期刊文献+
共找到1,141篇文章
< 1 2 58 >
每页显示 20 50 100
Reliability Analysis of Facility Systems Subject to Edge Failures: Based on the Uncapacitated Fixed-Charge Location Problem 被引量:1
1
作者 Zongtian Wei Huayong Xiao 《Open Journal of Discrete Mathematics》 2011年第3期153-159,共7页
A facility system can be modeled by a connected graph in which the vertices represent entities such as suppliers, distribution centers or customers and the edges represent facilities such as the paths of goods or info... A facility system can be modeled by a connected graph in which the vertices represent entities such as suppliers, distribution centers or customers and the edges represent facilities such as the paths of goods or information. The efficiency, and hence the reliability, of a facility system is to a large degree adversely affected by the edge failures in the network. Such failures may be caused by various natural disasters or terrorist attacks. In this paper, we consider facility systems’ reliability analysis based on the classical uncapacitated fixed-charge location problem when subject to edge failures. For an existing facility system, we formulate two models based on deterministic case and stochastic case to measure the loss in efficiency due to edge failures and give computational results and reliability envelopes for a specific example. 展开更多
关键词 facility system Reliability Edge FAILURE Uncapacitated Fixed-Charge LOCATION Problem
下载PDF
Analysis of Facility Systems’ Reliability Subject to Edge Failures: Based on the p-Median Problem 被引量:1
2
作者 Zongtian Wei Huayong Xiao Yuxi Quan 《American Journal of Operations Research》 2011年第4期277-283,共7页
We view a facility system as a kind of supply chain and model it as a connected graph in which the nodes represent suppliers, distribution centers or customers and the edges represent the paths of goods or information... We view a facility system as a kind of supply chain and model it as a connected graph in which the nodes represent suppliers, distribution centers or customers and the edges represent the paths of goods or information. The efficiency, and hence the reliability, of a facility system is to a large degree adversely affected by the edge failures in the network. In this paper, we consider facility systems' reliability analysis based on the classical p-median problem when subject to edge failures. We formulate two models based on deterministic case and stochastic case to measure the loss in efficiency due to edge failures and give computational results and reliability envelopes for a specific example. 展开更多
关键词 facility system Reliability EDGE FAILURE P-MEDIAN PROBLEM Operating Efficiency
下载PDF
Reliable Facility Systems Design Subject to Edge Failures: Based on the Uncapacitated Fixed-Charge Location Problem 被引量:1
3
作者 Yuangang Pan Yali Du Zongtian Wei 《American Journal of Operations Research》 2014年第3期164-172,共9页
The reliability of facility location problem has aroused wide concern recently. Many researchers focus on reliable and robust facility systems design under component failures and have obtained promising performance. H... The reliability of facility location problem has aroused wide concern recently. Many researchers focus on reliable and robust facility systems design under component failures and have obtained promising performance. However, the target and reliability of a facility system are to a large degree adversely affected by the edge failures in the network, which remains a deep study. In this paper, we focus on facility systems’ reliability subject to edge failures. For a facility location system, we formulate two models based on classical uncapacitated fixed-charge location problem under deterministic and stochastic cases. For a specific example, location decisions and the comparison of reliability under different location models are given. Extensive experiments verify that significant improvements in reliability can be attained simply by increasing the amount of operating cost. 展开更多
关键词 facility system Reliability Edge FAILURE Uncapacitated Fixed-Charge LOCATION Problem
下载PDF
Studies on the Economical and Practical Temperature Control Facility of Deep-Litter Systems for Swine Production
4
作者 林家彬 秦竹 +5 位作者 周忠凯 顾洪如 杨杰 汤赤 陈俊 余刚 《Agricultural Science & Technology》 CAS 2013年第7期1053-1056,共4页
