertical direction and lead rubber bearing in the horizontal direction.Considering the large aspect ratio of the isolated facility,linear viscous dampers are designed in the vertical direction to diminish the overturning effect.The vertical QZS isolation system is characterized by a cubic force-displacement relation,thus,no elements or materials can model this mechanic behavior in the existing finite element software.This study takes advantage of the open source feature of the OpenSees to create a new material to represent the mechanic properties of the QZS system.Then the user-defined material is combined with the rubber isolator element to model the 3D isolator.Considering different soil types and input magnitudes,six sets of natural seismic records and artificial waves and half sine pulses are selected as the input excitations.A finite element model for the 3D isolated facility is established based on the combined element and the simulation is performed to calculate the time history response.The numerical simulation reveals the flexibility of the OpenSees to deal with new engineering problems,and the results prove that the new 3D isolation system can have an optimal isolation effect in both horizontal and vertical directions.The maximum acceleration response at the top of the facility is below the target limit,and the maximum deformation and the overturning motion of the isolation system can be controlled in a safe range.展开更多
The reliability of facility location problems has been received wide attention for several decades. Researchers formulate varied models to optimize the reliability of location decisions. But the most of such studies a...The reliability of facility location problems has been received wide attention for several decades. Researchers formulate varied models to optimize the reliability of location decisions. But the most of such studies are not practical since the models are too ideal. In this paper, based on the classical uncapacitated fixed-charge location problem (UFLP) and some supply constraints from the reality, we distinguish deterministic facility failure and stochastic facility failure cases to formulate models to measure the reliability of a system. The computational results and reliability envelopes for a specific example are also given.展开更多
As a crucial economic crop in Guangxi region,chili pepper is facing increasingly severe challenges of continuous cropping obstacles.In this paper,the causes of continuous cropping obstacles in chili pepper soil are de...As a crucial economic crop in Guangxi region,chili pepper is facing increasingly severe challenges of continuous cropping obstacles.In this paper,the causes of continuous cropping obstacles in chili pepper soil are deeply analyzed,covering multiple dimensions such as the dynamic changes in soil physicochemical properties,the imbalance of soil microbial community structure,and the gradual accumulation of soil borne diseases and pests.Subsequently,a set of comprehensive prevention and control strategy is proposed:soil improvement through the application of organic fertilizers,biological fertilizers,and soil conditioners;implementing agricultural strategies of crop rotation and intercropping,flexibly adjusting planting density and methods,to optimize crop layout and improve planting management measures;actively introducing natural enemies for biological control,while promoting the use of biopesticides and microbial preparations for biological control.In response to the actual situation of continuous cropping obstacles in chili pepper soil of Guangxi,it is suggested that innovative soil improvement technologies,improved planting management measures,and promotion of biological control methods should also be considered.展开更多
According to the"National Modern Facility Agriculture Construction Plan(2023-2030)released by the Ministry of Agriculture and Rural Affairs,the"Special Implementation Plan for Modern Facility Fisheries Const...According to the"National Modern Facility Agriculture Construction Plan(2023-2030)released by the Ministry of Agriculture and Rural Affairs,the"Special Implementation Plan for Modern Facility Fisheries Construction"emphasizes the development of circular aquaculture,active expansion of green aquaculture space in facility fisheries,multi-channel development of food sources,comprehensive improvement of the quality,efficiency,and competitiveness of facility fisheries,ensuring stable and safe supply of aquatic products,and better meeting people's needs for high-quality aquatic products and beautiful aquatic ecological environment.Since the implementation of the 14th Five Year Plan for fisheries,facility fisheries have made significant progress.In order to thoroughly implement General Secretary Xi Jinping's important discourse on new quality productivity,conduct in-depth research on the current situation and existing problems of the fishery industry,and put forward suggestions to meet the requirements of high-quality development of the fishery industry in the new era.Therefore,it is crucial to continue practicing the"revitalization of aquatic seed industry"and"big food concept",take multiple measures to"demand food from rivers,lakes,and seas",and expand aquaculture space.Through research,it has been found that research in the field of facility based fisheries is still in its developmental stage.Further exploration is needed on the current status,breeding models,and experimental demonstrations of land-based facility based fisheries,in order to provide a basis for fisheries regulatory authorities to formulate the"15th Five Year Plan"for facility based fisheries.展开更多
