Wilms' tumor is extremely rare.In this article,we reported one case diagnosed by fine needle aspiration cytology(FNAC) and pathology.A three and a half-year-old boy was admitted to hospital with abdominal pain for...Wilms' tumor is extremely rare.In this article,we reported one case diagnosed by fine needle aspiration cytology(FNAC) and pathology.A three and a half-year-old boy was admitted to hospital with abdominal pain for two days.CT scan showed a large mass in the region of the left kidney of the boy.FNAC was performed on the mass,and the cytologic specimen showed malignant cells suggestive of a Wilms' tumor.Histologic examination of the operative specimen after the left nephrectomy also revealed Wilms' tumor.展开更多
BACKGROUND Smear cytology(SC)using endoscopic ultrasound-guided fine needle aspiration(EUS-FNA)is the established and traditional choice for diagnosing pancreatic lesions.Liquid-based cytology(LBC)is a novel alternati...BACKGROUND Smear cytology(SC)using endoscopic ultrasound-guided fine needle aspiration(EUS-FNA)is the established and traditional choice for diagnosing pancreatic lesions.Liquid-based cytology(LBC)is a novel alternative cytological method,however,the comparative diagnostic efficacy of LBC remains inconclusive.AIM To examine the diagnostic efficacy of LBC and SC for pancreatic specimens obtained through EUS-FNA via a systematic review and meta-analysis.METHODS A systematic literature search was performed using PubMed,EMBASE,the Cochrane Library,and Web of Science.The numbers of true positives,false positives,true negatives,and false negatives for each cytological test(LBC and CS)were extracted from the included studies.The pooled sensitivity and specificity and the area under the summary receiver operating characteristic curve(AUC)were calculated,and the AUC was compared by Tukey's multiple comparisons test.The quality of the included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies II tool.RESULTS A total of 1656 patients in eight studies were included.The pooled sensitivity and specificity and the AUC for LBC were 0.76(95%CI:0.72-0.79),1.00(95%CI:0.98-1.00),and 0.9174,respectively,for diagnosing pancreatic lesions.The pooled estimates for SC were as follows:Sensitivity,0.68(95%CI:0.64-0.71);specificity,0.99(95%CI:0.96-100.00);and AUC,0.9714.Similarly,the corresponding values for LBC combined with SC were 0.87(95%CI:0.84-0.90),0.99(95%CI:0.96-1.00),and 0.9894.Tukey’s multiple comparisons test was used to compare the sensitivities and AUCs of the three diagnostic methods;statistically significant differences were found between the three methods,and LBC combined with SC was superior to both LBC(P<0.05)and SC(P<0.05).The pooled sensitivity and AUC did not change significantly in the sensitivity analysis.CONCLUSION LBC may be sensitive than SC in the cytological diagnosis of pancreatic lesions,however,the superior diagnostic performance of their combination emphasizes their integrated usage in the clinical evaluation of pancreatic lesions.展开更多
BACKGROUND: Endoscopic ultrasound-guided fine-needle aspiration cytology was demonstrated to be a useful tool for the diagnosis and staging of pancreaticobiliary neoplastic le- sions. Nonetheless, the diagnostic valu...BACKGROUND: Endoscopic ultrasound-guided fine-needle aspiration cytology was demonstrated to be a useful tool for the diagnosis and staging of pancreaticobiliary neoplastic le- sions. Nonetheless, the diagnostic value of this procedure may be limited by low cellularity of the specimen, contamination of intestinal cells and unfeasibility of ancillary immunocy- tochemical procedures. The present study was to evaluate its usefulness in the diagnosis of neoplastic lesions.展开更多
Objective:The aim of the study was to investigate the diagnostic value of fine needle aspiration cytology (FNAC) and its clinical application.Methods:From April 2009 to February 2011,thyroid FNAC were performed in a t...Objective:The aim of the study was to investigate the diagnostic value of fine needle aspiration cytology (FNAC) and its clinical application.Methods:From April 2009 to February 2011,thyroid FNAC were performed in a total of 186 patients with thyroid nodule or mass in our hospital and 78 of those 186 patients subsequently underwent thyroidectomy.The FNAC findings were compared with the results of the corresponding histological diagnosis.Results:The results of thyroid FNAC for 186 patients showed that,(1) 166 cases of benign lesions,the detection rate was 89.24% (166/186),including 96 cases of nodular colloid goiter (51.61%),28 cases of simple colloid goiter (15.05%),38 cases of Hashimoto's thyroiditis (HT) (20.43%) and 4 cases of