BACKGROUND Reconstruction of the pelvic ring anatomy in unstable anterior pelvic ring injuries is a significant step to reduce the mortality rate associated with these injuries efficiently.There is a debate on using e...BACKGROUND Reconstruction of the pelvic ring anatomy in unstable anterior pelvic ring injuries is a significant step to reduce the mortality rate associated with these injuries efficiently.There is a debate on using either an anterior subcutaneous pelvis internal fixator(INFIX)or an anterior supra-acetabular external fixator(EXFIX)to manage an unstable anterior pelvic ring fracture.AIM To compare the functional and radiological outcomes and complications of INFIX vs EXFIX in managing unstable pelvic ring injuries.METHODS A prospective cohort study included 54 patients with unstable pelvic ring fractures.The patients were divided into two groups;the INFIX group,in which 30 cases were fixed by INFIX,and the EXFIX group,in which 24 patients were treated by EXFIX.The average age in the EXFIX group was 31.17 years(16-57 years),while in the INFIX group,it was 34.5 years(17-53 years).The study included 20(66.7%)males and 10(33.3%)females in the INFIX group and 10(41.7%)males and 14(58.3%)females in the EXFIX group.The radiological outcomes were evaluated using Matta and Tornetta's score,and the functional outcomes using the Majeed score.RESULTS The results revealed a statistically significant difference between both groups(P=0.013)regarding radiological outcomes,according to Matta and Tornetta's score in favor of the INFIX group.Sitting,standing,and walking abilities were measured at a 3-mo follow-up visit using Majeed score modules.It was significantly better among the INFIX group than the EXFIX group in all three modules.At the final follow-up,both groups had no statistically significant difference according to the Majeed score;92.35 in the INFIX group and 90.99 in the EXFIX group(P=0.513).A lower surgical site infection rate was noticed in the INFIX group(P=0.007).CONCLUSION Anterior subcutaneous pelvis INFIX is associated with better radiological outcomes and a lower infection rate than anterior supra-acetabular EXFIX in managing patients with unstable anterior pelvic ring fractures.展开更多
Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic...Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic outcomes of comminuted intra-articular DRFs treated with a dynamic external fixator combined with a volar locking plate (VLP). Methods: Eleven patients (mean age, 61 years) with comminuted intra-articular DRFs were treated with a dynamic type of external fixator combined with a VLP. Following reduction and fixation with a VLP, the dynamic external fixator was applied and the distal ball joint of the fixator was aligned with the lunate-capitate line. The ball joint was unlocked approximately 2 weeks after surgery to allow wrist mobilization. The fixator was removed 3 - 6 weeks (mean, 5 weeks) after surgery. Consequently, clinical and radiographic assessments were carried out at the final follow-up. Results: At the final follow-up, the mean range values of wrist extension and flexion were 76°and 64°, respectively. Compared with the contralateral side, the mean grip strength was 84%. The mean Modified Mayo Wrist Score and the Disabilities of the Arm, Shoulder and Hand score were 88 and 9, respectively. No significant differences in the radiographic parameters exist between after surgery and final follow-up. Conclusions: This study indicated that the dynamic wrist fixator combined with a VLP is effective for the treatment of AO type C3 DRFs.展开更多
A stress analysis of the Sarafix external fixator design was performed using finite element analysis (FEA) and experimental tensometric measurements. The study was conducted at one of the Sarafix fixator configurati...A stress analysis of the Sarafix external fixator design was performed using finite element analysis (FEA) and experimental tensometric measurements. The study was conducted at one of the Sarafix fixator configurations that have a clinical application in the treatment of tibia fractures. The intensity of principal and yon Mises stresses generated at two measuring points (MP) on the fixator connecting rod were monitored and analyzed during the testing on axial compression on the fixator design and its finite element model (FEM). The 3D geometrical and FEM model of the fixator was formed using the computer aided design/computer aided engineering (CAD/CAE) software system CATIA. Verification of the results for the dominant principal stresses obtained from FEA was carried out through tensometric measurements. The measuring chain consisted of strain gauges connected into two Wheatstone half-bridges, digital measuring amplifier system and a computer with software for acquisition and monitoring of measurement results. A quite good agreement was observed between the results obtained on the basis of FEA and results of experimental tensometric analysis,展开更多
Objective To evaluate effects of manipulative reduction,dynamic external fixator combined with limited internal fixation for the treatment of Pilon fractures.Methods From January 2007 to June 2009,manipulative reducti...Objective To evaluate effects of manipulative reduction,dynamic external fixator combined with limited internal fixation for the treatment of Pilon fractures.Methods From January 2007 to June 2009,manipulative reduction,dynamic external展开更多
Objective To evaluate the clinical effects of Ilizarov external fixator for maluninon of obsolete calcaneal fracture of Stephen Type Ⅲ.Methods From July 2006 to February 2009,25 patients suffering from maluninon of o...Objective To evaluate the clinical effects of Ilizarov external fixator for maluninon of obsolete calcaneal fracture of Stephen Type Ⅲ.Methods From July 2006 to February 2009,25 patients suffering from maluninon of obsolete calcaneal展开更多
The Ortho-SUV frame,a novel external fixator,can effectively treat limb deformities and fractures.Its kinematics is used when it is necessary to achieve bone movements with high precision.In this work,the kinematics m...The Ortho-SUV frame,a novel external fixator,can effectively treat limb deformities and fractures.Its kinematics is used when it is necessary to achieve bone movements with high precision.In this work,the kinematics model of the Ortho-SUV frame is established by six pose parameters,and its forward and inverse solutions are given.There is no need to solve nonlinear high-coupling equations with trigonometric functions in this solution method due to its special structure.By numerical examples and simulated orthopedic experiment of tibial fracture,the correctness and accuracy of the kinematics model and its solutions are verified.Besides,on the basis of kinematics analysis,the position workspace and orientation workspace of the Ortho-SUV frame are simulated in Matlab,which can help surgeons choose suitable device dimensions.The kinematics analysis provides a theoretical basis for the Ortho-SUV frame to be used in orthopedic treatment.展开更多