[Objective] The aim was to establish a set of soilless cultivation and management method of facility strawberry cultivation in the south of China.[Method] In the research,strawberry species,substrate formulae,cultivat...[Objective] The aim was to establish a set of soilless cultivation and management method of facility strawberry cultivation in the south of China.[Method] In the research,strawberry species,substrate formulae,cultivation modes and nutri ent solutions were selected and optimized.[Result] Three-dimensional strawberry cultivation was much suitable for Frandy,Hongbao and Gumei No.1; substrate with coconut shred-mushroom residue-peat soil ratio at 2∶2∶1 was the optimal; the treatment C3,containing Ca(NO3)2·4H2O,KNO3,(NH4)2HPO4,MgSO4·7H2O,and NH4NO3 at 280,303,62,246 and 80 mg/L,promoted strawberry growth,and the cultivated strawberry was large and thick in leaves,thick in stem,dark green in leaf color,with best fruit yield and quality.Among three cultivation modes,the density,space use ratio and yield in the treatment with PVC pipes in A-shape were all higher and the strawberry was easier and more convenient for picking.[Conclusion] The research provides references for soilless cultivation of strawberry in the south of China.展开更多
First a remanufactming logistics network is con- structed, in which the structure of both the forward logistics and the reverse logistics are of two levels and all the logistics facilities are capacitated. Both the re...First a remanufactming logistics network is con- structed, in which the structure of both the forward logistics and the reverse logistics are of two levels and all the logistics facilities are capacitated. Both the remanufactming products and the new products can be used to meet the demands of customers. Moreover, it is assumed that homogeneous facilities can be designed together into integrated ones, based on which a mixed integer nonlinear programming (MINLP) facility location model of the remanufacturing logistics network with six types of facilities to be sited is built. Then an algorithm based on enumeration for the model is given. The feasible combinations of binary variables are searched by enumeration, and the remaining sub-problems are solved by the LP solver. Finally, the validities of the model and the algorithm are illustrated by means of an example. The result of the sensitivity analysis of parameters indicates that the integration of homogeneous facilities may influence the optimal solution of the problem to a certain degree.展开更多
The greenhouse has been increasingly used in the breeding industry. However, the high temperature inside the greenhouse in summer has not been effectively addressed. The spray cooling system sprays tiny droplets into ...The greenhouse has been increasingly used in the breeding industry. However, the high temperature inside the greenhouse in summer has not been effectively addressed. The spray cooling system sprays tiny droplets into the air. Thus the water molecules will be vaporized, absorbing heat and reducing ambient temperature. It is the only cooling method that can be used to cool the uneasily-sealed flexible greenhouse. We developed an energy-storing high pressure spray cooling system. The ordinary water pump is used as the source of high-pressure water. The partial kinetic energy is stored in the energy-storing tubes. When the water pump is stopped, the energy produced by releasing the compressed air can still be used to maintain the spray. And thus the use-cost and systematic wear would be reduced. The cooling system only requires 1 kilowatt hour of power per day. It has been widely used in summer to cool the breeding sheds. After a recent continuous improvement, its functions have been extended to disinfection, removing dust, humidifying and immunizing animals. In addition, it can also be used for the cooling and humidifying of squares, venues and streets in summer. The energy-storing high pressure spray cooling system has a broad application prospect.展开更多
Micro-turbine engine has no enough space for measuring impeller characteristics,so the design and the construction of a new test facility of micro-turbo-machinery are presented for micro-centrifugal compressors and ra...Micro-turbine engine has no enough space for measuring impeller characteristics,so the design and the construction of a new test facility of micro-turbo-machinery are presented for micro-centrifugal compressors and radial turbines.The facility is used for the full speed compressor test and the long duration hot turbine test.To rapidly adjust the testing condition,all regulations of the operating state are automatically completed by the control system.The facility is also used for testing the impeller performance with a series of diameter from 55 mm to 180 mm as a result of the modular design.A thermal protection system is designed to avoid the heat distortion caused by the high turbine inlet temperature over 1 100 K and provide a proper experimental environment for the electronic components.A photoelectric torque transducer with the accuracy of 1% is designed to measure the torque of rigid shaft at a high speed of 125 000 r/min.The designing techniques for micro-turbo-machineries are verified by the impeller testing of the facility.展开更多