thyroid adenoma (2.15%);(2) 4 cases of suspicious malignant lesion,the detection rate was 2.15% (4/186);(3) 16 cases of malignant tumor,the detection rate was 8.60% (16/186).Seventy eight patients including malignant (16),suspicious malignant (4),HT (20) and nodular colloid goiters (38) cases diagnosed by FNAC were performed operation with thyroidectomy and the postoperative histopathologic results showed that there were 2 cases HT combined thyroid papillary carcinoma in HT 20 cases by FNAC,15 cases of thyroid papillary carcinoma and 1 case of follicular carcinoma in 16 cases of malignant tumor by FNAC and 4 case of thyroid papillary carcinoma in 4 cases of suspicious malignant by FNAC.Conclusion:Thyroid FNAC is a valuable and reliable method for the diagnosis of the thyroid nodules or mass or even most diffuse thyroid diseases.Diagnosis of HT and thyroid papillary carcinoma can be made by thyroid FNAC.There was larger hint value for nodular colloid goiter and simple colloid goiter according to thyroid FNAC.展开更多
Objective: To evaluate the accuracy of these two methods and focus on the analysis and management of the false-negative cases. Methods: Results of full field digital mammography (FFDM) and fine needle aspiration cytol...Objective: To evaluate the accuracy of these two methods and focus on the analysis and management of the false-negative cases. Methods: Results of full field digital mammography (FFDM) and fine needle aspiration cytology (FNAC) were obtained and analyzed from a consecutive of 102 women with palpable breast masses, results were correlated with the histopathological findings. Results: Of the 102 cases, malignancy was confirmed in 43 cases (42.16%) by final pathological examination, the sensitivity and specificity of cancer detection with FNA cytology was 90.7% (39/43) and 89.8% (53/59), re- spectively, the whole accuracy was 90.2% (92/102), with a positive predictive value of 86.7% (39/45) and a negative predictive value of 93.0% (53/57). FFDM gave a sensitivity of 88.4% (38/43), specificity of 83.1% (49/59), and whole accuracy 85.3% (87/102), the positive predictive value and negative predictive value was 79.2% (38/48) and 90.7% (49/54), respectively. All the FNAC-negative cancer cases were suggestive of malignancy by FFDM findings, however, the benign cases which present as equivocal finding by FNA cytology, could not be ruled out the presence of malignancy. Conclusion: FNAC and FFDM both are accurate, effective and economical diagnostic modalities, combined use of these two methods can reduced the misdiag- nosis rate of breast masses.展开更多
This study examined cells contained in needles used for the collection of breast fine needle aspirates for the detection of malignant cells trapped in the needles. Remnants of cells contained in 50 needles used for th...This study examined cells contained in needles used for the collection of breast fine needle aspirates for the detection of malignant cells trapped in the needles. Remnants of cells contained in 50 needles used for the collection of scanty breast fine needle aspirates were examined by the liquid based cytology technique and compared with the conventional cytological technique of specimens in the corresponding syringes. The breast specimens were collected with clean sterile needles attached to the syringes. Smears were made and stained by the conventional method. The needles were removed from the syringes and a fixative was withdrawn into the syringes and the syringes were recapped with the needles. The fixative containing the specimen was then completely discharged into a centrifuge tube through the needles and treated by the liquid based cytology technique. The study revealed that cells were found trapped in all the needles used for the collection of breast FNA. 6% of them were positive for malignancy, similar to results obtained in the conventional method. Needles used for the collection of breast FNA should be examined before malignancy is completely ruled out particularly in extremely scanty specimens with a clinical suspicion of malignancy.展开更多
