期刊文献+
共找到2,234篇文章
< 1 2 112 >
每页显示 20 50 100
Analysis of the Efficacy of Prenatal B-Ultrasound in Diagnosing Fetal Abnormalities
1
作者 Juan Chen Qiumin Li 《Journal of Clinical and Nursing Research》 2024年第5期47-51,共5页
Objective:To explore the positive significance of using prenatal B-ultrasound in diagnosing fetal abnormalities.Methods:A total of 200 pregnant women who visited Shaanxi Provincial People’s Hospital between January 2... Objective:To explore the positive significance of using prenatal B-ultrasound in diagnosing fetal abnormalities.Methods:A total of 200 pregnant women who visited Shaanxi Provincial People’s Hospital between January 2023 and January 2024 were recruited as the research subjects.All pregnant women received prenatal examinations.A retrospective analysis was carried out to analyze the positive significance of prenatal B-ultrasound examination in the diagnosis of fetal abnormalities.Results:Prenatal B-ultrasound examination detected 10 cases of fetal abnormalities,with a detection rate of 5.00%.When compared with the postnatal examination results of 5.50%,the difference was insignificant(P>0.05).Moreover,comparing the fetal limb abnormalities and cardiovascular abnormalities in prenatal B-ultrasound examination and postnatal examination,one case of congenital heart disease was missed in the prenatal B-ultrasound examination,and the others were consistent with the postnatal examination results,with a coincidence rate of 90.91%,indicating a high compliance rate.Conclusion:Fetal abnormalities have a great impact on mothers,babies,and families,and it is particularly important to strengthen diagnosis during this process.Prenatal B-ultrasound examination can improve the accuracy of diagnosis of fetal abnormalities and can be promoted in clinical practice as a basis for screening fetal abnormalities. 展开更多
关键词 Prenatal B-ultrasound fetal abnormalities Diagnostic value
下载PDF
Prenatal diagnosis of congenital fetal heart abnormalities and clinical analysis 被引量:10
2
作者 李辉 魏军 +1 位作者 马影 尚涛 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2005年第9期903-906,共4页
Objective: To study the value of detecting fetal congenital heart disease (CHD) using the five transverse planes technique of fetal echocardiography. Methods: Nine hundred and eighty-two high-risk pregnancies for feta... Objective: To study the value of detecting fetal congenital heart disease (CHD) using the five transverse planes technique of fetal echocardiography. Methods: Nine hundred and eighty-two high-risk pregnancies for fetal CHD were included in this study, the fetal heart was scanned with the five transverse planes technique of fetal echocardiography described by Yagel, autopsy was conducted when pregnancy was terminated. Blood from fetal heart was collected for fetal chromosome analysis. A close follow-up was given for normal fetal heart pregnancies and neonatal echocardiography was performed to check the accuracy of prenatal diagnosis. Results: (1) Forty-six cases (4.68%) were found to have fetal heart abnormalities in this study, 69.56% of them were diagnosed by single four-chamber view, another 30.43% fetal CHD were found by combining other views; (2) Forty-one parents of prenatal fetuses with CHD chose to terminate pregnancy, thirty-two of them gave consent to conduct autopsy, 93.75% of which yielded unanimous conclusion between prenatal fetal echocardiography and autopsy; (3) Thirty-two of 46 cases underwent fetal chromosome analysis, 8 cases (25%) were found to have abnormal chromosome; (4) Five cases were found to have right ventricle and atrium a little bigger than those on the left side, with the unequal condition being the same after birth, but there were no clinical manifestations and they are healthy for the time being; (5) Nine hundred and thirty-six cases were not found with abnormality in this study, but one case was diagnosed with ventricular septal defect after birth, one case was diagnosed with patent ductus arteriosus, one case had atrial septal defect after birth. Conclusions: (1) The detected CHD rate was 4.68% by screening fetal heart with five transverse planes according to Yagel’s description of high risk population basis for CHD. The coinciding rate of prenatal diagnosis and autopsy was 93.75%; (2) The sensitivity of detecting fetal heart abnormality is 92%, the specificity is 99.6% using the five transverse planes technique of fetal echocardiography; (3) Fetuses with mild or moderate disproportion of right and left side in the heart are potentially healthy babies. 展开更多
关键词 FETUS heart abnormALITY PRENATAL Diagnosis
下载PDF
Heart abnormality associates with a wide spectrum of psychiatric disorders:Evidence from Mendelian randomization analyses
3
作者 Xue-Shi Chen Zi-Yan Song +2 位作者 Xuan-Long Chen Yi-Ming Bo Li-Liang Li 《World Journal of Psychiatry》 SCIE 2024年第12期1988-1991,共4页