Introduction: The Hybrid External Fixator combines the advantages of the monolateral pin fixators and the circular Ilizarov wire fixators. Principle of early motion has been touted as the functional savior of major in...Introduction: The Hybrid External Fixator combines the advantages of the monolateral pin fixators and the circular Ilizarov wire fixators. Principle of early motion has been touted as the functional savior of major intra articular injuries in application of hybrid external fixation. Materials & Methodology: 48 patients were considered for the study with tibial fractures admitted in Mamata General Hospital from May 2011 to May 2013. Results: The union and functional outcome of hybrid external fixator in simple and complex proximal and distal metaphyseal fractures of tibia in adults was evaluated at our centre. The fractures of the proximal tibia united with an average of 13.3 weeks (12 - 16 weeks). The fractures of the distal tibia united with an average of 14.42 weeks (13 - 22 weeks) with minimal complications. Conclusion: Our study shows high satisfaction rate after fixation, provides adequate stability and allows early motion of the joint. It is also effective in extra articular fractures occurring within 5 cm of the joint as the IM nails often do not provide enough stability and plating requires extensive soft tissue dissection.展开更多
The objective of the present study was to investigate our novel methods for the repair of massive cartilage defects by joint distraction and motion using an external fixator. In this study, we used a rabbit model of m...The objective of the present study was to investigate our novel methods for the repair of massive cartilage defects by joint distraction and motion using an external fixator. In this study, we used a rabbit model of massive articular cartilage defect in order to evaluate the effectiveness of using joint distraction and motion with a ring-type external fixator. This external fixator has a hinged joint with a center of rotation along the femoral transepicondylar axis, which allows the knee joint to freely flex and extend. Mesenchymal cells from bone marrow, induced by spongialization, were differentiated into mature chondrocytes and formed hyaline-like cartilage as a result of joint distraction and movement. The transplantation of autologous cells expanded from bone-marrow-derived mesenchymal cells, concentrated autologous bone marrow aspirate, and concentrated autologous peripheral blood cells were all effective in promoting cartilage repair. The quality of the cartilage after long-term joint distraction for 6 months was inferior to that after 12 weeks. In general, weight bearing on the regenerated cartilage promoted cartilage repair, although this effect differed based on when gradual weight bearing was begun. Specifically, gradual weight bearing beginning at 9 weeks produced superior results to that beginning at 6 weeks. Our methods provide an optimal environment for cartilage regeneration.展开更多
BACKGROUND High tibial osteotomy(HTO)is a well-known procedure for the correction of knee varus.The purpose of this study was to compare the radiological results and accuracy of deformity correction performed using tw...BACKGROUND High tibial osteotomy(HTO)is a well-known procedure for the correction of knee varus.The purpose of this study was to compare the radiological results and accuracy of deformity correction performed using two different techniques:acute opening wedge correction using a plate and gradual correction with a monolateral external fixator.AIM To compare of the radiological results of two different techniques:acute opening wedge correction(a plate and screw)and gradual correction(external fixator).METHODS A total of 43 patients with plates and 36 patients with external fixators were included.All patients had moderate uniplanar varus deformities.We measured radiographic parameters,including the mechanical axis deviation(MAD),medial proximal tibial angle(MPTA),Caton-Deschamps Index(CDI),posterior proximal tibial angle,and joint line obliquity angle(JLOA).The accuracy of MAD correction was calculated based on a correction goal of neutral or overcorrection for medial compartment arthritis.RESULTS Demographics including age,body mass index,sex,and preoperative deformities were similar between the groups.The MAD significantly improved from 23.6 mm medial to the midline(SD=8.2 mm)to 6.9 mm lateral to the midline(SD=5.4 mm)(P<0.001).The accuracy of MAD correction did not differ between the groups and was 96.1%(SD=8.1%)in the plate group and 98.2%(SD=5.2%)in the external fixator group(P=0.18).The MPTA significantly improved from 83.9°(SD=2.9°)to 90.9°(SD=3.3°)(P<0.001),and the change was similar between the groups.Differences were noted in patella height,with a CDI change of-19.2%(SD=13.7%)and 3.1%(SD=8.0%)for the plate and external fixator groups,respectively(P<0.001).The change in JLOA was 1.6 degrees(SD=1.1 degrees)and 0.9 degrees(SD=0.9 degrees)for the plate and external fixator groups,respectively(P=0.04).CONCLUSION Reliable correction of moderate varus alignment was achieved with both the acute opening wedge technique with a plate and the gradual monolateral external fixator technique.The patellar height decreased with the open wedge plate technique.Joint line obliquity decreased to a greater degree with the open wedge plate technique,perhaps as a result of medial collateral ligament release.The appropriate technique should be selected based on surgeon and patient preferences;however,external fixation may be a better choice when the preservation of patellar height is deemed important.展开更多
