It is important to achieve continuous, stable and efficient pumping well operation in actual oilfield operation. Down-hole pumping well working conditions can be monitored in real-time and a reasonable production sche...It is important to achieve continuous, stable and efficient pumping well operation in actual oilfield operation. Down-hole pumping well working conditions can be monitored in real-time and a reasonable production scheme can be designed when computer diagnosis is used. However, it is difficult to make a comprehensive analysis to supply efficient technical guidance for operation of the pumping well with multiple faults of down-hole conditions, which cannot be effectively dealt with by the common methods. To solve this problem, a method based on designated component analysis (DCA) is used in this paper. Freeman chain code is used to represent the down-hole dynamometer card whose important characteristics are extracted to construct a designated mode set. A control chart is used as a basis for fault detection. The upper and lower control lines on the control chart are determined from standard samples in normal working conditions. In an incompletely orthogonal mode, the designated mode set could be divided into some subsets in which the modes are completely orthogonal. The observed data is projected into each designated mode to realize fault detection according to the upper and lower control lines. The examples show that the proposed method can effectively diagnose multiple faults of down-hole conditions.展开更多
Aiming at the characteristics of complex logic relation and multiple dynamic gates in system,its failure probability model is established based on dynamic fault tree. For the multi-state dynamic fault tree,it can be t...Aiming at the characteristics of complex logic relation and multiple dynamic gates in system,its failure probability model is established based on dynamic fault tree. For the multi-state dynamic fault tree,it can be transferred into Markov chain with continuous parameters. The state transfer diagram can be decomposed into several state transfer chains,and the failure probability models can be derived according to the lengths of the chains. Then,the failure probability of the dynamic fault tree analysis(DFTA) can be obtained by adding each chain's probability. The failure probability calculation of DFTA based on the continuous parameter Markov chain is proposed and proved. Given an example,the analytic method is compared with the conventional methods which have to solve the differential equation. It is known from the results that the analytic method can be applied to engineering easily.展开更多
基金supported by the Key Program of National Natural Science Foundation of China (61034005)Postgraduate Scientific Research and Innovation Projects of Basic Scientific Research Operating Expensesof Ministry of Education (N100604001)Excellent Doctoral Dissertations Cultivation Project of Northeastern University
文摘It is important to achieve continuous, stable and efficient pumping well operation in actual oilfield operation. Down-hole pumping well working conditions can be monitored in real-time and a reasonable production scheme can be designed when computer diagnosis is used. However, it is difficult to make a comprehensive analysis to supply efficient technical guidance for operation of the pumping well with multiple faults of down-hole conditions, which cannot be effectively dealt with by the common methods. To solve this problem, a method based on designated component analysis (DCA) is used in this paper. Freeman chain code is used to represent the down-hole dynamometer card whose important characteristics are extracted to construct a designated mode set. A control chart is used as a basis for fault detection. The upper and lower control lines on the control chart are determined from standard samples in normal working conditions. In an incompletely orthogonal mode, the designated mode set could be divided into some subsets in which the modes are completely orthogonal. The observed data is projected into each designated mode to realize fault detection according to the upper and lower control lines. The examples show that the proposed method can effectively diagnose multiple faults of down-hole conditions.
文摘Aiming at the characteristics of complex logic relation and multiple dynamic gates in system,its failure probability model is established based on dynamic fault tree. For the multi-state dynamic fault tree,it can be transferred into Markov chain with continuous parameters. The state transfer diagram can be decomposed into several state transfer chains,and the failure probability models can be derived according to the lengths of the chains. Then,the failure probability of the dynamic fault tree analysis(DFTA) can be obtained by adding each chain's probability. The failure probability calculation of DFTA based on the continuous parameter Markov chain is proposed and proved. Given an example,the analytic method is compared with the conventional methods which have to solve the differential equation. It is known from the results that the analytic method can be applied to engineering easily.