Deep-Litter System is a high yield approach to raise swine with pollution free in a lower cost. In the research, based on the heat stress in summer caused by fermentation, three temperature-control systems were design... Deep-Litter System is a high yield approach to raise swine with pollution free in a lower cost. In the research, based on the heat stress in summer caused by fermentation, three temperature-control systems were designed, including natural ventilation through transoms, forced ventilation via fans, and cooling by hyperbaric spray system. Specifically, the latter intermittent auto-pressurized spray system developed in our lab, which could spray successively via pressure from storage tubes without wetting the fermentation bed, is suitable for the promotion with the deep-litter technology in rural regions , since the power consumption is only 1 kwh per day. 展开更多
关键词 Deep litter system Temperature control facilities Intermittent auto-pressurized spray system Economical and practical
下载PDF
Tuning control system of a third harmonic superconducting cavity in the Shanghai Synchrotron Radiation Facility 被引量:4
5
作者 Peng-Peng Gong Yu-Bin Zhao +6 位作者 Hong-Tao Hou Zhi-Gang Zhang Xiang Zheng Xiao-Yun Pu Kai Xu Qiang Chang Jian-Fei Liu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第10期123-132,共10页
Beam lifetime is dominated by Touschek scattering at the Shanghai Synchrotron Radiation Facility(SSRF).Touschek loss rate is affected by probability for scattering beyond the RF acceptance and the volume charge densit... Beam lifetime is dominated by Touschek scattering at the Shanghai Synchrotron Radiation Facility(SSRF).Touschek loss rate is affected by probability for scattering beyond the RF acceptance and the volume charge density of the bench.In the phaseⅡupgrade of the SSRF,a third harmonic superconducting cavity will be used to enhance the Touschek lifetime by lengthening the bunches.The Touschek lifetime improvement factor is affected by the voltage of a harmonic cavity.To stabilize the cavity voltage,a tuning control system was designed to control it.The design of the tuning control system was based on the SSRF third-generation low-level RF control system.Some hardware and specialized algorithms were redesigned to fit the harmonic cavity control.The design of the tuning control system is complete,and the control system has been tested.The test result shows that the fluctuation of amplitude is<±0.34%within 1.5 h,which satisfies the stability requirement. 展开更多
关键词 Passive HARMONIC CAVITY Low-level radio frequency SHANGHAI SYNCHROTRON Radiation facility Touschek LIFETIME
下载PDF
Fuzzy-AHP-Based Comprehensive Evaluation on Facility Management System of High-Rise Office Buildings 被引量:2
6
作者 ZHANG Peihong,WANG Kan,WAN Huanhuan,MA Zhongjiao(School of Environment Engineering,Shenyang Jianzhu University,Shenyang,China,110168) 《沈阳建筑大学学报(自然科学版)》 CAS 北大核心 2011年第2期324-330,共7页
The present building facility management status in China resulted in many problems such as high energy consumption,failure of automation control,services failure and poor indoor air quality.Based on questionnaires and... The present building facility management status in China resulted in many problems such as high energy consumption,failure of automation control,services failure and poor indoor air quality.Based on questionnaires and interviews to professional engineers and building users,a comprehensive evaluation index system was established on facility management of high-rise office buildings.A Fuzzy AHP based upon hierarchy criteria system was established.A Fuzzy AHP Evaluation Model on Facility Management System was set up;α-cut analysis was introduced and incorporated with expert knowledge together,which made up the optimism index λ.The fuzzy optimum crisp weight of each criterion was resulted from data-mining.Case investigations were processed in high-rise office buildings in Shenyang.The results illustrated that indoor air quality,thermal comfort and life cycle cost were the most important indexes in the evaluation of Facility Management System of high rise office buildings.Residents in high-rise buildings in Shenyang pay less attention to maintenance management and environment protection.By comparison with the analysis result of Export Choice,Fuzzy AHP-based evaluation model could act as a scientific reference for the establishment of governmental standards in facility management area in building. 展开更多
关键词 building facility management evaluation index Fuzzy AHP indoor air quality thermal comfort
下载PDF
Toward Cloud-Based Parking Facility Management System: A Preliminary Study 被引量:1
7