Objective: Unicameral bone cyst is a nonneoplasticbone lesion characterized by its tenacity and risk ofrecurrence. Pathological fracture is common and is often the presenting symptom. The objective of the present stud...Objective: Unicameral bone cyst is a nonneoplasticbone lesion characterized by its tenacity and risk ofrecurrence. Pathological fracture is common and is often the presenting symptom. The objective of the present study was to evaluate the results of hybrid external fixator for thetreatment of a unicameral bone cyst with a pathologicalfracture. Methods: Hybrid external fixator for thetreatment of a unicameral bone cyst was performed intwelve patients. These patients presented with a pathological fracture and were managed immediately with hybridexternal fixator, of whom four had been managedconservatively at other clinics before they were referred toour department. The cyst was located in the proximalhumerus in all patients. The mean age of the patients at the time of surgery was 8.7 years, and the mean duration offollow-up was 32.6 months. Radiographic evaluation wasperformed according to the criteria of Capanna et al., andthe cyst was classified as completely healed, healed withresidual radiolucency (osteolysis), recurred, or having noresponse. Results: The healing period ranged from three to eight months. Eight cysts healed completely, and threehealed with residual radiolucent areas visible onradiographs. There was recurrence of one cyst that hadhealed with residual radiolucency. All of the cysts in thepresent study responded to treatment. A modulation ofhybrid external fixator was necessary in three patients, asthe bars had become too short after bone growth or the pins had been loose. No major complications were observed.Conclusion: Hybrid external fixator provides earlystability, which allows early mobilization and thus obviates the need for a plaster cast. This method of treatment alsoallows for an early return to normal activity.展开更多
Four tibiae removed from 30-40 years males, who died of accidents in less than 12 hours, were os- teomized at medium part. Then these tibiae were fixed by an unilateral hooked-sulcated external fixator (UHSEF), and th...Four tibiae removed from 30-40 years males, who died of accidents in less than 12 hours, were os- teomized at medium part. Then these tibiae were fixed by an unilateral hooked-sulcated external fixator (UHSEF), and the bone-fixator system was used as a model of external fixation of tibial fracture. The axial compression, distraction, torsion, antero-posterior and lateral bending rigidly and the strain of the pins were determined in this system. Based on the results, we found that compared with the configuration of four paralled pins, the rigidity of the fan-like configuraton didn’t decrease significantly if the angle between lateral and medium pins was less than 45’. But the reverse was true when the frame separation increased from 5 to 8 cm. What’ more, the pin strain decreased if the rigidity of the system was improved. These data provided a theoretical basis of biomechanics for the improvement of UHSEF.展开更多
After the first research with this technique done by the first author, ten operations on the foot and ankle were performed on five patients (two boys and three girls) suffering from severe club foot deformity all with...After the first research with this technique done by the first author, ten operations on the foot and ankle were performed on five patients (two boys and three girls) suffering from severe club foot deformity all with bilateral foot affection. Their ages ranged from five to fourteen years. All of them were treated by soft tissue release, skin flap (rotational flap), supplemented with Alkhooly external fixator. The follow up period ranged from two to seven years. The results according to Mittal (1987) [1] were excellent in eight feet (80%) and good in two feet (20%).展开更多
Objective: To evaluate the effectiveness of the damage control, in emergency to treat the open tibial pilon fractures with Dolphix? External Fixator Frame(CITIEFFE?, Calderara di Reno, Bologna, Italy). Methods: From J...Objective: To evaluate the effectiveness of the damage control, in emergency to treat the open tibial pilon fractures with Dolphix? External Fixator Frame(CITIEFFE?, Calderara di Reno, Bologna, Italy). Methods: From January 2017 to August 2017, at the Department of Orthopedics and Traumatology of Vito Fazzi Hospital Lecce, we treated 23 open tibial pilon fractures with Dolphix? External Fixator Frame(CITIEFFE?, Calderara di Reno, Bologna, Italy). The evaluation criteria of the case series were: the time needed to assemble the external fixator;the time taked to treat the ankle associated lesions;the time of skin healing;the ankle alignment;the subjective/objective Ovadia and Beals score;and complications. The Endpoint assessment was set at the days of the definitive surgery. Results: The results in terms of alignment, biomechanical stability of the frame, healing of soft tissue, complications were as good as the objective and subjective results according Ovadia and Beals score. Conclusion:Pilon fractures are complex and often present complications;the damage control treatment, in emergency, with Dolphix? External Fixator Frame(CITIEFFE?, Calderara di Reno, Bologna, Italy) permits a stable osteotaxis with minimal soft tissue damage and permit the repair of muscles, blood vessels and nerves with a stable bone and the soft tissue healing with vaccum therapy.展开更多
Let G be a graph. A bipartition of G is a bipartition of V (G) with V (G) = V<sub>1</sub> ∪ V<sub>2</sub> and V<sub>1</sub> ∩ V<sub>2</sub> = ∅. If a bipartition satis...Let G be a graph. A bipartition of G is a bipartition of V (G) with V (G) = V<sub>1</sub> ∪ V<sub>2</sub> and V<sub>1</sub> ∩ V<sub>2</sub> = ∅. If a bipartition satisfies ∥V<sub>1</sub>∣ - ∣V<sub>2</sub>∥ ≤ 1, we call it a bisection. The research in this paper is mainly based on a conjecture proposed by Bollobás and Scott. The conjecture is that every graph G has a bisection (V<sub>1</sub>, V<sub>2</sub>) such that ∀v ∈ V<sub>1</sub>, at least half minuses one of the neighbors of v are in the V<sub>2</sub>;∀v ∈ V<sub>2</sub>, at least half minuses one of the neighbors of v are in the V<sub>1</sub>. In this paper, we confirm this conjecture for some bipartite graphs, crown graphs and windmill graphs.展开更多