BACKGROUND:Endoscopic ultrasound-guided fine needle aspiration(EUS-FNA) has become a crucial diagnostic technique for pancreatic malignancies.The specimen obtained by EUS-FNA can be prepared for either cytological or ...BACKGROUND:Endoscopic ultrasound-guided fine needle aspiration(EUS-FNA) has become a crucial diagnostic technique for pancreatic malignancies.The specimen obtained by EUS-FNA can be prepared for either cytological or histological examinations.This study was to compare diagnostic performance of cytological and histological preparations using EUSFNA in the same lesions when pancreatic malignancies were suspected.METHODS:One hundred and eighteen patients who underwent EUS-FNA for suspected pancreatic malignancies were consecutively enrolled.All procedures were conducted by a single echoendoscopist under the same conditions.Four adequate preparations were obtained by 22-gauge needles with 20 to-and-fro movements for each pass.The 4 preparations included 2 cytological and 2 histological specimens.The pathologic reviews of all specimens were conducted independently by a single experienced cytopathologist.Sensitivity,specificity,and accuracy of the 2 preparations were compared.RESULTS:The enrolled patients consisted of 62 males(52.5%),with the mean age of 64.6±10.5 years.Surgery was performed in 23(19.5%) patients.One hundred and sixteen(98.3%) lesions were classified as malignant,while 2(1.7%) were benign.Sensitivity of cytology and histology were 87.9% and 81.9%,respectively,with no significant difference(P=0.190).Accuracy was also not significantly different.Cytological preparation was more sensitive when the size of lesion was <3 cm(86.7% vs 68.9%,P=0.033).CONCLUSIONS:Our results suggested that the diagnostic performances of cytological and histological preparations are not significantly different for the diagnosis of pancreatic malignancies.However,cytological preparation might be more sensitive for pancreatic lesions <3 cm.展开更多
The role of endoscopic ultrasound(EUS) in evaluating pancreatic pathology has been well documented from the beginning of its clinical use. High spatial resolution and the close proximity to the evaluated organs within...The role of endoscopic ultrasound(EUS) in evaluating pancreatic pathology has been well documented from the beginning of its clinical use. High spatial resolution and the close proximity to the evaluated organs within the mediastinum and abdominal cavity allow detection of small focal lesions and precise tissue acquisition from suspected lesions within the reach of this method. Fine needle aspiration(FNA) is considered of additional value to EUS and is performed to obtain tissue diagnosis. Tissue acquisition from suspected lesions for cytological or histological analysis allows, not only the differentiation between malignant and non-malignant lesions, but, in most cases, also the accurate distinction between the various types of malignant lesions. It is well documented that the best results are achieved only if an adequate sample is obtained for further analysis, if the material is processed in an appropriate way, and if adequate ancillary methods are performed. This is a multi-step process and could be quite a challenge in some cases. In this article, we discuss the technical aspects of tissue acquisition by EUS-guided-FNA(EUS-FNA), as well as the role of an on-site cytopathologist, various means of specimen processing, and the selection of the appropriate ancillary method for providing an accurate tissue diagnosis and maximizing the yield of this method. The main goal of this review is to alert endosonographers, not only to the different possibilities of tissue acquisition, namely EUS-FNA, but also to bring to their attention the importance of proper sample processing in the evaluation of various lesions in the gastrointestinal tract and other accessible organs. All aspects of tissue acquisition(needles, suction, use of stylet, complications, etc.) have been well discussed lately. Adequate tissue samples enable comprehensive diagnoses, which answer the main clinical questions, thus enabling targeted therapy.展开更多
Endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNA) is a useful procedure that enables reliable pathological diagnoses of pancreatobiliary diseases, subepithelial lesions, and swollen lymph nodes. In ...Endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNA) is a useful procedure that enables reliable pathological diagnoses of pancreatobiliary diseases, subepithelial lesions, and swollen lymph nodes. In recent years, a pathological diagnosis based on EUS-FNA has made it possible to provide accurate treatment methods not only in these fields, but also in respiratory organs and otorhinolaryngology. This review discusses the latest topics pertaining to EUS-FNA as well as procedural tips.展开更多