作者 Chung-Yang Chen Wen-Lung Tsai Tzu-Yin Chen 《Journal of Electronic Science and Technology》 CAS 2013年第2期181-186,共6页
An e-tag used on the freeway is a kind of passive sensors composed of sensors and radio- frequency identification (RFID) tags. The principle of the electronic toll collection system is that the sensor emits radio wa... An e-tag used on the freeway is a kind of passive sensors composed of sensors and radio- frequency identification (RFID) tags. The principle of the electronic toll collection system is that the sensor emits radio waves touching the e-tag within a certain range, the e-tag will respond to the radio waves by induction, and the sensor will read and write information of the vehicles. Although the RFID technology is popularly used in campus management systems, there is no e-tag technology application used in a campus parking system. In this paper, we use the e-tag technology on a campus parking management system based on the cloud-based construction. By this, it helps to achieve automated and standardized management of the campus parking system, enhance management efficiency, reduce the residence time of the vehicles at the entrances and exits, and improve the efficiency of vehicles parked at the same time. 展开更多
关键词 Cloud-based construction e-tag parking facility management system radio-frequencyidentification.
下载PDF
A mobile application framework of the BIM-based facility management system under the cross-platform structure 被引量:2
8
作者 Xiao Yaqi Hu Zhenzhong +1 位作者 Wang Wei Chen Xiangxiang 《Computer Aided Drafting,Design and Manufacturing》 2016年第1期58-65,共8页
The building information model/modeling (BIM) technology is currently applied in a broad range of applications and research for facility management, while the BIM-based mobile FM is difficult owing to various factor... The building information model/modeling (BIM) technology is currently applied in a broad range of applications and research for facility management, while the BIM-based mobile FM is difficult owing to various factors and environments. For example, the mobile applications usually require frequent cross-equipment compatibility. This paper proposes a reasonable BIM-based FM cross-platform framework and develops a mobile application on the basis of an existing BIM-based FM system. The developed mobile application is applied in a case study of a metro station project in Guangzhou to verify its effectiveness in FM practice. It helps maintenance staff in viewing BIMs, accessing related information, and updating maintenance records in a unique platform. The test results demonstrate that the proposed BIM-based cross-platform framework meet the FM application requirements and supports the extension of FM functions. 展开更多
关键词 facility management building information model/modeling mobile application CROSS-PLATFORM hybrid application
下载PDF
Numerical Simulation of a New 3D Isolation System Designed for a Facility with Large Aspect Ratio
9
作者 Ying Zhou Peng Chen 《Computer Modeling in Engineering & Sciences》 SCIE EI 2019年第9期759-777,共19页
This paper proposes a novel three-dimensional(3D)isolation system for facilities and presents the numerical simulation approach for the isolated system under earthquake excitations and impact effect using the OpenSees... This paper proposes a novel three-dimensional(3D)isolation system for facilities and presents the numerical simulation approach for the isolated system under earthquake excitations and impact effect using the OpenSees(Open System for Earthquake Engineering Simulation)software frame work.The 3D isolators combine the quasi-zero stiffness(QZS)system in the vertical direction and lead rubber bearing in the horizontal direction.Considering the large aspect ratio of the isolated facility,linear viscous dampers are designed in the vertical direction to diminish the overturning effect.The vertical QZS isolation system is characterized by a cubic force-displacement relation,thus,no elements or materials can model this mechanic behavior in the existing finite element software.This study takes advantage of the open source feature of the OpenSees to create a new material to represent the mechanic properties of the QZS system.Then the user-defined material is combined with the rubber isolator element to model the 3D isolator.Considering different soil types and input magnitudes,six sets of natural seismic records and artificial waves and half sine pulses are selected as the input excitations.A finite element model for the 3D isolated facility is established based on the combined element and the simulation is performed to calculate the time history response.The numerical simulation reveals the flexibility of the OpenSees to deal with new engineering problems,and the results prove that the new 3D isolation system can have an optimal isolation effect in both horizontal and vertical directions.The maximum acceleration response at the top of the facility is below the target limit,and the maximum deformation and the overturning motion of the isolation system can be controlled in a safe range. 展开更多
