Finite Element (FE) modeling under plane stress condition is used to analyze the fault type variation with depth along and around the San Andreas Fault (SAF) zone. In this simulation elastic rheology was used and was ...Finite Element (FE) modeling under plane stress condition is used to analyze the fault type variation with depth along and around the San Andreas Fault (SAF) zone. In this simulation elastic rheology was used and was thought justifiable as the variation in depth from 0.5 km to 20 km was considered. Series of calculations were performed with the variation in domain properties. Three types of models were created based on simple geological map of California, namely, 1) single domain model considering whole California as one homogeneous domain, 2) three domains model including the North American plate, Pacific plate, and SAF zone as separate domains, and 3) Four domains model including the three above plus the Garlock Fault zone. Mohr-Coulomb failure criterion and Byerlee's law were used for the calculation of failure state. All the models were driven by displacement boundary condition imposing the fixed North American plate and Pacific plate motion along N34°W vector up to the northern terminus of SAF and N50°E vector motion for the subducting the Gorda and Juan de Fuca plates. Our simulated results revealed that as the depth increased, the fault types were generally normal, and at shallow depth greater strike slip and some thrust faults were formed. It is concluded that SAF may be terminated as normal fault at depth although the surface expression is clearly strike slip.展开更多
Fault management study in smart grid systems (SGSs) is important to ensure the stability of the system. Also, it is important to know the major types of power failures for the effective operation of the SGS. This pape...Fault management study in smart grid systems (SGSs) is important to ensure the stability of the system. Also, it is important to know the major types of power failures for the effective operation of the SGS. This paper reviews diverse types of faults that might appear in the SGS and gives a survey about the impact of renewable energy resources (RERs) on the behavior of the system. Moreover, this paper offers different fault detection and localization techniques that can be used for SGSs. Furthermore, a potential fault management case study is proposed in this paper. The SGS model in this paper is investigated using both of the Matlab/Simulink and the Real Time Digital Simulation (RTDS) to compute the fault management study. Simulation results show the fast response to a power failure in the system which improves the stability of the SGS.展开更多
This paper proposes a novel controllable crowbar based on fault type(CBFT)protection technique for doubly fed induction generator(DFIG)wind energy conversion system connected to grid.The studied system consists of six...This paper proposes a novel controllable crowbar based on fault type(CBFT)protection technique for doubly fed induction generator(DFIG)wind energy conversion system connected to grid.The studied system consists of six DFIG wind turbines with a capacity of 1.5 MW for each of them.The operation mechanism of proposed technique is used to connect a set of crowbar resistors in different connection ways via activation of controllable circuit breakers(CBs)depending on the detected fault type.For each phase of DFIG,a crowbar resistor is connected in parallel with a controllable CB and all of them are connected in series to grid terminals.The adaptive neuro-fuzzy inference system(ANFIS)networks are designed to detect the fault occurrence,classify the fault type,activate the CBs for crowbar resistors associated with faulted phases during fault period,and deactivate them after fault clearance.The effectiveness of proposed CBFT protection technique is investigated for different fault types such as symmetrical and unsymmetrical faults taking into account the single-phase to ground fault is the most frequently fault type that occurs in power systems.Also,a comparison between the behaviours of studied system in cases of using traditional parallel rotor crowbar,classical outer crowbar,and proposed CBFT protection techniques is studied.The fluctuations of DC-link voltage,active power,and reactive power for studied system equipped with different protection techniques are investigated.Moreover,the impacts of different crowbar resistance values on the accuracy of proposed technique are studied.The simulation results show that,the proposed technique enhances the stability of studied wind turbine generators and contributes in protection of their components during faults.展开更多