AIM To compare the aspiration needle(AN) and core biopsy needle(PC) in endoscopic ultrasound-guided fine needle aspiration(EUS-FNA) of abdominal masses.METHODS Consecutive patients referred for EUS-FNA were included i...AIM To compare the aspiration needle(AN) and core biopsy needle(PC) in endoscopic ultrasound-guided fine needle aspiration(EUS-FNA) of abdominal masses.METHODS Consecutive patients referred for EUS-FNA were included in this prospective single-center trial. Each patient underwent a puncture of the lesion with both standard 22-gauge(G) AN(Echo Tip Ultra; Cook Medical, Bloomington, Indiana, United States) and the novel 22 G PC(Echo Tip Pro Core; Cook Medical, Bloomington, Indiana, United States) in a randomized fashion; histology was attempted in the PC group only. The main study endpoint was the overall diagnostic accuracy, including the contribution of histology to the final diagnosis. Secondary outcome measures included material adequacy, number of needle passes, and complications.RESULTS Fifty six consecutive patients(29 men; mean age 68 years) with pancreatic lesions(n = 38), lymphadenopathy(n = 13), submucosal tumors(n = 4), or others lesions(n = 1) underwent EUS-FNA using both of the needles in a randomized order. AN and PC reached similar overall results for diagnostic accuracy(AN: 88.9 vs PC: 96.1, P = 0.25), specimen adequacy(AN: 96.4% vs PC: 91.1%, P = 0.38), mean number of passes(AN: 1.5 vs PC: 1.7, P = 0.14), mean cellularity score(AN: 1.7 vs PC: 1.1, P = 0.058), and complications(none). A diagnosis on the basis of histology was achieved in the PC group in 36(64.3%) patients, and in 2 of those as the sole modality. In patients with available histology the mean cellularity score was higher for AN(AN: 1.7 vs PC: 1.0, P = 0.034); no other differences were of statistical significance.CONCLUSION Both needles achieved high overall diagnostic yields and similar performance characteristics for cytological diagnosis; histological analysis was only possible in 2/3 of cases with the new needle.展开更多
AIM: To evaluate the diagnostic accuracy of histological evaluation of pancreatic tissue samples obtained by a modified method for recovering and processing the endoscopic ultrasound (EUS)-guided fine needle aspira...AIM: To evaluate the diagnostic accuracy of histological evaluation of pancreatic tissue samples obtained by a modified method for recovering and processing the endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) material in the differential diagnosis of pancreatic solid masses. METHODS: Sixty-two consecutive patients with pancreatic masses were prospectively studied. EUS was performed by the linear scanning Pentax FG-38UX echoendoscope. Three FNAs (22G needle) were carried out during each procedure. The materials obtained with first and second punctures were processed for cytological study. Haterials of the third puncture were recovered into 10% formol solution by careful injection of saline solution through the needle, and processed for histological study. RESULTS: Length of the core specimen obtained for histological analysis was 6.5±5.3 mm (range 1-22 mm). Cytological and histological samples were considered as adequate in 51 (82.3%) and 52 cases (83.9%), respectively. Overall sensitivity of both pancreatic cytology and histology for diagnosis of malignancy was 68.4%. Conbary to cytology, histology was able to diagnose tumours other than adenocarcinomas, and all cases of inflammatory masses. Combination of cytology and histology allowed obtaining an adequate sample in 56 cases (90.3%), with a global sensitivity of 84.21%, specificity of 100% and an overall accuracy of 90.32%. The complication rate was 1.6%.CONCLUSION: Adequate pancreatic core specimens for histological examination can be obtained by EUS-guided FNA. This technique is mainly useful for the diagnosis of different types of pancreatic tumours and evaluation of benign diseases.展开更多
Since its introduction,endoscopic ultrasound(EUS)guided fine needle aspiration and fine needle biopsy have become an indispensable tool for the diagnosis of lesions within the gastrointestinal tract and surrounding or...Since its introduction,endoscopic ultrasound(EUS)guided fine needle aspiration and fine needle biopsy have become an indispensable tool for the diagnosis of lesions within the gastrointestinal tract and surrounding organs.It has proved to be an effective diagnostic method with high accuracy and low complication rates.Several factors can influence the accuracy and the diagnostic yield of this procedure including experience of the endosonographer,availability of onsite cytopathology services,the method of cytopathology preparation,the location and physical characteristics of the lesion,sampling techniques and the type and size of the needle used.In this review we will outline the recent studies evaluating EUS-guided tissue acquisition and will provide practical recommendations to maximize tissue yield.展开更多