关键词 3D ISOLATION quasi-zero STIFFNESS OPENSEES facility large ASPECT ratio
下载PDF
Reliability Analysis of Systems Based on the UFLP under Facility Failure and Conditional Supply Cases
10
作者 Min Wang Zongtian Wei Yun He 《Advances in Pure Mathematics》 2012年第2期128-132,共5页
The reliability of facility location problems has been received wide attention for several decades. Researchers formulate varied models to optimize the reliability of location decisions. But the most of such studies a... The reliability of facility location problems has been received wide attention for several decades. Researchers formulate varied models to optimize the reliability of location decisions. But the most of such studies are not practical since the models are too ideal. In this paper, based on the classical uncapacitated fixed-charge location problem (UFLP) and some supply constraints from the reality, we distinguish deterministic facility failure and stochastic facility failure cases to formulate models to measure the reliability of a system. The computational results and reliability envelopes for a specific example are also given. 展开更多
关键词 Reliability Analysis facility FAILURE Supply CONSTRAINT Uncapacitated Fixed CHARGE Location Problem
下载PDF
Comprehensive Prevention and Control Strategies for Soil Continuous Cropping Obstacles of Facility Chili Pepper in Guangxi
11
作者 Jie QIN Qihan LUO +1 位作者 Shuifang ZHU Dexian HUANG 《Meteorological and Environmental Research》 2024年第5期70-72,共3页
As a crucial economic crop in Guangxi region,chili pepper is facing increasingly severe challenges of continuous cropping obstacles.In this paper,the causes of continuous cropping obstacles in chili pepper soil are de... As a crucial economic crop in Guangxi region,chili pepper is facing increasingly severe challenges of continuous cropping obstacles.In this paper,the causes of continuous cropping obstacles in chili pepper soil are deeply analyzed,covering multiple dimensions such as the dynamic changes in soil physicochemical properties,the imbalance of soil microbial community structure,and the gradual accumulation of soil borne diseases and pests.Subsequently,a set of comprehensive prevention and control strategy is proposed:soil improvement through the application of organic fertilizers,biological fertilizers,and soil conditioners;implementing agricultural strategies of crop rotation and intercropping,flexibly adjusting planting density and methods,to optimize crop layout and improve planting management measures;actively introducing natural enemies for biological control,while promoting the use of biopesticides and microbial preparations for biological control.In response to the actual situation of continuous cropping obstacles in chili pepper soil of Guangxi,it is suggested that innovative soil improvement technologies,improved planting management measures,and promotion of biological control methods should also be considered. 展开更多
关键词 facility agriculture Soil control Comprehensive prevention and control facility vegetables
下载PDF
Current status and countermeasures of facility fishery development
12
作者 ZHANG Wei DU CHenguang +7 位作者 ZHANG Nan YANG Dongfang CAI Chao DAI Yuan-yuan ZHANG Hong SHI Jianfei ZHANG peng WANG Jian 《Marine Science Bulletin》 2024年第1期81-90,共10页