Psychiatric disorders and heart abnormality are closely interconnected.Previous knowledge has been well-established that psychiatric disorders can lead to increased cardiovascular morbidity and even sudden cardiac dea... Psychiatric disorders and heart abnormality are closely interconnected.Previous knowledge has been well-established that psychiatric disorders can lead to increased cardiovascular morbidity and even sudden cardiac death.Conversely,whether heart abnormality contributes to psychiatric disorders remains rarely studied.The work by Zhang et al pointed out that chronic heart failure had effects on the anxiety and depression(AD)severity,and indices including left ventricular ejection fraction,N-terminal pro-brain natriuretic peptide and interleukin-6 were independent risk factors for AD severity.In addition to the aforementioned AD,we herein find that heart failure might additionally impact the development of autism spectrum disorder and post-traumatic stress disorder(albeit P>0.05),and significantly protects against the presence of attention deficit hyperactivity disorder(ADHD),[odds ratio(OR)=0.61,P=0.0071]by using a Mendelian randomization analysis.Bradycardia is also a protective factor for ADHD(OR=0.61,P=0.0095),whereas hypertrophic cardiomyopathy is a mild risk factor for schizophrenia(OR=1.02,P=0.032).These data suggest a wide spectrum of psychiatric disorders secondary to heart abnormality,and we highlight more psychiatric care that should be paid to patients with heart abnormality. 展开更多
关键词 Psychiatric disorders SCHIZOPHRENIA heart abnormality heart failure Mendelian randomization analyses
下载PDF
Noninvasive Prenatal Testing for Fetal Chromosomal Abnormalities Using Massively Parallel Sequencing: Clinical Experience from 7910 Korean Pregnancies 被引量:2
4
作者 Seon Young Yun Hyuk Jung Kwon +6 位作者 Amit Goyal Katiyar P. Shashank Heesu Im Joungsu Joo Jin-Sik Bae Min Seob Lee Sunghoon Lee 《Open Journal of Genetics》 2018年第3期42-53,共12页
Objective: The purpose of this study is to review the clinical experience and performance of noninvasive prenatal testing (NIPT) method, using cell-free DNAto detect chromosomes 21, 18, 13, X, and Y abnormalities in o... Objective: The purpose of this study is to review the clinical experience and performance of noninvasive prenatal testing (NIPT) method, using cell-free DNAto detect chromosomes 21, 18, 13, X, and Y abnormalities in over 7910 clinical samples from South Korean population. Method: Pregnant women between 1st of November 2015 to 18th of February 2018, with obstetric clinical findings participated in the study. NIPT was performed based on masivelly parallel sequencing with 0.3× low coverage paired-end sequencing using cell-free DNA in maternal plasma. Further invasive prenatal testing was recommended for pregnant women with positive NIPT results. Results: Of the total 7910 participants, 7890 (99.75%) were tested for NIPT and the remaining 20 (0.25%) were below the Quality Control (QC) standards. T13, T18, XXX, XXY and XYY had 100% of sensitivity, specificity, positive predictive values (PPV) and accuracy. The overall sensitivity was 100% and specificity, PPV and accuracy of all chromosomal abnormalities with further validation were 99.92%, 94.25%, and, 99.92% respectively. Conclusion: Our NIPT results showed high positive predictive value for the detection of autosomal trisomies and sex chromosome aneuploidies in our sample cohort. 展开更多
关键词 CELL-FREE DNA TRISOMY Clinical Performance MOSAICISM CPM fetal abnormality NONINVASIVE Prenatal Testing NIPT
下载PDF
The Impacts of Maternal Gestational Diabetes Mellitus (GDM) on Fetal Hearts 被引量:20
5
作者 CHU Chen GUI Yong Hao +1 位作者 PEN Yun Yun SHI Li Ye 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2012年第1期15-22,共8页
Objective To evaluate the fetal cardiac function in gestational diabetes mellitus (GDM) pregnancies under different maternal glycemic controls. Methods Forty four GDM mothers received 78 fetal echocardiographic eval... Objective To evaluate the fetal cardiac function in gestational diabetes mellitus (GDM) pregnancies under different maternal glycemic controls. Methods Forty four GDM mothers received 78 fetal echocardiographic evaluations at three gestational periods (〈28, 28-34 and ≥34 weeks) and were divided into poorly-(DM1) and well-(DM2) controlled groups according to their glycemic control at examination. Seventy uncomplicated mothers were selected as controls. Parameters of fetal cardiac anatomy and function were measured and analyzed. Results GDM fetuses' cardiac ventricular walls were thicker than controls', and the differences between DM1 and DM2 were not significant except for end-diastolic left ventricular walls. In both GDM groups, the aortic flow velocities increased earlier than pulmonary artery and DM1 fetuses changed earlier than DM2 ones. GDM fetuses' left