AIM To compare the accuracy of endoscopic ultra-sonography(EUS) 19 G core biopsies and 22 G core biopsies in diagnosing the correct etiology for a solid mass.METHODS Articles were searched in Medline, Pub Med, and Ovi...AIM To compare the accuracy of endoscopic ultra-sonography(EUS) 19 G core biopsies and 22 G core biopsies in diagnosing the correct etiology for a solid mass.METHODS Articles were searched in Medline, Pub Med, and Ovid journals. Pooling was conducted by both fixed and random effects models. RESULTS Initial search identified 4460 reference articles for 19 G and 22 G, of these 670 relevant articles were selected and reviewed. Data was extracted from 6 studies for 19G(n = 289) and 16 studies for 22G(n = 592) which met the inclusion criteria. EUS 19 G core biopsies had a pooled sensitivity of 91.6%(95%CI: 87.1-95.0) and pooled specificity of 95.9%(95%CI: 88.6-99.2), whereas EUS 22 G had a pooled sensitivity of 83.3%(95%CI: 79.7-86.6) and pooled specificity of 64.3%(95%CI: 54.7-73.1). The positive likelihood ratio of EUS 19 G core biopsies was 9.08(95%CI: 1.12-73.66) and EUS 22 G core biopsies was 1.99(95%CI: 1.09-3.66).The negative likelihood ratio of EUS 19 G core biopsies was 0.12(95%CI: 0.07-0.24) and EUS 22 G core biopsies was 0.25(95%CI: 0.14-0.41). The diagnostic odds ratio was 84.74(95%CI: 18.31-392.26) for 19 G core biopsies and 10.55(95% CI: 3.29-33.87) for 22 G needles. CONCLUSION EUS 19 G core biopsies have an excellent diagnostic value and seem to be better than EUS 22 G biopsies in detecting the correct etiology for a solid mass.展开更多
文摘Wilms' tumor is extremely rare.In this article,we reported one case diagnosed by fine needle aspiration cytology(FNAC) and pathology.A three and a half-year-old boy was admitted to hospital with abdominal pain for two days.CT scan showed a large mass in the region of the left kidney of the boy.FNAC was performed on the mass,and the cytologic specimen showed malignant cells suggestive of a Wilms' tumor.Histologic examination of the operative specimen after the left nephrectomy also revealed Wilms' tumor.
基金the Natural Science Foundation of Zhejiang Province,No.LQ20H160061Medical Health Science and Technology Project of Zhejiang Provincial Health Commission,No.2018255969.
文摘BACKGROUND Smear cytology(SC)using endoscopic ultrasound-guided fine needle aspiration(EUS-FNA)is the established and traditional choice for diagnosing pancreatic lesions.Liquid-based cytology(LBC)is a novel alternative cytological method,however,the comparative diagnostic efficacy of LBC remains inconclusive.AIM To examine the diagnostic efficacy of LBC and SC for pancreatic specimens obtained through EUS-FNA via a systematic review and meta-analysis.METHODS A systematic literature search was performed using PubMed,EMBASE,the Cochrane Library,and Web of Science.The numbers of true positives,false positives,true negatives,and false negatives for each cytological test(LBC and CS)were extracted from the included studies.The pooled sensitivity and specificity and the area under the summary receiver operating characteristic curve(AUC)were calculated,and the AUC was compared by Tukey's multiple comparisons test.The quality of the included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies II tool.RESULTS A total of 1656 patients in eight studies were included.The pooled sensitivity and specificity and the AUC for LBC were 0.76(95%CI:0.72-0.79),1.00(95%CI:0.98-1.00),and 0.9174,respectively,for diagnosing pancreatic lesions.The pooled estimates for SC were as follows:Sensitivity,0.68(95%CI:0.64-0.71);specificity,0.99(95%CI:0.96-100.00);and AUC,0.9714.Similarly,the corresponding values for LBC combined with SC were 0.87(95%CI:0.84-0.90),0.99(95%CI:0.96-1.00),and 0.9894.Tukey’s multiple comparisons test was used to compare the sensitivities and AUCs of the three diagnostic methods;statistically significant differences were found between the three methods,and LBC combined with SC was superior to both LBC(P<0.05)and SC(P<0.05).The pooled sensitivity and AUC did not change significantly in the sensitivity analysis.CONCLUSION LBC may be sensitive than SC in the cytological diagnosis of pancreatic lesions,however,the superior diagnostic performance of their combination emphasizes their integrated usage in the clinical evaluation of pancreatic lesions.
文摘BACKGROUND: Endoscopic ultrasound-guided fine-needle aspiration cytology was demonstrated to be a useful tool for the diagnosis and staging of pancreaticobiliary neoplastic le- sions. Nonetheless, the diagnostic value of this procedure may be limited by low cellularity of the specimen, contamination of intestinal cells and unfeasibility of ancillary immunocy- tochemical procedures. The present study was to evaluate its usefulness in the diagnosis of neoplastic lesions.