According to the"National Modern Facility Agriculture Construction Plan(2023-2030)released by the Ministry of Agriculture and Rural Affairs,the"Special Implementation Plan for Modern Facility Fisheries Const... According to the"National Modern Facility Agriculture Construction Plan(2023-2030)released by the Ministry of Agriculture and Rural Affairs,the"Special Implementation Plan for Modern Facility Fisheries Construction"emphasizes the development of circular aquaculture,active expansion of green aquaculture space in facility fisheries,multi-channel development of food sources,comprehensive improvement of the quality,efficiency,and competitiveness of facility fisheries,ensuring stable and safe supply of aquatic products,and better meeting people's needs for high-quality aquatic products and beautiful aquatic ecological environment.Since the implementation of the 14th Five Year Plan for fisheries,facility fisheries have made significant progress.In order to thoroughly implement General Secretary Xi Jinping's important discourse on new quality productivity,conduct in-depth research on the current situation and existing problems of the fishery industry,and put forward suggestions to meet the requirements of high-quality development of the fishery industry in the new era.Therefore,it is crucial to continue practicing the"revitalization of aquatic seed industry"and"big food concept",take multiple measures to"demand food from rivers,lakes,and seas",and expand aquaculture space.Through research,it has been found that research in the field of facility based fisheries is still in its developmental stage.Further exploration is needed on the current status,breeding models,and experimental demonstrations of land-based facility based fisheries,in order to provide a basis for fisheries regulatory authorities to formulate the"15th Five Year Plan"for facility based fisheries. 展开更多
关键词 facility fisheries research status countermeasures and suggestions
下载PDF
Study on Soilless Culture of Facility Strawberry 被引量:3
13
作者 李永平 朱海生 +1 位作者 马宏棋 温庆放 《Agricultural Science & Technology》 CAS 2014年第7期1065-1068,共4页
[Objective] The aim was to establish a set of soilless cultivation and management method of facility strawberry cultivation in the south of China.[Method] In the research,strawberry species,substrate formulae,cultivat... [Objective] The aim was to establish a set of soilless cultivation and management method of facility strawberry cultivation in the south of China.[Method] In the research,strawberry species,substrate formulae,cultivation modes and nutri ent solutions were selected and optimized.[Result] Three-dimensional strawberry cultivation was much suitable for Frandy,Hongbao and Gumei No.1; substrate with coconut shred-mushroom residue-peat soil ratio at 2∶2∶1 was the optimal; the treatment C3,containing Ca(NO3)2·4H2O,KNO3,(NH4)2HPO4,MgSO4·7H2O,and NH4NO3 at 280,303,62,246 and 80 mg/L,promoted strawberry growth,and the cultivated strawberry was large and thick in leaves,thick in stem,dark green in leaf color,with best fruit yield and quality.Among three cultivation modes,the density,space use ratio and yield in the treatment with PVC pipes in A-shape were all higher and the strawberry was easier and more convenient for picking.[Conclusion] The research provides references for soilless cultivation of strawberry in the south of China. 展开更多
关键词 STRAWBERRY Soilless culture facility
下载PDF
Facility location model for a remanufacturing logistics network 被引量:1
14
作者 孙浩 达庆利 《Journal of Southeast University(English Edition)》 EI CAS 2008年第1期99-103,共5页
First a remanufactming logistics network is con- structed, in which the structure of both the forward logistics and the reverse logistics are of two levels and all the logistics facilities are capacitated. Both the re... First a remanufactming logistics network is con- structed, in which the structure of both the forward logistics and the reverse logistics are of two levels and all the logistics facilities are capacitated. Both the remanufactming products and the new products can be used to meet the demands of customers. Moreover, it is assumed that homogeneous facilities can be designed together into integrated ones, based on which a mixed integer nonlinear programming (MINLP) facility location model of the remanufacturing logistics network with six types of facilities to be sited is built. Then an algorithm based on enumeration for the model is given. The feasible combinations of binary variables are searched by enumeration, and the remaining sub-problems are solved by the LP solver. Finally, the validities of the model and the algorithm are illustrated by means of an example. The result of the sensitivity analysis of parameters indicates that the integration of homogeneous facilities may influence the optimal solution of the problem to a certain degree. 展开更多
关键词 reverse logistics remanufacturing logistics network facility location
下载PDF
Development of Energy-storing High Pressure Spray Cooling System
15
作者 林家彬 周忠凯 +7 位作者 秦竹 李辉 唐玉新 顾洪如 杨杰 汤赤 陈俊 余刚 《Agricultural Science & Technology》 CAS 2015年第1期167-171,共5页