To smooth the correlation process from bio-virus diffusion to emergency relief response,the Gaussian plume model is used to describe the diffusion of dangerous sources,where the bio-virus concentration at any given po...To smooth the correlation process from bio-virus diffusion to emergency relief response,the Gaussian plume model is used to describe the diffusion of dangerous sources,where the bio-virus concentration at any given point in affected areas can be calculated.And the toxic load rule is introduced to define the borderline of the dangerous area at different levels.Combined with this,different emergency levels of different demand points in dangerous areas are confirmed using fuzzy clustering,which allows demand points at the same emergency level to cluster in a group.Some effective emergency relief centers are chosen from the candidate hospitals which are located in different emergency level affected areas by set covering.Bioterrorism experiments which were conducted in Nanjing,Jiangsu province are simulated,and the results indicate that the novel method can be used efficiently by decision makers during an actual anti-bioterrorism relief.展开更多
With China's rapid development of the construction of modern campus,the school's increasing popularity and status as well as the growing number of foreign exchange.Current campus information,human development ...With China's rapid development of the construction of modern campus,the school's increasing popularity and status as well as the growing number of foreign exchange.Current campus information,human development has gradually become a new issue on the development and construction of schools.The article through the analyzing on design features of the modern Campus Sign System to meet the needs of different groups,and the information can be effective used through the modern Campus Sign System between peoples and campus.So that in their daily life,work and other needs are fully met.展开更多
The protein complex crystallographic beamline BL19U1 at the Shanghai Synchrotron Radiation Facility is one of the five beamlines dedicated to protein sciences operated by National Facility for Protein Science(Shanghai...The protein complex crystallographic beamline BL19U1 at the Shanghai Synchrotron Radiation Facility is one of the five beamlines dedicated to protein sciences operated by National Facility for Protein Science(Shanghai,China).The beamline,which features a small-gap invacuum undulator,has been officially open to users since March 2015.This beamline delivers X-ray in the energy range 7–15 keV.With its high flux,low divergence beam and a large active area detector,BL19U1 is designed for proteins with large molecular weight and large crystallographic unit cell dimensions.Good performance and stable operation of the beamline have allowed the number of Protein Data Bank(PDB)depositions and the number of articles published based on data collected at this beamline to increase steadily.To date,over 300 research groups have collected data at the beamline.More than 600 PDB entries have been deposited at the PDB(www.pdb.org).More than 300 papers have been published that include data collected at the beamline,including 21 research articles published in the top-level journals Cell,Nature,and Science.展开更多
Facility layout selection is a multi-criteria decision making (MCDM) problem,since it has a strategic impact on the efficiency of manufacturing system.In view of the interdependency among selection criteria,analytic n...Facility layout selection is a multi-criteria decision making (MCDM) problem,since it has a strategic impact on the efficiency of manufacturing system.In view of the interdependency among selection criteria,analytic network process (ANP) is proposed to analyze the structure of the facility layout selection problem and determine the weights for each criterion.A network structure is constructed that shows all elements and clusters and their interactions.Limit priorities are also calculated which help decision maker evaluate the relative importance among criterion in the alternative selection process.Moreover,a hybrid MCDM approach that employs ANP and technique for order preference by similarity to an ideal solution (TOPSIS)method to rank the optimal facility layout alternatives.Finally,an application of a new aeronautic component assembly workshop facility layout selection is conducted.To further illustrate the advantage of the proposed approach,the difference between ANP-TOPSIS and AHP-TOPSIS methods are compared and discussed.Results have demonstrated the effectiveness and feasibility of the proposed method.展开更多
文摘A facility system can be modeled by a connected graph in which the vertices represent entities such as suppliers, distribution centers or customers and the edges represent facilities such as the paths of goods or information. The efficiency, and hence the reliability, of a facility system is to a large degree adversely affected by the edge failures in the network. Such failures may be caused by various natural disasters or terrorist attacks. In this paper, we consider facility systems’ reliability analysis based on the classical uncapacitated fixed-charge location problem when subject to edge failures. For an existing facility system, we formulate two models based on deterministic case and stochastic case to measure the loss in efficiency due to edge failures and give computational results and reliability envelopes for a specific example.