School-based universal screening for behavioral/emotional risk is a necessary first step to providing services in an educational setting for students with emotional and behavioral disorders (EBDs). Psychometric proper...School-based universal screening for behavioral/emotional risk is a necessary first step to providing services in an educational setting for students with emotional and behavioral disorders (EBDs). Psychometric properties are critical to making decisions about choosing a screening instrument. The purpose of the present study was to examine the psychometric properties of the student risk screening scale for internalizing and externalizing behaviors (SRSS-IE). Participants included 3145 students and their teachers. Item-level analyses of the current sample supported the retention of all items. The internal consistency of the SRSS items ranged from 0.83 to 0.85. Convergent validity between the SRSS-IE and a well-established screening tool, the strength and difficulties questionnaire (SDQ), was found for the total score (r = 0.70). Additionally, the results of this study demonstrate strong social validity, suggesting the SRSS-IE to be a useful and functional screening tool. We conclude that the SRSS-IE is a valid and reliable instrument for assessing the level of emotional and behavioral difficulties among elementary students.展开更多
Irritable bowel syndrome(IBS-D)with diarrhea is a common gastrointestinal functional disease in clinical practice,which seriously affects the quality of life of patients.Cur‐rently,Western medicine has poor therapeut...Irritable bowel syndrome(IBS-D)with diarrhea is a common gastrointestinal functional disease in clinical practice,which seriously affects the quality of life of patients.Cur‐rently,Western medicine has poor therapeutic effects,while traditional Chinese medi‐cine has unique advantages in relieving IBS-D symptoms and preventing recurrence.In recent years,especially with external treatment of traditional Chinese medicine,it has become a new treatment direction in clinical practice and has achieved good therapeutic effects.This article will provide a review of recent research on the treatment of IBS-D using traditional Chinese medicine external treatment methods.展开更多
This paper aims to enhance the compression capacity of underwater cylindrical shells by adopting the corrugated sandwich structure of cuttlebone.The cuttlebone suffers uniaxial external compression,while underwater cy...This paper aims to enhance the compression capacity of underwater cylindrical shells by adopting the corrugated sandwich structure of cuttlebone.The cuttlebone suffers uniaxial external compression,while underwater cylindrical shells are in a biaxial compressive stress state.To suit the biaxial compressive stress state,a novel bidirectional corrugated sandwich structure is proposed to improve the bearing capacity of cylindrical shells.The static and buckling analysis for the sandwich shell and the unstiffened cylindrical shell with the same volume-weight ratio are studied by numerical simulation.It is indicated that the proposed sandwich shell can effectively reduce the ratio between circumferential and axial stress from 2 to 1.25 and improve the critical buckling load by about 1.63 times.Numerical simulation shows that optimizing and adjusting the structural parameters could significantly improve the advantage of the sandwich shell.Then,the hydrostatic pressure tests for shell models fabricated by 3D printing are carried out.According to the experimental results,the overall failure position of the sandwich shell is at the center part of the sandwich shell.It has been found the average critical load of the proposed sandwich shell models exceeds two times that of the unstiffened shell models.Hence,the proposed bio-inspired bidirectional corrugated sandwich structure can significantly enhance the pressure resistance capability of cylindrical shells.展开更多
The instability of plasma waves in the channel of field-effect transistors will cause the electromagnetic waves with THz frequency.Based on a self-consistent quantum hydrodynamic model,the instability of THz plasmas w...The instability of plasma waves in the channel of field-effect transistors will cause the electromagnetic waves with THz frequency.Based on a self-consistent quantum hydrodynamic model,the instability of THz plasmas waves in the channel of graphene field-effect transistors has been investigated with external magnetic field and quantum effects.We analyzed the influence of weak magnetic fields,quantum effects,device size,and temperature on the instability of plasma waves under asymmetric boundary conditions numerically.The results show that the magnetic fields,quantum effects,and the thickness of the dielectric layer between the gate and the channel can increase the radiation frequency.Additionally,we observed that increase in temperature leads to a decrease in both oscillation frequency and instability increment.The numerical results and accompanying images obtained from our simulations provide support for the above conclusions.展开更多
The effect of slow shot speed on externally solidified crystal(ESC),porosity and tensile property in a newly developed high-pressure die-cast Al-Si alloy was investigated by optical microscopy(OM),scanning electron mi...The effect of slow shot speed on externally solidified crystal(ESC),porosity and tensile property in a newly developed high-pressure die-cast Al-Si alloy was investigated by optical microscopy(OM),scanning electron microscopy(SEM)and laboratory computed tomography(CT).Results showed that the newly developed AlSi9MnMoV alloy exhibited improved mechanical properties when compared to the AlSi10MnMg alloy.The AlSi9MnMoV alloy,which was designed with trace multicomponent additions,displays a notable grain refining effect in comparison to the AlSi10MnMg alloy.Refining elements Ti,Zr,V,Nb,B promote heterogeneous nucleation and reduce the grain size of primaryα-Al.At a lower slow shot speed,the large ESCs are easier to form and gather,developing into the dendrite net and net-shrinkage.With an increase in slow shot speed,the size and number of ESCs and porosities significantly reduce.In addition,the distribution of ESCs is more dispersed and the net-shrinkage disappears.The tensile property is greatly improved by adopting a higher slow shot speed.The ultimate tensile strength is enhanced from 260.31 MPa to 290.31 MPa(increased by 11.52%),and the elongation is enhanced from 3.72%to 6.34%(increased by 70.52%).展开更多