atrial shortening fraction was smaller than the controls' in the period of ≥34 weeks and negatively correlated with thicknesses of left ventricular walls and interventricular septum in DM1 fetuses (r=-0.438 and -0.506). The right ventricular diastolic function in DM1 and DM2 fetuses decreased after the period of 28-34 weeks and in the period of ≥34 weeks respectively. Tel index of both left and right ventricles increased in DM1 group after the period of 〈28 weeks and in DM2 group only in the period of ≥ 34 weeks, with no significant differences between DM1 and DM2 groups in this period. Conclusion Fetuses of GDM mothers showed cardiac function impairments. Good maternal glycemic control may delay the impairments, but cannot reduce the degree. Some cardiac changes in GDM fetuses were similar to those in pregestational diabetic pregnancies except for several parameters and their changing time. 展开更多
关键词 Gestational diabetes mellitus (GDM) fetal hearts Tel Index Glycemic contro
下载PDF
Valvuloplasty of fetal pulmonary atresia with intact ventricular septum and hypoplastic right heart: Mid-term follow-up results 被引量:3
6
作者 Gang Luo Shuai Gao +4 位作者 Hongxiao Sun Zhixian Ji Dunliang Wang Yue Sun Silin Pan 《Journal of Interventional Medicine》 2022年第4期196-199,共4页
Objective:This study aimed to analyze and evaluate the results of mid-term follow-up after fetal pulmonary valvuloplasty(FPV)in fetuses with pulmonary atresia with intact ventricular septum(PA/IVS).Methods:From August... Objective:This study aimed to analyze and evaluate the results of mid-term follow-up after fetal pulmonary valvuloplasty(FPV)in fetuses with pulmonary atresia with intact ventricular septum(PA/IVS).Methods:From August 31,2018,to May 31,2019,seven fetuses with PA/IVS and hypoplastic right heart were included in this study.All underwent echocardiography by the same specialist and were operated on by the same team.Intervention and echocardiography data were collected,and changes in the associated indices noted during follow-up were analyzed.Results:All seven fetuses successfully underwent FPV.The median gestational age at FPV was 27.54 weeks.The average FPV procedural time was 6 min.Persistent bradycardia requiring treatment occurred in 4/7 procedures.Finally,five pregnancies were successfully delivered,and the other two were aborted.Compared to data before fetal cardiac interventions(FCI),tricuspid valve annulus diameter/mitral valve annulus diameter(TV/MV)and right ventricle diameter/left ventricle diameter(RV/LV)of all fetuses had progressively improved.The maximum tricuspid regurgitation velocity decreased from 4.60 m/s to 3.64 m/s.The average follow-up time was 30.40±2.05 months.During the follow-up period,the diameter of the tricuspid valve ring in five children continued to improve,and the development rate of the tricuspid valve was relatively obvious from 6 months to 1 year after birth.However,the development of the right ventricle after birth was relatively slow.It was discovered that there were individual variations in the development of the right ventricle during follow-up.Conclusion:The findings support the potential for the development of the right ventricle and tricuspid valve in fetuses with PA/IVS who underwent FCI.Development of the right ventricle and tricuspid valve does not occur synchronously during pregnancy.The right ventricle develops rapidly in utero,but the development of tricuspid valve is more apparent after birth than in utero. 展开更多
关键词 Congenital heart disease fetal cardiac intervention fetal pulmonary valvuloplasty hypoplastic right heart syndrome pulmonary atresia with intact septum
下载PDF
Critical evaluation of American categorization of fetal heart rate (FHR) decelerations and three tier classification—Shortcomings, contradictions, remedies and need for debate 被引量:1
7
作者 Shashikant L. Sholapurkar 《Open Journal of Obstetrics and Gynecology》 2013年第3期362-370,共9页
Fetal heart rate (FHR) decelerations are the commonest aberrant feature on cardiotocograph (CTG) thus having a major influence on classification ofFHRpatterns into the three tier system. The unexplained paradox of ear... Fetal heart rate (FHR) decelerations are the commonest aberrant feature on cardiotocograph (CTG) thus having a major influence on classification ofFHRpatterns into the three tier system. The unexplained paradox of early decelerations (head compression—an invariable phenomenon in labor) being extremely rare [1] should prompt a debate about scientific validity of current categorization. This paper demonstrates that there appear to be major fallacies in the pathophysiological hypothesis (cord compression—baroreceptor mechanism) underpinning of vast majority of (variable?) decelerations. Rapid decelerations during contractions with nadir matching peak of contractions are consistent with “pure” vagal reflex (head