文摘Objective:The aim of the study was to investigate the diagnostic value of fine needle aspiration cytology (FNAC) and its clinical application.Methods:From April 2009 to February 2011,thyroid FNAC were performed in a total of 186 patients with thyroid nodule or mass in our hospital and 78 of those 186 patients subsequently underwent thyroidectomy.The FNAC findings were compared with the results of the corresponding histological diagnosis.Results:The results of thyroid FNAC for 186 patients showed that,(1) 166 cases of benign lesions,the detection rate was 89.24% (166/186),including 96 cases of nodular colloid goiter (51.61%),28 cases of simple colloid goiter (15.05%),38 cases of Hashimoto's thyroiditis (HT) (20.43%) and 4 cases of thyroid adenoma (2.15%);(2) 4 cases of suspicious malignant lesion,the detection rate was 2.15% (4/186);(3) 16 cases of malignant tumor,the detection rate was 8.60% (16/186).Seventy eight patients including malignant (16),suspicious malignant (4),HT (20) and nodular colloid goiters (38) cases diagnosed by FNAC were performed operation with thyroidectomy and the postoperative histopathologic results showed that there were 2 cases HT combined thyroid papillary carcinoma in HT 20 cases by FNAC,15 cases of thyroid papillary carcinoma and 1 case of follicular carcinoma in 16 cases of malignant tumor by FNAC and 4 case of thyroid papillary carcinoma in 4 cases of suspicious malignant by FNAC.Conclusion:Thyroid FNAC is a valuable and reliable method for the diagnosis of the thyroid nodules or mass or even most diffuse thyroid diseases.Diagnosis of HT and thyroid papillary carcinoma can be made by thyroid FNAC.There was larger hint value for nodular colloid goiter and simple colloid goiter according to thyroid FNAC.
文摘Objective: To evaluate the accuracy of these two methods and focus on the analysis and management of the false-negative cases. Methods: Results of full field digital mammography (FFDM) and fine needle aspiration cytology (FNAC) were obtained and analyzed from a consecutive of 102 women with palpable breast masses, results were correlated with the histopathological findings. Results: Of the 102 cases, malignancy was confirmed in 43 cases (42.16%) by final pathological examination, the sensitivity and specificity of cancer detection with FNA cytology was 90.7% (39/43) and 89.8% (53/59), re- spectively, the whole accuracy was 90.2% (92/102), with a positive predictive value of 86.7% (39/45) and a negative predictive value of 93.0% (53/57). FFDM gave a sensitivity of 88.4% (38/43), specificity of 83.1% (49/59), and whole accuracy 85.3% (87/102), the positive predictive value and negative predictive value was 79.2% (38/48) and 90.7% (49/54), respectively. All the FNAC-negative cancer cases were suggestive of malignancy by FFDM findings, however, the benign cases which present as equivocal finding by FNA cytology, could not be ruled out the presence of malignancy. Conclusion: FNAC and FFDM both are accurate, effective and economical diagnostic modalities, combined use of these two methods can reduced the misdiag- nosis rate of breast masses.
文摘This study examined cells contained in needles used for the collection of breast fine needle aspirates for the detection of malignant cells trapped in the needles. Remnants of cells contained in 50 needles used for the collection of scanty breast fine needle aspirates were examined by the liquid based cytology technique and compared with the conventional cytological technique of specimens in the corresponding syringes. The breast specimens were collected with clean sterile needles attached to the syringes. Smears were made and stained by the conventional method. The needles were removed from the syringes and a fixative was withdrawn into the syringes and the syringes were recapped with the needles. The fixative containing the specimen was then completely discharged into a centrifuge tube through the needles and treated by the liquid based cytology technique. The study revealed that cells were found trapped in all the needles used for the collection of breast FNA. 6% of them were positive for malignancy, similar to results obtained in the conventional method. Needles used for the collection of breast FNA should be examined before malignancy is completely ruled out particularly in extremely scanty specimens with a clinical suspicion of malignancy.