Recently,the newly synthesized septuple-atomic layer two-dimensional(2D)material MoSi_(2)N_(4)(MSN)has attracted attention worldwide.Our work delves into the effect of vacancies and external electric fields on the ele...Recently,the newly synthesized septuple-atomic layer two-dimensional(2D)material MoSi_(2)N_(4)(MSN)has attracted attention worldwide.Our work delves into the effect of vacancies and external electric fields on the electronic properties of the MSN/graphene(Gr)heterostructure using first-principles calculation.We find that four types of defective structures,N-in,N-out,Si and Mo vacancy defects of monolayer MSN and MSN/Gr heterostructure are stable in air.Moreover,vacancy defects can effectively modulate the charge transfer at the interface of the MSN/Gr heterostructure as well as the work function of the pristine monolayer MSN and MSN/Gr heterostructure.Finally,the application of an external electric field enables the dynamic switching between n-type and p-type Schottky contacts.Our work may offer the possibility of exceeding the capabilities of conventional Schottky diodes based on MSN/Gr heterostructures.展开更多
文摘BACKGROUND Reconstruction of the pelvic ring anatomy in unstable anterior pelvic ring injuries is a significant step to reduce the mortality rate associated with these injuries efficiently.There is a debate on using either an anterior subcutaneous pelvis internal fixator(INFIX)or an anterior supra-acetabular external fixator(EXFIX)to manage an unstable anterior pelvic ring fracture.AIM To compare the functional and radiological outcomes and complications of INFIX vs EXFIX in managing unstable pelvic ring injuries.METHODS A prospective cohort study included 54 patients with unstable pelvic ring fractures.The patients were divided into two groups;the INFIX group,in which 30 cases were fixed by INFIX,and the EXFIX group,in which 24 patients were treated by EXFIX.The average age in the EXFIX group was 31.17 years(16-57 years),while in the INFIX group,it was 34.5 years(17-53 years).The study included 20(66.7%)males and 10(33.3%)females in the INFIX group and 10(41.7%)males and 14(58.3%)females in the EXFIX group.The radiological outcomes were evaluated using Matta and Tornetta's score,and the functional outcomes using the Majeed score.RESULTS The results revealed a statistically significant difference between both groups(P=0.013)regarding radiological outcomes,according to Matta and Tornetta's score in favor of the INFIX group.Sitting,standing,and walking abilities were measured at a 3-mo follow-up visit using Majeed score modules.It was significantly better among the INFIX group than the EXFIX group in all three modules.At the final follow-up,both groups had no statistically significant difference according to the Majeed score;92.35 in the INFIX group and 90.99 in the EXFIX group(P=0.513).A lower surgical site infection rate was noticed in the INFIX group(P=0.007).CONCLUSION Anterior subcutaneous pelvis INFIX is associated with better radiological outcomes and a lower infection rate than anterior supra-acetabular EXFIX in managing patients with unstable anterior pelvic ring fractures.
文摘Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic outcomes of comminuted intra-articular DRFs treated with a dynamic external fixator combined with a volar locking plate (VLP). Methods: Eleven patients (mean age, 61 years) with comminuted intra-articular DRFs were treated with a dynamic type of external fixator combined with a VLP. Following reduction and fixation with a VLP, the dynamic external fixator was applied and the distal ball joint of the fixator was aligned with the lunate-capitate line. The ball joint was unlocked approximately 2 weeks after surgery to allow wrist mobilization. The fixator was removed 3 - 6 weeks (mean, 5 weeks) after surgery. Consequently, clinical and radiographic assessments were carried out at the final follow-up. Results: At the final follow-up, the mean range values of wrist extension and flexion were 76°and 64°, respectively. Compared with the contralateral side, the mean grip strength was 84%. The mean Modified Mayo Wrist Score and the Disabilities of the Arm, Shoulder and Hand score were 88 and 9, respectively. No significant differences in the radiographic parameters exist between after surgery and final follow-up. Conclusions: This study indicated that the dynamic wrist fixator combined with a VLP is effective for the treatment of AO type C3 DRFs.
文摘A stress analysis of the Sarafix external fixator design was performed using finite element analysis (FEA) and experimental tensometric measurements. The study was conducted at one of the Sarafix fixator configurations that have a clinical application in the treatment of tibia fractures. The intensity of principal and yon Mises stresses generated at two measuring points (MP) on the fixator connecting rod were monitored and analyzed during the testing on axial compression on the fixator design and its finite element model (FEM). The 3D geometrical and FEM model of the fixator was formed using the computer aided design/computer aided engineering (CAD/CAE) software system CATIA. Verification of the results for the dominant principal stresses obtained from FEA was carried out through tensometric measurements. The measuring chain consisted of strain gauges connected into two Wheatstone half-bridges, digital measuring amplifier system and a computer with software for acquisition and monitoring of measurement results. A quite good agreement was observed between the results obtained on the basis of FEA and results of experimental tensometric analysis,
文摘Objective To evaluate effects of manipulative reduction,dynamic external fixator combined with limited internal fixation for the treatment of Pilon fractures.Methods From January 2007 to June 2009,manipulative reduction,dynamic external
文摘Objective To evaluate the clinical effects of Ilizarov external fixator for maluninon of obsolete calcaneal fracture of Stephen Type Ⅲ.Methods From July 2006 to February 2009,25 patients suffering from maluninon of obsolete calcaneal
基金National Key Research & Development Program of China(No.2017YFB1302901)
文摘The Ortho-SUV frame,a novel external fixator,can effectively treat limb deformities and fractures.Its kinematics is used when it is necessary to achieve bone movements with high precision.In this work,the kinematics model of the Ortho-SUV frame is established by six pose parameters,and its forward and inverse solutions are given.There is no need to solve nonlinear high-coupling equations with trigonometric functions in this solution method due to its special structure.By numerical examples and simulated orthopedic experiment of tibial fracture,the correctness and accuracy of the kinematics model and its solutions are verified.Besides,on the basis of kinematics analysis,the position workspace and orientation workspace of the Ortho-SUV frame are simulated in Matlab,which can help surgeons choose suitable device dimensions.The kinematics analysis provides a theoretical basis for the Ortho-SUV frame to be used in orthopedic treatment.