文摘We view a facility system as a kind of supply chain and model it as a connected graph in which the nodes represent suppliers, distribution centers or customers and the edges represent the paths of goods or information. The efficiency, and hence the reliability, of a facility system is to a large degree adversely affected by the edge failures in the network. In this paper, we consider facility systems' reliability analysis based on the classical p-median problem when subject to edge failures. We formulate two models based on deterministic case and stochastic case to measure the loss in efficiency due to edge failures and give computational results and reliability envelopes for a specific example.
文摘The reliability of facility location problem has aroused wide concern recently. Many researchers focus on reliable and robust facility systems design under component failures and have obtained promising performance. However, the target and reliability of a facility system are to a large degree adversely affected by the edge failures in the network, which remains a deep study. In this paper, we focus on facility systems’ reliability subject to edge failures. For a facility location system, we formulate two models based on classical uncapacitated fixed-charge location problem under deterministic and stochastic cases. For a specific example, location decisions and the comparison of reliability under different location models are given. Extensive experiments verify that significant improvements in reliability can be attained simply by increasing the amount of operating cost.
基金Supported by the Agricultural Science and Technology Innovation Funds of Jiangsu(cx(12)1001-04)~~
文摘Deep-Litter System is a high yield approach to raise swine with pollution free in a lower cost. In the research, based on the heat stress in summer caused by fermentation, three temperature-control systems were designed, including natural ventilation through transoms, forced ventilation via fans, and cooling by hyperbaric spray system. Specifically, the latter intermittent auto-pressurized spray system developed in our lab, which could spray successively via pressure from storage tubes without wetting the fermentation bed, is suitable for the promotion with the deep-litter technology in rural regions , since the power consumption is only 1 kwh per day.
文摘Beam lifetime is dominated by Touschek scattering at the Shanghai Synchrotron Radiation Facility(SSRF).Touschek loss rate is affected by probability for scattering beyond the RF acceptance and the volume charge density of the bench.In the phaseⅡupgrade of the SSRF,a third harmonic superconducting cavity will be used to enhance the Touschek lifetime by lengthening the bunches.The Touschek lifetime improvement factor is affected by the voltage of a harmonic cavity.To stabilize the cavity voltage,a tuning control system was designed to control it.The design of the tuning control system was based on the SSRF third-generation low-level RF control system.Some hardware and specialized algorithms were redesigned to fit the harmonic cavity control.The design of the tuning control system is complete,and the control system has been tested.The test result shows that the fluctuation of amplitude is<±0.34%within 1.5 h,which satisfies the stability requirement.
文摘The present building facility management status in China resulted in many problems such as high energy consumption,failure of automation control,services failure and poor indoor air quality.Based on questionnaires and interviews to professional engineers and building users,a comprehensive evaluation index system was established on facility management of high-rise office buildings.A Fuzzy AHP based upon hierarchy criteria system was established.A Fuzzy AHP Evaluation Model on Facility Management System was set up;α-cut analysis was introduced and incorporated with expert knowledge together,which made up the optimism index λ.The fuzzy optimum crisp weight of each criterion was resulted from data-mining.Case investigations were processed in high-rise office buildings in Shenyang.The results illustrated that indoor air quality,thermal comfort and life cycle cost were the most important indexes in the evaluation of Facility Management System of high rise office buildings.Residents in high-rise buildings in Shenyang pay less attention to maintenance management and environment protection.By comparison with the analysis result of Export Choice,Fuzzy AHP-based evaluation model could act as a scientific reference for the establishment of governmental standards in facility management area in building.
文摘An e-tag used on the freeway is a kind of passive sensors composed of sensors and radio- frequency identification (RFID) tags. The principle of the electronic toll collection system is that the sensor emits radio waves touching the e-tag within a certain range, the e-tag will respond to the radio waves by induction, and the sensor will read and write information of the vehicles. Although the RFID technology is popularly used in campus management systems, there is no e-tag technology application used in a campus parking system. In this paper, we use the e-tag technology on a campus parking management system based on the cloud-based construction. By this, it helps to achieve automated and standardized management of the campus parking system, enhance management efficiency, reduce the residence time of the vehicles at the entrances and exits, and improve the efficiency of vehicles parked at the same time.