文摘BACKGROUND:Endoscopic ultrasound-guided fine needle aspiration(EUS-FNA) has become a crucial diagnostic technique for pancreatic malignancies.The specimen obtained by EUS-FNA can be prepared for either cytological or histological examinations.This study was to compare diagnostic performance of cytological and histological preparations using EUSFNA in the same lesions when pancreatic malignancies were suspected.METHODS:One hundred and eighteen patients who underwent EUS-FNA for suspected pancreatic malignancies were consecutively enrolled.All procedures were conducted by a single echoendoscopist under the same conditions.Four adequate preparations were obtained by 22-gauge needles with 20 to-and-fro movements for each pass.The 4 preparations included 2 cytological and 2 histological specimens.The pathologic reviews of all specimens were conducted independently by a single experienced cytopathologist.Sensitivity,specificity,and accuracy of the 2 preparations were compared.RESULTS:The enrolled patients consisted of 62 males(52.5%),with the mean age of 64.6±10.5 years.Surgery was performed in 23(19.5%) patients.One hundred and sixteen(98.3%) lesions were classified as malignant,while 2(1.7%) were benign.Sensitivity of cytology and histology were 87.9% and 81.9%,respectively,with no significant difference(P=0.190).Accuracy was also not significantly different.Cytological preparation was more sensitive when the size of lesion was <3 cm(86.7% vs 68.9%,P=0.033).CONCLUSIONS:Our results suggested that the diagnostic performances of cytological and histological preparations are not significantly different for the diagnosis of pancreatic malignancies.However,cytological preparation might be more sensitive for pancreatic lesions <3 cm.
文摘The role of endoscopic ultrasound(EUS) in evaluating pancreatic pathology has been well documented from the beginning of its clinical use. High spatial resolution and the close proximity to the evaluated organs within the mediastinum and abdominal cavity allow detection of small focal lesions and precise tissue acquisition from suspected lesions within the reach of this method. Fine needle aspiration(FNA) is considered of additional value to EUS and is performed to obtain tissue diagnosis. Tissue acquisition from suspected lesions for cytological or histological analysis allows, not only the differentiation between malignant and non-malignant lesions, but, in most cases, also the accurate distinction between the various types of malignant lesions. It is well documented that the best results are achieved only if an adequate sample is obtained for further analysis, if the material is processed in an appropriate way, and if adequate ancillary methods are performed. This is a multi-step process and could be quite a challenge in some cases. In this article, we discuss the technical aspects of tissue acquisition by EUS-guided-FNA(EUS-FNA), as well as the role of an on-site cytopathologist, various means of specimen processing, and the selection of the appropriate ancillary method for providing an accurate tissue diagnosis and maximizing the yield of this method. The main goal of this review is to alert endosonographers, not only to the different possibilities of tissue acquisition, namely EUS-FNA, but also to bring to their attention the importance of proper sample processing in the evaluation of various lesions in the gastrointestinal tract and other accessible organs. All aspects of tissue acquisition(needles, suction, use of stylet, complications, etc.) have been well discussed lately. Adequate tissue samples enable comprehensive diagnoses, which answer the main clinical questions, thus enabling targeted therapy.
文摘Endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNA) is a useful procedure that enables reliable pathological diagnoses of pancreatobiliary diseases, subepithelial lesions, and swollen lymph nodes. In recent years, a pathological diagnosis based on EUS-FNA has made it possible to provide accurate treatment methods not only in these fields, but also in respiratory organs and otorhinolaryngology. This review discusses the latest topics pertaining to EUS-FNA as well as procedural tips.
文摘AIM To compare the aspiration needle(AN) and core biopsy needle(PC) in endoscopic ultrasound-guided fine needle aspiration(EUS-FNA) of abdominal masses.METHODS Consecutive patients referred for EUS-FNA were included in this prospective single-center trial. Each patient underwent a puncture of the lesion with both standard 22-gauge(G) AN(Echo Tip Ultra; Cook Medical, Bloomington, Indiana, United States) and the novel 22 G PC(Echo Tip Pro Core; Cook Medical, Bloomington, Indiana, United States) in a randomized fashion; histology was attempted in the PC group only. The main study endpoint was the overall diagnostic accuracy, including the contribution of histology to the final diagnosis. Secondary outcome measures included material adequacy, number of needle passes, and complications.RESULTS Fifty six consecutive patients(29 men; mean age 68 years) with pancreatic lesions(n = 38), lymphadenopathy(n = 13), submucosal tumors(n = 4), or others lesions(n = 1) underwent EUS-FNA using both of the needles in a randomized order. AN and PC reached similar overall results for diagnostic accuracy(AN: 88.9 vs PC: 96.1, P = 0.25), specimen adequacy(AN: 96.4% vs PC: 91.1%, P = 0.38), mean number of passes(AN: 1.5 vs PC: 1.7, P = 0.14), mean cellularity score(AN: 1.7 vs PC: 1.1, P = 0.058), and complications(none). A diagnosis on the basis of histology was achieved in the PC group in 36(64.3%) patients, and in 2 of those as the sole modality. In patients with available histology the mean cellularity score was higher for AN(AN: 1.7 vs PC: 1.0, P = 0.034); no other differences were of statistical significance.CONCLUSION Both needles achieved high overall diagnostic yields and similar performance characteristics for cytological diagnosis; histological analysis was only possible in 2/3 of cases with the new needle.