In order to solve the problems of rotor overvoltage,overcurrent and DC side voltage rise caused by grid voltage drops,a coordinated control strategy based on symmetrical and asymmetrical low voltage ride through of ro...In order to solve the problems of rotor overvoltage,overcurrent and DC side voltage rise caused by grid voltage drops,a coordinated control strategy based on symmetrical and asymmetrical low voltage ride through of rotor side converter of the doubly-fed generator is proposed.When the power grid voltage drops symmetrically,the generator approximate equation under steady-state conditions is no longer applicable.Considering the dynamic process of stator current excitation,according to the change of stator flux and the depth of voltage drop,the system can dynamically provide reactive power support for parallel nodes and suppress the rise of DC side voltage and rotor over-current.When the grid voltage drops asymmetrically,the positive and negative sequence components are separated in the rotating coordinate system.The doubly fed generator model is established to suppress the rotor positive sequence current and negative sequence current respectively.At the same time,the output voltage limit of the converter is discussed,and the reference value is adjusted within the allowable output voltage range.In order to adapt to the occurrence of different types of power grid faults and complex operating conditions,a fast switching module of fault type detection and rotor control mode is designed to detect the type of power grid faults and voltage drop depth in real time and switch the rotor side control mode dynamically.Finally,the simulation model of the doubly fed wind turbine is constructed in Matlab/Simulink.The simulation results verify that the proposed control strategy can improve the low-voltage ride through performance of the system when dealing with the symmetrical and asymmetric voltage drop of the power grid and identify the power grid fault type and provide the correct control strategy.展开更多
In displacement-based seismic design, inelastic displacement ratio spectra (IDRS) are particularly useful for estimating the maximum lateral inelastic displacement demand of a nonlinear SDOF system from the maximum ...In displacement-based seismic design, inelastic displacement ratio spectra (IDRS) are particularly useful for estimating the maximum lateral inelastic displacement demand of a nonlinear SDOF system from the maximum elastic displacement demand of its counterpart linear elastic SDOF system. In this study, the characteristics of IDRS for near-fault pulse-type ground motions are investigated based on a great number of earthquake ground motions. The influence of site conditions, ratio of peak ground velocity (PGV) to peak ground acceleration (PGA), the PGV, and the maximum incremental velocity (MIV) on IDRS are also evaluated. The results indicate that the effect of near-fault ground motions on IDRS are significant only at periods between 0.2 s - 1.5 s, where the amplification can approach 20%. The PGV/PGA ratio has the most significant influence on IDRS among the parameters considered. It is also found that site conditions only slightly affect the IDRS.展开更多
文摘Finite Element (FE) modeling under plane stress condition is used to analyze the fault type variation with depth along and around the San Andreas Fault (SAF) zone. In this simulation elastic rheology was used and was thought justifiable as the variation in depth from 0.5 km to 20 km was considered. Series of calculations were performed with the variation in domain properties. Three types of models were created based on simple geological map of California, namely, 1) single domain model considering whole California as one homogeneous domain, 2) three domains model including the North American plate, Pacific plate, and SAF zone as separate domains, and 3) Four domains model including the three above plus the Garlock Fault zone. Mohr-Coulomb failure criterion and Byerlee's law were used for the calculation of failure state. All the models were driven by displacement boundary condition imposing the fixed North American plate and Pacific plate motion along N34°W vector up to the northern terminus of SAF and N50°E vector motion for the subducting the Gorda and Juan de Fuca plates. Our simulated results revealed that as the depth increased, the fault types were generally normal, and at shallow depth greater strike slip and some thrust faults were formed. It is concluded that SAF may be terminated as normal fault at depth although the surface expression is clearly strike slip.
文摘Fault management study in smart grid systems (SGSs) is important to ensure the stability of the system. Also, it is important to know the major types of power failures for the effective operation of the SGS. This paper reviews diverse types of faults that might appear in the SGS and gives a survey about the impact of renewable energy resources (RERs) on the behavior of the system. Moreover, this paper offers different fault detection and localization techniques that can be used for SGSs. Furthermore, a potential fault management case study is proposed in this paper. The SGS model in this paper is investigated using both of the Matlab/Simulink and the Real Time Digital Simulation (RTDS) to compute the fault management study. Simulation results show the fast response to a power failure in the system which improves the stability of the SGS.