基金Supported by the National High-tech Research and Development Program of China(2013AA041307)the National Natural Science Foundation of China(51478249)the Tsinghua University-Glodon Joint Research Centre for Building Information Model
文摘The building information model/modeling (BIM) technology is currently applied in a broad range of applications and research for facility management, while the BIM-based mobile FM is difficult owing to various factors and environments. For example, the mobile applications usually require frequent cross-equipment compatibility. This paper proposes a reasonable BIM-based FM cross-platform framework and develops a mobile application on the basis of an existing BIM-based FM system. The developed mobile application is applied in a case study of a metro station project in Guangzhou to verify its effectiveness in FM practice. It helps maintenance staff in viewing BIMs, accessing related information, and updating maintenance records in a unique platform. The test results demonstrate that the proposed BIM-based cross-platform framework meet the FM application requirements and supports the extension of FM functions.
基金The authors acknowledge the financial support from National Natural Science Foundation of China(Grant No.51878502).
文摘This paper proposes a novel three-dimensional(3D)isolation system for facilities and presents the numerical simulation approach for the isolated system under earthquake excitations and impact effect using the OpenSees(Open System for Earthquake Engineering Simulation)software frame work.The 3D isolators combine the quasi-zero stiffness(QZS)system in the vertical direction and lead rubber bearing in the horizontal direction.Considering the large aspect ratio of the isolated facility,linear viscous dampers are designed in the vertical direction to diminish the overturning effect.The vertical QZS isolation system is characterized by a cubic force-displacement relation,thus,no elements or materials can model this mechanic behavior in the existing finite element software.This study takes advantage of the open source feature of the OpenSees to create a new material to represent the mechanic properties of the QZS system.Then the user-defined material is combined with the rubber isolator element to model the 3D isolator.Considering different soil types and input magnitudes,six sets of natural seismic records and artificial waves and half sine pulses are selected as the input excitations.A finite element model for the 3D isolated facility is established based on the combined element and the simulation is performed to calculate the time history response.The numerical simulation reveals the flexibility of the OpenSees to deal with new engineering problems,and the results prove that the new 3D isolation system can have an optimal isolation effect in both horizontal and vertical directions.The maximum acceleration response at the top of the facility is below the target limit,and the maximum deformation and the overturning motion of the isolation system can be controlled in a safe range.
文摘The reliability of facility location problems has been received wide attention for several decades. Researchers formulate varied models to optimize the reliability of location decisions. But the most of such studies are not practical since the models are too ideal. In this paper, based on the classical uncapacitated fixed-charge location problem (UFLP) and some supply constraints from the reality, we distinguish deterministic facility failure and stochastic facility failure cases to formulate models to measure the reliability of a system. The computational results and reliability envelopes for a specific example are also given.
文摘As a crucial economic crop in Guangxi region,chili pepper is facing increasingly severe challenges of continuous cropping obstacles.In this paper,the causes of continuous cropping obstacles in chili pepper soil are deeply analyzed,covering multiple dimensions such as the dynamic changes in soil physicochemical properties,the imbalance of soil microbial community structure,and the gradual accumulation of soil borne diseases and pests.Subsequently,a set of comprehensive prevention and control strategy is proposed:soil improvement through the application of organic fertilizers,biological fertilizers,and soil conditioners;implementing agricultural strategies of crop rotation and intercropping,flexibly adjusting planting density and methods,to optimize crop layout and improve planting management measures;actively introducing natural enemies for biological control,while promoting the use of biopesticides and microbial preparations for biological control.In response to the actual situation of continuous cropping obstacles in chili pepper soil of Guangxi,it is suggested that innovative soil improvement technologies,improved planting management measures,and promotion of biological control methods should also be considered.
基金supported by the National Bulk Freshwater Fish Industry Technology System(CARS-45-33)Tianjin Freshwater Aquaculture Industry Technology System Innovation Team(ITTFRS20211000-005/002)+2 种基金Tianjin Science and Technology Plan Project(23YDTPJC00420)Central Guiding Local Science and Technology Development Fund(24ZYCGSN00250)Open Fund of Key Laboratory of Environmental Standards and Environmental Pollution of the Ministry of Education(202007,202105).