compression) rather than result of fetal blood pressure or oxygenation changes from cord compression. Hence, many American authors have reported that the abrupt FHR decelerations attributed to cord compression are actually due to head compression [2-6]. The paper debates if there are major fundamental fallacies in current categorization of FHR decelerations based concomitantly on rate of descent (reflecting putative aetiology?) and time relationship to contractions. Decelerations with consistently early timing (constituting majority) seem to get classed as “variable” because of rapid descent. A distorted unscientific categorization of FHR decelerations could lead to clinically unhelpful three tier classification system. Hence, the current unphysiological classification needs a fresh debate with consideration of alternative models and re-evaluation of clinical studies to test these. Open debate improves patient care and safety. The clue to benign reflex versus hypoxic nature of decelerations seems to be in the timing rather than the rate of descent. Although the likelihood of fetal hypxemia is related to depth and duration ofFHRdecelerations, the cut-offs are likely to be different for early/late/variable decelerations and it seems to be of paramount importance to get this discrimination right for useful visual or computerized system of CTG interpretation. 展开更多
关键词 CARDIOTOCOGRAPHY Electronic fetal MONITORING fetal heart Rate Decelerations INTRAPARTUM fetal MONITORING INTRAPARTUM fetal Surveillance
下载PDF
Association between Fetal Heart Rate Monitoring during Labor and Neonatal Acidosis in Full-Term Newborns: A Retrospective Multicenter Cohort Study 被引量:1
8
作者 Anne-Charlotte Faivre Salma Tazi +5 位作者 Jan Chrusciel Stéphane Sanchez Nathalie Bednarek René Gabriel Perrine Moussy Olivier Graesslin 《Open Journal of Obstetrics and Gynecology》 2020年第9期1265-1278,共14页
<strong>Introduction: </strong><span style="font-family:""><span style="font-family:Verdana;">Fetal heart rate monitoring during labor is used to study fetal well-being... <strong>Introduction: </strong><span style="font-family:""><span style="font-family:Verdana;">Fetal heart rate monitoring during labor is used to study fetal well-being and predict neonatal acidosis of newborn. Fetal heart rate monitoring is analyzed by the obstetrical team and categorized according to the FIGO guidelines. An important limitation of this diagnostic tool is an inter- and intra-observer variability, leading to subjective cardiotocography interpretation and classification. Our objective was to study the association between the categories of fetal heart rate analysis (according to FIGO classification) and neonatal acidosis of full-term newborns. </span><b><span style="font-family:Verdana;">Study design:</span></b><span style="font-family:Verdana;"> This is a multicenter retrospective cohort study conducted between 2014 and 2018 in the Grand-Est region. We searched and included retrospectively children hospitalized in a pediatric intensive care unit in one of the participating hospitals with an ICD-10 coding type “P91.6” corresponding to “Hypoxic Ischemic Encephalopathy”. Maternal, pregnancy, delivery, and newborn characteristics were collected and compared by univariate logistic regression with multiple imputation. Odds Ratio and 95% confidence intervals (CI) were calculated using the model and presented. Multiple imputation with m = 100 imputations was tested, using Rubin rules to combine the results. </span><b><span style="font-family:Verdana;">Results: </span></b><span style="font-family:Verdana;">55 patients were included in the study. Fetal heart rate tracings classified in Category 3 as “pathological” according to FIGO guidelines were significantly associated with an increased risk of severe neonatal acidosis. Late decelerations and bradycardia during labor were associated with severe neonatal acidosis. </span><b><span style="font-family:Verdana;">Conclusion:</span></b><span style="font-family:Verdana;"> Severe neonatal acidosis may be suspected by interpretation of fetal heart rate during labor. Fetal bradycardia and late decelerations are predictive of the severity of neonatal acidosis. This study emphasizes the need to screen severe neonatal acidosis and allows the identification of populations most at risk. Repeated team training and upgrading of fetal heart rate study would further reduce the incidence of neonatal acidosis.</span></span> 展开更多
关键词 fetal heart Rate Neonatal Acidosis Third Stage of Labor NEWBORN
下载PDF
413 CASES OF ABNORMAL FETAL POSITION CORRECTED BY AURICULAR PLASTER THERAPY
9
作者 秦广凤 唐宏瑾 《Journal of Traditional Chinese Medicine》 SCIE CAS CSCD 1989年第4期235-237,共3页