文摘This paper proposes a novel controllable crowbar based on fault type(CBFT)protection technique for doubly fed induction generator(DFIG)wind energy conversion system connected to grid.The studied system consists of six DFIG wind turbines with a capacity of 1.5 MW for each of them.The operation mechanism of proposed technique is used to connect a set of crowbar resistors in different connection ways via activation of controllable circuit breakers(CBs)depending on the detected fault type.For each phase of DFIG,a crowbar resistor is connected in parallel with a controllable CB and all of them are connected in series to grid terminals.The adaptive neuro-fuzzy inference system(ANFIS)networks are designed to detect the fault occurrence,classify the fault type,activate the CBs for crowbar resistors associated with faulted phases during fault period,and deactivate them after fault clearance.The effectiveness of proposed CBFT protection technique is investigated for different fault types such as symmetrical and unsymmetrical faults taking into account the single-phase to ground fault is the most frequently fault type that occurs in power systems.Also,a comparison between the behaviours of studied system in cases of using traditional parallel rotor crowbar,classical outer crowbar,and proposed CBFT protection techniques is studied.The fluctuations of DC-link voltage,active power,and reactive power for studied system equipped with different protection techniques are investigated.Moreover,the impacts of different crowbar resistance values on the accuracy of proposed technique are studied.The simulation results show that,the proposed technique enhances the stability of studied wind turbine generators and contributes in protection of their components during faults.
基金The authors highly acknowledge the technology financial assistance provided by Jiangsu Frontier Electric Technology Co.,Ltd.(KJ202003).
文摘In order to solve the problems of rotor overvoltage,overcurrent and DC side voltage rise caused by grid voltage drops,a coordinated control strategy based on symmetrical and asymmetrical low voltage ride through of rotor side converter of the doubly-fed generator is proposed.When the power grid voltage drops symmetrically,the generator approximate equation under steady-state conditions is no longer applicable.Considering the dynamic process of stator current excitation,according to the change of stator flux and the depth of voltage drop,the system can dynamically provide reactive power support for parallel nodes and suppress the rise of DC side voltage and rotor over-current.When the grid voltage drops asymmetrically,the positive and negative sequence components are separated in the rotating coordinate system.The doubly fed generator model is established to suppress the rotor positive sequence current and negative sequence current respectively.At the same time,the output voltage limit of the converter is discussed,and the reference value is adjusted within the allowable output voltage range.In order to adapt to the occurrence of different types of power grid faults and complex operating conditions,a fast switching module of fault type detection and rotor control mode is designed to detect the type of power grid faults and voltage drop depth in real time and switch the rotor side control mode dynamically.Finally,the simulation model of the doubly fed wind turbine is constructed in Matlab/Simulink.The simulation results verify that the proposed control strategy can improve the low-voltage ride through performance of the system when dealing with the symmetrical and asymmetric voltage drop of the power grid and identify the power grid fault type and provide the correct control strategy.
基金National Natural Science Foundation of China Under Grants No. 50608024 andNo.50538050Opening Laboratory of Earthquake Engineering and Engineering Vibration Foundation Under Grant No.2007001
文摘In displacement-based seismic design, inelastic displacement ratio spectra (IDRS) are particularly useful for estimating the maximum lateral inelastic displacement demand of a nonlinear SDOF system from the maximum elastic displacement demand of its counterpart linear elastic SDOF system. In this study, the characteristics of IDRS for near-fault pulse-type ground motions are investigated based on a great number of earthquake ground motions. The influence of site conditions, ratio of peak ground velocity (PGV) to peak ground acceleration (PGA), the PGV, and the maximum incremental velocity (MIV) on IDRS are also evaluated. The results indicate that the effect of near-fault ground motions on IDRS are significant only at periods between 0.2 s - 1.5 s, where the amplification can approach 20%. The PGV/PGA ratio has the most significant influence on IDRS among the parameters considered. It is also found that site conditions only slightly affect the IDRS.