文摘According to the"National Modern Facility Agriculture Construction Plan(2023-2030)released by the Ministry of Agriculture and Rural Affairs,the"Special Implementation Plan for Modern Facility Fisheries Construction"emphasizes the development of circular aquaculture,active expansion of green aquaculture space in facility fisheries,multi-channel development of food sources,comprehensive improvement of the quality,efficiency,and competitiveness of facility fisheries,ensuring stable and safe supply of aquatic products,and better meeting people's needs for high-quality aquatic products and beautiful aquatic ecological environment.Since the implementation of the 14th Five Year Plan for fisheries,facility fisheries have made significant progress.In order to thoroughly implement General Secretary Xi Jinping's important discourse on new quality productivity,conduct in-depth research on the current situation and existing problems of the fishery industry,and put forward suggestions to meet the requirements of high-quality development of the fishery industry in the new era.Therefore,it is crucial to continue practicing the"revitalization of aquatic seed industry"and"big food concept",take multiple measures to"demand food from rivers,lakes,and seas",and expand aquaculture space.Through research,it has been found that research in the field of facility based fisheries is still in its developmental stage.Further exploration is needed on the current status,breeding models,and experimental demonstrations of land-based facility based fisheries,in order to provide a basis for fisheries regulatory authorities to formulate the"15th Five Year Plan"for facility based fisheries.
基金Supported by National Natural Science Foundation of China(31101534)Youth Foundation of Tutorial System,Fujian Academy of Agricultural Sciences(2013DQB-8)~~
文摘[Objective] The aim was to establish a set of soilless cultivation and management method of facility strawberry cultivation in the south of China.[Method] In the research,strawberry species,substrate formulae,cultivation modes and nutri ent solutions were selected and optimized.[Result] Three-dimensional strawberry cultivation was much suitable for Frandy,Hongbao and Gumei No.1; substrate with coconut shred-mushroom residue-peat soil ratio at 2∶2∶1 was the optimal; the treatment C3,containing Ca(NO3)2·4H2O,KNO3,(NH4)2HPO4,MgSO4·7H2O,and NH4NO3 at 280,303,62,246 and 80 mg/L,promoted strawberry growth,and the cultivated strawberry was large and thick in leaves,thick in stem,dark green in leaf color,with best fruit yield and quality.Among three cultivation modes,the density,space use ratio and yield in the treatment with PVC pipes in A-shape were all higher and the strawberry was easier and more convenient for picking.[Conclusion] The research provides references for soilless cultivation of strawberry in the south of China.
基金The National Natural Science Foundation of China(No.70472033).
文摘First a remanufactming logistics network is con- structed, in which the structure of both the forward logistics and the reverse logistics are of two levels and all the logistics facilities are capacitated. Both the remanufactming products and the new products can be used to meet the demands of customers. Moreover, it is assumed that homogeneous facilities can be designed together into integrated ones, based on which a mixed integer nonlinear programming (MINLP) facility location model of the remanufacturing logistics network with six types of facilities to be sited is built. Then an algorithm based on enumeration for the model is given. The feasible combinations of binary variables are searched by enumeration, and the remaining sub-problems are solved by the LP solver. Finally, the validities of the model and the algorithm are illustrated by means of an example. The result of the sensitivity analysis of parameters indicates that the integration of homogeneous facilities may influence the optimal solution of the problem to a certain degree.
基金Supported by Jiangsu Agricultural Science and Technology Innovation Fund[CX(12)1001-04]~~
文摘The greenhouse has been increasingly used in the breeding industry. However, the high temperature inside the greenhouse in summer has not been effectively addressed. The spray cooling system sprays tiny droplets into the air. Thus the water molecules will be vaporized, absorbing heat and reducing ambient temperature. It is the only cooling method that can be used to cool the uneasily-sealed flexible greenhouse. We developed an energy-storing high pressure spray cooling system. The ordinary water pump is used as the source of high-pressure water. The partial kinetic energy is stored in the energy-storing tubes. When the water pump is stopped, the energy produced by releasing the compressed air can still be used to maintain the spray. And thus the use-cost and systematic wear would be reduced. The cooling system only requires 1 kilowatt hour of power per day. It has been widely used in summer to cool the breeding sheds. After a recent continuous improvement, its functions have been extended to disinfection, removing dust, humidifying and immunizing animals. In addition, it can also be used for the cooling and humidifying of squares, venues and streets in summer. The energy-storing high pressure spray cooling system has a broad application prospect.