The authors corrected the abnormal fetal posi-tion in 413 cases of pregnant women by the auri-cular plaster therapy(APT)with a success rate of83.3%—remarkably higher than treatment by knee-chest positioning.Further a... The authors corrected the abnormal fetal posi-tion in 413 cases of pregnant women by the auri-cular plaster therapy(APT)with a success rate of83.3%—remarkably higher than treatment by knee-chest positioning.Further analysis showed that APTwas also supperior to the knee-chest positioning forprimiparae,breech fetal position,and pregancies over33 weeks.The authors also noted the clinical signsof successful cases and failures. 展开更多
关键词 fetal PREGNANT CHEST noted POSITIONING corrected women FETUS remarkably abnormAL
下载PDF
Interpretation of British experts’ illustrations of fetal heart rate (FHR) decelerations by Consultant Obstetricians, registrars and midwives: A prospective study—Reasons for major disagreement with experts and implications for clinical practice
10
作者 Shashikant L. Sholapurkar 《Open Journal of Obstetrics and Gynecology》 2013年第6期454-465,共12页
Objective: To test the reproducibility of British experts’ (eFM, K2MS, Gibb and Arulkumaran) [1-3] illustrations of fetal heart rate (FHR) decelerations by trained British Obstetricians and midwives. To analyze reaso... Objective: To test the reproducibility of British experts’ (eFM, K2MS, Gibb and Arulkumaran) [1-3] illustrations of fetal heart rate (FHR) decelerations by trained British Obstetricians and midwives. To analyze reasons for any discrepancies by examining factors relating to the participants, British experts’ descriptions and NICE guidelines [4]. Design: Prospective observational study. Setting: National Health Service (NHS) Hospitals. Participants: 38 Obstetric Consultants, 49 registrars and 45 midwives. Methods: Printed questionnaire. Statistical Analysis: Fisher’s Exact test. Results: This largest study of its kind showed almost unbelievably high disconnect between CTG interpretation by experts and participants. 98% - 100% midwives, 80% - 100% Registrars and 74% - 100% Consultants categorized FHR decelerations differently from the five experts’ illustrations/interpretations (p < 0.0001). Remarkably, the three experts’ illustrations of early (supposedly most benign) decelerations were classed as atypical variable by 56% Consultants, 78% Registrars and 99% midwives and the CTGs as pathological by 85% of the participants. Conclusions: The high degree of disagreement with the experts’ illustrations (p < 0.0001) did not appear to be due to participant factors. The immediate reasons seemed to be the conflicting illustrations and heterogeneity of experts’ descriptions. But most importantly, these appeared to stem from non-standardized ambiguous definitions of FHR decelerations and many intrinsic systemic flaws in the current NICE guidelines [4]. The NICE concept of “true uniform” (identical) early and late decelerations seems biologically implausible (a myth) and no examples can be found. Another myth seems to be that early and late decelerations should be gradual. Only very shallow decelerations will look “gradual” on the British CTG. These systemic flaws lead to dysfunctional CTG interpretation increasing intervention as well as impairing diagnosis of fetal hypoxemia. This is because the vast majority of FHR decelerations fall in a single heterogeneous “variable” group with many further classed as “atypical” (pathological) based on disproven and discredited criteria [5-7]. There is increasing evidence in USA that a system with variable decelerations as the majority is clinically unhelpful because of loss of information [5-9]. In the interest of patient care and safety, open debate is necessary regarding a better way forward. Classification of FHR decelerations based primarily and solely on time relationship to contractions appears more scientific and clinically useful. 展开更多
关键词 fetal heart Rate Decelerations Electronic fetal MONITORING Cardiotocograph INTRAPARTUM MONITORING
下载PDF
The Diagnostic Accuracy of Automated Fetal Heart Echocardiography by Five Dimensional Compared to Two-Dimensional Ultrasound in the Second Trimester of Pregnancy
11
作者 Rehab M. Abdelrahman Ahmed R. M. Ramy Amr M. Abdelhady 《Open Journal of Obstetrics and Gynecology》 2018年第5期513-520,共8页