文摘AIM: To evaluate the diagnostic accuracy of histological evaluation of pancreatic tissue samples obtained by a modified method for recovering and processing the endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) material in the differential diagnosis of pancreatic solid masses. METHODS: Sixty-two consecutive patients with pancreatic masses were prospectively studied. EUS was performed by the linear scanning Pentax FG-38UX echoendoscope. Three FNAs (22G needle) were carried out during each procedure. The materials obtained with first and second punctures were processed for cytological study. Haterials of the third puncture were recovered into 10% formol solution by careful injection of saline solution through the needle, and processed for histological study. RESULTS: Length of the core specimen obtained for histological analysis was 6.5±5.3 mm (range 1-22 mm). Cytological and histological samples were considered as adequate in 51 (82.3%) and 52 cases (83.9%), respectively. Overall sensitivity of both pancreatic cytology and histology for diagnosis of malignancy was 68.4%. Conbary to cytology, histology was able to diagnose tumours other than adenocarcinomas, and all cases of inflammatory masses. Combination of cytology and histology allowed obtaining an adequate sample in 56 cases (90.3%), with a global sensitivity of 84.21%, specificity of 100% and an overall accuracy of 90.32%. The complication rate was 1.6%.CONCLUSION: Adequate pancreatic core specimens for histological examination can be obtained by EUS-guided FNA. This technique is mainly useful for the diagnosis of different types of pancreatic tumours and evaluation of benign diseases.
文摘Since its introduction,endoscopic ultrasound(EUS)guided fine needle aspiration and fine needle biopsy have become an indispensable tool for the diagnosis of lesions within the gastrointestinal tract and surrounding organs.It has proved to be an effective diagnostic method with high accuracy and low complication rates.Several factors can influence the accuracy and the diagnostic yield of this procedure including experience of the endosonographer,availability of onsite cytopathology services,the method of cytopathology preparation,the location and physical characteristics of the lesion,sampling techniques and the type and size of the needle used.In this review we will outline the recent studies evaluating EUS-guided tissue acquisition and will provide practical recommendations to maximize tissue yield.
文摘AIM To compare the accuracy of endoscopic ultra-sonography(EUS) 19 G core biopsies and 22 G core biopsies in diagnosing the correct etiology for a solid mass.METHODS Articles were searched in Medline, Pub Med, and Ovid journals. Pooling was conducted by both fixed and random effects models. RESULTS Initial search identified 4460 reference articles for 19 G and 22 G, of these 670 relevant articles were selected and reviewed. Data was extracted from 6 studies for 19G(n = 289) and 16 studies for 22G(n = 592) which met the inclusion criteria. EUS 19 G core biopsies had a pooled sensitivity of 91.6%(95%CI: 87.1-95.0) and pooled specificity of 95.9%(95%CI: 88.6-99.2), whereas EUS 22 G had a pooled sensitivity of 83.3%(95%CI: 79.7-86.6) and pooled specificity of 64.3%(95%CI: 54.7-73.1). The positive likelihood ratio of EUS 19 G core biopsies was 9.08(95%CI: 1.12-73.66) and EUS 22 G core biopsies was 1.99(95%CI: 1.09-3.66).The negative likelihood ratio of EUS 19 G core biopsies was 0.12(95%CI: 0.07-0.24) and EUS 22 G core biopsies was 0.25(95%CI: 0.14-0.41). The diagnostic odds ratio was 84.74(95%CI: 18.31-392.26) for 19 G core biopsies and 10.55(95% CI: 3.29-33.87) for 22 G needles. CONCLUSION EUS 19 G core biopsies have an excellent diagnostic value and seem to be better than EUS 22 G biopsies in detecting the correct etiology for a solid mass.