The greenhouse has been increasingly used in the breeding industry. However, the high temperature inside the greenhouse in summer has not been effectively addressed. The spray cooling system sprays tiny droplets into ... The greenhouse has been increasingly used in the breeding industry. However, the high temperature inside the greenhouse in summer has not been effectively addressed. The spray cooling system sprays tiny droplets into the air. Thus the water molecules will be vaporized, absorbing heat and reducing ambient temperature. It is the only cooling method that can be used to cool the uneasily-sealed flexible greenhouse. We developed an energy-storing high pressure spray cooling system. The ordinary water pump is used as the source of high-pressure water. The partial kinetic energy is stored in the energy-storing tubes. When the water pump is stopped, the energy produced by releasing the compressed air can still be used to maintain the spray. And thus the use-cost and systematic wear would be reduced. The cooling system only requires 1 kilowatt hour of power per day. It has been widely used in summer to cool the breeding sheds. After a recent continuous improvement, its functions have been extended to disinfection, removing dust, humidifying and immunizing animals. In addition, it can also be used for the cooling and humidifying of squares, venues and streets in summer. The energy-storing high pressure spray cooling system has a broad application prospect. 展开更多
关键词 Energy-storing High pressure spray Spray cooling Energy-storing system facility agriculture
下载PDF
DESIGN OF NEW TEST FACILITY FOR MICRO-TURBO-MACHINERY
16
作者 夏晨 黄国平 陈杰 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2010年第4期288-298,共11页
Micro-turbine engine has no enough space for measuring impeller characteristics,so the design and the construction of a new test facility of micro-turbo-machinery are presented for micro-centrifugal compressors and ra... Micro-turbine engine has no enough space for measuring impeller characteristics,so the design and the construction of a new test facility of micro-turbo-machinery are presented for micro-centrifugal compressors and radial turbines.The facility is used for the full speed compressor test and the long duration hot turbine test.To rapidly adjust the testing condition,all regulations of the operating state are automatically completed by the control system.The facility is also used for testing the impeller performance with a series of diameter from 55 mm to 180 mm as a result of the modular design.A thermal protection system is designed to avoid the heat distortion caused by the high turbine inlet temperature over 1 100 K and provide a proper experimental environment for the electronic components.A photoelectric torque transducer with the accuracy of 1% is designed to measure the torque of rigid shaft at a high speed of 125 000 r/min.The designing techniques for micro-turbo-machineries are verified by the impeller testing of the facility. 展开更多
关键词 engines turbo-machinery test facility PERFORMANCE
下载PDF
Collaborative planning approach for anti-bioterrorism emergency facility location based on aerodynamics
17
作者 刘明 赵林度 《Journal of Southeast University(English Edition)》 EI CAS 2007年第S1期105-110,共6页
To smooth the correlation process from bio-virus diffusion to emergency relief response,the Gaussian plume model is used to describe the diffusion of dangerous sources,where the bio-virus concentration at any given po... To smooth the correlation process from bio-virus diffusion to emergency relief response,the Gaussian plume model is used to describe the diffusion of dangerous sources,where the bio-virus concentration at any given point in affected areas can be calculated.And the toxic load rule is introduced to define the borderline of the dangerous area at different levels.Combined with this,different emergency levels of different demand points in dangerous areas are confirmed using fuzzy clustering,which allows demand points at the same emergency level to cluster in a group.Some effective emergency relief centers are chosen from the candidate hospitals which are located in different emergency level affected areas by set covering.Bioterrorism experiments which were conducted in Nanjing,Jiangsu province are simulated,and the results indicate that the novel method can be used efficiently by decision makers during an actual anti-bioterrorism relief. 展开更多