Objective: To compare the diagnostic accuracy of Fetal Intelligent Navigation Echocardiography (FINE) method by Five-Dimensional Ultrasound in automated fetal heart examination to conventional fetal heart examination ... Objective: To compare the diagnostic accuracy of Fetal Intelligent Navigation Echocardiography (FINE) method by Five-Dimensional Ultrasound in automated fetal heart examination to conventional fetal heart examination by Two-Dimensional ultrasound in second trimester pregnancy. Methods: 90 normal singleton pregnancies at the second trimester were enrolled in this prospective study. Fetal heart was examined by Two-Dimensional Ultrasound (2D US) and Five-Dimensional Ultrasound (FINE). Paired numerical data were compared using the paired samples t test. Inter-method agreement for the rating of the quality of cardiac views by 2D US or 5D US was assessed by calculation of the prevalence-adjusted and bias-adjusted kappa coefficient (PABAK). Results: There was no statistical significant difference between fetal heart echocardiography assessment using 2DUS or 5DUS(FINE) (p-value > 0.05). The overall inter-method agreement between 2D US and 5D US was 0.92. The difference in % of satisfactory views between 2D and 5D US was 1.73%, (95% CI - 0.5% to 3.33%) (P-value = 0.144). Conclusion: Our findings indicate the accuracy of 5DUS (FINE) echocardiography in evaluation of normal heart in the second trimester of pregnancy. 展开更多
关键词 fetal heart ECHOCARDIOGRAPHY fetal Intelligent Navigation ECHOCARDIOGRAPHY 5DUS
下载PDF
Abnormal Placental Findings Associated with Non-Reassuring Fetal Monitoring and Excellent Neonatal Outcomes
12
作者 Gary Ventolini Shanthi Ramesh +1 位作者 Sheela Barhan Ran Neiger 《International Journal of Clinical Medicine》 2011年第3期310-312,共3页
Objective: Obstetricians, Neonatologists, and Pathologists have studied gross histological analysis of human placentas in search of specific alterations in placental functions that can be correlated with neonatal outc... Objective: Obstetricians, Neonatologists, and Pathologists have studied gross histological analysis of human placentas in search of specific alterations in placental functions that can be correlated with neonatal outcomes. Our study assessed the prevalence of abnormal placental findings associated with non-reassuring fetal monitoring in labor requiring emergent instrumental or cesarean delivery, followed by an excellent neonatal outcome. Study Design: One hundred consecutive emergency deliveries, instrumental or cesarean, performed due to non-reassuring fetal monitoring while in labor were retrospectively evaluated. All patients were low-risk for obstetric complications, and had a singleton, term pregnancy. They had a normal antenatal routine testing and a normal anatomy ultrasound scan at 20 to 22 weeks gestation. Results: There were 35 placentas (35%) with gross placental anomalies at the delivery triage. Additionally 7 placentas (7%) were reported to be abnormal at the pathology examination. Conclusion: The prevalence of abnormal placental findings in our studied population was 42%. 展开更多
关键词 abnormal PLACENTAL FINDINGS EXCELLENT NEONATAL Outcomes Non-Reassuring fetal Monitoring
下载PDF
An Effective Machine-Learning Based Feature Extraction/Recognition Model for Fetal Heart Defect Detection from 2D Ultrasonic Imageries
13
作者 Bingzheng Wu Peizhong Liu +3 位作者 Huiling Wu Shunlan Liu Shaozheng He Guorong Lv 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第2期1069-1089,共21页
Congenital heart defect,accounting for about 30%of congenital defects,is the most common one.Data shows that congenital heart defects have seriously affected the birth rate of healthy newborns.In Fetal andNeonatal Car... Congenital heart defect,accounting for about 30%of congenital defects,is the most common one.Data shows that congenital heart defects have seriously affected the birth rate of healthy newborns.In Fetal andNeonatal Cardiology,medical imaging technology(2D ultrasonic,MRI)has been proved to be helpful to detect congenital defects of the fetal heart and assists sonographers in prenatal diagnosis.It is a highly complex task to recognize 2D fetal heart ultrasonic standard plane(FHUSP)manually.Compared withmanual identification,automatic identification through artificial intelligence can save a lot of time,ensure the efficiency of diagnosis,and improve the accuracy of diagnosis.In this study,a feature extraction method based on texture features(Local Binary Pattern LBP and Histogram of Oriented Gradient HOG)and combined with Bag of Words(BOW)model is carried out,and then feature fusion is performed.Finally,it adopts Support VectorMachine(SVM)to realize automatic recognition and classification of FHUSP.The data includes 788 standard plane data sets and 448 normal and abnormal plane data sets.Compared with some other methods and the single method model,the classification accuracy of our model has been obviously improved,with the highest accuracy reaching 87.35%.Similarly,we also verify the performance of the model in normal and abnormal planes,and the average accuracy in classifying abnormal and normal planes is 84.92%.The experimental results show that thismethod can effectively classify and predict different FHUSP and can provide certain assistance for sonographers to diagnose fetal congenital heart disease. 展开更多
关键词 Congenital heart defect fetal heart ultrasonic standard plane image recognition and classification machine learning bag of words model feature fusion
下载PDF
Analysis on the Hero’s Abnormal Psychology in The tell-tale heart
14