文摘Introduction: The Hybrid External Fixator combines the advantages of the monolateral pin fixators and the circular Ilizarov wire fixators. Principle of early motion has been touted as the functional savior of major intra articular injuries in application of hybrid external fixation. Materials & Methodology: 48 patients were considered for the study with tibial fractures admitted in Mamata General Hospital from May 2011 to May 2013. Results: The union and functional outcome of hybrid external fixator in simple and complex proximal and distal metaphyseal fractures of tibia in adults was evaluated at our centre. The fractures of the proximal tibia united with an average of 13.3 weeks (12 - 16 weeks). The fractures of the distal tibia united with an average of 14.42 weeks (13 - 22 weeks) with minimal complications. Conclusion: Our study shows high satisfaction rate after fixation, provides adequate stability and allows early motion of the joint. It is also effective in extra articular fractures occurring within 5 cm of the joint as the IM nails often do not provide enough stability and plating requires extensive soft tissue dissection.
文摘The objective of the present study was to investigate our novel methods for the repair of massive cartilage defects by joint distraction and motion using an external fixator. In this study, we used a rabbit model of massive articular cartilage defect in order to evaluate the effectiveness of using joint distraction and motion with a ring-type external fixator. This external fixator has a hinged joint with a center of rotation along the femoral transepicondylar axis, which allows the knee joint to freely flex and extend. Mesenchymal cells from bone marrow, induced by spongialization, were differentiated into mature chondrocytes and formed hyaline-like cartilage as a result of joint distraction and movement. The transplantation of autologous cells expanded from bone-marrow-derived mesenchymal cells, concentrated autologous bone marrow aspirate, and concentrated autologous peripheral blood cells were all effective in promoting cartilage repair. The quality of the cartilage after long-term joint distraction for 6 months was inferior to that after 12 weeks. In general, weight bearing on the regenerated cartilage promoted cartilage repair, although this effect differed based on when gradual weight bearing was begun. Specifically, gradual weight bearing beginning at 9 weeks produced superior results to that beginning at 6 weeks. Our methods provide an optimal environment for cartilage regeneration.
文摘BACKGROUND High tibial osteotomy(HTO)is a well-known procedure for the correction of knee varus.The purpose of this study was to compare the radiological results and accuracy of deformity correction performed using two different techniques:acute opening wedge correction using a plate and gradual correction with a monolateral external fixator.AIM To compare of the radiological results of two different techniques:acute opening wedge correction(a plate and screw)and gradual correction(external fixator).METHODS A total of 43 patients with plates and 36 patients with external fixators were included.All patients had moderate uniplanar varus deformities.We measured radiographic parameters,including the mechanical axis deviation(MAD),medial proximal tibial angle(MPTA),Caton-Deschamps Index(CDI),posterior proximal tibial angle,and joint line obliquity angle(JLOA).The accuracy of MAD correction was calculated based on a correction goal of neutral or overcorrection for medial compartment arthritis.RESULTS Demographics including age,body mass index,sex,and preoperative deformities were similar between the groups.The MAD significantly improved from 23.6 mm medial to the midline(SD=8.2 mm)to 6.9 mm lateral to the midline(SD=5.4 mm)(P<0.001).The accuracy of MAD correction did not differ between the groups and was 96.1%(SD=8.1%)in the plate group and 98.2%(SD=5.2%)in the external fixator group(P=0.18).The MPTA significantly improved from 83.9°(SD=2.9°)to 90.9°(SD=3.3°)(P<0.001),and the change was similar between the groups.Differences were noted in patella height,with a CDI change of-19.2%(SD=13.7%)and 3.1%(SD=8.0%)for the plate and external fixator groups,respectively(P<0.001).The change in JLOA was 1.6 degrees(SD=1.1 degrees)and 0.9 degrees(SD=0.9 degrees)for the plate and external fixator groups,respectively(P=0.04).CONCLUSION Reliable correction of moderate varus alignment was achieved with both the acute opening wedge technique with a plate and the gradual monolateral external fixator technique.The patellar height decreased with the open wedge plate technique.Joint line obliquity decreased to a greater degree with the open wedge plate technique,perhaps as a result of medial collateral ligament release.The appropriate technique should be selected based on surgeon and patient preferences;however,external fixation may be a better choice when the preservation of patellar height is deemed important.