关键词 emergency facility location Gaussian plume model(GPM) toxic load rule fuzzy clustering set covering
下载PDF
The Analysis and Research on Design Features of the Modern Campus Sign System 被引量:3
18
作者 赵莹 安秀 《海外英语》 2011年第9X期397-398,共2页
With China's rapid development of the construction of modern campus,the school's increasing popularity and status as well as the growing number of foreign exchange.Current campus information,human development ... With China's rapid development of the construction of modern campus,the school's increasing popularity and status as well as the growing number of foreign exchange.Current campus information,human development has gradually become a new issue on the development and construction of schools.The article through the analyzing on design features of the modern Campus Sign System to meet the needs of different groups,and the information can be effective used through the modern Campus Sign System between peoples and campus.So that in their daily life,work and other needs are fully met. 展开更多
关键词 SIGN system facility design ERGONOMICS
下载PDF
The protein complex crystallography beamline(BL19U1)at the Shanghai Synchrotron Radiation Facility 被引量:14
19
作者 Wei-Zhe Zhang Jian-Chao Tang +3 位作者 Si-Sheng Wang Zhi-Jun Wang Wen-Ming Qin Jian-Hua He 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第11期30-40,共11页
The protein complex crystallographic beamline BL19U1 at the Shanghai Synchrotron Radiation Facility is one of the five beamlines dedicated to protein sciences operated by National Facility for Protein Science(Shanghai... The protein complex crystallographic beamline BL19U1 at the Shanghai Synchrotron Radiation Facility is one of the five beamlines dedicated to protein sciences operated by National Facility for Protein Science(Shanghai,China).The beamline,which features a small-gap invacuum undulator,has been officially open to users since March 2015.This beamline delivers X-ray in the energy range 7–15 keV.With its high flux,low divergence beam and a large active area detector,BL19U1 is designed for proteins with large molecular weight and large crystallographic unit cell dimensions.Good performance and stable operation of the beamline have allowed the number of Protein Data Bank(PDB)depositions and the number of articles published based on data collected at this beamline to increase steadily.To date,over 300 research groups have collected data at the beamline.More than 600 PDB entries have been deposited at the PDB(www.pdb.org).More than 300 papers have been published that include data collected at the beamline,including 21 research articles published in the top-level journals Cell,Nature,and Science. 展开更多
关键词 MX BEAMLINES Macromolecular CRYSTALLOGRAPHY Shanghai SYNCHROTRON Radiation facility SSRF-BL19U1
下载PDF
A Hybrid MCDM Approach Based on ANP and TOPSIS for Facility Layout Selection 被引量:7
20
作者 Zha Shanshan Guo Yu +1 位作者 Huang Shaohua Tang Pengzhou 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2018年第6期1027-1037,共11页
Facility layout selection is a multi-criteria decision making (MCDM) problem,since it has a strategic impact on the efficiency of manufacturing system.In view of the interdependency among selection criteria,analytic n... Facility layout selection is a multi-criteria decision making (MCDM) problem,since it has a strategic impact on the efficiency of manufacturing system.In view of the interdependency among selection criteria,analytic network process (ANP) is proposed to analyze the structure of the facility layout selection problem and determine the weights for each criterion.A network structure is constructed that shows all elements and clusters and their interactions.Limit priorities are also calculated which help decision maker evaluate the relative importance among criterion in the alternative selection process.Moreover,a hybrid MCDM approach that employs ANP and technique for order preference by similarity to an ideal solution (TOPSIS)method to rank the optimal facility layout alternatives.Finally,an application of a new aeronautic component assembly workshop facility layout selection is conducted.To further illustrate the advantage of the proposed approach,the difference between ANP-TOPSIS and AHP-TOPSIS methods are compared and discussed.Results have demonstrated the effectiveness and feasibility of the proposed method. 展开更多
关键词 facility layout SELECTION MULTI-CRITERIA decision making(MCDM) ANALYTIC network process AHP TOPSIS
下载PDF
上一页 1 2 58 下一页 到第
使用帮助 返回顶部