作者 王嘉维 《魅力中国》 2009年第13期8-9,共2页
The Tell-Tale Heart is one of the horror stories of Edgar Allan Poe's, who was a master of the horror tale in American. The hero in this story is always afraid of the eyes of an old man. He is extreme anxiety unde... The Tell-Tale Heart is one of the horror stories of Edgar Allan Poe's, who was a master of the horror tale in American. The hero in this story is always afraid of the eyes of an old man. He is extreme anxiety under the eyes, for avoiding this anxiety, he kills the old man. This paper is to analyze the hero's abnormal psychology. 展开更多
关键词 the hero abnormal psychology The Tell-Tale heart
下载PDF
Abnormal Uterine Bleeding due to Retention of Fetal Bones after Abortion: A Case Report
15
作者 Okafor Love Chimezirim Ogoke Nwakamma Chisom +3 位作者 William Oladiran Taiwo Simon Joseph Adagadzu Kingsley Iyoko Iseko Aminyene Essien Meraiyebu 《Open Journal of Obstetrics and Gynecology》 2023年第11期1881-1885,共5页
Background: Retention of fetal bones is a rare cause of abnormal uterine bleeding. Others may present as subfertility, chronic pelvic pain, abnormal vaginal discharge, menometrorrhagia, dysmenorrhea and spontaneous ex... Background: Retention of fetal bones is a rare cause of abnormal uterine bleeding. Others may present as subfertility, chronic pelvic pain, abnormal vaginal discharge, menometrorrhagia, dysmenorrhea and spontaneous expulsion of bony fragments. Incidence is 0.26% among patients undergoing hysteroscopy. Aim: To document a pattern of presentation of retained fetal bone and its management. Case Presentation: Our patient is an 18-year old who presented with vaginal bleeding of four weeks duration and managed for abnormal uterine bleeding due to retained fetal bone following second trimester abortion. Conclusion: The use of transvaginal ultrasound in making diagnosis of retained fetal bone is effective. Treatment by removal of bones through evacuation by dilatation and curettage or hysteroscopy brings about resolution of symptoms. Use of pelvic ultrasonography to confirm complete evacuation of the uterus after abortion especially second trimester abortion could aid in early diagnosis and management of incomplete abortion. 展开更多
关键词 abnormal Uterine Bleeding Retained fetal Bones ABORTION Transvaginal Ultrasound Dilatation and Curettage HYSTEROSCOPY
下载PDF
Creation of high position fetal balloon atrial septoplasty for hypoplastic left heart syndrome and highly restrictive atrial septum: A case report and literature review
16
作者 Ai Zhang Gang Luo +2 位作者 Yue Sun Taotao Chen Silin Pan 《Journal of Interventional Medicine》 2020年第1期55-57,共3页
Background:Fetal balloon atrial septoplasty(BAS)is performed through the restrictive foramen ovale in fetal cases with established hypoplastic left heart syndrome(HLHS)and an intact or highly restrictive atrial septum... Background:Fetal balloon atrial septoplasty(BAS)is performed through the restrictive foramen ovale in fetal cases with established hypoplastic left heart syndrome(HLHS)and an intact or highly restrictive atrial septum(RAS).Methods:In the current report,we present a case of high position BAS in a fetus with HLHS/RAS.Results:Echocardiography confirmed an adequate atrial opening above the foramen ovale and fetal pleural effusion resolved spontaneously 1 day after the procedure.Conclusion:To the best of our knowledge,the creation of a high position hole in the thinner part of the atrial septum,instead of the restrictive tiny hole,has not been reported in fetal cases with HLHS/RAS. 展开更多
关键词 Congenital heart disease fetal balloon atrial septoplasty Hypoplastic left heart syndrome Intact or highly restrictive atrial septum
下载PDF
Right heart modified myocardial performance index and ductus venosus spectrum parameters in pre-eclampsia fetuses for predicting adverse pregnancy outcomes
17
作者 GAO Jing LI Hezhou +4 位作者 WANG Ming WU Juan WANG Xinxia LIU Yun ZHU Ziqi 《中国医学影像技术》 CSCD 北大核心 2024年第8期1146-1150,共5页
Objective To observe the values of changes of right heart modified myocardial performance index(Mod-MPI)and ductus venosus(DV)spectrum parameters in pre-eclampsia fetuses for predicting adverse pregnancy outcomes.Meth... Objective To observe the values of changes of right heart modified myocardial performance index(Mod-MPI)and ductus venosus(DV)spectrum parameters in pre-eclampsia fetuses for predicting adverse pregnancy outcomes.Methods Eighty-one pregnant women diagnosed as pre-eclampsia were prospectively enrolled and divided into severe pre-eclampsia(SPE)group(n=39)and mild pre-eclampsia(MPE)group(n=42),while 85 healthy pregnant women were taken as controls(control group).Fetal right heart function parameters,including right ventricular isovolumetric relaxation time(IRT),isovolumetric contraction time(ICT),ejection time(ET),total spent time(TST),Mod-MPI,tricuspid valve peak flow velocity ratio in