文摘Objective: Unicameral bone cyst is a nonneoplasticbone lesion characterized by its tenacity and risk ofrecurrence. Pathological fracture is common and is often the presenting symptom. The objective of the present study was to evaluate the results of hybrid external fixator for thetreatment of a unicameral bone cyst with a pathologicalfracture. Methods: Hybrid external fixator for thetreatment of a unicameral bone cyst was performed intwelve patients. These patients presented with a pathological fracture and were managed immediately with hybridexternal fixator, of whom four had been managedconservatively at other clinics before they were referred toour department. The cyst was located in the proximalhumerus in all patients. The mean age of the patients at the time of surgery was 8.7 years, and the mean duration offollow-up was 32.6 months. Radiographic evaluation wasperformed according to the criteria of Capanna et al., andthe cyst was classified as completely healed, healed withresidual radiolucency (osteolysis), recurred, or having noresponse. Results: The healing period ranged from three to eight months. Eight cysts healed completely, and threehealed with residual radiolucent areas visible onradiographs. There was recurrence of one cyst that hadhealed with residual radiolucency. All of the cysts in thepresent study responded to treatment. A modulation ofhybrid external fixator was necessary in three patients, asthe bars had become too short after bone growth or the pins had been loose. No major complications were observed.Conclusion: Hybrid external fixator provides earlystability, which allows early mobilization and thus obviates the need for a plaster cast. This method of treatment alsoallows for an early return to normal activity.
基金This work was supported by Wuhan science & Technolgy Committee
文摘Four tibiae removed from 30-40 years males, who died of accidents in less than 12 hours, were os- teomized at medium part. Then these tibiae were fixed by an unilateral hooked-sulcated external fixator (UHSEF), and the bone-fixator system was used as a model of external fixation of tibial fracture. The axial compression, distraction, torsion, antero-posterior and lateral bending rigidly and the strain of the pins were determined in this system. Based on the results, we found that compared with the configuration of four paralled pins, the rigidity of the fan-like configuraton didn’t decrease significantly if the angle between lateral and medium pins was less than 45’. But the reverse was true when the frame separation increased from 5 to 8 cm. What’ more, the pin strain decreased if the rigidity of the system was improved. These data provided a theoretical basis of biomechanics for the improvement of UHSEF.
文摘After the first research with this technique done by the first author, ten operations on the foot and ankle were performed on five patients (two boys and three girls) suffering from severe club foot deformity all with bilateral foot affection. Their ages ranged from five to fourteen years. All of them were treated by soft tissue release, skin flap (rotational flap), supplemented with Alkhooly external fixator. The follow up period ranged from two to seven years. The results according to Mittal (1987) [1] were excellent in eight feet (80%) and good in two feet (20%).
文摘Objective: To evaluate the effectiveness of the damage control, in emergency to treat the open tibial pilon fractures with Dolphix? External Fixator Frame(CITIEFFE?, Calderara di Reno, Bologna, Italy). Methods: From January 2017 to August 2017, at the Department of Orthopedics and Traumatology of Vito Fazzi Hospital Lecce, we treated 23 open tibial pilon fractures with Dolphix? External Fixator Frame(CITIEFFE?, Calderara di Reno, Bologna, Italy). The evaluation criteria of the case series were: the time needed to assemble the external fixator;the time taked to treat the ankle associated lesions;the time of skin healing;the ankle alignment;the subjective/objective Ovadia and Beals score;and complications. The Endpoint assessment was set at the days of the definitive surgery. Results: The results in terms of alignment, biomechanical stability of the frame, healing of soft tissue, complications were as good as the objective and subjective results according Ovadia and Beals score. Conclusion:Pilon fractures are complex and often present complications;the damage control treatment, in emergency, with Dolphix? External Fixator Frame(CITIEFFE?, Calderara di Reno, Bologna, Italy) permits a stable osteotaxis with minimal soft tissue damage and permit the repair of muscles, blood vessels and nerves with a stable bone and the soft tissue healing with vaccum therapy.
文摘Let G be a graph. A bipartition of G is a bipartition of V (G) with V (G) = V<sub>1</sub> ∪ V<sub>2</sub> and V<sub>1</sub> ∩ V<sub>2</sub> = ∅. If a bipartition satisfies ∥V<sub>1</sub>∣ - ∣V<sub>2</sub>∥ ≤ 1, we call it a bisection. The research in this paper is mainly based on a conjecture proposed by Bollobás and Scott. The conjecture is that every graph G has a bisection (V<sub>1</sub>, V<sub>2</sub>) such that ∀v ∈ V<sub>1</sub>, at least half minuses one of the neighbors of v are in the V<sub>2</sub>;∀v ∈ V<sub>2</sub>, at least half minuses one of the neighbors of v are in the V<sub>1</sub>. In this paper, we confirm this conjecture for some bipartite graphs, crown graphs and windmill graphs.
文摘School-based universal screening for behavioral/emotional risk is a necessary first step to providing services in an educational setting for students with emotional and behavioral disorders (EBDs). Psychometric properties are critical to making decisions about choosing a screening instrument. The purpose of the present study was to examine the psychometric properties of the student risk screening scale for internalizing and externalizing behaviors (SRSS-IE). Participants included 3145 students and their teachers. Item-level analyses of the current sample supported the retention of all items. The internal consistency of the SRSS items ranged from 0.83 to 0.85. Convergent validity between the SRSS-IE and a well-established screening tool, the strength and difficulties questionnaire (SDQ), was found for the total score (r = 0.70). Additionally, the results of this study demonstrate strong social validity, suggesting the SRSS-IE to be a useful and functional screening tool. We conclude that the SRSS-IE is a valid and reliable instrument for assessing the level of emotional and behavioral difficulties among elementary students.