基金Supported by the National Natural Science Foundation of China(50576034)~~
文摘Micro-turbine engine has no enough space for measuring impeller characteristics,so the design and the construction of a new test facility of micro-turbo-machinery are presented for micro-centrifugal compressors and radial turbines.The facility is used for the full speed compressor test and the long duration hot turbine test.To rapidly adjust the testing condition,all regulations of the operating state are automatically completed by the control system.The facility is also used for testing the impeller performance with a series of diameter from 55 mm to 180 mm as a result of the modular design.A thermal protection system is designed to avoid the heat distortion caused by the high turbine inlet temperature over 1 100 K and provide a proper experimental environment for the electronic components.A photoelectric torque transducer with the accuracy of 1% is designed to measure the torque of rigid shaft at a high speed of 125 000 r/min.The designing techniques for micro-turbo-machineries are verified by the impeller testing of the facility.
基金The National Natural Science Foundation of China(No.70671021)the National Key Technology R&D Program of China during the 11th Five-Year Plan Period(No.2006BAH02A06)
文摘To smooth the correlation process from bio-virus diffusion to emergency relief response,the Gaussian plume model is used to describe the diffusion of dangerous sources,where the bio-virus concentration at any given point in affected areas can be calculated.And the toxic load rule is introduced to define the borderline of the dangerous area at different levels.Combined with this,different emergency levels of different demand points in dangerous areas are confirmed using fuzzy clustering,which allows demand points at the same emergency level to cluster in a group.Some effective emergency relief centers are chosen from the candidate hospitals which are located in different emergency level affected areas by set covering.Bioterrorism experiments which were conducted in Nanjing,Jiangsu province are simulated,and the results indicate that the novel method can be used efficiently by decision makers during an actual anti-bioterrorism relief.
文摘With China's rapid development of the construction of modern campus,the school's increasing popularity and status as well as the growing number of foreign exchange.Current campus information,human development has gradually become a new issue on the development and construction of schools.The article through the analyzing on design features of the modern Campus Sign System to meet the needs of different groups,and the information can be effective used through the modern Campus Sign System between peoples and campus.So that in their daily life,work and other needs are fully met.
文摘The protein complex crystallographic beamline BL19U1 at the Shanghai Synchrotron Radiation Facility is one of the five beamlines dedicated to protein sciences operated by National Facility for Protein Science(Shanghai,China).The beamline,which features a small-gap invacuum undulator,has been officially open to users since March 2015.This beamline delivers X-ray in the energy range 7–15 keV.With its high flux,low divergence beam and a large active area detector,BL19U1 is designed for proteins with large molecular weight and large crystallographic unit cell dimensions.Good performance and stable operation of the beamline have allowed the number of Protein Data Bank(PDB)depositions and the number of articles published based on data collected at this beamline to increase steadily.To date,over 300 research groups have collected data at the beamline.More than 600 PDB entries have been deposited at the PDB(www.pdb.org).More than 300 papers have been published that include data collected at the beamline,including 21 research articles published in the top-level journals Cell,Nature,and Science.
基金supported by the National Natural Science Foundation of China (No.51575274)the National Defense Basic Scientific Research Program of China (No.JCKY2016605B006)the Key Research and Development Project of Jiangxi Province in China (No.20161ACE50004)
文摘Facility layout selection is a multi-criteria decision making (MCDM) problem,since it has a strategic impact on the efficiency of manufacturing system.In view of the interdependency among selection criteria,analytic network process (ANP) is proposed to analyze the structure of the facility layout selection problem and determine the weights for each criterion.A network structure is constructed that shows all elements and clusters and their interactions.Limit priorities are also calculated which help decision maker evaluate the relative importance among criterion in the alternative selection process.Moreover,a hybrid MCDM approach that employs ANP and technique for order preference by similarity to an ideal solution (TOPSIS)method to rank the optimal facility layout alternatives.Finally,an application of a new aeronautic component assembly workshop facility layout selection is conducted.To further illustrate the advantage of the proposed approach,the difference between ANP-TOPSIS and AHP-TOPSIS methods are compared and discussed.Results have demonstrated the effectiveness and feasibility of the proposed method.