early and late diastole(TV-E/A),as well as blood flow velocities in each waveform of DV spectrum(S,V,D,and A wave)were obtained,and the pulsatility index(PI)and the ratio of blood flow velocities in each waveform of the DV(S/V,S/D,S/A,V/D,V/A,D/A)were calculated.Intrauterine fetal distress,preterm delivery,neonatal asphyxia and newborn with low weight were considered as adverse pregnancy outcomes.The correlations of right heart Mod-MPI and TV-E/A with DV parameters in pre-eclampsia fetuses were assessed,and their predictive efficacies for adverse pregnancy outcomes were evaluated for right heart Mod-MPI and DV using the receiver operating characteristics(ROC)and the area under the curves(AUC).Results Compared with control group and MPE group,fetal right heart IRT,ICT and Mod-MPI increased and ET decreased in SPE group(all P<0.05).No significant differences of right heart TST and TV-E/A among 3 groups(both P>0.05).Fetal DV A-wave velocity and V/D values progressively decreased but PI progressively increased in control,MPE and SPE groups(all P<0.05).Fetal right heart Mod-MPI in pre-eclampsia was moderately positively correlated with DV PI(r=0.637,P=0.016),while TV-E/A was weakly negatively correlated with DV V/D(r=-0.355,P=0.043).Adverse pregnancy outcomes were noticed in 59 pre-eclampsia cases.The AUC of fetal right heart Mod-MPI and DV PI for predicting adverse pregnancy outcomes in pre-eclampsia cases was 0.897 and 0.848,respectively,without significant difference(Z=0.460,P=0.400).Conclusion Changes of right heart Mod-MPI and DV spectrum parameters in pre-eclampsia fetuses had high value for predicting adverse pregnancy outcomes. 展开更多
关键词 PRE-ECLAMPSIA fetal heart ventricular function ultrasonography prenatal prospective studies
下载PDF
Unexplained fetal tachycardia:A case report
18
作者 Hui Wang Run-Zi Duan +3 位作者 Xin-Jiu Bai Bing-Ting Zhang Jie Wang Wen-Xia Song 《World Journal of Clinical Cases》 SCIE 2024年第9期1698-1703,共6页
BACKGROUND This study aimed to explore the possible etiology and treatment of severe fetal tachycardia in the absence of organic disease and provide a reference for clinical management of severe fetal tachycardia.CASE... BACKGROUND This study aimed to explore the possible etiology and treatment of severe fetal tachycardia in the absence of organic disease and provide a reference for clinical management of severe fetal tachycardia.CASE SUMMARY A 29-year-old pregnant woman,with a gravidity 1 parity 0,presented with a fetal heart rate(FHR)of 243 beats per minute during a routine antenatal examination at 31+2 wk of gestation.Before termination of pregnancy at 38 wk of gestation,the FHR repeatedly showed serious abnormalities,lasting more than 30 min.However,the pregnant woman and the fetus had no clinical symptoms,and repeated examination revealed no organic lesions.The mother and the baby were regularly followed up.CONCLUSION This was a case of severe fetal tachycardia with no organic lesions and management based on clinical experience. 展开更多
关键词 fetal heart rate disorder fetal tachycardia Severe tachycardia Case report
下载PDF
The Signal Extraction of Fetal Heart Rate Based on Wavelet Transform and BP Neural Network
19
作者 YANGXiao-hong ZHANGBang-cheng FUHu-dai 《Chinese Journal of Biomedical Engineering(English Edition)》 2005年第1期22-31,共10页
This paper briefly introduces the collection and recognition of bio-medical sig nals, designs the method to collect FM signals. A detailed discussion on the sys tem hardware, structure and functions is also given. Und... This paper briefly introduces the collection and recognition of bio-medical sig nals, designs the method to collect FM signals. A detailed discussion on the sys tem hardware, structure and functions is also given. Under LabWindows/CVI,the ha rdware and the driver do compatible, the hardware equipment work properly active ly. The paper adopts multi threading technology for real-time analysis and make s use of latency time of CPU effectively, expedites program reflect speed, impro ve s the program to perform efficiency. One threading is collecting data; the other threading is analyzing data. Using the method, it is broaden to analyze the sig nal in real-time. Wavelet transform to remove the main interference in the FM a nd by adding time-window to recognize with BP network; Finally the results of c ollecting signals and BP networks are discussed.8 pregnant women’s signals of F M were collected successfully by using the sensor. The correct of BP network rec ognition is about 83.3% by using the above measure. 展开更多
关键词 fetal heart rate Wavelet transform Signal reco gnition BP neural network
下载PDF
Stable Fetal Heart Rate after Phenylephrine Infusion during Spinal Anesthesia for Cesarean Delivery
20
作者 X.G. Guo M. Wang +1 位作者 C.B Han Y.N.Qian 《麻醉与监护论坛》 2012年第2期100-104,共5页
关键词 麻醉 监护 肾上腺素 临床
下载PDF
上一页 1 2 112 下一页 到第
使用帮助 返回顶部