文摘Irritable bowel syndrome(IBS-D)with diarrhea is a common gastrointestinal functional disease in clinical practice,which seriously affects the quality of life of patients.Cur‐rently,Western medicine has poor therapeutic effects,while traditional Chinese medi‐cine has unique advantages in relieving IBS-D symptoms and preventing recurrence.In recent years,especially with external treatment of traditional Chinese medicine,it has become a new treatment direction in clinical practice and has achieved good therapeutic effects.This article will provide a review of recent research on the treatment of IBS-D using traditional Chinese medicine external treatment methods.
基金financially supported by the National Key Research and Development Program of China(Grant No.2022YFB2602800)the National Natural Science Foundation of China(Grant Nos.51879231,51679214)。
文摘This paper aims to enhance the compression capacity of underwater cylindrical shells by adopting the corrugated sandwich structure of cuttlebone.The cuttlebone suffers uniaxial external compression,while underwater cylindrical shells are in a biaxial compressive stress state.To suit the biaxial compressive stress state,a novel bidirectional corrugated sandwich structure is proposed to improve the bearing capacity of cylindrical shells.The static and buckling analysis for the sandwich shell and the unstiffened cylindrical shell with the same volume-weight ratio are studied by numerical simulation.It is indicated that the proposed sandwich shell can effectively reduce the ratio between circumferential and axial stress from 2 to 1.25 and improve the critical buckling load by about 1.63 times.Numerical simulation shows that optimizing and adjusting the structural parameters could significantly improve the advantage of the sandwich shell.Then,the hydrostatic pressure tests for shell models fabricated by 3D printing are carried out.According to the experimental results,the overall failure position of the sandwich shell is at the center part of the sandwich shell.It has been found the average critical load of the proposed sandwich shell models exceeds two times that of the unstiffened shell models.Hence,the proposed bio-inspired bidirectional corrugated sandwich structure can significantly enhance the pressure resistance capability of cylindrical shells.
基金Project supported by the National Natural Science Foundation of China (Grant No.12065015)the Hongliu Firstlevel Discipline Construction Project of Lanzhou University of Technology。
文摘The instability of plasma waves in the channel of field-effect transistors will cause the electromagnetic waves with THz frequency.Based on a self-consistent quantum hydrodynamic model,the instability of THz plasmas waves in the channel of graphene field-effect transistors has been investigated with external magnetic field and quantum effects.We analyzed the influence of weak magnetic fields,quantum effects,device size,and temperature on the instability of plasma waves under asymmetric boundary conditions numerically.The results show that the magnetic fields,quantum effects,and the thickness of the dielectric layer between the gate and the channel can increase the radiation frequency.Additionally,we observed that increase in temperature leads to a decrease in both oscillation frequency and instability increment.The numerical results and accompanying images obtained from our simulations provide support for the above conclusions.
基金financially supported by the National Key Research and Development Program of China(2022YFB3404201)the Major Science and Technology Project of Changchun City,Jilin Province(Grant No.20210301024GX)。
文摘The effect of slow shot speed on externally solidified crystal(ESC),porosity and tensile property in a newly developed high-pressure die-cast Al-Si alloy was investigated by optical microscopy(OM),scanning electron microscopy(SEM)and laboratory computed tomography(CT).Results showed that the newly developed AlSi9MnMoV alloy exhibited improved mechanical properties when compared to the AlSi10MnMg alloy.The AlSi9MnMoV alloy,which was designed with trace multicomponent additions,displays a notable grain refining effect in comparison to the AlSi10MnMg alloy.Refining elements Ti,Zr,V,Nb,B promote heterogeneous nucleation and reduce the grain size of primaryα-Al.At a lower slow shot speed,the large ESCs are easier to form and gather,developing into the dendrite net and net-shrinkage.With an increase in slow shot speed,the size and number of ESCs and porosities significantly reduce.In addition,the distribution of ESCs is more dispersed and the net-shrinkage disappears.The tensile property is greatly improved by adopting a higher slow shot speed.The ultimate tensile strength is enhanced from 260.31 MPa to 290.31 MPa(increased by 11.52%),and the elongation is enhanced from 3.72%to 6.34%(increased by 70.52%).
基金Project supported by the Industry and Education Combination Innovation Platform of Intelligent Manufacturing and Graduate Joint Training Base at Guizhou University(Grant No.2020-520000-83-01-324061)the National Natural Science Foundation of China(Grant No.61264004)the High-level Creative Talent Training Program in Guizhou Province of China(Grant No.[2015]4015).
文摘Recently,the newly synthesized septuple-atomic layer two-dimensional(2D)material MoSi_(2)N_(4)(MSN)has attracted attention worldwide.Our work delves into the effect of vacancies and external electric fields on the electronic properties of the MSN/graphene(Gr)heterostructure using first-principles calculation.We find that four types of defective structures,N-in,N-out,Si and Mo vacancy defects of monolayer MSN and MSN/Gr heterostructure are stable in air.Moreover,vacancy defects can effectively modulate the charge transfer at the interface of the MSN/Gr heterostructure as well as the work function of the pristine monolayer MSN and MSN/Gr heterostructure.Finally,the application of an external electric field enables the dynamic switching between n-type and p-type Schottky contacts.Our work may offer the possibility of exceeding the capabilities of conventional Schottky diodes based on MSN/Gr heterostructures.